Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
3.
Curr Biol ; 33(18): 3985-3991.e4, 2023 09 25.
Artículo en Inglés | MEDLINE | ID: mdl-37643623

RESUMEN

Despite lacking ears, the nematode C. elegans senses airborne sound and engages in phonotaxis behavior, enabling it to locate and avoid sound sources.1 How worms sense sound, however, is not well understood. Here, we report an interesting observation that worms respond only to sounds emitted by small but not large speakers, indicating that they preferentially respond to localized sound sources. Notably, sounds emitted by small speakers form a sharp sound pressure gradient across the worm body, while sounds from large speakers do not, suggesting that worms sense sound pressure gradients rather than absolute sound pressure. Analysis of phonotaxis behavior, sound-evoked skin vibration, and sound-sensitive neuron activities further support this model. We suggest that the ability to sense sound pressure gradients provides a potential mechanism for worms to distinguish sounds generated by their predators, which are typically small animals, from those produced by large animals or background noise. As vertebrate cochlea and some insect ears can also detect sound pressure gradients, our results reveal that sensing of sound pressure gradients may represent a common mechanism in auditory sensation across animal phyla. VIDEO ABSTRACT.


Asunto(s)
Caenorhabditis elegans , Sonido , Animales , Vibración , Ruido , Cóclea
4.
J Cosmet Dermatol ; 22(12): 3375-3378, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37218601

RESUMEN

BACKGROUND: In any dermatologic procedure, patient acceptance of treatment is heavily influenced by intraprocedural pain. Intralesional triamcinolone injections are very important in keloid scar and nodulocystic acne treatment. However, the main problem of needle-stick procedures is pain. Cryoanesthesia is ideally intended to cool only the epidermis during treatment and has advantage which did not require application time. AIMS: The aim of this study was to investigate the pain-reducing effect and safety of CryoVIVE® (newly introduced cryoanesthesia device) during triamcinolone injections for nodulocystic acne in actual clinical settings. PATIENTS/METHODS: In this two-staged, non-randomized clinical trial, a total of 64 subjects underwent intralesional triamcinolone injections for their acne lesions with cold anesthesia using CryoVIVE®. The pain intensity was assessed with Visual Analogue Scale (VAS) scores. Safety profile was also evaluated. RESULTS: The mean pain VAS scores on the lesion with and without cold anesthesia were 3.667 and 5.933, respectively (p = 0.0001). No side effects, discoloration, and scarring were observed. CONCLUSION: In conclusion, the anesthetic use of CryoVIVE® with intralesional corticosteroid injections is a practical and well-tolerated modality.


Asunto(s)
Acné Vulgar , Anestesia , Queloide , Humanos , Triamcinolona Acetonida , Dolor/prevención & control , Dolor/inducido químicamente , Queloide/tratamiento farmacológico , Inyecciones Intralesiones , Acné Vulgar/complicaciones , Acné Vulgar/tratamiento farmacológico , Esteroides , Resultado del Tratamiento
5.
Nature ; 617(7960): 287-291, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37138079

RESUMEN

MicroLED displays have been in the spotlight as the next-generation displays owing to their various advantages, including long lifetime and high brightness compared with organic light-emitting diode (OLED) displays. As a result, microLED technology1,2 is being commercialized for large-screen displays such as digital signage and active R&D programmes are being carried out for other applications, such as augmented reality3, flexible displays4 and biological imaging5. However, substantial obstacles in transfer technology, namely, high throughput, high yield and production scalability up to Generation 10+ (2,940 × 3,370 mm2) glass sizes, need to be overcome so that microLEDs can enter mainstream product markets and compete with liquid-crystal displays and OLED displays. Here we present a new transfer method based on fluidic self-assembly (FSA) technology, named magnetic-force-assisted dielectrophoretic self-assembly technology (MDSAT), which combines magnetic and dielectrophoresis (DEP) forces to achieve a simultaneous red, green and blue (RGB) LED transfer yield of 99.99% within 15 min. By embedding nickel, a ferromagnetic material, in the microLEDs, their movements were controlled by using magnets, and by applying localized DEP force centred around the receptor holes, these microLEDs were effectively captured and assembled in the receptor site. Furthermore, concurrent assembly of RGB LEDs were demonstrated through shape matching between microLEDs and receptors. Finally, a light-emitting panel was fabricated, showing damage-free transfer characteristics and uniform RGB electroluminescence emission, demonstrating our MDSAT method to be an excellent transfer technology candidate for high-volume production of mainstream commercial products.

6.
Res Sq ; 2023 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-37214802

RESUMEN

Functional ultrasound imaging enables sensitive, high-resolution imaging of neural activity in freely behaving animals and human patients. However, the skull acts as an aberrating and absorbing layer for sound waves, leading to most functional ultrasound experiments being conducted after skull removal. In pre-clinical settings, craniotomies are often covered with a polymethylpentene film, which offers limited longitudinal imaging, due to the film's poor conformability, and limited mechanical protection, due to the film's low stiffness. Here, we introduce a skull replacement consisting of a microstructured, conformal acoustic window based on mechanical metamaterials, designed to offer high stiffness-to-density ratio and sonotransparency. We test the acoustic window in vivo, via terminal and survival experiments on small animals. Long-term biocompatibility and lasting signal sensitivity are demonstrated over a long period of time (> 4 months) by conducting ultrasound imaging in mouse models implanted with the metamaterial skull prosthesis.

7.
Indian J Dermatol ; 67(2): 204, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36092232

RESUMEN

Background: Pigmentary skin disorders impair the quality of life, leading to the development of therapeutic modalities. However, these treatments should focus more on effectiveness and safety. Aims and Objectives: To evaluate the effect of a temperature-adjustable cryotherapy device on the expression of pigmentation-related biomarkers. Methods and Results: A temperature- and time-adjustable cryotherapy device was employed to improve 200 mJ UVB-induced pigmentation on mice at -5°C (for 5, 10 or 20 s), 0°C (for 5, 10 or 20 s), 5°C (for 5, 10 or 20 s), or 10°C (for 5, 10 or 20 s). Expression of pigmentation-related biomarkers, such as tyrosinase, c-kit, melanocortin 1 receptor and microphthalmia-associated transcription factor before and after treatment with the cryotherapy device was investigated with real-time polymerase chain reaction and immunohistochemistry. Results: Expression of pigmentation-related biomarkers was decreased after the treatment of the temperature-adjustable cryotherapy device. Gene expression of the pigmentation-related biomarkers was decreased under the above conditions with some exception. Protein expression of the pigmentation-related biomarkers showed decreased tendency under the conditions with some exceptions. Conclusion: The temperature-adjustable cryotherapy device used in this study reduced the expression of pigmentation-related biomarkers on mice and may be used to treat patients with skin pigmentation.

8.
Dermatol Ther ; 35(2): e15240, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34854186

RESUMEN

Cryotherapy (or cryosurgery) has been performed to treat various skin lesions in the field of dermatology; however, to the best of our knowledge, no study has investigated its efficacy and safety for benign pigmented lesions. Therefore, we conducted a split-face study to evaluate the efficacy and safety of cryotherapy in the treatment of benign pigmented lesions. A total of five subjects were included. Picosecond laser therapy was performed to treat the whole face and cryotherapy for half the face. Four weeks after completing the treatment sessions, patients showed more clinical improvement on the laser and cryotherapy combination treatment side than on the laser-only side, with no adverse events. Our study demonstrated that cryotherapy is a potential adjuvant therapeutic modality for benign pigmented lesions.


Asunto(s)
Láseres de Estado Sólido , Neodimio , Aluminio , Crioterapia/efectos adversos , Humanos , Láseres de Estado Sólido/uso terapéutico , Resultado del Tratamiento , Itrio
9.
Clin Ophthalmol ; 15: 4659-4666, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34916777

RESUMEN

PURPOSE: To evaluate the safety and efficacy of a novel medical device to provide cooling anesthesia to the eye as local anesthesia for intravitreal injections. STUDY DESIGN: First in human, open-label study of 43 subjects assessed at three different doses: -10°C for 20 seconds (group 1), -15°C for 15 seconds (group 2), and -15°C for 20 seconds (group 3). Main outcome measures were safety and pain of injection using a numeric rating scale (NRS). RESULTS: Cooling anesthesia did not result in any serious ocular adverse events. One grade 1 adverse event was a vasovagal response during cooling administration which resolved immediately after cooling. Mean NRS scores at the time of injection for each group ranged from 2.5 to 4.3 There was a statistically significant difference between pain scores of the 3 groups at injection in aggregate but not in pairwise comparisons (P value = 0.047). There was a statistically significant decrease in pain from injection to 5 minutes post injection in all groups (P value = 0.00008, 0.003, 0.0005 for groups 1, 2, 3, respectively) as well as from 5 minutes to 24-48 hours (P value = 0.00001, 0.018, and 0.0545 for groups 1, 2, 3, respectively). CONCLUSION: The rapid cooling anesthesia device was well tolerated for achieving local anesthesia among patients receiving intravitreal injections with no serious ocular adverse events.

10.
Anal Chem ; 93(42): 14169-14177, 2021 10 26.
Artículo en Inglés | MEDLINE | ID: mdl-34644049

RESUMEN

Diffusioosmosis (DO) results from ion transport near charged surfaces in the presence of electrolyte gradients and is critical in nanofluidic systems. However, DO has not yet been comprehensively studied because nanofabrication materials have limitations of low throughput and difficult quantification. Herein, we describe a self-assembled particle membrane (SAPM)-integrated microfluidic platform that can modulate the material properties (e.g., zeta-potential) and transport flux of nanopores. We quantify the effect of the zeta-potential on DO by measuring the electrical signals across three different nanopores/nanochannels of the SAPM. We then empirically quantify the effects of the temperature and ionic strength of the electrolytes on DO and reveal a nonlinear relationship with DO-driven ion transport; the ionic strengths govern the DO- or diffusion-effective ion transport phenomena. Finally, we demonstrate DO-driven electric power generation with enhanced performance as a potential application under optimized experimental conditions.


Asunto(s)
Nanoporos , Difusión , Electrólitos , Transporte Iónico , Temperatura
11.
Polymers (Basel) ; 13(4)2021 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-33670700

RESUMEN

Functionalized graphene-polymer nanocomposites have gained significant attention for their enhanced mechanical, thermal, and antibacterial properties, but the requirement of multi-step processes or hazardous reducing agents to functionalize graphene limits their current applications. Here, we present a single-step synthesis of thermally reduced graphene oxide (TrGO) based on shellac, which is a low-cost biopolymer that can be employed to produce poly(vinyl alcohol) (PVA)/TrGO nanocomposites (PVA-TrGO). The concentration of TrGO varied from 0.1 to 2.0 wt.%, and the critical concentration of homogeneous TrGO dispersion was observed to be 1.5 wt.%, below which strong interfacial molecular interactions between the TrGO and the PVA matrix resulted in improved thermal and mechanical properties. At 1.5 wt.% filler loading, the tensile strength and modulus of the PVA-TrGO nanocomposite were increased by 98.7% and 97.4%, respectively, while the storage modulus was increased by 69%. Furthermore, the nanocomposite was 96% more effective in preventing bacterial colonization relative to the neat PVA matrix. The present findings indicate that TrGO can be considered a promising material for potential applications in biomedical devices.

12.
Sci Adv ; 7(1)2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33523863

RESUMEN

We report a versatile method to make liquid metal composites by vigorously mixing gallium (Ga) with non-metallic particles of graphene oxide (G-O), graphite, diamond, and silicon carbide that display either paste or putty-like behavior depending on the volume fraction. Unlike Ga, the putty-like mixtures can be kneaded and rolled on any surface without leaving residue. By changing temperature, these materials can be stiffened, softened, and, for the G-O-containing composite, even made porous. The gallium putty (GalP) containing reduced G-O (rG-O) has excellent electromagnetic interference shielding effectiveness. GalP with diamond filler has excellent thermal conductivity and heat transfer superior to a commercial liquid metal-based thermal paste. Composites can also be formed from eutectic alloys of Ga including Ga-In (EGaIn), Ga-Sn (EGaSn), and Ga-In-Sn (EGaInSn or Galinstan). The versatility of our approach allows a variety of fillers to be incorporated in liquid metals, potentially allowing filler-specific "fit for purpose" materials.

13.
Nano Lett ; 21(1): 337-343, 2021 01 13.
Artículo en Inglés | MEDLINE | ID: mdl-33227203

RESUMEN

Since the emergence of the COVID-19 pandemic outbreak, the increasing demand and disposal of surgical masks has resulted in significant economic costs and environmental impacts. Here, we applied a dual-channel spray-assisted nanocoating hybrid of shellac/copper nanoparticles (CuNPs) to a nonwoven surgical mask, thereby increasing the hydrophobicity of the surface and repelling aqueous droplets. The resulting surface showed outstanding photoactivity (combined photocatalytic and photothermal properties) for antimicrobial action, conferring reusability and self-sterilizing ability to the masks. Under solar illumination, the temperature of this photoactive antiviral mask (PAM) rapidly increased to >70 °C, generating a high level of free radicals that disrupted the membrane of nanosized (∼100 nm) virus-like particles and made the masks self-cleaning and reusable. This PAM design can provide significant protection against the transmission of viral aerosols in the fight against the COVID-19 pandemic.


Asunto(s)
Antivirales/química , COVID-19/prevención & control , Cobre/química , Máscaras/virología , Nanopartículas del Metal/química , Esterilización/métodos , Catálisis , Humanos , Interacciones Hidrofóbicas e Hidrofílicas , Procesos Fotoquímicos , SARS-CoV-2/aislamiento & purificación , Temperatura
14.
Mater Sci Eng C Mater Biol Appl ; 108: 110465, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31924022

RESUMEN

A biocompatible, cost-effective, and scalable reduced graphene oxide (rGO) film was obtained from shellac using thermal treatment and its structural, chemical, and electrical properties were investigated. This thermally-decomposed rGO (TrGO) film exhibited good crystallinity, low sheet resistance, and high carbon content. TrGO flakes obtained from the film were dispersed and drop cast onto indium tin oxide/glass electrodes to fabricate label-free electrochemical immunosensors for the quantitative detection of the influenza virus H1N1 via electrochemical impedance spectroscopy. These sensors exhibited high stability and reproducibility, both possibly ascribable to the high adhesion of TrGO due to its phenolic-OH moiety; the limits of detection were 26 and 33 plaque-forming units, respectively, in phosphate-buffered saline and diluted saliva. These cost-effective TrGO-based sensors showed great potential as reliable and robust nanomaterial-based biosensors for widespread clinical applications.


Asunto(s)
Técnicas Biosensibles , Espectroscopía Dieléctrica , Grafito/química , Subtipo H1N1 del Virus de la Influenza A , Compuestos de Estaño/química , Límite de Detección
15.
ACS Appl Mater Interfaces ; 12(1): 1151-1158, 2020 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-31808674

RESUMEN

Intercorrelation of thermoelectric properties of a doped conjugated semiconducting polymer (PIDF-BT) with charge carrier density, conductive morphology, and crystallinity are systematically investigated. Upon being doped with F4-TCNQ by the sequential doping method, PIDF-BT exhibited a high electrical conductivity over 210 S cm-1. The significant enhancement of electrical conductivity resulted from a high charge carrier density, which is attributed to the effective charge-transfer-based integer doping between PIDF-BT and dopant molecules. Based on the systemic characterization on the optical, electrical, and structural properties of doped PIDF-BT annealed at different temperatures, we investigated the characteristic correlations between thermoelectric properties of PIDF-BT films and their four-probe electrical conductivity, charge carrier density, and charge carrier mobility obtained from AC Hall effect measurements. This study revealed that exercising fine control over the crystallinity and conductive migration of the conjugated polymer films can be a strategic approach to suppressing the degradation of the Seebeck coefficient at high charge carrier density and ultimately to maximizing the power factors of organic thermoelectric devices.

16.
Cell ; 178(6): 1375-1386.e11, 2019 09 05.
Artículo en Inglés | MEDLINE | ID: mdl-31474366

RESUMEN

In search of the molecular identities of cold-sensing receptors, we carried out an unbiased genetic screen for cold-sensing mutants in C. elegans and isolated a mutant allele of glr-3 gene that encodes a kainate-type glutamate receptor. While glutamate receptors are best known to transmit chemical synaptic signals in the CNS, we show that GLR-3 senses cold in the peripheral sensory neuron ASER to trigger cold-avoidance behavior. GLR-3 transmits cold signals via G protein signaling independently of its glutamate-gated channel function, suggesting GLR-3 as a metabotropic cold receptor. The vertebrate GLR-3 homolog GluK2 from zebrafish, mouse, and human can all function as a cold receptor in heterologous systems. Mouse DRG sensory neurons express GluK2, and GluK2 knockdown in these neurons suppresses their sensitivity to cold but not cool temperatures. Our study identifies an evolutionarily conserved cold receptor, revealing that a central chemical receptor unexpectedly functions as a thermal receptor in the periphery.


Asunto(s)
Proteínas de Caenorhabditis elegans/fisiología , Caenorhabditis elegans/genética , Receptores de Glutamato/fisiología , Receptores de Ácido Kaínico/fisiología , Receptores de Glutamato Metabotrópico/fisiología , Sensación Térmica/fisiología , Animales , Células CHO , Proteínas de Caenorhabditis elegans/genética , Frío , Cricetulus , Humanos , Ratones , Neuronas/metabolismo , Receptores de Glutamato/genética , Receptores de Ácido Kaínico/genética , Receptores de Glutamato Metabotrópico/genética , Sensación Térmica/genética
17.
Adv Mater ; 31(29): e1903039, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31155773

RESUMEN

A macroscopic film (2.5 cm × 2.5 cm) made by layer-by-layer assembly of 100 single-layer polycrystalline graphene films is reported. The graphene layers are transferred and stacked one by one using a wet process that leads to layer defects and interstitial contamination. Heat-treatment of the sample up to 2800 °C results in the removal of interstitial contaminants and the healing of graphene layer defects. The resulting stacked graphene sample is a freestanding film with near-perfect in-plane crystallinity but a mixed stacking order through the thickness, which separates it from all existing carbon materials. Macroscale tensile tests yields maximum values of 62 GPa for the Young's modulus and 0.70 GPa for the fracture strength, significantly higher than has been reported for any other macroscale carbon films; microscale tensile tests yield maximum values of 290 GPa for the Young's modulus and 5.8 GPa for the fracture strength. The measured in-plane thermal conductivity is exceptionally high, 2292 ± 159 W m-1 K-1 while in-plane electrical conductivity is 2.2 × 105 S m-1 . The high performance of these films is attributed to the combination of the high in-plane crystalline order and unique stacking configuration through the thickness.

18.
Sci Adv ; 3(7): e1700342, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28782022

RESUMEN

High thermal conductivity is critical for many applications of polymers (for example, packaging of light-emitting diodes), in which heat must be dissipated efficiently to maintain the functionality and reliability of a system. Whereas uniaxially extended chain morphology has been shown to significantly enhance thermal conductivity in individual polymer chains and fibers, bulk polymers with coiled and entangled chains have low thermal conductivities (0.1 to 0.4 W m-1 K-1). We demonstrate that systematic ionization of a weak anionic polyelectrolyte, polyacrylic acid (PAA), resulting in extended and stiffened polymer chains with superior packing, can significantly enhance its thermal conductivity. Cross-plane thermal conductivity in spin-cast amorphous films steadily grows with PAA degree of ionization, reaching up to ~1.2 W m-1 K-1, which is on par with that of glass and about six times higher than that of most amorphous polymers, suggesting a new unexplored molecular engineering strategy to achieve high thermal conductivities in amorphous bulk polymers.

19.
ACS Omega ; 2(3): 1009-1018, 2017 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-31457482

RESUMEN

The effects of exchange current density, Tafel slope, system resistance, electrode area, light intensity, and solar cell efficiency were systematically decoupled at the converter-assisted photovoltaic-water electrolysis system. This allows key determinants of overall efficiency to be identified. On the basis of this model, 26.5% single-junction GaAs solar cell was combined with a membrane-electrode-assembled electrolysis cell (EC) using the dc/dc converting technology. As a result, we have achieved a solar-to-hydrogen conversion efficiency of 20.6% on a prototype scale and demonstrated light intensity tracking optimization to maintain high efficiency. We believe that this study will provide design principles for combining solar cells, ECs, and new catalysts and can be generalized to other solar conversion chemical devices while minimizing their power loss during the conversion of electrical energy into fuel.

20.
Nat Commun ; 6: 8947, 2015 Dec 02.
Artículo en Inglés | MEDLINE | ID: mdl-26626796

RESUMEN

Metal-free organic phosphorescent materials are attractive alternatives to the predominantly used organometallic phosphors but are generally dimmer and are relatively rare, as, without heavy-metal atoms, spin-orbit coupling is less efficient and phosphorescence usually cannot compete with radiationless relaxation processes. Here we present a general design rule and a method to effectively reduce radiationless transitions and hence greatly enhance phosphorescence efficiency of metal-free organic materials in a variety of amorphous polymer matrices, based on the restriction of molecular motions in the proximity of embedded phosphors. Covalent cross-linking between phosphors and polymer matrices via Diels-Alder click chemistry is devised as a method. A sharp increase in phosphorescence quantum efficiency is observed in a variety of polymer matrices with this method, which is ca. two to five times higher than that of phosphor-doped polymer systems having no such covalent linkage.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...