Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Adv Healthc Mater ; : e2400529, 2024 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-38441411

RESUMEN

Effective tendon regeneration following injury is contingent on appropriate differentiation of recruited cells and deposition of mature, aligned, collagenous extracellular matrix that can withstand the extreme mechanical demands placed on the tissue. As such, myriad biomaterial approaches have been explored to provide biochemical and physical cues that encourage tenogenesis and template aligned matrix deposition in lieu of dysfunctional scar tissue formation. Fiber-reinforced hydrogels present an ideal biomaterial system toward this end given their transdermal injectability, tunable stiffness over a range amenable to tenogenic differentiation of progenitors, and capacity for modular inclusion of biochemical cues. Here, tunable and modular, fiber-reinforced, synthetic hydrogels are employed to elucidate salient microenvironmental determinants of tenogenesis and aligned collagen deposition by tendon progenitor cells. Transforming growth factor ß3 drives a cell fate switch toward pro-regenerative or pro-fibrotic phenotypes, which can be biased toward the former by culture in softer microenvironments or inhibition of the RhoA/ROCK activity. Furthermore, studies demonstrate that topographical anisotropy in fiber-reinforced hydrogels critically mediates the alignment of de novo collagen fibrils, reflecting native tendon architecture. These findings inform the design of cell-free, injectable, synthetic hydrogels for tendon tissue regeneration and, likely, that of a range of load-bearing connective tissues.

2.
Curr Osteoporos Rep ; 22(2): 290-298, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38358401

RESUMEN

PURPOSE OF REVIEW: Interfacial tissue exists throughout the body at cartilage-to-bone (osteochondral interface) and tendon-to-bone (enthesis) interfaces. Healing of interfacial tissues is a current challenge in regenerative approaches because the interface plays a critical role in stabilizing and distributing the mechanical stress between soft tissues (e.g., cartilage and tendon) and bone. The purpose of this review is to identify new directions in the field of interfacial tissue development and physiology that can guide future regenerative strategies for improving post-injury healing. RECENT FINDINGS: Cues from interfacial tissue development may guide regeneration including biological cues such as cell phenotype and growth factor signaling; structural cues such as extracellular matrix (ECM) deposition, ECM, and cell alignment; and mechanical cues such as compression, tension, shear, and the stiffness of the cellular microenvironment. In this review, we explore new discoveries in the field of interfacial biology related to ECM remodeling, cellular metabolism, and fate. Based on emergent findings across multiple disciplines, we lay out a framework for future innovations in the design of engineered strategies for interface regeneration. Many of the key mechanisms essential for interfacial tissue development and adaptation have high potential for improving outcomes in the clinic.


Asunto(s)
Regeneración Ósea , Matriz Extracelular , Humanos , Matriz Extracelular/fisiología , Regeneración Ósea/fisiología , Huesos/fisiología , Tendones/fisiología , Ingeniería de Tejidos/métodos , Cartílago/fisiología , Regeneración/fisiología , Cicatrización de Heridas/fisiología
3.
bioRxiv ; 2024 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-38106067

RESUMEN

During peri-puberty, bone growth and the attainment peak bone mass is driven predominantly by sex steroids. This is important when treating transgender and gender diverse youth, who have become increasingly present at pediatric clinics. Analogues of gonadotropin-releasing hormone (GnRH) are commonly prescribed to transgender and gender diverse youth prior to starting gender-affirming hormone therapy (GAHT). However, the impact of GnRH agonists on long bones with the addition of GAHT is relatively unknown. To explore this, we developed a trans-masculine model by introducing either GnRHa or vehicle treatment to female-born mice at a pre-pubertal age. This treatment was followed by male GAHT (testosterone, T) or control treatment three weeks later. Six weeks after T therapy, bone quality was compared between four treatment groups: Control (vehicle only), GnRHa-only, GnRHa + T, and T-only. Bone length/size, bone shape, mechanical properties, and trabecular morphology were modulated by GAHT. Independent of GnRHa administration, mice treated with T had shorter femurs, larger trabecular volume and increased trabecular number, higher trabecular bone mineral density, and wider superstructures on the surface of bone (e.g., third trochanters) when compared to control or GnRHa-only mice. In conclusion, prolonged treatment of GnRHa with subsequent GAHT treatment directly affect the composition, parameters, and morphology of the developing long bone. These findings provide insight to help guide clinical approaches to care for transgender and gender diverse youth.

5.
Sci Adv ; 9(25): eadf4683, 2023 06 23.
Artículo en Inglés | MEDLINE | ID: mdl-37352350

RESUMEN

Skeletal shape depends on the transmission of contractile muscle forces from tendon to bone across the enthesis. Loss of muscle loading impairs enthesis development, yet little is known if and how the postnatal enthesis adapts to increased loading. Here, we studied adaptations in enthesis structure and function in response to increased loading, using optogenetically induced muscle contraction in young (i.e., growth) and adult (i.e., mature) mice. Daily bouts of unilateral optogenetic loading in young mice led to radial calcaneal expansion and warping. This also led to a weaker enthesis with increased collagen damage in young tendon and enthisis, with little change in adult mice. We then used RNA sequencing to identify the pathways associated with increased mechanical loading during growth. In tendon, we found enrichment of glycolysis, focal adhesion, and cell-matrix interactions. In bone, we found enrichment of inflammation and cell cycle. Together, we demonstrate the utility of optogenetic-induced muscle contraction to elicit in vivo adaptation of the enthesis.


Asunto(s)
Tendón Calcáneo , Calcáneo , Animales , Ratones , Tendón Calcáneo/metabolismo , Optogenética , Músculos , Colágeno/metabolismo
6.
J Biomech Eng ; 145(8)2023 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-37184932

RESUMEN

Tendon degeneration is typically described as an overuse injury with little distinction made between magnitude of load (overload) and number of cycles (overuse). Further, in vivo, animal models of tendon degeneration are mostly overuse models, where tendon damage is caused by a high number of load cycles. As a result, there is a lack of knowledge of how isolated overload leads to degeneration in tendons. A surgical model of synergist ablation (SynAb) overloads the target tendon, plantaris, by ablating its synergist tendon, Achilles. The objective of this study was to evaluate the structural and functional changes that occur following overload of plantaris tendon in a rat SynAb model. Tendon cross-sectional area (CSA) and shape changes were evaluated by longitudinal MR imaging up to 8 weeks postsurgery. Tissue-scale structural changes were evaluated by semiquantified histology and second harmonic generation microscopy. Fibril level changes were evaluated with serial block face scanning electron microscopy (SBF-SEM). Functional changes were evaluated using tension tests at the tissue and microscale using a custom testing system allowing both video and microscopy imaging. At 8 weeks, overloaded plantaris tendons exhibited degenerative changes including increases in CSA, cell density, collagen damage area fraction (DAF), and fibril diameter, and decreases in collagen alignment, modulus, and yield stress. To interpret the differences between overload and overuse in tendon, we introduce a new framework for tendon remodeling and degeneration that differentiates between the inputs of overload and overuse. In summary, isolated overload induces multiscale degenerative structural and functional changes in plantaris tendon.


Asunto(s)
Tendón Calcáneo , Músculo Esquelético , Ratas , Animales , Tendón Calcáneo/patología , Colágeno , Modelos Animales , Fibras Musculares Esqueléticas
7.
Dev Dyn ; 252(9): 1180-1188, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37212424

RESUMEN

BACKGROUND: Tendons and ligaments attach to bone are essential for joint mobility and stability in vertebrates. Tendon and ligament attachments (ie, entheses) are found at bony protrusions (ie, eminences), and the shape and size of these protrusions depend on both mechanical forces and cellular cues during growth. Tendon eminences also contribute to mechanical leverage for skeletal muscle. Fibroblast growth factor receptor (FGFR) signaling plays a critical role in bone development, and Fgfr1 and Fgfr2 are highly expressed in the perichondrium and periosteum of bone where entheses can be found. RESULTS AND CONCLUSIONS: We used transgenic mice for combinatorial knockout of Fgfr1 and/or Fgfr2 in tendon/attachment progenitors (ScxCre) and measured eminence size and shape. Conditional deletion of both, but not individual, Fgfr1 and Fgfr2 in Scx progenitors led to enlarged eminences in the postnatal skeleton and shortening of long bones. In addition, Fgfr1/Fgfr2 double conditional knockout mice had more variation collagen fibril size in tendon, decreased tibial slope, and increased cell death at ligament attachments. These findings identify a role for FGFR signaling in regulating growth and maintenance of tendon/ligament attachments and the size and shape of bony eminences.


Asunto(s)
Huesos , Tendones , Animales , Ratones , Muerte Celular/genética , Ratones Noqueados , Ratones Transgénicos , Células Madre , Tendones/metabolismo
8.
bioRxiv ; 2023 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-37090593

RESUMEN

The growth of the skeleton depends on the transmission of contractile muscle forces from tendon to bone across the extracellular matrix-rich enthesis. Loss of muscle loading leads to significant impairments in enthesis development. However, little is known about how the enthesis responds to increased loading during postnatal growth. To study the cellular and matrix adaptations of the enthesis in response to increased muscle loading, we used optogenetics to induce skeletal muscle contraction and unilaterally load the Achilles tendon and enthesis in young (i.e., during growth) and adult (i.e., mature) mice. In young mice, daily bouts of unilateral optogenetic loading led to expansion of the calcaneal apophysis and growth plate, as well as increased vascularization of the normally avascular enthesis. Daily loading bouts, delivered for 3 weeks, also led to a mechanically weaker enthesis with increased molecular-level accumulation of collagen damage in young mice. However, adult mice did not exhibit impaired mechanical properties or noticeable structural adaptations to the enthesis. We then focused on the transcriptional response of the young tendon and bone following optogenetic-induced loading. After 1 or 2 weeks of loading, we identified, in tendon, transcriptional activation of canonical pathways related to glucose metabolism (glycolysis) and inhibited pathways associated with cytoskeletal remodeling (e.g., RHOA and CREB signaling). In bone, we identified activation of inflammatory signaling (e.g., NFkB and STAT3 signaling) and inhibition of ERK/MAPK and PTEN signaling. Thus, we have demonstrated the utility of optogenetic-induced skeletal muscle contraction to elicit structural, functional, and molecular adaptation of the enthesis in vivo especially during growth.

9.
FASEB J ; 37(3): e22777, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36734881

RESUMEN

The enthesis is a transitional tissue between tendon and bone that matures postnatally. The development and maturation of the enthesis involve cellular processes likened to an arrested growth plate. In this study, we explored the role of fibroblast growth factor 9 (Fgf9), a known regulator of chondrogenesis and vascularization during bone development, on the structure and function of the postnatal enthesis. First, we confirmed spatial expression of Fgf9 in the tendon and enthesis using in situ hybridization. We then used Cre-lox recombinase to conditionally knockout Fgf9 in mouse tendon and enthesis (Scx-Cre) and characterized enthesis morphology as well as mechanical properties in Fgf9ScxCre and wild-type (WT) entheses. Fgf9ScxCre mice had smaller calcaneal and humeral apophyses, thinner cortical bone at the attachment, increased cellularity, and reduced failure load in mature entheses compared to WT littermates. During postnatal development, we found reduced chondrocyte hypertrophy and disrupted type X collagen (Col X) in Fgf9ScxCre entheses. These findings support that tendon-derived Fgf9 is important for functional development of the enthesis, including its postnatal mineralization. Our findings suggest the potential role of FGF signaling during enthesis development.


Asunto(s)
Factor 9 de Crecimiento de Fibroblastos , Tendones , Ratones , Animales , Factor 9 de Crecimiento de Fibroblastos/genética , Factor 9 de Crecimiento de Fibroblastos/metabolismo , Tendones/metabolismo , Huesos , Desarrollo Óseo/genética , Condrogénesis
10.
Connect Tissue Res ; 64(3): 262-273, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36524714

RESUMEN

INTRODUCTION: Rotator cuff tear size affects clinical outcomes following rotator cuff repair and is correlated with the risk of recurrent tendon defects. This study aimed to understand if and how the initial defect size influences the structural and mechanical outcomes of the injured rotator cuff attachment in vivo. METHODS: Full-thickness punch injuries of the infraspinatus tendon-bone attachment in Long Evans rats were created to compare differences in healing outcomes between small and large defects. Biomechanical properties, gross morphology, bone remodeling, and cell and tissue morphology were assessed at both 3- and 8-weeks of healing. RESULTS: At the time of injury (no healing), large defects had decreased mechanical properties compared to small defects, and both defect sizes had decreased mechanical properties compared to intact attachments. However, the mechanical properties of the two defect groups were not significantly different from each other after 8-weeks of healing and significantly improved compared to no healing but failed to return to intact levels. Local bone volume at the defect site was higher in large compared to small defects on average and increased from 3- to 8-weeks. In contrast, bone quality decreased from 3- to 8-weeks of healing and these changes were not dependent on defect size. Qualitatively, large defects had increased collagen disorganization and neovascularization compared to small defects. DISCUSSION: In this study, we showed that both large and small defects did not regenerate the mechanical and structural integrity of the intact rat rotator cuff attachment following healing in vivo after 8 weeks of healing.


Asunto(s)
Lesiones del Manguito de los Rotadores , Manguito de los Rotadores , Ratas , Animales , Ratas Long-Evans , Tendones , Huesos , Fenómenos Biomecánicos , Modelos Animales de Enfermedad
11.
Ann Bot ; 129(6): 657-668, 2022 05 12.
Artículo en Inglés | MEDLINE | ID: mdl-35238341

RESUMEN

BACKGROUND AND AIMS: Root lodging is responsible for significant crop losses worldwide. During root lodging, roots fail by breaking, buckling or pulling out of the ground. In maize, above-ground roots, called brace roots, have been shown to reduce susceptibility to root lodging. However, the underlying structural-functional properties of brace roots that prevent root lodging are poorly defined. In this study, we quantified structural mechanical properties, geometry and bending moduli for brace roots from different whorls, genotypes and reproductive stages. METHODS: Using 3-point bend tests, we show that brace root mechanics are variable by whorl, genotype and reproductive stage. KEY RESULTS: Generally, we find that within each genotype and reproductive stage, the brace roots from the first whorl (closest to the ground) had higher structural mechanical properties and a lower bending modulus than brace roots from the second whorl. There was additional variation between genotypes and reproductive stages. Specifically, genotypes with higher structural mechanical properties also had a higher bending modulus, and senesced brace roots had lower structural mechanical properties than hydrated brace roots. CONCLUSIONS: Collectively these results highlight the importance of considering whorl-of-origin, genotype and reproductive stage for the quantification of brace root mechanics, which is important for mitigating crop loss due to root mechanical failure.


Asunto(s)
Raíces de Plantas , Zea mays , Genotipo , Raíces de Plantas/genética , Reproducción , Zea mays/genética
12.
Semin Cell Dev Biol ; 123: 64-73, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34362655

RESUMEN

Tendons are cable-like connective tissues that transfer both active and passive forces generated by skeletal muscle to bone. In the mature skeleton, the tendon-bone enthesis is an interfacial zone of transitional tissue located between two mechanically dissimilar tissues: compliant, fibrous tendon to rigid, dense mineralized bone. In this review, we focus on emerging areas in enthesis development related to its structure, function, and mechanobiology, as well as highlight established and emerging signaling pathways and physiological processes that influence the formation and adaptation of this important transitional tissue.


Asunto(s)
Huesos , Tendones , Biofisica , Músculo Esquelético , Transducción de Señal , Tendones/fisiología
13.
Dev Dyn ; 250(12): 1778-1795, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34091985

RESUMEN

BACKGROUND: The growth of most bony tuberosities, like the deltoid tuberosity (DT), rely on the transmission of muscle forces at the tendon-bone attachment during skeletal growth. Tuberosities distribute muscle forces and provide mechanical leverage at attachment sites for joint stability and mobility. The genetic factors that regulate tuberosity growth remain largely unknown. In mouse embryos with global deletion of fibroblast growth factor 9 (Fgf9), the DT size is notably enlarged. In this study, we explored the tissue-specific regulation of DT size using both global and targeted deletion of Fgf9. RESULTS: We showed that cell hypertrophy and mineralization dynamics of the DT, as well as transcriptional signatures from skeletal muscle but not bone, were influenced by the global loss of Fgf9. Loss of Fgf9 during embryonic growth led to increased chondrocyte hypertrophy and reduced cell proliferation at the DT attachment site. This endured hypertrophy and limited proliferation may explain the abnormal mineralization patterns and locally dysregulated expression of markers of endochondral development in Fgf9null attachments. We then showed that targeted deletion of Fgf9 in skeletal muscle leads to postnatal enlargement of the DT. CONCLUSION: Taken together, we discovered that Fgf9 may play an influential role in muscle-bone cross-talk during embryonic and postnatal development.


Asunto(s)
Enfermedades Óseas/genética , Factor 9 de Crecimiento de Fibroblastos/genética , Músculo Esquelético/metabolismo , Tendones/patología , Animales , Animales Recién Nacidos , Desarrollo Óseo/genética , Enfermedades Óseas/patología , Condrogénesis/genética , Embrión de Mamíferos , Femenino , Factor 9 de Crecimiento de Fibroblastos/metabolismo , Eliminación de Gen , Hipertrofia/genética , Hipertrofia/patología , Masculino , Ratones , Ratones Endogámicos C57BL , Ratones Transgénicos , Especificidad de Órganos/genética , Osteogénesis/genética , Embarazo , Tendones/embriología , Tendones/crecimiento & desarrollo , Tendones/metabolismo
14.
Connect Tissue Res ; 62(1): 15-23, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32777957

RESUMEN

Purpose: Optogenetics is an emerging alternative to traditional electrical stimulation to initiate action potentials in activatable cells both ex vivo and in vivo. Optogenetics has been commonly used in mammalian neurons and more recently, it has been adapted for activation of cardiomyocytes and skeletal muscle. Therefore, the aim of this study was to evaluate the stimulation feasibility and sustain isometric muscle contraction and limit decay for an extended period of time (1s), using non-invasive transdermal light activation of skeletal muscle (triceps surae) in vivo. MATERIALS AND METHODS: We used inducible Cre recombination to target expression of Channelrhodopsin-2 (ChR2(H134R)-EYFP) in skeletal muscle (Acta1-Cre) in mice. Fluorescent imaging confirmed that ChR2 expression is localized in skeletal muscle and does not have specific expression in sciatic nerve branch, therefore, allowing for non-nerve mediated optical stimulation of skeletal muscle. We induced muscle contraction using transdermal exposure to blue light and selected 10 Hz stimulation after controlled optimization experiments to sustain prolonged muscle contraction. RESULTS: Increasing the stimulation frequency from 10 Hz to 40 Hz increased the muscle contraction decay during prolonged 1s stimulation, highlighting frequency dependency and importance of membrane repolarization for effective light activation. Finally, we showed that optimized pulsed optogenetic stimulation of 10 Hz resulted in comparable ankle torque and contractile functionality to that of electrical stimulation. CONCLUSIONS: Our results demonstrate the feasibility and repeatability of non-invasive optogenetic stimulation of muscle in vivo and highlight optogenetic stimulation as a powerful tool for non-invasive in vivo direct activation of skeletal muscle.


Asunto(s)
Contracción Muscular , Optogenética , Animales , Channelrhodopsins/genética , Luz , Ratones , Músculo Esquelético
15.
Tissue Eng Part C Methods ; 26(10): 506-518, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32988293

RESUMEN

Tendon injuries are difficult to heal, in part, because intrinsic tendon healing, which is dominated by scar tissue formation, does not effectively regenerate the native structure and function of healthy tendon. Further, many current treatment strategies also fall short of producing regenerated tendon with the native properties of healthy tendon. There is increasing interest in the use of cell-instructive strategies to limit the intrinsic fibrotic response following injury and improve the regenerative capacity of tendon in vivo. We have established multifunctional, cell-instructive hydrogels for treating injured tendon that afford tunable control over the biomechanical, biochemical, and structural properties of the cell microenvironment. Specifically, we incorporated integrin-binding domains (RGDS) and assembled multifunctional collagen mimetic peptides that enable cell adhesion and elongation of stem cells within synthetic hydrogels of designed biomechanical properties and evaluated these materials using targeted success criteria developed for testing in mechanically demanding environments such as tendon healing. The in vitro and in situ success criteria were determined based on systematic reviews of the most commonly reported outcome measures of hydrogels for tendon repair and established standards for testing of biomaterials. We then showed, using validation experiments, that multifunctional and synthetic hydrogels meet these criteria. Specifically, these hydrogels have mechanical properties comparable to developing tendon; are noncytotoxic both in two-dimensional bolus exposure (hydrogel components) and three-dimensional encapsulation (full hydrogel); are formed, retained, and visualized within tendon defects over time (2-weeks); and provide mechanical support to tendon defects at the time of in situ gel crosslinking. Ultimately, the in vitro and in situ success criteria evaluated in this study were designed for preclinical research to rigorously test the potential to achieve successful tendon repair before in vivo testing and indicate the promise of multifunctional and synthetic hydrogels for continued translation. Impact statement Tendon healing results in a weak scar that forms due to poor cell-mediated repair of the injured tissue. Treatments that tailor the instructions experienced by cells during healing afford opportunities to regenerate the healthy tendon. Engineered cell-instructive cues, including the biomechanical, biochemical, and structural properties of the cell microenvironment, within multifunctional synthetic hydrogels are promising therapeutic strategies for tissue regeneration. In this article, the preclinical efficacy of multifunctional synthetic hydrogels for tendon repair is tested against rigorous in vitro and in situ success criteria. This study indicates the promise for continued preclinical translation of synthetic hydrogels for tissue regeneration.


Asunto(s)
Hidrogeles/farmacología , Ensayo de Materiales , Regeneración/efectos de los fármacos , Tendones/fisiología , Animales , Fenómenos Biomecánicos/efectos de los fármacos , Línea Celular , Femenino , Humanos , Polimerizacion , Ratas Long-Evans , Traumatismos de los Tendones/fisiopatología , Tendones/efectos de los fármacos
16.
J Orthop Res ; 38(8): 1866-1875, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-31965620

RESUMEN

Tendon rupture can occur at any age and is commonly treated nonoperatively, yet can result in persisting symptoms. Thus, a need exists to improve nonoperative treatments of injured tendons. Photobiomodulation (PBM) therapy has shown promise in the clinic and is hypothesized to stimulate mitochondrial-related metabolism and improve healing. However, the effect of PBM therapy on mitochondrial function during tendon maturation and healing are unknown, and its effect on tendon structure and function remain unclear. In this study, near-infrared light (980:810 nm blend, 2.5 J/cm2 ) was applied at low (30 mW/cm2 ) or high (300 mW/cm2 ) irradiance to unilateral Achilles tendons of CD-1 mice during postnatal growth (maturation) as well as adult mice with bilateral Achilles tenotomy (healing). The chronic effect of PBM therapy on tendon structure and function was determined using histology and mechanics, and the acute effect of PBM therapy on mitochondrial-related gene expression was assessed. During maturation and healing, collagen alignment, cell number, and nuclear shape were unaffected by chronic PBM therapy. We found a sex-dependent effect of PBM therapy during healing on mechanical outcomes (eg, increased stiffness and Young's modulus for PBM-treated females, and increased strain at ultimate stress for PBM-treated males). Mitochondria-related gene expression was marginally influenced by PBM therapy for both maturation and healing studies. This study was the first to implement PBM therapy during both growth and healing of the murine tendon. PBM therapy resulted in marginal and sex-dependent effects on the murine tendon. Clinical significance: PBM may be beneficial for tendon healing because functional remodeling improves without adverse effects.


Asunto(s)
Tendón Calcáneo/efectos de la radiación , Terapia por Luz de Baja Intensidad , Traumatismos de los Tendones/terapia , Tendón Calcáneo/crecimiento & desarrollo , Tendón Calcáneo/lesiones , Tendón Calcáneo/metabolismo , Animales , Femenino , Expresión Génica/efectos de la radiación , Masculino , Ratones , Mitocondrias/metabolismo
17.
Curr Tissue Microenviron Rep ; 1(2): 31-40, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33585822

RESUMEN

PURPOSE OF REVIEW: The purpose of this review is to describe the mechanobiological mechanisms of tendon repair as well as outline current and emerging tools in mechanobiology that might be useful for improving tendon healing and regeneration. Over 30 million musculoskeletal injuries are reported in the US per year and nearly 50% involve soft tissue injuries to tendons and ligaments. Yet current therapeutic strategies for treating tendon injuries are not always successful in regenerating and returning function of the healing tendon. RECENT FINDINGS: The use of rehabilitative strategies to control the motion and transmission of mechanical loads to repairing tendons following surgical reattachment is beneficial for some, but not all, tendon repairs. Scaffolds that are designed to recapitulate properties of developing tissues show potential to guide the mechanical and biological healing of tendon following rupture. The incorporation of biomaterials to control alignment and reintegration, as well as promote scar-less healing, are also promising. Improving our understanding of damage thresholds for resident cells and how these cells respond to bioelectrical cues may offer promising steps forward in the field of tendon regeneration. SUMMARY: The field of orthopaedics continues to advance and improve with the development of regenerative approaches for musculoskeletal injuries, especially for tendon, and deeper exploration in this area will lead to improved clinical outcomes.

18.
J Mech Behav Biomed Mater ; 97: 65-73, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31100487

RESUMEN

Agarose phantoms are one type of phantom commonly used in developing in vivo brain magnetic resonance elastography (MRE) sequences because they are inexpensive and easy to work with, store, and dispose of; however, protocols for creating agarose phantoms are non-standardized and often result in inconsistent phantoms with significant variability in mechanical properties. Many magnetic resonance imaging (MRI) and ultrasound studies use phantoms, but often these phantoms are not tailored for desired mechanical properties and as such are too stiff or not mechanically consistent enough to be used in MRE. In this work, we conducted a systematic study of agarose phantom creation parameters to identify those factors that are most conducive to producing mechanically consistent agarose phantoms for MRE research. We found that cooling rate and liquid temperature affected phantom homogeneity. Phantom stiffness is affected by agar concentration (quadratically), by final liquid temperature and salt content in phantoms, and by the interaction of these two metrics each with stir rate. We captured and quantified the implied relationships with a regression model that can be used to estimate stiffness of resulting phantoms. Additionally, we characterized repeatability, stability over time, impact on MR signal parameters, and differences in agar gel microstructure. This protocol and regression model should prove beneficial in future MRE development studies that use phantoms to determine stiffness measurement accuracy.


Asunto(s)
Encéfalo/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad , Imagen por Resonancia Magnética , Fantasmas de Imagen , Sefarosa/química , Agar/química , Algoritmos , Humanos , Ensayo de Materiales , Movimiento (Física) , Análisis de Regresión , Sales (Química)/química , Temperatura
19.
J Orthop Res ; 37(1): 151-160, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30259572

RESUMEN

Acetabular dysplasia is a common, multi-etiological, pre-osteoarthritic (OA) feature that can lead to pain and instability of the young adult hip. Despite the clinical significance of acetabular dysplasia, there is a paucity of small animal models to investigate structural and functional changes that mediate morphology of the dysplastic hip and drive the subsequent OA cascade. Utilizing a novel murine model developed in our laboratory, this study investigated the role of surgically induced unilateral instability of the postnatal hip on the initiation and progression of acetabular dysplasia and impingement up to 8-weeks post-injury. C57BL6 mice were used to develop titrated levels of hip instability (i.e., mild, moderate, and severe instabillity or femoral head resection) at weaning. Joint shape, acetabular coverage, histomorphology, and statistical shape modeling were used to assess quality of the hip following 8 weeks of destabilization. Acetabular coverage was reduced following severe, but not moderate, instability. Moderate instability induced lateralization of the femur without dislocation, whereas severe instability led to complete dislocation and pseudoacetabulae formation. Mild instability did not result in morphological changes to the hip. Removal of the femoral head led to reduced hip joint space volume. These data support the notion that hip instability, driven by mechanical loss-of-function of soft connective tissue, can induce morphometric changes in the growing mouse hip. This work developed a new mouse model to study hip health in the murine adolescent hip and is a useful tool for investigating the mechanical and structural adaptations to hip instability during growth. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res.


Asunto(s)
Modelos Animales de Enfermedad , Luxación de la Cadera , Animales , Femenino , Articulación de la Cadera/patología , Masculino , Ratones Endogámicos C57BL
20.
Connect Tissue Res ; 59(5): 437-446, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29874950

RESUMEN

PURPOSE: Identify the healing outcomes following a partial-width, full-thickness injury to the rotator cuff tendon-bone attachment and establish if the adult attachment can regenerate the morphology of the healthy attachment. HYPOTHESIS: We hypothesized that a partial-width injury to the attachment would heal via fibrosis and bone remodeling, resulting in increased cellularity and extra-cellular matrix deposition, reduced bone volume (BV), osteoclast presence, and decreased collagen organization compared to shams. MATERIALS AND METHODS: A partial-width injury was made using a biopsy punch at the center one-third of the rat infraspinatus attachment. Contralateral limbs underwent a sham operation. Rats were sacrificed at 3 and 8 weeks after injury for analyses. Analyses performed at each time point included cellularity (Hematoxylin & Eosin), ECM deposition (Masson's Trichrome), BV (micro-computed tomography; microCT), osteoclast activity (Tartrate Resistant Acid Phosphatase; TRAP), and collagen fibril organization (Picrosirius Red). Injured and sham shoulders were compared at both 3 and 8 weeks using paired, two-way ANOVAs with repeated measures (Sidak's correction for multiple comparisons). RESULTS: Cellularity and ECM deposition increased at both 3 and 8 weeks compared to sham contralateral attachments. BV decreased and osteoclast presence increased at both 3 and 8 weeks compared to sham contralateral limbs. Collagen fibril organization was reduced at 3 weeks after injury compared to 3-week sham attachments. CONCLUSIONS: These findings suggest that a partial-width injury to the rotator cuff attachment does not fully regenerate the native structure of the healthy attachment. The injury model healed via scar-like fibrosis and did not propagate into a full-width tear after 8 weeks of healing.


Asunto(s)
Lesiones del Manguito de los Rotadores/patología , Manguito de los Rotadores/patología , Cicatrización de Heridas , Animales , Fenómenos Biomecánicos , Huesos/patología , Recuento de Células , Femenino , Masculino , Tamaño de los Órganos , Ratas Sprague-Dawley , Manguito de los Rotadores/diagnóstico por imagen , Lesiones del Manguito de los Rotadores/diagnóstico por imagen , Microtomografía por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA