Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
2.
J Neurophysiol ; 126(5): 1547-1554, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-34550030

RESUMEN

Exposure to 120 dB sound pressure level (SPL) band-limited noise results in delayed onset latency and reduced vestibular short-latency evoked potential (VsEP) responses. These changes are still present 4 wk after noise overstimulation. Noise-induced hearing loss (NIHL) has been shown to vary in extent and duration based on the noise intensity. This study investigated whether noise-induced peripheral vestibular hypofunction (NPVH) would also decrease in extent and/or duration with less intense noise exposure. In the present study, rats were exposed to a less intense noise (110 dB SPL) but for the same duration (6 h) and frequency range (500-4,000 Hz) as used in previous studies. The VsEP was assessed 1, 3, 7, 14, 21, and 28 days after noise exposure. In contrast to 120 dB SPL noise exposure, the 110 dB SPL noise exposures produced smaller deficits in VsEP responses that fully recovered in 62% (13/21) of animals within 1 wk. These findings suggest that NPVH, a loss or attenuation of VsEP responses with a requirement for elevated stimulus intensity to elicit measurable responses, is similar to NIHL, that is, lower sound levels produce a smaller or transient deficit. These results show that it will be important to determine the extent and duration of vestibular hypofunction for different noise exposure conditions and their impact on balance.NEW & NOTEWORTHY This is the first study to show a temporary noise-induced peripheral vestibular hypofunction that recovers following exposure to continuous noise.


Asunto(s)
Potenciales Evocados Auditivos del Tronco Encefálico/fisiología , Ruido/efectos adversos , Enfermedades Vestibulares/etiología , Enfermedades Vestibulares/fisiopatología , Potenciales Vestibulares Miogénicos Evocados/fisiología , Nervio Vestibular/fisiopatología , Enfermedades del Nervio Vestibulococlear/etiología , Enfermedades del Nervio Vestibulococlear/fisiopatología , Estimulación Acústica , Animales , Modelos Animales de Enfermedad , Pérdida Auditiva Provocada por Ruido , Masculino , Ratas , Ratas Sprague-Dawley
3.
Ear Hear ; 37(3): e188-93, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26745280

RESUMEN

OBJECTIVES: To evaluate whether monothermal caloric screening can reduce the number of caloric irrigations required in the vestibular testing battery while maintaining diagnostic accuracy. DESIGN: Prospective controlled cohort study. Three hundred and ninety patients referred for vestibular testing at this tertiary referral health system over a 1-year period were evaluated; 24 patients met exclusion or failure criteria and 366 patients were included in the study. Population was 35.6% male; average age was 50.4 years old. Each patient underwent caloric testing using either warm or cool water irrigation initially and this data was used for monothermal screening data. All patients then completed bithermal binaural caloric testing to obtain the "gold standard" bithermal data for comparison. The sensitivity and specificity of monothermal cool or monothermal warm caloric tests were calculated using a receiver operating characteristic curve analysis. RESULTS: Using a monothermal interear difference threshold of 25%, warm monothermal screening had sensitivity of 98.0%, specificity of 91.3%, false negative rate of 2%, and false positive rate of 8.7%. Cool monothermal screening also had excellent sensitivity (92.3%) and specificity (95.3)%, with a false negative rate of 7.7%, and a false positive rate of 4.7%. The diagnosis associated with the single false negative warm monothermal caloric test was compensated vestibular paresis. In the study population, 71.9% had a negative monothermal screen; if the monothermal data were accepted, 2 fewer irrigations would have been performed resulting in an average saving of $264 (typical Medicare reimbursement for 2 irrigations) billed per patient screened as well as shortening the average testing battery by about 15 min. CONCLUSIONS: Warm monothermal caloric screening can reduce time and cost of vestibular testing while nearly matching the diagnostic accuracy of bithermal testing.


Asunto(s)
Pruebas Calóricas/métodos , Enfermedades Vestibulares/diagnóstico , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Femenino , Humanos , Masculino , Tamizaje Masivo , Persona de Mediana Edad , Estudios Prospectivos , Curva ROC , Sensibilidad y Especificidad , Centros de Atención Terciaria , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...