Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
J Med Chem ; 66(3): 1941-1954, 2023 02 09.
Artículo en Inglés | MEDLINE | ID: mdl-36719971

RESUMEN

Long-acting (LA) human immunodeficiency virus-1 (HIV-1) antiretroviral therapy characterized by a ≥1 month dosing interval offers significant advantages over daily oral therapy. However, the criteria for compounds that enter clinical development are high. Exceptional potency and low plasma clearance are required to meet dose size requirements; excellent chemical stability and/or crystalline form stability is required to meet formulation requirements, and new antivirals in HIV-1 therapy need to be largely free of side effects and drug-drug interactions. In view of these challenges, the discovery that capsid inhibitors comprising a quinazolinone core tolerate a wide range of structural modifications while maintaining picomolar potency against HIV-1 infection in vitro, are assembled efficiently in a multi-component reaction, and can be isolated in a stereochemically pure form is reported herein. The detailed characterization of a prototypical compound, GSK878, is presented, including an X-ray co-crystal structure and subcutaneous and intramuscular pharmacokinetic data in rats and dogs.


Asunto(s)
Fármacos Anti-VIH , Infecciones por VIH , VIH-1 , Humanos , Ratas , Animales , Perros , Cápside , Proteínas de la Cápside , Quinazolinonas/farmacología , Quinazolinonas/uso terapéutico , Fármacos Anti-VIH/farmacocinética , Infecciones por VIH/tratamiento farmacológico
2.
J Pharm Sci ; 105(3): 1036-42, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26886323

RESUMEN

Membrane-based devices typically used for serum protein binding determination are not fully applicable to highly lipophilic compounds because of nonspecific binding to the device membrane. Ultracentrifugation, however, completely eliminates the issue by using a membrane-free approach, although its wide application has been limited. This lack of utilization is mainly attributed to 2 factors: the high cost in acquiring and handling of radiolabeled compounds and low assay throughput owing to the difficulties in process automation. To overcome these challenges, we report a high-throughput workflow by cassette ultracentrifugation of nonradiolabeled compounds followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis. Twenty compounds with diverse physicochemical and protein binding properties were selected for the evaluation of the workflow. To streamline the working process, approaches of matrix balancing for all the samples for LC-MS/MS analysis and determining free fraction without analytical calibration curves were adopted. Both the discrete ultracentrifugation of individual compounds and cassette ultracentrifugation of all the test compounds followed by simultaneous LC-MS/MS analysis exhibited a linear correlation with literature values, demonstrating respectively the validity of the ultracentrifugation process and the cassette approach. The cassette ultracentrifugation using nonradiolabeled compounds followed by LC-MS/MS analysis has greatly facilitated its application for high-throughput protein binding screening in drug discovery.


Asunto(s)
Proteínas Sanguíneas/química , Cromatografía Líquida de Alta Presión/métodos , Preparaciones Farmacéuticas/química , Unión Proteica , Espectrometría de Masas en Tándem/métodos , Ultracentrifugación/métodos , Descubrimiento de Drogas/métodos , Marcaje Isotópico/métodos , Suero/química , Coloración y Etiquetado/métodos , Flujo de Trabajo
3.
Bioorg Med Chem Lett ; 21(22): 6693-8, 2011 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-21983444

RESUMEN

Derived from the HTS hit 1, a series of hydroxyisoquinolines was discovered as potent and selective 11ß-HSD1 inhibitors with good cross species activity. Optimization of substituents at the 1 and 4 positions of the isoquinoline group in addition to the core modifications, with a special focus on enhancing metabolic stability and aqueous solubility, resulted in the identification of several compounds as potent advanced leads.


Asunto(s)
11-beta-Hidroxiesteroide Deshidrogenasa de Tipo 1/antagonistas & inhibidores , 11-beta-Hidroxiesteroide Deshidrogenasa de Tipo 1/metabolismo , Inhibidores Enzimáticos/química , Inhibidores Enzimáticos/farmacología , Isoquinolinas/química , Isoquinolinas/farmacología , Animales , Línea Celular , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Inhibidores Enzimáticos/farmacocinética , Humanos , Isoquinolinas/farmacocinética , Ratones , Ratones Endogámicos BALB C , Relación Estructura-Actividad
4.
Rapid Commun Mass Spectrom ; 24(24): 3593-601, 2010 Dec 30.
Artículo en Inglés | MEDLINE | ID: mdl-21080511

RESUMEN

Quantification of small molecules using liquid chromatography/tandem mass spectrometry (LC/MS/MS) on a triple quadrupole mass spectrometer has become a common practice in bioanalytical support of in vitro adsorption, distribution, metabolism and excretion (ADME) screening. The bioanalysis process involves primarily three indispensable steps: MS/MS optimization for a large number of new chemical compounds undergoing various screening assays in early drug discovery, high-throughput sample analysis with LC/MS/MS for those chemically diverse compounds using the optimized MS/MS conditions, and post-acquisition data review and reporting. To improve overall efficiency of ADME bioanalysis, an integrated system was proposed featuring an automated and unattended MS/MS optimization, a staggered parallel LC/MS/MS for high-throughput sample analysis, and a sophisticated software tool for LC/MS/MS raw data review as well as biological data calculation and reporting. The integrated platform has been used in bioanalytical support of a serum protein binding screening assay with high speed, high capacity, and good robustness. In this new platform, a unique sample dilution scheme was also introduced. With this dilution design, the total number of analytical samples was reduced; therefore, the total operation time was reduced and the overall throughput was further improved. The performance of the protein binding screening assay was monitored with two controls representing high and low binding properties and an acceptable inter-assay consistency was achieved. This platform has been successfully used for the determination of serum protein binding in multiple species for more than 4000 compounds.


Asunto(s)
Proteínas Sanguíneas/metabolismo , Descubrimiento de Drogas/métodos , Ensayos Analíticos de Alto Rendimiento/métodos , Animales , Proteínas Sanguíneas/química , Cromatografía Liquida , Perros , Humanos , Modelos Lineales , Macaca fascicularis , Masculino , Ratones , Farmacocinética , Unión Proteica , Ratas , Reproducibilidad de los Resultados , Integración de Sistemas , Espectrometría de Masas en Tándem
5.
Rapid Commun Mass Spectrom ; 23(11): 1579-91, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19399765

RESUMEN

Liquid chromatography/tandem mass spectrometry (LC/MS/MS) is the bioanalytical method of choice to support plate-based, in vitro early ADME (Absorption, Distribution, Metabolism and Excretion) screens such as metabolic stability (Metstab) assessment. MS/MS method optimization has historically been the bottleneck in this environment, where samples from thousands of discrete compounds are analyzed on a monthly basis, mainly due to the lack of a high-quality commercially available platform to handle the necessary MS/MS method optimization steps for sample analysis by selected reaction monitoring (SRM) on triple quadrupole mass spectrometers. To address this challenge, we recently developed a highly automated bioanalytical platform by successfully integrating QuickQuan 2.0, a unique high-throughput solution featuring MS/MS method optimization by automated infusion, with a customized in-house software tool in support of a Metstab screen. In this platform, a dual-column setup running parallel chromatography was also implemented to reduce the bioanalytical cycle time for LC/MS/MS sample analysis. A set of 45 validation compounds was used to demonstrate the speed, quality and reproducibility of MS/MS method optimization, sample analysis, and data processing using this automated platform. Metstab results for the validation compounds in microsomes from multiple species (human, rat, mouse) showed good consistency within each batch, and also between batches conducted on different days. We have achieved and maintained a monthly throughput of 1300 compound assays representing 500 discrete compounds per instrument per month on this platform, and it has been used to generate metabolic stability data for more than 25 000 compounds to date with an overall success rate of more than 95%.


Asunto(s)
Microsomas/metabolismo , Espectrometría de Masas en Tándem/métodos , Animales , Automatización , Sistema Enzimático del Citocromo P-450/metabolismo , Humanos , Ratones , Ratas , Programas Informáticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA