Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Bioengineering (Basel) ; 10(11)2023 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-38002374

RESUMEN

The purpose of this study was to investigate the effects of different peri-implantitis treatment methods (Er,Cr:YSGG laser, diode laser, and electrocautery) on various titanium implant surfaces: machined; sandblasted, large-grit, and acid-etched; and femtosecond laser-treated surfaces. Grade 4 titanium (Ti) disks, with a diameter of 10 mm and a thickness of 1 mm, were fabricated and treated using the aforementioned techniques. Subsequently, each treated group of disks underwent different peri-implantitis treatment methods: Er,Cr:YSGG laser (Biolase, Inc., Foothill Ranch, CA, USA), diode laser (Biolase, Inc., Foothill Ranch, CA, USA), and electrocautery (Ellman, Hicksville, NY, USA). Scanning electron microscopy, energy-dispersive X-ray spectroscopy, and wettability were used to characterize the chemical compositions and surfaces of the treated titanium surfaces. Significant changes in surface roughness were observed in both the electrocautery (Sa value of machined surface = 0.469, SLA surface = 1.569, femtosecond laser surface = 1.741, and p = 0.025) and Er,Cr:YSGG laser (Ra value of machined surface = 1.034, SLA surface = 1.380, femtosecond laser surface = 1.437, and p = 0.025) groups. On femtosecond laser-treated titanium implant surfaces, all three treatment methods significantly reduced the surface contact angle (control = 82.2°, diode laser = 74.3°, Er,Cr:YSGG laser = 73.8°, electrocautery = 76.2°, and p = 0.039). Overall, Er,Cr:YSGG laser and electrocautery treatments significantly altered the surface roughness of titanium implant surfaces. As a result of surface composition after different peri-implantitis treatment methods, relative to the diode laser and electrocautery, the Er,Cr:YSGG laser increased oxygen concentration. The most dramatic change was observed after Er:Cr;YSGG laser treatment, urging caution for clinical applications. Changes in surface composition and wettability were observed but were not statistically significant. Further research is needed to understand the biological implications of these peri-implantitis treatment methods.

2.
J Funct Biomater ; 14(10)2023 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-37888151

RESUMEN

(1) Background: The purpose of this study was to evaluate how a zirconia implant surface treated with laser technology affects the degree of biofilm formation. (2) Methods: Experimental titanium (Ti) disks were produced that were sandblasted with large grit and acid-etched (T), and they were compared with zirconia (ZrO2) discs with a machined (M) surface topography; a hydrophilic surface topography with a femtosecond laser (HF); and a hydrophobic surface topography with a nanosecond laser (HN) (N = 12 per surface group). An in vitro three-species biofilm sample (Aggregatibacter actinomycetemcomitans (Aa), Porphyromonas gingivalis (Pg), Prevotella intermedia (Pi)) was applied to each disc type, and bacterial adhesion was assessed after 48 and 72 h of incubation using an anaerobic flow chamber model. Statistical significance was determined using the Kruskal-Wallis H test, with Bonferroni correction used for the post-hoc test (α = 0.05). (3) Results: Compared to the T group, the M group exhibited more than twice as many viable bacterial counts in the three-species biofilm samples (p < 0.05). In comparison to the T group, the HF group had significantly higher viable bacterial counts in certain biofilm samples at 48 h (Aa and Pi) and 72 h (Pi) (p < 0.05). The HN group had higher viable bacterial counts in Pi at 48 h (5400 CFU/mL, p < 0.05) than the T group (4500 CFU/mL), while showing significantly lower viable bacterial counts in Pg at both 48 (3010 CFU/mL) and 72 h (3190 CFU/mL) (p < 0.05). (4) Conclusions: The surface treatment method for zirconia discs greatly influences biofilm formation. Notably, hydrophobic surface treatment using a nanosecond laser was particularly effective at inhibiting Pg growth.

3.
J Funct Biomater ; 14(10)2023 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-37888167

RESUMEN

This study evaluated the effects of various mechanical debridement methods on the surface roughness (Ra) of dental implants, comparing femtosecond laser-treated surfaces with conventionally machined and sandblasted with large-grit sand and acid-etched (SLA) implant surfaces. The fabrication of grade 4 titanium (Ti) disks (10 mm in diameter and 1 mm thick) and the SLA process were carried out by a dental implant manufacturer (DENTIS; Daegu, Republic of Korea). Subsequently, disk surfaces were treated with various methods: machined, SLA, and femtosecond laser. Disks of each surface-treated group were post-treated with mechanical debridement methods: Ti curettes, ultrasonic scaler, and Ti brushes. Scanning electron microscopy, Ra, and wettability were evaluated. Statistical analysis was performed using the Kruskal-Wallis H test, with post-hoc analyses conducted using the Bonferroni correction (α = 0.05). In the control group, no significant difference in Ra was observed between the machined and SLA groups. However, femtosecond laser-treated surfaces exhibited higher Ra than SLA surfaces (p < 0.05). The application of Ti curette or brushing further accentuated the roughness of the femtosecond laser-treated surfaces, whereas scaling reduced the Ra in SLA surfaces. Femtosecond laser-treated implant surfaces, with their unique roughness and compositional attributes, are promising alternatives in dental implant surface treatments.

4.
Micromachines (Basel) ; 13(8)2022 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-36014154

RESUMEN

The trap states and defects near the active region in deep-ultraviolet (DUV) light-emitting diodes (LED) were investigated through wavelength-dependent photocurrent spectroscopy. We observed anomalous photocurrent reversal and its temporal recovery in AlGaN-based DUV LEDs as the wavelength of illuminating light varied from DUV to visible. The wavelength-dependent photocurrent measurements were performed on 265 nm-emitting DUV LEDs under zero-bias conditions. Sharp near-band-edge (~265 nm) absorption was observed in addition to broad (300-800 nm) visible-range absorption peaks in the photocurrent spectrum, while the current direction of these two peaks were opposite to each other. In addition, the current direction of the photocurrent in the visible wavelength range was reversed when a certain forward bias was applied. This bias-induced current reversal displayed a slow recovery time (~6 h) when the applied forward voltage was removed. Furthermore, the recovery time showed strong temperature dependency and was faster as the sample temperature increased. This result can be consistently explained by the presence of hole traps at the electron-blocking layer and the band bending caused by piezoelectric polarization fields. The activation energy of the defect state was calculated to be 279 meV using the temperature dependency of the recovery time.

5.
Sensors (Basel) ; 21(14)2021 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-34300410

RESUMEN

The aim of this study was to quantitatively assess the residual adhesive on orthodontic ceramic bracket-removed dental surface. In orthodontic process, ceramic bracket was repeated debonding physically, then the adhesive remained on the dental surface. The residual adhesive caused a lack of adhesive strength between dental and ceramic bracket. Since commonly used adhesive in orthodontics is translucent, residual adhesive is hard to be detected with conventional microscopes. Therefore, 1310 nm center wavelength swept-source OCT system based on laboratory customized image processing algorithm was used for the precise detection of residual adhesive on tooth surface. The algorithm separates residual adhesive from dental surface by comparing the height of adjacent B-scan images, while providing color-scaled images emphasizing the thickness information of residual adhesive. Finally, the acquired results were compared with microscopic and adhesive remnant index scoring gold standards, while the comparison confirmed the potential merits and the improvements of the proposed method over gold standards.


Asunto(s)
Adhesivos , Soportes Ortodóncicos , Algoritmos , Cerámica , Ensayo de Materiales , Propiedades de Superficie , Tomografía de Coherencia Óptica
6.
Opt Express ; 29(8): 12001-12009, 2021 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-33984969

RESUMEN

We present the flat-top supercontinuum source with high repetition rate over a broad bandwidth. The flatness and high repetition rate are achieved by iterative optical line-by-line spectrum shaping on electro-optic optical frequency combs. By applying Gaussian apodized pulse train to a highly nonlinear medium with optimized Gaussian coefficient and nonlinear polarization rotation techniques, we implemented here a flat-top supercontinuum with a 47.7 nm bandwidth at 3 dB and 30 GHz repetition rate. The generation of high repetition rate supercontinuum sources with smooth and coherent spectrum is the critical challenging task for many applications such as optical communications and the optical arbitrary waveform generation. This work leads us to new possibilities for generating hundreds or thousands of flattened coherent optical carriers with a simple configuration.

7.
Diagnostics (Basel) ; 10(12)2020 Nov 27.
Artículo en Inglés | MEDLINE | ID: mdl-33261167

RESUMEN

The radio frequency (RF) coil is one of the key components of the magnetic resonance imaging (MRI) system. It has a significant impact on the performance of the nuclear magnetic resonance (NMR) detection. Among numerous practical designs of RF coils for NMR imaging, the birdcage RF coil is the most popular choice from low field to ultra-high field MRI systems. In the transmission mode, it can establish a strong and homogeneous transverse magnetic field B1 for any element at its Larmor frequency. Similarly, in the reception mode, it exhibits extremely high sensitivity for the detection of even faint NMR signals from the volume of interest. Despite the sophisticated 3D structure of the birdcage coil, the developments in the design, analysis, and implementation technologies during the past decade have rendered the development of the birdcage coils quite reasonable. This article provides a detailed review of the recent progress in the birdcage RF coil technology for the MRI system.

8.
Int J Comput Assist Radiol Surg ; 12(5): 855-864, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28063078

RESUMEN

PURPOSE: Radiographic measurements using two-dimensional (2D) plain radiographs or planes from computed tomography (CT) scans have several drawbacks, while measurements using images of three-dimensional (3D) reconstructed bone models can provide more consistent anthropometric information. We compared the consistency of results using measurements based on images of 3D reconstructed bone models (3D measurements) with those using planes from CT scans (measurements using 2D slice images). METHODS: Ninety-six of 561 patients who had undergone deep vein thrombosis-CT between January 2013 and November 2014 were randomly selected. We evaluated measurements using 2D slice images and 3D measurements. The images used for 3D reconstruction of bone models were obtained and measured using [Formula: see text] and [Formula: see text] (Materialize, Leuven, Belgium). RESULTS: The mean acetabular inclination, acetabular anteversion and femoral anteversion values on 2D slice images were 42.01[Formula: see text], 18.64[Formula: see text] and 14.44[Formula: see text], respectively, while those using images of 3D reconstructed bone models were 52.80[Formula: see text], 14.98[Formula: see text] and 17.26[Formula: see text]. Intra-rater reliabilities for acetabular inclination, acetabular anteversion, and femoral anteversion on 2D slice images were 0.55, 0.81, and 0.85, respectively, while those for 3D measurements were 0.98, 0.99, and 0.98. Inter-rater reliabilities for acetabular inclination, acetabular anteversion and femoral anteversion on 2D slice images were 0.48, 0.86, and 0.84, respectively, while those for 3D measurements were 0.97, 0.99, and 0.97. CONCLUSION: The differences between the two measurements are explained by the use of different tools. However, more consistent measurements were possible using the images of 3D reconstructed bone models. Therefore, 3D measurement can be a good alternative to measurement using 2D slice images.


Asunto(s)
Fémur/diagnóstico por imagen , Imagenología Tridimensional/métodos , Procedimientos de Cirugía Plástica/métodos , Tomografía Computarizada por Rayos X/métodos , Acetábulo/cirugía , Anciano , Femenino , Fémur/cirugía , Humanos , Masculino , Persona de Mediana Edad , Orientación Espacial , Radiografía , Valores de Referencia , Reproducibilidad de los Resultados , Trombosis de la Vena/diagnóstico por imagen
9.
Nanoscale Res Lett ; 8(1): 30, 2013 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-23320631

RESUMEN

: The time behavior of DSN (displaced squeezed number state) for a two-dimensional electronic circuit composed of nanoscale elements is investigated using unitary transformation approach. The original Hamiltonian of the system is somewhat complicated. However, through unitary transformation, the Hamiltonian became very simple enough that we can easily treat it. By executing inverse transformation for the wave function obtained in the transformed system, we derived the exact wave function associated to the DSN in the original system. The time evolution of the DSN is described in detail, and its corresponding probability density is illustrated. We confirmed that the probability density oscillates with time like that of a classical state. There are two factors that drive the probability density to oscillate: One is the initial amplitude of complementary functions, and the other is the external power source. The oscillation associated with the initial amplitude gradually disappears with time due to the dissipation raised by resistances of the system. These analyses exactly coincide with those obtained from classical state. The characteristics of quantum fluctuations and uncertainty relations for charges and currents are also addressed.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA