Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Small Methods ; : e2301284, 2023 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-38155148

RESUMEN

High-entropy alloys (HEAs), especially in the form of compositional complex solid solutions (CCSS), have gained attention in the field of electrocatalysis. However, exploring their vast composition space concerning their electrocatalytic properties imposes significant challenges. Scanning electrochemical cell microscopy (SECCM) offers high-speed electrochemical analysis on surface areas with a lateral resolution down to tens of nm. However, high-precision piezo positioners often used for the motion of the tip limit the area of SECCM scans to the motion range of the piezo positioners which is typically a few tens of microns. To bridge this experimental gap, the study proposes a long-range SECCM system with a rapid gas-exchange environmental cell for high-throughput electrochemical characterization of 100 mm diameter HEA thin-film material libraries (ML) obtained by combinatorial co-sputtering. Due to the gas-liquid interface at the positioned SECCM droplet on the sample, high-throughput evaluation under industrial current density conditions becomes feasible. This allows the direct correlation between electrocatalytic activity and material composition with high statistical reliability. The multidimensional data obtained accelerates materials discovery, development, and optimization.

2.
Angew Chem Int Ed Engl ; 62(39): e202310069, 2023 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-37537136

RESUMEN

The vast possibilities in the elemental combinations of high-entropy alloys (HEAs) make it essential to discover activity descriptors for establishing rational electrocatalyst design principles. Despite the increasing attention on the potential of zero charge (PZC) of hydrogen evolution reaction (HER) electrocatalyst, neither the PZC of HEAs nor the impact of the PZC on the HER activity at HEAs has been described. Here, we use scanning electrochemical cell microscopy (SECCM) to determine the PZC and the HER activities of various elemental compositions of a Pt-Pd-Ru-Ir-Ag thin-film HEA materials library (HEA-ML) with high statistical reliability. Interestingly, the PZC of Pt-Pd-Ru-Ir-Ag is linearly correlated with its composition-weighted average work function. The HER current density in acidic media positively correlates with the PZC, which can be explained by the preconcentration of H+ in the electrical double layer at potentials negative of the PZC.

3.
J Chem Phys ; 158(13): 134707, 2023 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-37031154

RESUMEN

Room temperature ionic liquids (RT-ILs) are promising electrolytes for electrocatalysis. Understanding the effects of the electrode-electrolyte interface structure on electrocatalysis in RT-ILs is important. Ultrafast mass transport of redox species in N-methyl-N-ethyl-pyrrolidinium polybromide (MEPBr2n+1) enabled evaluation of the reorganization energy (λ), which reflects the solvation structure in the inner Helmholtz plane (IHP). λ was achieved by fitting the electron transfer rate-limited voltammogram at a Pt ultramicroelectrode (UME) to the Marcus-Hush-Chidsey model for heterogeneous electron transfer kinetics. However, it is time-consuming or even impossible to prepare electrode materials, including alloys of numerous compositions in the form of UME, for each experiment. Herein, we report a method to evaluate the λ of MEPBr2n+1 by scanning electrochemical cell microscopy (SECCM), which allows high throughput electrochemical measurements using a single electrode with high spatial resolution. Fast mass transport in the nanosized SECCM tip is critical for achieving heterogeneous electron transfer-limited voltammograms. Furthermore, investigating λ on a high-entropy alloy materials library composed of Pt, Pd, Ru, Ir, and Ag suggests a negative correlation between λ and the work function. Given that the potential of zero charge correlates with the work function of electrodes, this can be attributed to the surface-charge sensitive ionic structure in the IHP of MEPBr2n+1, modulating the solvation energy of the redox-active species in the IHP.

4.
Chem Sci ; 13(30): 8821-8828, 2022 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-35975145

RESUMEN

In ionic liquids (ILs), the electric double layer (EDL) is where heterogeneous electron transfer (ET) occurs. Nevertheless, the relationship between the EDL structure and its kinetics has been rarely studied, especially for ET taking place in the inner Helmholtz plane (IHP). This is largely because of the lack of an appropriate model system for experiments. In this work, we determined the reorganization energy (λ) of Br2 reduction in a redox-active IL 1-ethyl-1-methylpyrrolidinium polybromide (MEPBr2n+1) based on the Marcus-Hush-Chidsey model. Exceptionally fast mass transport of Br2 in MEPBr2n+1 allows voltammograms to be obtained in which the current plateau is regulated by electron-transfer kinetics. This enables investigation of the microscopic environment in the IHP of the IL affecting electrocatalytic reactions through reorganization energy. As a demonstration, TiO2-modified Pt was employed to show pH-dependent reorganization energy, which suggests the switch of major ions at the IHP as a function of surface charges of electrodes.

5.
Anal Chem ; 94(2): 1248-1255, 2022 01 18.
Artículo en Inglés | MEDLINE | ID: mdl-34964606

RESUMEN

It is important but challenging to elucidate the electrochemical reaction mechanisms of organic compounds using electroanalytical methods. Particularly, a rapid and straightforward method that provides information on reaction intermediates or other key electrochemical parameters may be useful. In this work, we exploited the advantages of classic thin-layer electrochemistry to develop a thin-layer electroanalysis microchip (TEAM). The TEAM provided better-resolved voltammetric peaks than under semi-infinite diffusion conditions owing to its small height. Importantly, rapid and accurate determination of the number of electrons transferred, n, was enabled by mechanically confining the microliter-scale volume analyte at the electrode, while securing ionic conduction using polyelectrolyte gels. The performance of the TEAM was validated using voltammetry and coulometry of standard redox couples. Utilizing the TEAM, a (spectro)electrochemical analysis of FM 1-43, an organic dye widely used in neuroscience, was successfully performed. Moreover, the TEAM was applied to study the electrochemical oxidation mechanism of pivanilides and alkyltrifluoroborate salts with different substituents and solvents. This work suggests that TEAM is a promising tool to provide invaluable mechanistic information and promote the rational design of electrosynthetic strategies.


Asunto(s)
Electroquímica/métodos , Análisis por Micromatrices/métodos , Difusión , Electrodos , Electrones , Oxidación-Reducción
6.
ACS Appl Mater Interfaces ; 13(23): 26748-26758, 2021 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-34078075

RESUMEN

Ion current rectification (ICR), diodelike behavior in surface-charged nanopores, shows promise in the design of delivery probes for manipulation of neural networks as it can solve diffusive leakages that might be critical in clinical and research applications. However, it has not been achieved because ICR has restrictions in nanosized dimension and low electrolyte concentration, and rectification direction is inappropriate for delivery. Herein, we present a polyelectrolyte gel-filled (PGF) micropipette harnessing inverted ICR as a delivery probe, which quantitatively transports glutamate to stimulate primary cultured neurons with high efficiency while minimizing leakages. Since the gel works as an ensemble of numerous surface-charged nanopores, the current is rectified in the micro-opening and physiological environment. By extending the charge-selective region using the gel, inverted ICR is generated, which drives outward deliveries of major charge carriers. This study will help in exploring new aspects of ICR and broaden its applications for advanced chemical delivery.


Asunto(s)
Sistemas de Liberación de Medicamentos , Conductividad Eléctrica , Electrólitos/química , Ácido Glutámico/metabolismo , Neuronas/fisiología , Animales , Transporte Iónico , Nanoporos , Neuronas/citología , Ratas , Ratas Sprague-Dawley
7.
Anal Chem ; 92(15): 10504-10511, 2020 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-32489093

RESUMEN

As a novel approach to the in situ real-time investigation of an ITO electrode during the wet etching process, step-excitation Fourier-transform electrochemical impedance spectroscopy (FT-EIS) was implemented. The equivalent circuit parameters (e.g., Rct, Cdl) continuously obtained by the FT-EIS measurements during the entire etching process showed an electrode activation at the initial period as well as the completion of etching. The FT-EIS results were further validated by cyclic voltammograms and impedance measurements of partially etched ITO films using ferri- and ferrocyanide solution in combination with FESEM imaging, EDS, XRD analyses, and COMSOL simulation. We also demonstrated that this technique can be further utilized to obtain intact interdigitated array (IDA) electrodes in a reproducible manner, which is generally considered to be quite tricky due to delicacy of the pattern. Given that the FT-EIS allows for instantaneous snapshots of the electrode at every moment, this work may hold promise for in situ real-time examination of structural, electrokinetic, or mass transfer-related information on electrochemical systems undergoing constantly changing, transient processes including etching, which would be impossible with conventional electroanalytical techniques.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA