Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 94
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Maxillofac Plast Reconstr Surg ; 46(1): 17, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38727979

RESUMEN

BACKGROUND: Immediate implant placement has gained popularity due to its several advantages. However, immediate placement has its challenges, including concerns about primary stability and bone formation around the implant. The aim of the present study is to evaluate the clinical outcomes of tapered, sand-blasted, and acid-etched internal submerged dental implants in various regions of the jaw bones and to provide a positional rationale for immediate implant placement. METHODS: Between 2009 and 2018, a single surgeon at Seoul National University Dental Hospital in Seoul, Korea, immediately inserted 49 dental implants with tapered bone-level design after extraction, in a total of 34 patients. The clinical outcomes were collected and evaluated, focusing on location of implant placement and marginal bone loss (MBL), with consideration of other parameters such as implant diameter and length. RESULTS: Of 49 immediately installed Luna® (Shinhung Co., Seoul, Korea) dental implants, 23 were placed in the mandible, and 26 were set in the maxilla. The mean age of patients at the time of installation was 65.91 years, ranging from 40 to 86 years. The average follow-up period was 7.43 years, with a range of 5 to 14 years. After a 5-year retrospective evaluation of tapered, sand-blasted, and acid-etched internal submerged dental implants for immediate implant placement, the cumulative survival rate was 93.88%, with 100% survival rate in the mandible and premolar region of both the maxilla and mandible. CONCLUSIONS: After a 5-year evaluation, tapered, sand-blasted, and acid-etched internal submerged dental implants demonstrated good efficacy for immediate placement in various locations within the dental arches, exhibiting effective clinical performance.

2.
Bioengineering (Basel) ; 11(3)2024 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-38534546

RESUMEN

Narrow-diameter implants (NDI) serve as a solution for treating limited bone volume in the anterior mandible. This study aimed to evaluate the one-year clinical outcomes of various NDIs in the mandibular incisor area after immediate loading in partially edentulous patients. This single-center, prospective, single-blinded, randomized controlled trial study included 21 patients, with 7 patients in each of the following groups: control (BLT NC SLActive®; Straumann), experimental group 1 (CMI IS-III Active® S-Narrow; Neobiotech), and experimental group 2 (CMI IS-III Active® Narrow; Neobiotech). Using full digital flow, two fixtures were placed in each patient and immediately provisionalized on the day of surgery. Evaluations encompassed periapical radiographs, implant stability quotient (ISQ), implant stability test (IST) readings, per-implant soft tissue health, patient satisfaction surveys, and esthetic score assessments. Definitive prostheses were delivered twelve weeks post-surgery (CRiS, number: KCT0007300). Following exclusions due to low stability values (n = 2), fixture failure (n = 5), and voluntary withdrawal (n = 1), the implant success rate for patients completing all clinical protocols stood at 100%. The resulting patient failure rates in the control, experimental group 1, and experimental group 2 were 50.0%, 42.9%, and 14.3%, respectively. There were no significant differences between the groups in terms of marginal bone loss, soft tissue health, patient satisfaction, and esthetic scores. Narrow implants showed superior clinical outcomes, followed by S-Narrow and Straumann implants. Calculated one-year survival rates at the implant level were 66.7% for the control group, 85.7% for experimental group 1, and 100% for experimental group 2. All three types of NDIs showed acceptable clinical and radiographic results during the year-long observation period.

3.
Maxillofac Plast Reconstr Surg ; 45(1): 35, 2023 Oct 06.
Artículo en Inglés | MEDLINE | ID: mdl-37801094

RESUMEN

BACKGROUND: The 10-year survival rate of dental implants in healthy subjects is 90-95%. While in healthy individuals, dental implants have become commonplace to solve problems of edentulism, whether dental implant treatment is optimal in patients with systemic disease remains unclear. The purpose of this study is to investigate the clinical outcomes of tapered, sand-blasted, and acid-etched internal submerged dental implants installed in medically compromised patients in our maxillofacial surgical unit. METHODS: A total of 1019 Luna® dental implants were placed in 333 patients at the Department of Oral and Maxillofacial Surgery, Seoul National University Dental Hospital. Kaplan-Meier survival estimates after 10 years of follow-up were computed for healthy vs. medically compromised patients. RESULTS: The 10-year follow-up survival rate of 1019 Luna® dental implants in the Korean maxillofacial surgical unit was 97.0% with a mean follow-up of 41.13 ± 35.13 months (0-120 months). The survival rate was 97.0%, in which 31 implants were failed during the follow-up. Cumulative 10-year implant survival rates were 99.4% in healthy individuals without systemic disease and 95.9% in patients with systemic disease. CONCLUSIONS: Comparable success and survival rates were achieved with those of implants in healthy patients. Preoperative general health assessments including laboratory test results and checking the previous medication records are essential in diagnosing any unrecognized conditions for improved implant success rates in medically compromised patients.

4.
J Craniofac Surg ; 34(5): e517-e520, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37253249

RESUMEN

Aggressive aspergillosis is a life-threatening fungal infection with rapid progress, mainly affecting the maxillofacial area, especially the nose and paranasal sinuses, in patients with immunocompromised conditions such as diabetes mellitus. Aggressive aspergillosis infection should be differentiated from other invasive fungal sinusitis for early recognition with correct prompt treatment. The main treatment is aggressive surgical debridement such as maxillectomy. Although aggressive debridement should be performed, preservation of the palatal flap should be considered for better postoperative outcomes. In this manuscript, we report the case of a diabetic patient with aggressive aspergillosis affecting the maxilla and paranasal sinuses and describe the appropriate surgical management and prosthodontic rehabilitation.


Asunto(s)
Aspergilosis , Diabetes Mellitus , Micosis , Senos Paranasales , Sinusitis , Humanos , Aspergilosis/complicaciones , Aspergilosis/cirugía , Senos Paranasales/cirugía , Sinusitis/microbiología
5.
BMC Oral Health ; 23(1): 33, 2023 01 20.
Artículo en Inglés | MEDLINE | ID: mdl-36670429

RESUMEN

BACKGROUND: Orthodontic brackets provide a favorable environment for Streptococcus mutans biofilm formation, increasing the risk of white spots and dental caries. Manganese oxide (MnO2) nanozyme-doped diatom microbubbler (DM) is a recently developed material for biofilm removal. DM can generate oxygen by catalase-mimicking activity in Hydrogen peroxide (H2O2) solution and move with ejecting oxygen microbubbles to produce a mechanical self-cleansing effect. This study aimed to evaluate the feasibility of DM as a novel bracket cleaner. METHODS: DM was prepared according to the protocol and analyzed using a scanning electron microscope (SEM). We treated S. mutans biofilms grown over bracket with phosphate-buffered saline (PBS group), 0.12% chlorhexidine (CHX group), 3% H2O2 (H2O2 group), and co-treatment with 3 mg/mL of DM and 3% H2O2 (DM group). The biofilm removal effect was analyzed using crystal violet assay, and the results were observed using SEM. The viability of S. mutans in remaining biofilms was evaluated using confocal laser scanning microscopy (CLSM). Finally, we examined the effect of all materials on mature multispecies biofilms formed on debonded brackets. RESULTS: Crystal violet assay results revealed that the CHX group removed more biofilms than the control group, and the DM group removed biofilms more effectively than the CHX group (p < 0.0001). SEM and CLSM images showed that CHX killed S. mutans but failed to remove most biofilms on brackets. However, DM effectively removed biofilms and mature multispecies biofilms on debonded brackets (p < 0.0001). CONCLUSIONS: Co-treatment with DM and H2O2 is effective in removing biofilms on orthodontic brackets compared to conventional antibacterial agents.


Asunto(s)
Caries Dental , Diatomeas , Soportes Ortodóncicos , Humanos , Peróxido de Hidrógeno/farmacología , Compuestos de Manganeso/farmacología , Óxidos/farmacología , Caries Dental/microbiología , Violeta de Genciana/farmacología , Streptococcus mutans , Biopelículas , Antibacterianos/farmacología
6.
J Prosthet Dent ; 130(3): 273-277, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35184883

RESUMEN

Acrylic resin denture teeth can wear and chip when opposed by zirconia prostheses. This clinical report describes the use of zirconia complete crowns to prevent these problems. The predictability of treatment was improved by using the computer-aided design and computer-aided manufacturing (CAD-CAM) double-scanning method.


Asunto(s)
Resinas Acrílicas , Coronas , Circonio , Diseño Asistido por Computadora , Dentaduras
7.
Cells ; 11(18)2022 09 16.
Artículo en Inglés | MEDLINE | ID: mdl-36139471

RESUMEN

Aging is a complex feature and involves loss of multiple functions and nonreversible phenotypes. However, several studies suggest it is possible to protect against aging and promote rejuvenation. Aging is associated with many factors, such as telomere shortening, DNA damage, mitochondrial dysfunction, and loss of homeostasis. The integrity of the cytoskeleton is associated with several cellular functions, such as migration, proliferation, degeneration, and mitochondrial bioenergy production, and chronic disorders, including neuronal degeneration and premature aging. Cytoskeletal integrity is closely related with several functional activities of cells, such as aging, proliferation, degeneration, and mitochondrial bioenergy production. Therefore, regulation of cytoskeletal integrity may be useful to elicit antiaging effects and to treat degenerative diseases, such as dementia. The actin cytoskeleton is dynamic because its assembly and disassembly change depending on the cellular status. Aged cells exhibit loss of cytoskeletal stability and decline in functional activities linked to longevity. Several studies reported that improvement of cytoskeletal stability can recover functional activities. In particular, microtubule stabilizers can be used to treat dementia. Furthermore, studies of the quality of aged oocytes and embryos revealed a relationship between cytoskeletal integrity and mitochondrial activity. This review summarizes the links of cytoskeletal properties with aging and degenerative diseases and how cytoskeletal integrity can be modulated to elicit antiaging and therapeutic effects.


Asunto(s)
Citoesqueleto , Demencia , Senescencia Celular/fisiología , Citoesqueleto/fisiología , Humanos , Acortamiento del Telómero
8.
J Prosthet Dent ; 2022 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-35691713

RESUMEN

STATEMENT OF PROBLEM: When scanning implant abutments, an incomplete scan is often obtained because of a subgingival location or restricted accessibility. Whether these problems can be overcome with a novel scanning technique with digital superimposition of the custom abutment is unclear. PURPOSE: The purpose of this in vitro study was to evaluate the effect of the process of superimposing the custom abutment library data onto the scanned abutment data on the accuracy of the digital scan with an intraoral scanner. MATERIAL AND METHODS: A model with a single implant was prepared. The custom abutment of the corresponding implant was produced and was scanned with a laboratory scanner to produce the custom abutment library data. The custom abutment was connected to the implant, and the model was scanned with a laboratory scanner for the reference data. The custom abutment and adjacent teeth were scanned 10 times with an intraoral scanner. Thus, 10 files were saved as the first test group (IOS). After transferring 10 files of the group IOS to a computer-aided design (CAD) software program (exocad DentalCAD), the custom abutment library data were superimposed on the corresponding abutments, and the results were saved as the second test group (S-Exo). For the third test group (S-Den), the same superimposing process was performed as for the group S-Exo but by using another CAD software program (Dental System). The accuracy of the files of the 3 test groups was evaluated by comparing them with the reference file by using a 3D inspection software program. Statistical analysis was performed with 1-way repeated measures ANOVA (α=.05). RESULTS: The RMS of the IOS group decreased significantly from 42.1 ±1.1 µm to 36.37 ±0.74 µm for the S-Exo group and 36.89 ±0.69 µm for the S-Den group after superimposition (P<.05). InTOL increased significantly from 88.17 ±0.75% to 91.57 ±0.56% in the S-Exo group and 91.31 ±0.56% in the S-Den group (P<.05). For the mean 3D discrepancy of all 66 points along the margin and 16 points of interest, the IOS group showed significantly higher discrepancy than the superimposed groups (P<.05), implying that the accuracy of scanned data with the intraoral scanner increased after superimposition with the abutment library data. No significant difference was found according to the type of software program (P>.05). CONCLUSIONS: The process of superimposing the titanium custom abutment with the prescanned custom abutment library data improved the accuracy of a digital scan made with an intraoral scanner.

9.
PLoS One ; 17(5): e0267742, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35511774

RESUMEN

The advent of intraoral scanning methods has caused a paradigm shift in dentistry. However, despite their many advantages, intraoral scanners cannot accurately recognize the metallic surfaces of prothesis. Therefore, this experiment was designed to verify the effect of scanning-aid agents on the scanning accuracy using metallic reference models. Three different types of metallic reference models (inlay, onlay, and bridge) were specially designed and produced using a milling machine to simulate intraoral dental restorations. Three experimental groups (application of ScanCure, IP Scan Spray, and VITA Powder Scan Spray) were set up and scanned images (each n = 5) were acquired using the I500® intraoral scanner. The reference datasets were established by a 3D design that reflected the deviations between the measured distances and previously planned distances on the reference models. All acquired experimental datasets were digitally superimposed and compared with the reference datasets. Intragroup comparisons (precision, n = 10) were also performed. The root mean square (RMS) values of trueness in the ScanCure and IP groups were significantly more accurate than those of the VITA group in the inlay and onlay reference models (p < 0.05). Notably, in the bridge reference model, the liquid-type ScanCure group showed the highest accuracy of trueness, with statistical significance (p < 0.05). However, the RMS values of precision were not significantly different among the groups. These findings suggest that liquid-type scanning agents can be effectively used to obtain more accurate scan images of intraoral metallic dental restorations.


Asunto(s)
Diseño Asistido por Computadora , Modelos Dentales , Técnica de Impresión Dental , Imagenología Tridimensional , Cintigrafía
10.
ACS Appl Mater Interfaces ; 14(24): 27634-27650, 2022 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-35638645

RESUMEN

Peri-implantitis is a major cause of dental implant failure. Bacterial biofilm contamination on the implant induces surrounding bone resorption and soft tissue inflammation, leading to severe deterioration of oral health. However, conventional biofilm removal procedures, such as mechanical decontamination and antiseptic application, are not effective enough to induce reosseointegration on decontaminated implant surfaces. This is due to (1) incomplete decontamination of the biofilm from inaccessible areas and (2) physicochemical alteration of implant surfaces caused by decontamination procedures. Herein, a safe and effective therapeutic approach for peri-implantitis is developed, which involves decontamination of implant-bound biofilms using the kinetic energy of microsized oxygen bubbles generated from the catalytic reaction between hydrogen peroxide (H2O2) and manganese oxide (MnO2) nanozyme sheet-doped silica diatom microparticles (Diatom Microbubbler, DM). Rapidly moving microsized DM particles are able to penetrate narrow spaces between implant screws, exerting just the right amount of force to entirely destroy biofilms without harming the surrounding mucosa or implant surfaces, as opposed to conventional antiseptics such as chlorhexidine or 3% H2O2 when used alone. Consequently, decontamination with DM facilitates successful reosseointegration on the peri-implantitis-affected implant surface. In summary, our new DM-based therapeutic approach will become a promising alternative to resolve clinically challenging aspects of peri-implantitis.


Asunto(s)
Antiinfecciosos Locales , Implantes Dentales , Diatomeas , Periimplantitis , Humanos , Peróxido de Hidrógeno , Compuestos de Manganeso/uso terapéutico , Óxidos/farmacología , Óxidos/uso terapéutico , Periimplantitis/tratamiento farmacológico , Periimplantitis/microbiología
11.
J Prosthet Dent ; 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-35246320

RESUMEN

STATEMENT OF PROBLEM: Duplicating mandibular movement with a semi-adjustable articulator has been reported to lack accuracy. However, although previous studies have analyzed articulator movement, few have compared excursive tooth contact on the articulator with tooth contact during actual mandibular movement. PURPOSE: The purpose of this clinical study was to evaluate the concordance of semi-adjustable articulator contacts with intraoral contacts during eccentric movements by using a T-scan occlusal analysis system. MATERIAL AND METHODS: Forty-two participants with normal occlusion and without signs of temporomandibular disorder were analyzed for the reproducibility of eccentric tooth contact on a semi-adjustable articulator. Maxillary casts made from irreversible hydrocolloid impressions were mounted on a semi-adjustable articulator with the facebow. The condylar inclination of the articulator was set by using interocclusal records. Three recordings of right and left excursive mandibular movement and protrusive mandibular movement were made in the supine position by using the T-scan v9.1. The same procedure was then performed with the articulator. The results of complete mandibular movement from T-scan measurements were divided into 4 time points for analysis: T0, T1, T2, and T3. The concordance of intraoral and articulator occlusal contacts was evaluated at each point, and the occlusal force for each tooth was compared. Overall concordance and concordance of the working and nonworking sides were also calculated. Repeated measures analysis of variance was used to analyze differences between the concordance of intraoral and articulator contacts according to mandibular movement direction, time, and working and nonworking sides (α=.01). RESULTS: For all teeth, concordance between the intraoral and articulator occlusal contacts during excursive mandibular movement was greatest at T0, decreasing at T1 and T2, and increasing at T3. No significant differences were found in the concordance among the right lateral, left lateral, and protrusive excursion (P>.01). The concordance of working side occlusal contacts during lateral excursion was significantly lower at T3 than that at T0 (P<.01). CONCLUSIONS: When comparing intraoral and articulator contacts during lateral eccentric mandibular movement, concordance was affected by time and working or nonworking side. Reproducibility of initial eccentric tooth contact on a semi-adjustable articulator appeared to be reliable. However, occlusal adjustment of the working side might be required after prosthesis delivery.

12.
J Prosthet Dent ; 127(5): 784.e1-784.e7, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35221037

RESUMEN

STATEMENT OF PROBLEM: Although 3-dimensional (3D)-printed resin prostheses are widely used, studies on the effects of the manufacturing parameters of 3D printing on the color stability and stainability of these prostheses are lacking. PURPOSE: The purpose of this in vitro study was to investigate the effects of layer thickness and printing orientation on the color stability and stainability of a 3D-printed resin. In addition, the influence of roughness and water contact angle was evaluated. MATERIAL AND METHODS: Color changes (ΔE00) in tooth-colored resin specimens produced by 3D printing with 2 different layer thicknesses and 3 different printing orientations and immersed in 3 types of aging media (distilled water, coffee solution, and wine) were evaluated (n=10). The CIELab color values were measured with a spectrophotometer at baseline and different time points (1, 3, 7, 15, and 30 days). The surface roughness (Ra) of resin specimens was measured at various time points (baseline, 7, 15, and 30 days) by confocal laser scanning microscopy after immersion in coffee solution (n=15). The water contact angle was determined by using the sessile drop method (n=10). The ΔE00 values were analyzed by using the 3-way repeated measures ANOVA followed by the Bonferroni test and Dunnett T3 test (α=.05). Ra values were analyzed by 3-way repeated measures ANOVA (α=.05). The water contact angle data were analyzed by 2-way ANOVA (α=.05). RESULTS: The 3-way repeated measures ANOVA showed that layer thickness, printing orientation, and storage time significantly influenced the ΔE00 values of the 3D-printed resin specimens in each aging medium (P<.001). The ΔE00 values in the 0-degree subgroups were significantly lower than those in the 45- and 90-degree subgroups (P<.05). The ΔE00 values in the 25-µm thick groups were significantly higher than those in the 100-µm thick groups (P<.05). The ΔE00 values demonstrated an increase up to 15 days in all aging media. In distilled water, the ΔE00 values of the specimens increased or decreased depending on the groups, whereas in the coffee solution, the values decreased after 15 days (P<.001); in red wine, the values demonstrated a continuous increase up to 30 days in all groups (P<.001). The 3-way repeated measures ANOVA showed that the Ra values did not change significantly with immersion time (P=.444). The 2-way ANOVA showed that the water contact angle was not significantly affected by layer thickness (P=.921) or printing orientation (P=.062). CONCLUSIONS: Layer thickness and printing orientation affected the color stability and stainability of the 3D-printed resin. The discoloration of the 3D-printed resin differed with time, depending on the type of aging media used.


Asunto(s)
Café , Resinas Compuestas , Color , Ensayo de Materiales , Impresión Tridimensional , Propiedades de Superficie , Agua
13.
J Prosthet Dent ; 127(2): 331-337, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33250197

RESUMEN

STATEMENT OF PROBLEM: A digital quantitative occlusal analyzer with claimed lower cost and easier maneuverability has been introduced to replace conventional methods. However, information regarding its performance is scarce. PURPOSE: The purpose of this in vitro study was to evaluate the reliability and repeatability of a newly introduced digital occlusal analysis device (Accura) and to compare it with an established occlusal analyzer (T-scan Novus). MATERIAL AND METHODS: The sensor films of both devices were positioned between titanium maxillary and mandibular models that were equilibrated and arbitrarily mounted on a semiadjustable articulator. Compressive force was applied to the upper arm of the articulator with a universal testing machine, increased gradually to 50 N, and then released automatically. The time and force measurements from the universal testing machine and the tested devices were recorded by operating software programs. Five articulating film sensors of each device were tested 3 times each by 2 examiners and were repeated on consecutive days, totaling 60 trials per device. Reliability was defined as an agreement between the loaded force and measured force. Repeatability was defined as an agreement between repeated measurements of the Accura and T-scan Novus. Intraclass correlation coefficient was calculated for the statistical analysis (α=.05). RESULTS: The calculated intraclass correlation coefficient of the Accura and the universal testing machine was 0.952. The intraclass correlation coefficient of the T-scan Novus and the universal testing machine was 0.963. Intraclass correlation coefficients that were calculated to compare the data acquired from different days were 0.938 for the Accura and 0.911 for the T-scan Novus. CONCLUSIONS: The experimental results indicated that the reliability of both the Accura and T-scan Novus was excellent for measuring occlusal forces. In addition, both the Accura and T-scan Novus exhibited excellent repeatability.


Asunto(s)
Fuerza de la Mordida , Articuladores Dentales , Maxilar , Reproducibilidad de los Resultados , Programas Informáticos
14.
J Mech Behav Biomed Mater ; 126: 104993, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34871954

RESUMEN

This study investigated the effect of post-curing time on the color stability and related properties, such as degree of conversion (DC), surface roughness, water contact angle, water sorption (Wsp), and water solubility (Wsl) of 3D-printed resin for dental restorations. The 3D-printed specimens were divided into four groups according to the post-curing time (0, 5, 10, and 20 min). Color changes (ΔE00) of the specimens immersed in aging media were measured using a spectrophotometer at different aging times. The DC of the resin was measured using a FTIR. The surface roughness (Ra) of the resin immersed in coffee was measured at different aging times. Water contact angle was evaluated using the sessile drop method, and Wsp and Wsl were tested according to the ISO 4049:2019. The ΔE00 values of the specimens immersed in coffee and red wine decreased with increasing post-curing time. As the post-curing time increased up to 10 min, the DC increased and water contact angle decreased. The Ra value of the group without post-curing (0 min) increased gradually for 30 days, except between 7 and 15 days. However, when the post-curing time increased to greater than 10 min, no apparent change in Ra value was detected. The Wsp and Wsl of the group without post-curing were significantly lower and larger than that of the other groups, respectively. The longer the post-curing time of the tooth-colored 3D-printed resin, the better the color stability. The post-curing time of the 3D-printed resin affected the DC, surface roughness after aging in the staining media, water contact angle, water sorption, and water solubility.


Asunto(s)
Café , Impresión Tridimensional , Color , Resinas Compuestas , Ensayo de Materiales , Solubilidad , Propiedades de Superficie
15.
Heliyon ; 8(12): e12290, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36593839

RESUMEN

To prevent oral candidiasis, removal of the Candida biofilms from dentures is important. However, common denture cleaners are insufficiently effective in removing biofilms. A manganese oxide (MnO2) nanozyme-doped diatom microbubbler (DM) can generate oxygen gas microbubbles by a catalase-mimicking activity in hydrogen peroxide (H2O2). DM can invade and destroy biofilms with the driving force of continuously generated microbubbles. In this study, the Candida biofilm removal efficiency by co-treatment of DM and H2O2 was investigated. Diatom particles were reacted with (3-aminopropyl)triethoxysilane to prepare amine-substituted diatom particles. These particles were reacted with potassium permanganate to fabricate DMs. The morphology and components of DM were analyzed by using a scanning electron microscope (SEM). Four types of denture base resin specimens on which biofilms of Candida albicans were formed were treated with phosphate-buffered saline (PBS group), Polident 5-Minute (Polident group), 0.12% chlorhexidine gluconate (CHX group), 3% H2O2 (H2O2 group), and co-treatment of 3 mg/mL of DM and 3% H2O2 (DM group). The biofilm removal effect of each group was quantitatively analyzed by crystal violet assay, and the results were visually confirmed by SEM images. After each treatment, the remaining C. albicans were stained with Hoechst 33342/propidium iodide, and observed with confocal laser scanning microscopy (CLSM) to evaluate the viability. MnO2 nanozyme sheets were successfully doped on the surface of the fabricated DM. Although biofilms were not effectively removed in the Polident and CHX groups, CLSM images showed that CHX was able to effectively kill C. albicans in the biofilms on all resin specimen types. According to the crystal violet analysis, the H2O2 groups removed the biofilms on heat-activated and 3D-printed resins (P < .01), but could not remove the biofilms on autopolymerizing and milled resins significantly (P = .1161 and P = .1401, respectively). The DM groups significantly removed C. albicans from all resin specimen types (P < .01).

16.
Cells ; 10(9)2021 09 11.
Artículo en Inglés | MEDLINE | ID: mdl-34572039

RESUMEN

The maturation of the oocyte is influenced by cumulus cells (CCs) and associated with pregnancy rate, whereas the influencing factors have not been completely elucidated in the CCs. In this study, we identified new regulators of CCs for high-quality oocytes and successful pregnancies during assisted reproductive techniques. CCs were collected from cumulus-oocyte complexes (COCs) in young (≤33 years old) and old (≥40 years old) women undergoing intracytoplasmic sperm injection (ICSI) procedures. We screened for factors differentially expressed between young vs. old CCs and pregnancy vs. non-pregnancy using whole mRNA-seq-next-generation sequencing (NGS). We characterized the transcriptome of the CCs to identify factors critical for achieving pregnancy in IVF cycles. Women in the young and old pregnancy groups exhibited the up- and downregulation of multiple genes compared with the non-pregnancy groups, revealing the differential regulation of several specific genes involved in ovarian steroidogenesis in CCs. It was shown that the low-density lipoprotein (LDL) receptor to the steroidogenesis pathway was upregulated in CCs with higher maturity rates of oocytes in the pregnancy group. In conclusion, a higher pregnancy rate is related to the signaling pathway of steroidogenesis by the LDL receptor in infertile women undergoing IVF procedures.


Asunto(s)
Células del Cúmulo/citología , Infertilidad Femenina/terapia , Oocitos/citología , Folículo Ovárico/citología , Receptores de LDL/metabolismo , Esteroides/biosíntesis , Adulto , Células del Cúmulo/metabolismo , Femenino , Humanos , Infertilidad Femenina/patología , Oocitos/metabolismo , Folículo Ovárico/metabolismo , Embarazo , Transcriptoma
17.
Int J Mol Sci ; 22(10)2021 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-34064719

RESUMEN

Inflammation is a major cause of several chronic diseases and is reported to be recovered by the immuno-modulation of mesenchymal stem cells (MSCs). While most studies have focussed on the anti-inflammatory roles of MSCs in stem cell therapy, the impaired features of MSCs, such as the loss of homeostasis by systemic aging or pathologic conditions, remain incompletely understood. In this study, we investigated whether the altered phenotypes of human placenta-derived MSCs (hPD-MSCs) exposed to inflammatory cytokines, including TNF-α and IFN-γ, could be protected by MIT-001, a small anti-inflammatory and anti-necrotic molecule. MIT-001 promoted the spindle-like shape and cytoskeletal organization extending across the long cell axis, whereas hPD-MSCs exposed to TNF-α/IFN-γ exhibited increased morphological heterogeneity with an abnormal cell shape and cytoskeletal disorganization. Importantly, MIT-001 improved mitochondrial distribution across the cytoplasm. MIT-001 significantly reduced basal respiration, ATP production, and cellular ROS levels and augmented the spare respiratory capacity compared to TNF-α/IFN-γ-exposed hPD-MSCs, indicating enhanced mitochondrial quiescence and homeostasis. In conclusion, while TNF-α/IFN-γ-exposed MSCs lost homeostasis and mitochondrial quiescence by becoming over-activated in response to inflammatory cytokines, MIT-001 was able to rescue mitochondrial features and cellular phenotypes. Therefore, MIT-001 has therapeutic potential for clinical applications to treat mitochondrion-related inflammatory diseases.


Asunto(s)
Citoesqueleto/fisiología , Células Madre Mesenquimatosas/fisiología , Mitocondrias/fisiología , Compuestos Orgánicos/farmacología , Placenta/citología , Citoesqueleto/efectos de los fármacos , Femenino , Humanos , Células Madre Mesenquimatosas/citología , Células Madre Mesenquimatosas/efectos de los fármacos , Mitocondrias/efectos de los fármacos , Consumo de Oxígeno , Placenta/efectos de los fármacos , Placenta/metabolismo , Embarazo , Especies Reactivas de Oxígeno/metabolismo
18.
Materials (Basel) ; 14(9)2021 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-33946471

RESUMEN

This study was performed to verify the influence of scanning-aid materials on the accuracy and time efficiency of full-arch scanning with intraoral scanners. The full-arch reference model was constructed by a 3D printer and scanned with a model scanner to obtain the reference dataset. Four experimental groups (application of ScanCure (SC-80, ODS Co, Incheon, Korea), IP Scan Spray (IP-Division, Haimhausen, Germany) and Vita Powder Scan Spray (Vita Zahnfabrik, Stuttgart, Germany), and no treatment) were designed, and the scans were executed (trueness, n = 5) using two intraoral scanners: I500 (Medit Co., Seoul, Korea) and TRIOS (3shape, Copenhagen, Denmark). All acquired scan data were compared with the reference datasets using the 3D superimposition method and 2D linear measurements. In the 3D analysis, intragroup data were compared with each other (precision, n = 10). Time efficiency was also verified by comparing the scan times of the four experimental groups. In the 3D analysis, the root mean square (RMS) value of the precision of the scanned image was statistically significantly more accurate in the scanning-aid agent-treated groups than in the no-treatment group (p < 0.05). However, the RMS values of trueness and the types of scanning-aid materials were not significantly different. In the 2D measurements, the increased scan distance generated a greater distance deviation. The working time was significantly shorter in the scanning-aid agent groups than in the no-treatment group, with statistical significance (p < 0.05). Therefore, in clinical situations, the application of scanning-aid materials is recommended to reduce scanning time and more efficiently obtain the full-arch scanned image.

19.
Int J Womens Health ; 13: 379-384, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33883950

RESUMEN

PURPOSE: To assess the impact of additional embryo transfer (ET) on pregnancy in young women, we used a natural-experiment approach. PATIENTS AND METHODS: The design was based on the national policy of South Korea limiting the number of embryos transferred in vitro fertilization (IVF):≦2 embryos on day 2-4 or one on day 5-6 for patients aged <35, with one extra embryo allowed for patients aged ≥35. Using the data from 1909 ET cycles of 1287 women aged ≥34 and ≤35, we calculated adjusted risk ratios (RRs) for pregnancy. RESULTS: Half of cycles were undertaken by women aged 35, and additional ET was performed in 68.7% of them. Intrauterine pregnancy (45.2% vs 51.3%) and multiple gestation (30.5% vs 6.9%) were more common in women aged 35 than in those aged 34. The RR for intrauterine pregnancy was 1.34 (95% confidence interval: 1.12-1.59) when comparing double ET to single ET in frozen day 5-6 cycles. CONCLUSION: We observed no evidence of a higher probability of pregnancy with additional ET in fresh or frozen day 3-4 ET, or in fresh day 5-6 ET of women aged 35. Additional ET may not increase the successful pregnancy rate in the 35-year-old group, unless it is a frozen day 5-6 ET cycle.

20.
Biomedicines ; 9(3)2021 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-33801938

RESUMEN

There is currently no cure for infertility in women with a poor ovarian response (POR). Neogenin is reported to be abundantly expressed in the ovary; however, its role in mammalian follicular development is unclear and its ligand and signaling pathway remain uncertain. We systematically investigated the role of neogenin and the ligand repulsive guidance molecule c (RGMc) during follicular development. We treated hyperstimulated mouse ovaries with RGMc and analyzed follicular development. Furthermore, we investigated clusters of up/downregulated genes in RGMc-treated ovaries using whole-transcriptome next-generation sequencing (NGS). In addition, we investigated whether expression of up/downregulated factors identified by NGS was also altered in cumulus cells (CCs) of patients with a POR. The number of oocytes was 40% higher in RGMc-treated ovaries than in control ovaries. NGS data indicated that prostaglandin D2 (PGD2) was involved in the RGMc signaling pathway during follicular development. RGMc treatment significantly elevated the PGD2 level in culture medium of CCs obtained from patients with a POR. Our results demonstrate that RGMc as neogenin ligand promotes follicular development in ovaries via the PGD2 signaling pathway. Therefore, it may be possible to use RGMc for ovarian stimulation in patients with a POR.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA