1.
Sci Rep ; 13(1): 12407, 2023 07 31.
Artículo en Inglés | MEDLINE | ID: mdl-37524855

RESUMEN

Quantum sensors using solid state qubits have demonstrated outstanding sensitivity, beyond that possible using classical devices. In particular, those based on colour centres in diamond have demonstrated high sensitivity to magnetic field through exploiting the field-dependent emission of fluorescence under coherent control using microwaves. Given the highly biocompatible nature of diamond, sensing from biological samples is a key interdisciplinary application. In particular, the microscopic-scale study of living systems can be possible through recording of temperature and biomagnetic field. In this work, we use such a quantum sensor to demonstrate such microscopic-scale recording of electrical activity from neurons in fragile living brain tissue. By recording weak magnetic field induced by ionic currents in mouse corpus callosum axons, we accurately recover signals from neuronal action potential propagation while demonstrating in situ pharmacology. Our sensor allows recording of the electrical activity in neural circuits, disruption of which can shed light on the mechanisms of disease emergence. Unlike existing techniques for recording activity, which can require potentially damaging direct interaction, our sensing is entirely passive and remote from the sample. Our results open a promising new avenue for the microscopic recording of neuronal signals, offering the eventual prospect of microscopic imaging of electrical activity in the living mammalian brain.


Asunto(s)
Encéfalo , Diamante , Animales , Ratones , Encéfalo/fisiología , Campos Magnéticos , Neuronas/fisiología , Fluorescencia , Mamíferos
2.
Sci Rep ; 11(1): 2412, 2021 01 28.
Artículo en Inglés | MEDLINE | ID: mdl-33510264

RESUMEN

The ability to perform noninvasive and non-contact measurements of electric signals produced by action potentials is essential in biomedicine. A key method to do this is to remotely sense signals by the magnetic field they induce. Existing methods for magnetic field sensing of mammalian tissue, used in techniques such as magnetoencephalography of the brain, require cryogenically cooled superconducting detectors. These have many disadvantages in terms of high cost, flexibility and limited portability as well as poor spatial and temporal resolution. In this work we demonstrate an alternative technique for detecting magnetic fields generated by the current from action potentials in living tissue using nitrogen vacancy centres in diamond. With 50 pT/[Formula: see text] sensitivity, we show the first measurements of magnetic sensing from mammalian tissue with a diamond sensor using mouse muscle optogenetically activated with blue light. We show these proof of principle measurements can be performed in an ordinary, unshielded lab environment and that the signal can be easily recovered by digital signal processing techniques. Although as yet uncompetitive with probe electrophysiology in terms of sensitivity, we demonstrate the feasibility of sensing action potentials via magnetic field in mammals using a diamond quantum sensor, as a step towards microscopic imaging of electrical activity in a biological sample using nitrogen vacancy centres in diamond.


Asunto(s)
Técnicas Biosensibles , Diamante , Fenómenos Electrofisiológicos , Músculos/fisiología , Animales , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Campos Magnéticos , Relación Señal-Ruido
3.
Nat Commun ; 12(1): 532, 2021 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-33483515

RESUMEN

High-fidelity projective readout of a qubit's state in a single experimental repetition is a prerequisite for various quantum protocols of sensing and computing. Achieving single-shot readout is challenging for solid-state qubits. For Nitrogen-Vacancy (NV) centers in diamond, it has been realized using nuclear memories or resonant excitation at cryogenic temperature. All of these existing approaches have stringent experimental demands. In particular, they require a high efficiency of photon collection, such as immersion optics or all-diamond micro-optics. For some of the most relevant applications, such as shallow implanted NV centers in a cryogenic environment, these tools are unavailable. Here we demonstrate an all-optical spin readout scheme that achieves single-shot fidelity even if photon collection is poor (delivering less than 103 clicks/second). The scheme is based on spin-dependent resonant excitation at cryogenic temperature combined with spin-to-charge conversion, mapping the fragile electron spin states to the stable charge states. We prove this technique to work on shallow implanted NV centers, as they are required for sensing and scalable NV-based quantum registers.

4.
ACS Comb Sci ; 15(8): 401-9, 2013 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-23697925

RESUMEN

A Lia(NixMnyCoz)Or cathode materials library was fabricated by combinatorial magnetron sputtering. The compositional analysis of the library was performed by a new high-throughput approach for Li-content measurement in thin films, which combines automated energy-dispersive X-ray spectroscopy, Deuteron-induced gamma emission, and Rutherford backscattering measurements. Furthermore, combining this approach with thickness measurements allows the mapping of density values of samples from the materials library. By correlating the obtained compositional data with structural data from high-throughput X-ray diffraction measurements, those compositions which show a layered (R3̅m) structure and are therefore most interesting for Li-battery applications (for cathode (positive) electrodes) can be rapidly identified. This structure was identified as being most pronounced in the compositions Li0.6(Ni0.16Mn0.35Co0.48)O2, Li0.7(Ni0.10Mn0.37Co0.51)O2, Li0.6(Ni0.23Mn0.33Co0.43)O2, Li0.3(Ni0.65Mn0.08Co0.26)O2, Li0.3(Ni0.63Mn0.08Co0.29)O2, Li0.4(Ni0.56Mn0.09Co0.34)O2, Li0.5(Ni0.45Mn0.13Co0.42)O2, and Li0.6(Ni0.34Mn0.14Co0.52)O2.


Asunto(s)
Suministros de Energía Eléctrica , Ensayos Analíticos de Alto Rendimiento , Compuestos de Litio/química , Estructura Molecular , Difracción de Rayos X
5.
J Phys Condens Matter ; 23(26): 265501, 2011 Jul 06.
Artículo en Inglés | MEDLINE | ID: mdl-21666304

RESUMEN

In a previous paper (Sonntag 2010 J. Phys.: Condens. Matter 22 235501) the classical thermopower formula has been argued to be incomplete, because it only takes into account the scattering properties of the carriers, but not the temperature dependence of the electrochemical potential µ caused by variation of the carrier density and/or band edge shift with temperature T. This argument is now checked experimentally by high-throughput measurements of the thermopower (Seebeck coefficient) S of a-(Cr(1-x)Si(x))(1-y)O(y) thin film materials libraries. The concentration dependences of S differ depending on whether the measurements are done with the complete film (where x ranges continuously from x≈0.3 to 0.8; y≈0.1-0.2) or with the separated pieces (each piece with another average value of x). These differences are especially large if, in addition, an oxygen gradient is present.

6.
Sci Technol Adv Mater ; 12(5): 054208, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27877435

RESUMEN

Combinatorial magnetron sputter deposition from elemental targets was used to create Fe-B composition spread type thin film materials libraries on thermally oxidized 4-in. Si wafers. The materials libraries consisting of wedge-type multilayer thin films were annealed at 500 or 700 °C to transform the multilayers into multiphase alloys. The libraries were characterized by nuclear reaction analysis, Rutherford backscattering, nanoindentation, vibrating sample magnetometry, x-ray diffraction (XRD) and transmission electron microscopy (TEM). Young's modulus and hardness values were related to the annealing parameters, structure and composition of the films. The magnetic properties of the films were improved by annealing in a H2 atmosphere, showing a more than tenfold decrease in the coercive field values in comparison to those of the vacuum-annealed films. The hardness values increased from 8 to 18 GPa when the annealing temperature was increased from 500 to 700 °C. The appearance of Fe2B phases, as revealed by XRD and TEM, had a significant effect on the mechanical properties of the films.