Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Front Cardiovasc Med ; 11: 1371810, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38873265

RESUMEN

Background: Cardiac systolic dysfunction is a poor prognostic marker in light-chain (AL) cardiomyopathy, a primary interstitial disorder; however, its pathogenesis is poorly understood. Purpose: This study aims to analyze the effects of extracellular volume (ECV) expansion, a surrogate marker of amyloid burden on myocardial blood flow (MBF), myocardial work efficiency (MWE), and left ventricular (LV) systolic dysfunction in AL amyloidosis. Methods: Subjects with biopsy-proven AL amyloidosis were prospectively enrolled (April 2016-June 2021; Clinicaltrials.gov ID NCT02641145) and underwent cardiac magnetic resonance imaging (MRI) to quantify rest MBF by perfusion imaging, LV ejection fraction (LVEF) by cine MRI, and ECV by pre- and post-contrast T1 mapping. The MWE was estimated as external cardiac work from the stroke volume and mean arterial pressure normalized to the LV myocardial mass. Results: Rest MBF in 92 subjects (62 ± 8 years, 52 men) with AL amyloidosis averaged 0.87 ± 0.21 ml/min/g and correlated with MWE (r = 0.42; p < 0.001). Rest MBF was similarly low in subjects with sustained hematologic remission after successful AL amyloidosis therapy (n = 21), as in those with recently diagnosed AL amyloidosis. Both MBF and MWE decreased by ECV tertile (p < 0.01 for linear trends). The association of ECV with MWE comprised a direct effect (84% of the total effect; p < 0.001) on MWE from adverse interstitial remodeling assessed by ECV and an indirect effect (16% of the total effect; p < 0.001) mediated by MBF. There was a significant base-to-apex gradient of rest MBF in subjects with higher amyloid burden. Conclusions: In AL amyloidosis, both MBF and MWE decrease as cardiac amyloid burden and ECV expansion increase. Both structural and vascular changes from ECV expansion and myocardial amyloid burden appear to contribute to lower MWE.

2.
Eur Heart J Cardiovasc Imaging ; 25(5): 687-697, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38193678

RESUMEN

AIMS: In systemic light-chain (AL) amyloidosis, quantification of right ventricular (RV) amyloid burden has been limited and the pathogenesis of RV dysfunction is poorly understood. Using 18F-florbetapir positron emission tomography/computed tomography (PET/CT), we aimed to quantify RV amyloid; correlate RV amyloid with RV structure and function; determine the independent contributions of RV, left ventricular (LV), and lung amyloid to RV function; and associate RV amyloid with major adverse cardiac events (MACE: death, heart failure hospitalization, cardiac transplantation). METHODS AND RESULTS: We prospectively enrolled 106 participants with AL amyloidosis (median age 62 years, 55% males) who underwent 18F-florbetapir PET/CT, magnetic resonance imaging, and echocardiography. 18F-florbetapir PET/CT identified RV amyloid in 63% of those with and 40% of those without cardiac involvement by conventional criteria. RV amyloid burden correlated with RV ejection fraction (EF), RV free wall longitudinal strain (FWLS), RV wall thickness, RV mass index, N-terminal pro-brain natriuretic peptide, troponin T, LV amyloid, and lung amyloid (each P < 0.001). In multivariable analysis, RV amyloid burden, but not LV or lung amyloid burden, predicted RV dysfunction (EF P = 0.014; FWLS P < 0.001). During a median follow-up of 28 months, RV amyloid burden predicted MACE (P < 0.001). CONCLUSION: This study shows for the first time that 18F-florbetapir PET/CT identifies early RV amyloid in systemic AL amyloidosis prior to alterations in RV structure and function. Increasing RV amyloid on 18F-florbetapir PET/CT is associated with worse RV structure and function, predicts RV dysfunction, and predicts MACE. These results imply a central role for RV amyloid in the pathogenesis of RV dysfunction.


Asunto(s)
Compuestos de Anilina , Glicoles de Etileno , Tomografía Computarizada por Tomografía de Emisión de Positrones , Disfunción Ventricular Derecha , Humanos , Masculino , Femenino , Persona de Mediana Edad , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Estudios Prospectivos , Disfunción Ventricular Derecha/diagnóstico por imagen , Anciano , Amiloidosis de Cadenas Ligeras de las Inmunoglobulinas/diagnóstico por imagen , Amiloidosis de Cadenas Ligeras de las Inmunoglobulinas/complicaciones , Radiofármacos , Ventrículos Cardíacos/diagnóstico por imagen
3.
J Nucl Med ; 64(Suppl 2): 20S-28S, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37918844

RESUMEN

Myocardial infiltration by amyloid fibrils causes a severe and progressive form of heart failure. Until recently, this was not treatable. Several novel therapies have recently become available, increasing the urgency to make an accurate diagnosis, evaluate risk, and determine treatment response. Molecular imaging with positron-emitting amyloid tracers has a key emerging role in the evaluation and management of cardiac amyloidosis. In this review, we discuss molecular imaging of cardiac amyloidosis using amyloid PET tracers, including recent advances with a focus on the future.


Asunto(s)
Amiloidosis , Cardiomiopatías , Insuficiencia Cardíaca , Humanos , Amiloidosis/diagnóstico por imagen , Amiloide , Miocardio , Imagen Molecular , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/terapia
4.
medRxiv ; 2023 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-37873250

RESUMEN

Aims: In systemic light-chain (AL) amyloidosis, cardiac involvement portends poor prognosis. Using myocardial characteristics on magnetic resonance imaging (MRI), this study aimed to detect early myocardial alterations, to analyze temporal changes with plasma cell therapy, and to predict risk of major adverse cardiac events (MACE) in AL amyloidosis. Methods and Results: Participants with recently diagnosed AL amyloidosis were prospectively enrolled. Presence of AL cardiomyopathy (AL-CMP vs. AL-non-CMP) was determined by abnormal cardiac biomarkers. MRI was performed at baseline and 6 months, with 12-month imaging in AL-CMP cohort. MACE was defined as all-cause death, heart failure hospitalization, or cardiac transplantation. Mayo AL stage was based on troponin T, NT-proBNP, and difference in free light chains. The study cohort included 80 participants (median age 62 years, 58% males). Median left ventricular extracellular volume (ECV) was significantly higher in AL-CMP (53% vs. 30%, p<0.001). ECV was abnormal (>32%) in all AL-CMP and in 47% of AL-non-CMP. ECV tended to increase at 6 months and decreased significantly from 6 to 12 months in AL-CMP (median -3%, p=0.011). ECV was strongly associated with MACE (p<0.001), and improved MACE prediction when added to Mayo AL stage (p=0.002). ECV≤32% identified a cohort without MACE, while ECV>48% identified a cohort with 74% MACE. Conclusions: In AL amyloidosis, ECV detects subclinical cardiomyopathy. ECV tends to increase from baseline to 6 months and decreases significantly from 6 and 12 months of plasma cell therapy in AL-CMP. ECV provides excellent risk stratification and offers additional prognostic performance over Mayo AL stage.

5.
Circ Cardiovasc Imaging ; 16(9): e015324, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37655498

RESUMEN

BACKGROUND: Given the central importance of cardiorenal interactions, mechanistic tools for evaluating cardiorenal physiology are needed. In the heart and kidneys, shared pathways of neurohormonal activation, hypertension, and vascular and interstitial fibrosis implicate the relevance of systemic vascular health. The availability of a long axial field of view positron emission tomography (PET)/computed tomography (CT) system enables simultaneous evaluation of cardiac and renal blood flow. METHODS: This study evaluated the feasibility of quantification of renal blood flow using data acquired during routine, clinically indicated 13N-ammonia myocardial perfusion PET/CT. Dynamic PET image data were used to calculate renal blood flow. Reproducibility was assessed by the intraclass correlation coefficient among 3 independent readers. PET-derived renal blood flow was correlated with imaging and clinical parameters in the overall cohort and with histopathology in a small companion study of patients with a native kidney biopsy. RESULTS: Among 386 consecutive patients with myocardial perfusion PET/CT, 296 (76.7%) had evaluable images to quantify renal perfusion. PET quantification of renal blood flow was highly reproducible (intraclass correlation coefficient 0.98 [95% CI, 0.93-0.99]) and was correlated with the estimated glomerular filtration rate (r=0.64; P<0.001). Compared across vascular beds, resting renal blood flow was correlated with maximal stress myocardial blood flow and myocardial flow reserve (stress/rest myocardial blood flow), an integrated marker of endothelial health. In patients with kidney biopsy (n=12), resting PET renal blood flow was strongly negatively correlated with histological interstitial fibrosis (r=-0.85; P<0.001). CONCLUSIONS: Renal blood flow can be reliably measured from cardiac 13N-ammonia PET/CT and allows for simultaneous assessment of myocardial and renal perfusion, opening a potential novel avenue to interrogate the mechanisms of emerging therapies with overlapping cardiac and renal benefits.


Asunto(s)
Amoníaco , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Estudios de Factibilidad , Reproducibilidad de los Resultados , Tomografía de Emisión de Positrones , Riñón/diagnóstico por imagen , Perfusión , Fibrosis
6.
JACC Cardiovasc Imaging ; 16(11): 1419-1432, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37676210

RESUMEN

BACKGROUND: Cardiac amyloid quantification could advance early diagnosis of amyloid cardiomyopathy (CMP) and treatment monitoring. However, current imaging tools are based on indirect measurements. 124I-evuzamitide is a novel pan-amyloid radiotracer binding to amyloid deposits from multiple amyloidogenic proteins. Its ability to quantify cardiac amyloid has not yet been investigated. OBJECTIVES: The objectives of this pilot study were to quantify myocardial 124I-evuzamitide uptake and to compare its diagnostic value to 18F-florbetapir in participants with amyloid CMP and control subjects. METHODS: This study included 46 participants: 12 with light-chain (AL) CMP, 12 with wild-type transthyretin (ATTRwt) CMP, 2 with hereditary amyloidosis, and 20 control subjects. All amyloidosis participants underwent positron emission tomography/computed tomography with 124I-evuzamitide and 18F-florbetapir. Control subjects underwent 124I-evuzamitide (n = 10) or 18F-florbetapir (n = 8) positron emission tomography/computed tomography. Left ventricular percent injected dose (LV% ID) was measured as mean activity concentration × myocardial volume/injected activity. High LV %ID was defined using Youden's index. RESULTS: In CMP participants, median age was 74 years and 92% were men. 124I-evuzamitide LV %ID differed across groups: median AL-CMP 1.48 (IQR: 1.12-1.89), ATTRwt-CMP 2.12 (IQR: 1.66-2.47), and control subjects 0.00 (IQR: 0.00-0.01; overall P < 0.001). High LV %ID perfectly discriminated CMP from control subjects. Discrimination performance was similar for 18F-florbetapir LV %ID. Notably, for ATTRwt-CMP, LV %ID was higher with 124I-evuzamitide than 18F-florbetapir (P = 0.002). 124I-evuzamitide LV %ID was correlated with interventricular septum thickness (Spearman's ρ = 0.78) and LV global longitudinal strain (ρ = 0.54) from echocardiography, and with LV mass index (ρ = 0.82) and extracellular volume (ρ = 0.51) from cardiac magnetic resonance. CONCLUSIONS: 124I-evuzamitide demonstrates uptake by cardiac amyloid and accurately discriminates amyloid CMP from control subjects. In AL-CMP, discrimination performance is similar to 18F-florbetapir. In ATTRwt-CMP, performance may be better with 124I-evuzamitide. Moderate-to-strong correlations of 124I-evuzamitide uptake with cardiac structural and functional metrics suggest valid amyloid quantification. Hence, 124I-evuzamitide is a promising novel radiotracer to detect and quantify cardiac amyloid.


Asunto(s)
Amiloidosis , Tomografía Computarizada por Tomografía de Emisión de Positrones , Masculino , Humanos , Anciano , Femenino , Proyectos Piloto , Valor Predictivo de las Pruebas , Amiloide , Proteínas Amiloidogénicas/metabolismo
7.
medRxiv ; 2023 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-37745589

RESUMEN

Background: Myocardial immunoglobulin light-chain (AL) amyloid deposits trigger heart failure, cardiomyocyte stretch and myocardial injury, leading to adverse cardiac outcomes. Positron emission tomography/computed tomography (PET/CT) with 18 F-florbetapir, a novel amyloid-targeting radiotracer, can quantify left ventricular (LV) amyloid burden, but its prognostic value is not known. Therefore, we aimed to evaluate the prognostic value of LV amyloid burden quantified by 18 F-florbetapir PET/CT and to identify mechanistic pathways mediating its association with outcomes. Methods: Eighty-one participants with newly-diagnosed systemic AL amyloidosis were prospectively enrolled and underwent 18 F-florbetapir PET/CT. LV amyloid burden was quantified using 18 F-florbetapir LV percent injected dose (%ID). Mayo AL stage was determined using troponin T, N-terminal pro-B-type natriuretic peptide (NT-proBNP), and difference between involved and uninvolved free light chain levels. Major adverse cardiac events (MACE) were defined as all-cause death, heart failure hospitalization, or cardiac transplantation within 12 months. Results: Among participants (median age 61 years, 57% males), 36% experienced MACE. Incidence of MACE increased across tertiles of LV amyloid burden from 7% to 63% (p<0.001). LV amyloid burden was significantly associated with MACE in univariable analysis (hazard ratio 1.45, 95% confidence interval 1.15-1.82, p=0.002). However, this association became non-significant in multivariable analyses adjusted for Mayo AL stage. Mediation analysis showed that the association between 18 F-florbetapir LV %ID and MACE was primarily mediated by NT-proBNP (p<0.001), a marker of cardiomyocyte stretch and component of Mayo AL stage. Conclusion: In this first study to link cardiac 18 F-florbetapir uptake to subsequent outcomes, LV amyloid burden estimated by LV %ID predicted MACE in AL amyloidosis. But this effect was not independent of Mayo AL stage. LV amyloid burden was associated with MACE primarily via NT-pro-BNP, a marker of cardiomyocyte stretch and component of Mayo AL stage. These findings provide novel insights into the mechanism through which myocardial AL amyloid leads to MACE. Clinical Perspective: In systemic light-chain (AL) amyloidosis, cardiac involvement is the key determinant of adverse outcomes. Usually, prognosis is based on the Mayo AL stage, determined by troponin T, N-terminal pro-B-type natriuretic peptide (NT-proBNP), and the difference between involved and uninvolved immunoglobulin free light chain levels (dFLC). Cardiac amyloid burden is not considered in this staging. In the present study, we used the amyloid-specific radiotracer 18 F-florbetapir to quantify left ventricular (LV) amyloid burden in 81 participants with newly-diagnosed AL amyloidosis and evaluated its prognostic value on major adverse outcomes (MACE: all-cause death, heart failure hospitalization, or cardiac transplantation within 12 months). We found that higher LV amyloid burden by 18 F-florbetapir positron emission tomography/computed tomography (PET/CT) was strongly associated with MACE. However, this association became non-significant after adjustment for the Mayo AL stage. Mediation analysis offered novel pathophysiological insights, implying that LV amyloid burden leads to MACE predominantly through cardiomyocyte stretch and light chain toxicity (by NT-proBNP), rather than through myocardial injury (by troponin T), also considering the severity of plasma cell dyscrasia (by dFLC). This mediation by NT-proBNP may explain why the association with outcomes was non-significant with adjustment for Mayo AL stage. Together, these results establish quantitative 18 F-florbetapir PET/CT as a valid method to predict adverse outcomes in AL amyloidosis. These results support the use of 18 F-florbetapir PET/CT to measure the effects of novel fibril-depleting therapies, in addition to plasma cell therapy, to improve outcomes in systemic AL amyloidosis.

9.
Phys Med Biol ; 67(2)2022 01 19.
Artículo en Inglés | MEDLINE | ID: mdl-34891142

RESUMEN

Breathing motion can displace internal organs by up to several cm; as such, it is a primary factor limiting image quality in medical imaging. Motion can also complicate matters when trying to fuse images from different modalities, acquired at different locations and/or on different days. Currently available devices for monitoring breathing motion often do so indirectly, by detecting changes in the outline of the torso rather than the internal motion itself, and these devices are often fixed to floors, ceilings or walls, and thus cannot accompany patients from one location to another. We have developed small ultrasound-based sensors, referred to as 'organ configuration motion' (OCM) sensors, that attach to the skin and provide rich motion-sensitive information. In the present work we tested the ability of OCM sensors to enable respiratory gating duringin vivoPET imaging. A motion phantom involving an FDG solution was assembled, and two cancer patients scheduled for a clinical PET/CT exam were recruited for this study. OCM signals were used to help reconstruct phantom andin vivodata into time series of motion-resolved images. As expected, the motion-resolved images captured the underlying motion. In Patient #1, a single large lesion proved to be mostly stationary through the breathing cycle. However, in Patient #2, several small lesions were mobile during breathing, and our proposed new approach captured their breathing-related displacements. In summary, a relatively inexpensive hardware solution was developed here for respiration monitoring. Because the proposed sensors attach to the skin, as opposed to walls or ceilings, they can accompany patients from one procedure to the next, potentially allowing data gathered in different places and at different times to be combined and compared in ways that account for breathing motion.


Asunto(s)
Imagen Multimodal , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Movimiento (Física) , Fantasmas de Imagen , Tomografía de Emisión de Positrones/métodos
10.
JACC Cardiovasc Imaging ; 15(4): 594-603, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34922860

RESUMEN

OBJECTIVES: The goals of this study were to characterize myocardial composition during the active and remission phases of light-chain (AL) cardiac amyloidosis. BACKGROUND: Cardiac dysfunction in AL amyloidosis is characterized by dual insults to the myocardium from infiltration and toxicity from light chains during the active phase and by infiltration alone in the remission phase. METHODS: Prospectively enrolled subjects with cardiac AL amyloidosis (21 remission AL amyloidosis; age: 63.4 ± 7.3 years; 47.6% male; and 48 active AL amyloidosis; age: 62.5 ± 7.4 years; 60.4% male) underwent contrast-enhanced cardiac magnetic resonance with T1 and T2 mapping and measurement of extracellular volume (ECV). By definition, serum free light-chain levels were normal for at least 1 year following successful AL therapy in the remission group and abnormal in the active group. RESULTS: Myocardial ECV was similarly expanded in the remission and active AL amyloidosis groups (0.488 ± 0.082 vs 0.519 ± 0.083, respectively; P = 0.15). However, myocardial T2 relaxation times (47.7 ± 3.2 ms vs 45.5 ± 3.0 ms; P = 0.008) as well as native T1 times (1,368 ms [IQR: 1,290-1,422 ms] vs 1,264 ms [IQR: 1,203-1,380 ms]; P = 0.024) were significantly higher in the remission compared to the active AL amyloidosis group. CONCLUSIONS: Myocardial ECV is substantially expanded in the active AL and remission AL cardiac amyloidosis groups, but native T1 values were higher, suggesting a different myocardial composition. There is no evidence of myocardial edema in active AL cardiac amyloidosis. Future phenotyping studies of AL cardiac amyloidosis need to consider complementary myocardial markers that define the interstitial milieu in addition to changes in extracellular volume. (Molecular Imaging of Primary Amyloid Cardiomyopathy; NCT02641145).


Asunto(s)
Amiloidosis , Cardiomiopatías , Amiloidosis de Cadenas Ligeras de las Inmunoglobulinas , Anciano , Amiloidosis/diagnóstico por imagen , Amiloidosis/patología , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/etiología , Cardiomiopatías/patología , Medios de Contraste , Femenino , Humanos , Amiloidosis de Cadenas Ligeras de las Inmunoglobulinas/diagnóstico por imagen , Amiloidosis de Cadenas Ligeras de las Inmunoglobulinas/patología , Imagen por Resonancia Cinemagnética , Masculino , Persona de Mediana Edad , Miocardio/patología , Valor Predictivo de las Pruebas
11.
J Nucl Cardiol ; 28(5): 2004-2010, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-31758410

RESUMEN

BACKGROUND: 18F-florbetapir PET is emerging as an excellent quantitative tool to quantify cardiac light chain (AL) amyloidosis burden. The primary aim of this study was to determine interobserver reproducibility and intraobserver repeatability, defined per the recommendations of the Quantitative Imaging Biomarker Alliance technical performance group, of PET 18F-florbetapir retention index (RI) in patients with cardiac AL amyloidosis. METHODS: The study cohort comprised 37 subjects with systemic AL amyloidosis enrolled in the prospective study: Molecular Imaging of Primary Amyloid Cardiomyopathy (clinical trials.gov NCT: 02641145). Using 10 mCi of 18F-florbetapir, a 60-minute dynamic cardiac scan was acquired. Global and segmental left ventricular estimates of retention index (RI) of 18F-florbetapir were calculated (Carimas 2.9 software, Turku, Finland). RI was analyzed twice, at least 24 hours apart, by two independent observers. Intraobserver repeatability and interobserver reproducibility were evaluated using Bland-Altman plots and scatter plots with fitted linear regression curves. RESULTS: All reproducibility (interobserver, r = 0.98) and repeatability (intraobserver, R=0.99 for each observer) measures of 18F-florbetapir RI are excellent. On the Bland-Altman plots, the agreement limits for global 18F-florbetapir RI were high and ranged for reproducibility (interobserver) from - 9.3 to + 9.4% (Fig. 1), and for repeatability (observer 1 from - 10.8 to + 10.7% and from - 9.2 to + 11.4%, for observer 2). CONCLUSIONS: The present study showed excellent interobserver reproducibility and intraobserver repeatability of 18F-florbetapir PET retention index in patients with cardiac AL amyloidosis.


Asunto(s)
Amiloidosis/complicaciones , Tomografía Computarizada por Tomografía de Emisión de Positrones/normas , Anciano , Amiloidosis/diagnóstico por imagen , Amiloidosis/epidemiología , Femenino , Finlandia/epidemiología , Fluorodesoxiglucosa F18/administración & dosificación , Fluorodesoxiglucosa F18/uso terapéutico , Humanos , Masculino , Persona de Mediana Edad , Miocardio/enzimología , Miocardio/metabolismo , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía Computarizada por Tomografía de Emisión de Positrones/estadística & datos numéricos , Reproducibilidad de los Resultados
13.
JACC Cardiovasc Imaging ; 13(6): 1325-1336, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32417333

RESUMEN

OBJECTIVES: The purpose of this study was to determine phenotypes characterizing cardiac involvement in AL amyloidosis by using direct (fluorine-18-labeled florbetapir {[18F]florbetapir} positron emission tomography [PET]/computed tomography) and indirect (echocardiography and cardiac magnetic resonance [CMR]) imaging biomarkers of AL amyloidosis. BACKGROUND: Cardiac involvement in systemic light chain amyloidosis (AL) is the main determinant of prognosis and, therefore, guides management. The hypothesis of this study was that myocardial AL deposits and expansion of extracellular volume (ECV) could be identified before increases in N-terminal pro-B-type natriuretic peptide or wall thickness. METHODS: A total of 45 subjects were prospectively enrolled in 3 groups: 25 with active AL amyloidosis with cardiac involvement (active-CA), 10 with active AL amyloidosis without cardiac involvement by conventional criteria (active-non-CA), and 10 with AL amyloidosis with cardiac involvement in remission for at least 1 year (remission-CA). All subjects underwent echocardiography, CMR, and [18F]florbetapir PET/CT to evaluate cardiac amyloid burden. RESULTS: The active-CA group demonstrated the largest myocardial AL amyloid burden, quantified by [18F]florbetapir retention index (RI) 0.110 (interquartile range [IQR]: 0.078 to 0.139) min-1, and the lowest cardiac function by global longitudinal strain (GLS), median GLS -11% (IQR: -8% to -13%). The remission-CA group had expanded extracellular volume (ECV) and [18F]florbetapir RI of 0.097 (IQR: 0.070 to 0.124 min-1), and abnormal GLS despite hematologic remission for >1 year. The active-non-CA cohort had evidence of cardiac amyloid deposition by advanced imaging metrics in 50% of the subjects; cardiac involvement was identified by late gadolinium enhancement in 20%, elevated ECV in 20%, and elevated [18F]florbetapir RI in 50%. CONCLUSIONS: Evidence of cardiac amyloid infiltration was found based on direct and indirect imaging biomarkers in subjects without CA by conventional criteria. The findings from [18F]florbetapir PET imaging provided insight into the preclinical disease process and on the basis of interpretation of expanded ECV on CMR and have important implications for future research and clinical management of AL amyloidosis. (Molecular Imaging of Primary Amyloid Cardiomyopathy [MICA]; NCT02641145).


Asunto(s)
Compuestos de Anilina/administración & dosificación , Cardiomiopatías/diagnóstico por imagen , Ecocardiografía Doppler , Glicoles de Etileno/administración & dosificación , Radioisótopos de Flúor/administración & dosificación , Amiloidosis de Cadenas Ligeras de las Inmunoglobulinas/diagnóstico por imagen , Imagen por Resonancia Cinemagnética , Miocardio/patología , Tomografía Computarizada por Tomografía de Emisión de Positrones , Radiofármacos/administración & dosificación , Anciano , Cardiomiopatías/patología , Diagnóstico Precoz , Femenino , Humanos , Amiloidosis de Cadenas Ligeras de las Inmunoglobulinas/patología , Masculino , Persona de Mediana Edad , Imagen Multimodal , Valor Predictivo de las Pruebas , Estudios Prospectivos , Índice de Severidad de la Enfermedad , Estados Unidos
14.
Am J Physiol Heart Circ Physiol ; 317(3): H617-H626, 2019 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-31298558

RESUMEN

We previously described a novel "chemogenetic" animal model of heart failure that recapitulates a characteristic feature commonly found in human heart failure: chronic oxidative stress. This heart failure model uses a chemogenetic approach to activate a recombinant yeast d-amino acid oxidase in rat hearts in vivo to generate oxidative stress, which then rapidly leads to the development of a dilated cardiomyopathy. Here we apply this new model to drug testing by studying its response to treatment with the angiotensin II (ANG II) receptor blocker valsartan, administered either alone or with the neprilysin inhibitor sacubitril. Echocardiographic and [18F]fluorodeoxyglucose positron emission tomographic imaging revealed that valsartan in the presence or absence of sacubitril reverses the anatomical and metabolic remodeling induced by chronic oxidative stress. Markers of oxidative stress, mitochondrial function, and apoptosis, as well as classical heart failure biomarkers, also normalized following drug treatments despite the persistence of cardiac fibrosis. These findings provide evidence that chemogenetic heart failure is rapidly reversible by drug treatment, setting the stage for the study of novel heart failure therapeutics in this model. The ability of ANG II blockade and neprilysin inhibition to reverse heart failure induced by chronic oxidative stress identifies a central role for cardiac myocyte angiotensin receptors in the pathobiology of cardiac dysfunction caused by oxidative stress.NEW & NOTEWORTHY The chemogenetic approach allows us to distinguish cardiac myocyte-specific pathology from the pleiotropic changes that are characteristic of other "interventional" animal models of heart failure. These features of the chemogenetic heart failure model facilitate the analysis of drug effects on the progression and regression of ventricular remodeling, fibrosis, and dysfunctional signal transduction. Chemogenetic approaches will be highly informative in the study of the roles of redox stress in heart failure providing an opportunity for the identification of novel therapeutic targets.


Asunto(s)
Aminobutiratos/farmacología , Bloqueadores del Receptor Tipo 1 de Angiotensina II/farmacología , Cardiomiopatía Dilatada/tratamiento farmacológico , D-Aminoácido Oxidasa/metabolismo , Proteínas Fúngicas/metabolismo , Peróxido de Hidrógeno/metabolismo , Miocitos Cardíacos/efectos de los fármacos , Estrés Oxidativo/efectos de los fármacos , Inhibidores de Proteasas/farmacología , Tetrazoles/farmacología , Animales , Apoptosis/efectos de los fármacos , Compuestos de Bifenilo , Cardiomiopatía Dilatada/genética , Cardiomiopatía Dilatada/metabolismo , Cardiomiopatía Dilatada/fisiopatología , D-Aminoácido Oxidasa/genética , Dependovirus/genética , Modelos Animales de Enfermedad , Combinación de Medicamentos , Metabolismo Energético/efectos de los fármacos , Proteínas Fúngicas/genética , Vectores Genéticos/administración & dosificación , Inyecciones Intravenosas , Masculino , Mitocondrias Cardíacas/efectos de los fármacos , Mitocondrias Cardíacas/metabolismo , Mitocondrias Cardíacas/patología , Miocitos Cardíacos/metabolismo , Miocitos Cardíacos/patología , Neprilisina/antagonistas & inhibidores , Regiones Promotoras Genéticas , Ratas Wistar , Troponina T/genética , Valsartán , Función Ventricular Izquierda/efectos de los fármacos , Remodelación Ventricular/efectos de los fármacos
15.
JACC Cardiovasc Imaging ; 12(7 Pt 1): 1165-1173, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30121266

RESUMEN

OBJECTIVES: This study sought to test whether relative apical sparing (RELAPS) of left ventricular (LV) longitudinal strain (LS) in cardiac amyloidosis (CA) is explained by regional differences in markers of amyloid burden (18F-florbetapir uptake by positron emission tomography [PET] and/or extracellular volume fraction [ECV] by cardiac magnetic resonance (CMR)]. BACKGROUND: Further knowledge of the pathophysiological basis for RELAPS can help understand the adverse outcomes associated with apical LS impairment. METHODS: This was a prospective study of 32 subjects (age 62 ± 7 years; 50% males) with light chain CA. All subjects underwent two-dimensional echocardiography for LS estimation and 18F-florbetapir PET for quantification of LV florbetapir retention index (RI). A subset also underwent CMR (n = 22) for ECV quantification. Extracellular LV mass (LV mass*ECV) and total florbetapir binding (extracellular LV mass*florbetapir RI) were also calculated. All parameters were measured globally and regionally (base, mid, and apex). RESULTS: There was a significant base-to-apex gradient in LS (-7.4 ± 3.2% vs. -8.6 ± 4.0% vs. -20.8 ± 6.6%; p < 0.0001), maximal LV wall thickness (15.7 ± 1.9 cm vs. 15.4 ± 2.9 cm vs. 10.1 ± 2.4 cm; p < 0.0001), and LV mass (74.8 ± 21.2 g vs. 60.8 ± 17.3 g vs. 23.4 ± 6.2 g; p < 0.0001). In contrast, florbetapir RI (0.089 ± 0.03 µmol/min/g vs. 0.097 ± 0.03 µmol/min/g vs. 0.085 ± 0.03 µmol/min/g; p = 0.45) and ECV (0.53 ± 0.08 vs. 0.49 ± 0.08 vs. 0.49 ± 0.07; p = 0.15) showed no significant base-to-apex gradient in the tissue concentration or proportion of amyloid infiltration, whereas markers of total amyloid load, such as total florbetapir binding (3.4 ± 1.7 µmol/min vs. 2.8 ± 1.5 µmol/min vs. 0.93 ± 0.49 µmol/min; p < 0.0001) and extracellular LV mass (40.0 ± 15.6 g vs. 30.2 ± 10.9 g vs. 11.6 ± 3.9 g; p < 0.0001), did show a marked base-to-apex gradient. CONCLUSIONS: Segmental differences in the distribution of the total amyloid mass, rather than the proportion of amyloid deposits, appear to explain the marked regional differences in LS in CA. Although these 2 matrices are clearly related concepts, they should not be used interchangeably.


Asunto(s)
Amiloide/análisis , Amiloidosis/diagnóstico por imagen , Cardiomiopatías/diagnóstico , Imagen por Resonancia Cinemagnética , Miocardio/patología , Tomografía de Emisión de Positrones , Volumen Sistólico , Función Ventricular Izquierda , Anciano , Amiloidosis/patología , Amiloidosis/fisiopatología , Compuestos de Anilina/administración & dosificación , Cardiomiopatías/patología , Cardiomiopatías/fisiopatología , Ecocardiografía , Glicoles de Etileno/administración & dosificación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Miocardio/química , Valor Predictivo de las Pruebas , Estudios Prospectivos , Radiofármacos/administración & dosificación
16.
Med Phys ; 43(8): 4734, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27487891

RESUMEN

PURPOSE: Noise levels of brain SPECT images are highest in central regions, due to preferential attenuation of photons emitted from deep structures. To address this problem, the authors have designed a novel collimator for brain SPECT imaging that yields greatly increased sensitivity near the center of the brain without loss of resolution. This hybrid collimator consisted of ultrashort cone-beam holes in the central regions and slant-holes in the periphery (USCB). We evaluated this collimator for quantitative brain imaging tasks. METHODS: Owing to the uniqueness of the USCB collimation, the hole pattern required substantial variations in collimator parameters. To utilize the lead-casting technique, the authors designed two supporting plates to position about 37 000 hexagonal, slightly tapered pins. The holes in the supporting plates were modeled to yield the desired focal length, hole length, and septal thickness. To determine the properties of the manufactured collimator and to compute the system matrix, the authors prepared an array of point sources that covered the entire detector area. Each point source contained 32 µCi of Tc-99m at the first scan time. The array was imaged for 5 min at each of the 64 shifted locations to yield a 2-mm sampling distance, and hole parameters were calculated. The sensitivity was also measured using a point source placed along the central ray at several distances from the collimator face. High-count projection data from a five-compartment brain phantom were acquired with the three collimators on a dual-head SPECT/CT system. The authors calculated Cramer-Rao bounds on the precision of estimates of striatal and background activity concentration. In order to assess the new collimation system to detect changes in striatal activity, the authors evaluated the precision of measuring a 5% decrease in right putamen activity. The authors also reconstructed images of projection data obtained by summing data from the individual phantom compartments. RESULTS: The sensitivity of the novel cone-beam collimator varied with distance from the detector face; it was higher than that of the fan-beam collimator by factors ranging from 2.7 to 162. Examination of the projections of the point sources revealed that only a few holes were distorted or partially blocked, indicating that the intensive manual fabrication process was very successful. Better reconstructed phantom images were obtained from the USCB+FAN collimator pair than from either LEHR or FAN collimation. For the left caudate, located near the center of the brain, the detected counts were 9.8 (8.3) times higher for UCSB compared with LEHR (FAN), averaged over 60 views. The task-specific SNR for detecting a 5% decrease in putamen uptake was 7.4 for USCB and 3.2 for LEHR. CONCLUSIONS: The authors have designed and manufactured a novel collimator for brain SPECT imaging. The sensitivity is much higher than that of a fan-beam collimator. Because of differences between the manufactured collimator and its design, reconstruction of the data requires a measured system matrix. The authors have demonstrated the potential of USCB collimation for improved precision in estimating striatal uptake. The novel collimator may be useful for early detection of Parkinson's disease, and for monitoring therapy response and disease progression.


Asunto(s)
Encéfalo/diagnóstico por imagen , Relación Señal-Ruido , Tomografía Computarizada de Emisión de Fotón Único/métodos , Fantasmas de Imagen
18.
Med Phys ; 40(4): 042504, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23556920

RESUMEN

PURPOSE: The authors have previously reported the advantages of high-sensitivity single-photon emission computed tomography (SPECT) systems for imaging structures located deep inside the brain. DaTscan (Isoflupane I-123) is a dopamine transporter (DaT) imaging agent that has shown potential for early detection of Parkinson disease (PD), as well as for monitoring progression of the disease. Realizing the full potential of DaTscan requires efficient estimation of striatal uptake from SPECT images. They have evaluated two SPECT systems, a conventional dual-head gamma camera with low-energy high-resolution collimators (conventional) and a dedicated high-sensitivity multidetector cardiac imaging system (dedicated) for imaging tasks related to PD. METHODS: Cramer-Rao bounds (CRB) on precision of estimates of striatal and background activity concentrations were calculated from high-count, separate acquisitions of the compartments (right striata, left striata, background) of a striatal phantom. CRB on striatal and background activity concentration were calculated from essentially noise-free projection datasets, synthesized by scaling and summing the compartment projection datasets, for a range of total detected counts. They also calculated variances of estimates of specific-to-nonspecific binding ratios (BR) and asymmetry indices from these values using propagation of error analysis, as well as the precision of measuring changes in BR on the order of the average annual decline in early PD. RESULTS: Under typical clinical conditions, the conventional camera detected 2 M counts while the dedicated camera detected 12 M counts. Assuming a normal BR of 5, the standard deviation of BR estimates was 0.042 and 0.021 for the conventional and dedicated system, respectively. For an 8% decrease to BR = 4.6, the signal-to-noise ratio were 6.8 (conventional) and 13.3 (dedicated); for a 5% decrease, they were 4.2 (conventional) and 8.3 (dedicated). CONCLUSIONS: This implies that PD can be detected earlier with the dedicated system than with the conventional system; therefore, earlier identification of PD progression should be possible with the high-sensitivity dedicated SPECT camera.


Asunto(s)
Medios de Contraste/farmacocinética , Cuerpo Estriado/diagnóstico por imagen , Cuerpo Estriado/metabolismo , Aumento de la Imagen/instrumentación , Tomografía Computarizada de Emisión de Fotón Único/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Corazón/anatomía & histología , Humanos , Miocardio/metabolismo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
19.
Phys Med Biol ; 57(3): 685-701, 2012 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-22241591

RESUMEN

A new method of compensating for tissue-fraction and count-spillover effects, which require tissue segmentation only within a small volume surrounding the primary lesion of interest, was evaluated for SPECT imaging. Tissue-activity concentration estimates are obtained by fitting the measured projection data to a statistical model of the segmented tissue projections. Multiple realizations of two simulated human-torso phantoms, each containing 20 spherical 'tumours', 1.6 cm in diameter, with tumour-to-background ratios of 8:1 and 4:1, were simulated. Estimates of tumour- and background-activity concentration values for homogeneous as well as inhomogeneous tissue activities were compared to the standard uptake value (SUV) metrics on the basis of accuracy and precision. For perfectly registered, high-contrast, superficial lesions in a homogeneous background without scatter, the method yielded accurate (<0.4% bias) and precise (<6.1%) recovery of the simulated activity values, significantly outperforming the SUV metrics. Tissue inhomogeneities, greater tumour depth and lower contrast ratios degraded precision (up to 11.7%), but the estimates remained almost unbiased. The method was comparable in accuracy but more precise than a well-established matrix inversion approach, even when errors in tumour size and position were introduced to simulate moderate inaccuracies in segmentation and image registration. Photon scatter in the object did not significantly affect the accuracy or precision of the estimates.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Algoritmos , Simulación por Computador , Medios de Contraste/farmacología , Humanos , Imagen por Resonancia Magnética/métodos , Modelos Estadísticos , Método de Montecarlo , Distribución Normal , Fantasmas de Imagen , Fotones , Distribución de Poisson , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos
20.
IEEE Trans Med Imaging ; 31(2): 405-16, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21965196

RESUMEN

We have developed a new method of compensating for effects of partial volume and spillover in dual-modality imaging. The approach requires segmentation of just a few tissue types within a small volume-of-interest (VOI) surrounding a lesion; the algorithm estimates simultaneously, from projection data, the activity concentration within each segmented tissue inside the VOI. Measured emission projections were fitted to the sum of resolution-blurred projections of each such tissue, scaled by its unknown activity concentration, plus a global background contribution obtained by reprojection through the reconstructed image volume outside the VOI. The method was evaluated using multiple-pinhole µSPECT data simulated for the MOBY mouse phantom containing two spherical lung tumors and one liver tumor, as well as using multiple-bead phantom data acquired on µSPECT and µCT scanners. Each VOI in the simulation study was 4.8 mm (12 voxels) cubed and, depending on location, contained up to four tissues (tumor, liver, heart, lung) with different values of relative (99m)Tc concentration. All tumor activity estimates achieved bias after ∼ 15 ordered-subsets expectation maximization (OSEM) iterations (×10 subsets) , with better than 8% precision ( ≤ 25% greater than the Cramer-Rao lower bound). The projection-based fitting approach also outperformed three standardized uptake value (SUV)-like metrics, one of which was corrected for count spillover. In the bead phantom experiment, the mean ± standard deviation of the bias of VOI estimates of bead concentration were 0.9±9.5%, comparable to those of a perturbation geometric transfer matrix (pGTM) approach (-5.4±8.6%); however, VOI estimates were more stable with increasing iteration number than pGTM estimates, even in the presence of substantial axial misalignment between µCT and µSPECT image volumes.


Asunto(s)
Algoritmos , Artefactos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Neoplasias/diagnóstico por imagen , Reconocimiento de Normas Patrones Automatizadas/métodos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Animales , Ratones , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada de Emisión de Fotón Único/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...