Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Int J Mol Sci ; 23(3)2022 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-35163840

RESUMEN

Pathogenic TMPRSS6 variants impairing matriptase-2 function result in inappropriately high hepcidin levels relative to body iron status, leading to iron refractory iron deficiency anemia (IRIDA). As diagnosing IRIDA can be challenging due to its genotypical and phenotypical heterogeneity, we assessed the transferrin saturation (TSAT)/hepcidin ratio to distinguish IRIDA from multi-causal iron deficiency anemia (IDA). We included 20 IRIDA patients from a registry for rare inherited iron disorders and then enrolled 39 controls with IDA due to other causes. Plasma hepcidin-25 levels were measured by standardized isotope dilution mass spectrometry. IDA controls had not received iron therapy in the last 3 months and C-reactive protein levels were <10.0 mg/L. IRIDA patients had significantly lower TSAT/hepcidin ratios compared to IDA controls, median 0.6%/nM (interquartile range, IQR, 0.4-1.1%/nM) and 16.7%/nM (IQR, 12.0-24.0%/nM), respectively. The area under the curve for the TSAT/hepcidin ratio was 1.000 with 100% sensitivity and specificity (95% confidence intervals 84-100% and 91-100%, respectively) at an optimal cut-off point of 5.6%/nM. The TSAT/hepcidin ratio shows excellent performance in discriminating IRIDA from TMPRSS6-unrelated IDA early in the diagnostic work-up of IDA provided that recent iron therapy and moderate-to-severe inflammation are absent. These observations warrant further exploration in a broader IDA population.


Asunto(s)
Anemia Ferropénica/sangre , Hepcidinas/sangre , Proteínas de la Membrana/genética , Serina Endopeptidasas/genética , Transferrina/metabolismo , Adolescente , Anemia Ferropénica/diagnóstico , Anemia Ferropénica/genética , Área Bajo la Curva , Proteína C-Reactiva/metabolismo , Niño , Humanos , Masculino , Sensibilidad y Especificidad , Adulto Joven
2.
Clin Chem Lab Med ; 59(2): 315-323, 2020 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-33001847

RESUMEN

Objectives: Hepcidin measurement advances insights in pathophysiology, diagnosis, and treatment of iron disorders, but requires analytically sound and standardized measurement procedures (MPs). Recent development of a two-level secondary reference material (sRM) for hepcidin assays allows worldwide standardization. However, no proficiency testing (PT) schemes to ensure external quality assurance (EQA) exist and the absence of a high calibrator in the sRM set precludes optimal standardization. Methods: We developed a pilot PT together with the Dutch EQA organization Stichting Kwaliteitsbewaking Medische Laboratoriumdiagnostiek (SKML) that included 16 international hepcidin MPs. The design included 12 human serum samples that allowed us to evaluate accuracy, linearity, precision and standardization potential. We manufactured, value-assigned, and validated a high-level calibrator in a similar manner to the existing low- and middle-level sRM. Results: The pilot PT confirmed logistical feasibility of an annual scheme. Most MPs demonstrated linearity (R2>0.99) and precision (duplicate CV>12.2%), although the need for EQA was shown by large variability in accuracy. The high-level calibrator proved effective, reducing the inter-assay CV from 42.0% (unstandardized) to 14.0%, compared to 17.6% with the two-leveled set. The calibrator passed international homogeneity criteria and was assigned a value of 9.07±0.24 nmol/L. Conclusions: We established a framework for future PT to enable laboratory accreditation, which is essential to ensure quality of hepcidin measurement and its use in patient care. Additionally, we showed optimized standardization is possible by extending the current sRM with a third high calibrator, although international implementation of the sRM is a prerequisite for its success.


Asunto(s)
Hepcidinas/sangre , Acreditación , Recolección de Muestras de Sangre , Calibración , Cromatografía Líquida de Alta Presión , Ensayo de Inmunoadsorción Enzimática , Humanos , Laboratorios/normas , Garantía de la Calidad de Atención de Salud/normas , Control de Calidad , Estándares de Referencia , Espectrometría de Masas en Tándem
3.
Pediatr Blood Cancer ; 67(3): e28038, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31724793

RESUMEN

BACKGROUND: Use of serum hepcidin measurements in pediatrics would benefit from standardized age- and sex-specific reference ranges in children, in order to enable the establishment of clinical decision limits that are universally applicable. PROCEDURE: We measured serum hepcidin-25 levels in 266 healthy Dutch children aged 0.3-17 years, using an isotope dilution mass spectrometry assay, standardized with our commutable secondary reference material (RM), assigned by a candidate primary RM. RESULTS: We constructed age- and sex-specific values for serum hepcidin and its ratio with ferritin and transferrin saturation (TSAT). Serum hepcidin levels and hepcidin/ferritin and TSAT/hepcidin ratios were similar for both sexes. Serum hepcidin and hepcidin/ferritin ratio substantially declined after the age of 12 years and TSAT/hepcidin ratio gradually increased with increasing age. Serum hepcidin values for Dutch children <12 years (n = 170) and >12 years (n = 96) were 1.9 nmol/L (median); 0.1-13.1 nmol/L (p2.5-p97.5) and 0.9 nmol/L; 0.0-9.1 nmol/L, respectively. Serum ferritin was the most significant correlate of serum hepcidin in our study population, explaining 15.1% and 7.9% of variance in males and females, respectively. Multivariable linear regression analysis including age, blood sampling time, iron parameters, ALT, CRP, and body mass index as independent variables showed a statistically significant negative association between age as a dichotomous variable (≤12 vs >12 years) and log-transformed serum hepcidin levels in both sexes. CONCLUSIONS: We demonstrate that serum hepcidin relative to indicators of body iron is age dependent in children, suggesting that the set point of serum hepcidin relative to stored and circulating iron changes during childhood.


Asunto(s)
Biomarcadores/sangre , Índice de Masa Corporal , Ferritinas/sangre , Hepcidinas/sangre , Hierro/sangre , Transferrina/análisis , Adolescente , Factores de Edad , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Valores de Referencia , Factores Sexuales
4.
Clin Chem Lab Med ; 57(6): 864-872, 2019 05 27.
Artículo en Inglés | MEDLINE | ID: mdl-30485171

RESUMEN

Background Hepcidin concentrations measured by various methods differ considerably, complicating interpretation. Here, a previously identified plasma-based candidate secondary reference material (csRM) was modified into a serum-based two-leveled sRM. We validated its functionality to increase the equivalence between methods for international standardization. Methods We applied technical procedures developed by the International Consortium for Harmonization of Clinical Laboratory Results. The sRM, consisting of lyophilized serum with cryolyoprotectant, appeared commutable among nine different measurement procedures using 16 native human serum samples in a first round robin (RR1). Harmonization potential of the sRM was simulated in RR1 and evaluated in practice in RR2 among 11 measurement procedures using three native human plasma samples. Comprehensive purity analysis of a candidate primary RM (cpRM) was performed by state of the art procedures. The sRM was value assigned with an isotope dilution mass spectrometry-based candidate reference method calibrated using the certified pRM. Results The inter-assay CV without harmonization was 42.1% and 52.8% in RR1 and RR2, respectively. In RR1, simulation of harmonization with sRM resulted in an inter-assay CV of 11.0%, whereas in RR2 calibration with the material resulted in an inter-assay CV of 19.1%. Both the sRM and pRM passed international homogeneity criteria and showed long-term stability. We assigned values to the low (0.95±0.11 nmol/L) and middle concentration (3.75±0.17 nmol/L) calibrators of the sRM. Conclusions Standardization of hepcidin is possible with our sRM, which value is assigned by a pRM. We propose the implementation of this material as an international calibrator for hepcidin.


Asunto(s)
Ensayo de Inmunoadsorción Enzimática/métodos , Hepcidinas/sangre , Espectrometría de Masas en Tándem , Calibración , Cromatografía Líquida de Alta Presión/normas , Ensayo de Inmunoadsorción Enzimática/normas , Hepcidinas/normas , Humanos , Marcaje Isotópico , Estándares de Referencia , Espectrometría de Masas en Tándem/normas
5.
Clin Chem ; 62(7): 993-1001, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-27173010

RESUMEN

BACKGROUND: Absolute plasma hepcidin concentrations measured by various procedures differ substantially, complicating interpretation of results and rendering reference intervals method dependent. We investigated the degree of equivalence achievable by harmonization and the identification of a commutable secondary reference material to accomplish this goal. METHODS: We applied technical procedures to achieve harmonization developed by the Consortium for Harmonization of Clinical Laboratory Results. Eleven plasma hepcidin measurement procedures (5 mass spectrometry based and 6 immunochemical based) quantified native individual plasma samples (n = 32) and native plasma pools (n = 8) to assess analytical performance and current and achievable equivalence. In addition, 8 types of candidate reference materials (3 concentrations each, n = 24) were assessed for their suitability, most notably in terms of commutability, to serve as secondary reference material. RESULTS: Absolute hepcidin values and reproducibility (intrameasurement procedure CVs 2.9%-8.7%) differed substantially between measurement procedures, but all were linear and correlated well. The current equivalence (intermeasurement procedure CV 28.6%) between the methods was mainly attributable to differences in calibration and could thus be improved by harmonization with a common calibrator. Linear regression analysis and standardized residuals showed that a candidate reference material consisting of native lyophilized plasma with cryolyoprotectant was commutable for all measurement procedures. Mathematically simulated harmonization with this calibrator resulted in a maximum achievable equivalence of 7.7%. CONCLUSIONS: The secondary reference material identified in this study has the potential to substantially improve equivalence between hepcidin measurement procedures and contributes to the establishment of a traceability chain that will ultimately allow standardization of hepcidin measurement results.


Asunto(s)
Servicios de Laboratorio Clínico/normas , Hepcidinas/sangre , Cooperación Internacional , Humanos , Inmunoquímica , Modelos Lineales , Estándares de Referencia
6.
PLoS One ; 8(10): e75518, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24124495

RESUMEN

Mass spectrometry (MS)-based assays for the quantification of the iron regulatory hormone hepcidin are pivotal to discriminate between the bioactive 25-amino acid form that can effectively block the sole iron transporter ferroportin and other naturally occurring smaller isoforms without a known role in iron metabolism. Here we describe the design, validation and use of a novel stable hepcidin-25(+40) isotope as internal standard for quantification. Importantly, the relative large mass shift of 40 Da makes this isotope also suitable for easy-to-use medium resolution linear time-of-flight (TOF) platforms. As expected, implementation of hepcidin-25(+40) as internal standard in our weak cation exchange (WCX) TOF MS method yielded very low inter/intra run coefficients of variation. Surprisingly, however, in samples from kidney disease patients, we detected a novel peak (m/z 2673.9) with low intensity that could be identified as hepcidin-24 and had previously remained unnoticed due to peak interference with the formerly used internal standard. Using a cell-based bioassay it was shown that synthetic hepcidin-24 was, like the -22 and -20 isoforms, a significantly less potent inducer of ferroportin degradation than hepcidin-25. During prolonged storage of plasma at room temperature, we observed that a decrease in plasma hepcidin-25 was paralleled by an increase in the levels of the hepcidin-24, -22 and -20 isoforms. This provides first evidence that all determinants for the conversion of hepcidin-25 to smaller inactive isoforms are present in the circulation, which may contribute to the functional suppression of hepcidin-25, that is significantly elevated in patients with renal impairment. The present update of our hepcidin TOF MS assay together with improved insights in the source and preparation of the internal standard, and sample stability will further improve our understanding of circulating hepcidin and pave the way towards further optimization and standardization of plasma hepcidin assays.


Asunto(s)
Hepcidinas/sangre , Espectrometría de Masas/métodos , Isoformas de Proteínas/sangre , Humanos , Reproducibilidad de los Resultados , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción
7.
Clin Chem ; 59(3): 527-35, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23232066

RESUMEN

BACKGROUND: The iron-regulating hormone hepcidin is a promising biomarker in the diagnosis of iron disorders. Concentrations of hepcidin have been shown to increase during the day in individuals who are following a regular diet. It is currently unknown whether these increases are determined by an innate rhythm or by other factors. We aimed to assess the effect of dietary iron on hepcidin concentrations during the day. METHODS: Within a 7-day interval, 32 volunteers received an iron-deficient diet on 1 day and the same diet supplemented with 65 mg ferrous fumarate at 0815 and 1145 on another day. Blood was drawn to assess ferritin, hepcidin-25, and transferrin saturation (TS) throughout both days at 4 time points between 0800 (fasted) and 1600. A linear mixed model for repeated data was used to analyze the effect of iron intake on TS and hepcidin concentrations. RESULTS: Baseline values of hepcidin at 0800 correlated significantly with ferritin (r = 0.61). During the day of an iron-deficient diet the mean TS was similar both in men and in women, whereas hepcidin increased. During the day with iron supplementation the mean TS was significantly higher both in men and in women, and the mean hepcidin was moderately but significantly higher in women (1.0 nmol/L, 95% CI, 0.2-1.8) but not in men (0.0 nmol/L, 95% CI, -0.8 to 0.8). CONCLUSIONS: Our data demonstrate that ferritin sets the basal hepcidin concentrations and suggest that innate diurnal rhythm rather than dietary iron mediates the daily hepcidin variations. These findings will be useful for optimizing sampling protocols and will facilitate the interpretation of hepcidin as an iron biomarker.


Asunto(s)
Péptidos Catiónicos Antimicrobianos/sangre , Ritmo Circadiano , Hierro de la Dieta/administración & dosificación , Adolescente , Adulto , Suplementos Dietéticos , Femenino , Ferritinas/sangre , Hepcidinas , Humanos , Masculino , Persona de Mediana Edad , Transferrina/análisis
8.
Blood ; 117(25): e218-25, 2011 Jun 23.
Artículo en Inglés | MEDLINE | ID: mdl-21527524

RESUMEN

To date, concentrations of the promising biomarker hepcidin have only been assessed in serum of relatively small series of healthy volunteers and patients. We assessed age- and sex-stratified reference ranges of serum hepcidin concentration in a selected reference set and performed regression analyses to study associations between hepcidin and (biochemical) variables in a large, well-phenotyped sample of the general population (n = 2998). All participants filled out a questionnaire on lifestyle, health status, and medical history. Serum measurements of iron parameters, liver enzyme alanine aminotransferase, creatinine and C-reactive protein were available. Serum hepcidin concentrations were lower for premenopausal than for postmenopausal women (median, 4.1 nM vs 8.5 nM, respectively). Hepcidin concentrations in men were constant over age (median, 7.8 nM). Serum hepcidin was strongly associated with serum ferritin in men and women: ß-coefficient of log-transformed variables (95% confidence interval): 0.78 (0.74-0.82) and 0.83 (0.78-0.88), respectively. Additional significant, though less strong, associations were observed for C-reactive protein and total iron binding capacity in men and for total iron binding capacity, alanine aminotransferase, and glomerular filtration rate in women. Our study provides age- and sex-specific reference ranges of serum hepcidin concentration and indicates ferritin as the primary correlate of serum hepcidin concentration.


Asunto(s)
Péptidos Catiónicos Antimicrobianos/sangre , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Ensayo de Inmunoadsorción Enzimática , Femenino , Hepcidinas , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Análisis Multivariante , Valores de Referencia , Factores Sexuales
9.
Anal Biochem ; 389(2): 124-9, 2009 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-19341701

RESUMEN

The utility of urine and serum hepcidin measurements in the clinic depends on their reproducibility. We sought to expand our previous work on the within-subject variability and between-subject variability of this novel iron parameter in the serum and urine of 24 healthy controls by time-of-flight mass spectrometry at four different time points during the day. A linear mixed model for repeated data was used to distinguish three components of the total variability in the measurements: within-day/within-subject variability, between-subject variability, and additional residual or (pre)analytical variability. Differences in diurnal hepcidin patterns were observed between urine and serum. Urine levels remained similar during the course of the morning and increased significantly during the afternoon, whereas serum levels increased significantly throughout both the morning and afternoon. Furthermore, in serum the (pre)analytical variability (28.6%) was smaller than the between-subject (48.1%) and within-day/within-subject variability (30.3%) compared with urine variability (97.2% vs. 67.7 and 77.3%, respectively). High serum ferritin levels were associated with higher serum hepcidin levels but not with urine levels. Transferrin saturation did not correlate with hepcidin levels. To minimize variability, we recommend (i) standardizing for sampling time and (ii) measuring serum hepcidin levels.


Asunto(s)
Péptidos Catiónicos Antimicrobianos/sangre , Péptidos Catiónicos Antimicrobianos/orina , Ritmo Circadiano , Adolescente , Adulto , Antibacterianos/sangre , Antibacterianos/orina , Biomarcadores/sangre , Biomarcadores/orina , Femenino , Hepcidinas , Humanos , Masculino , Espectrometría de Masas , Persona de Mediana Edad , Estándares de Referencia , Reproducibilidad de los Resultados , Adulto Joven
10.
Br J Haematol ; 142(6): 979-85, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18557745

RESUMEN

HFE C282Y-homozygosity has been associated with low hepcidin expression, leading to increased ferritin levels. However, serum hepcidin protein levels have not been documented in humans. In the current study, we compared serum hepcidin levels of newly diagnosed HFE C282Y-homozygotes with (N = 15) and without (N = 7) elevated serum ferritin levels to levels of 40 controls (20 heterozygotes and 20 wild types). In addition, hepcidin levels of four C282Y homozygotes were investigated during the course of all phlebotomy treatment phases. Serum hepcidin levels were lower in HFE C282Y-homozygotes (median; 25th-75th percentile: 1.88; 0.78-2.77 nmol/l) compared to controls (2.74; 1.45-5.39). Hepcidin/ferritin ratios were also lower in homozygotes. Homozygotes with an elevated serum ferritin had a higher serum hepcidin but a lower hepcidin/ferritin ratio than those with normal ferritin (2.28; 1.62-3.23 nmol/l hepcidin vs. 0.80; 0.60-1.29 and 3.63; 2.72-7.59 pmol hepcidin/microg ferritin vs. 13.2; 5.15-14.2). Serum hepcidin decreased during the depletion phase of phlebotomy and remained low during maintenance. This study showed that serum hepcidin is innately low in HFE-related haemochromatosis. Elevated ferritin levels were associated with increased hepcidin levels while erythropoiesis lead to lower hepcidin levels. During depletion, therefore, hepcidin levels are decreased, which may exacerbate intestinal iron absorption.


Asunto(s)
Péptidos Catiónicos Antimicrobianos/sangre , Hemocromatosis/sangre , Antígenos de Histocompatibilidad Clase I/genética , Proteínas de la Membrana/genética , Adulto , Anciano , Eritropoyesis , Femenino , Ferritinas/sangre , Hemocromatosis/genética , Hemocromatosis/cirugía , Proteína de la Hemocromatosis , Hepcidinas , Homocigoto , Humanos , Masculino , Persona de Mediana Edad , Flebotomía
11.
Nat Genet ; 39(8): 977-83, 2007 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-17603485

RESUMEN

We performed a genome-wide association scan to search for sequence variants conferring risk of prostate cancer using 1,501 Icelandic men with prostate cancer and 11,290 controls. Follow-up studies involving three additional case-control groups replicated an association of two variants on chromosome 17 with the disease. These two variants, 33 Mb apart, fall within a region previously implicated by family-based linkage studies on prostate cancer. The risks conferred by these variants are moderate individually (allele odds ratio of about 1.20), but because they are common, their joint population attributable risk is substantial. One of the variants is in TCF2 (HNF1beta), a gene known to be mutated in individuals with maturity-onset diabetes of the young type 5. Results from eight case-control groups, including one West African and one Chinese, demonstrate that this variant confers protection against type 2 diabetes.


Asunto(s)
Cromosomas Humanos Par 17 , Diabetes Mellitus Tipo 2/genética , Factor Nuclear 1-beta del Hepatocito/genética , Neoplasias de la Próstata/genética , Estudios de Casos y Controles , Predisposición Genética a la Enfermedad , Haplotipos , Humanos , Masculino , Polimorfismo de Nucleótido Simple
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...