Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Muscle Nerve ; 69(4): 422-427, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38334356

RESUMEN

INTRODUCTION/AIMS: The clinical presentation of multifocal motor neuropathy (MMN) may mimic early amyotrophic lateral sclerosis (ALS) with predominant lower motor neuron (LMN) involvement, posing a diagnostic challenge. Both diseases have specific treatments and prognoses, highlighting the importance of early diagnosis. The aim of this study was to assess the diagnostic value of serum neurofilament light chain (NfL) in differentiating MMN from LMN dominant ALS. METHODS: NfL was measured in serum in n = 37 patients with MMN and n = 37 age- and sex-matched patients with LMN dominant ALS, to determine the diagnostic accuracy. Clinical and demographic data were obtained at the time of NfL sampling. RESULTS: Serum NfL concentration was significantly lower in MMN patients compared to ALS patients (mean 20.7 pg/mL vs. 59.4 pg/mL, p < .01). NfL demonstrated good diagnostic value in discriminating the two groups (AUC 0.985 [95% CI 0.963-1.000], sensitivity 94.6%, specificity 100%, cut-off 44.00 pg/mL). DISCUSSION: NfL could be a helpful tool in differentiating MMN from LMN dominant ALS in those patients in whom electrophysiological and clinical examinations remain inconclusive early in the diagnostic process.


Asunto(s)
Esclerosis Amiotrófica Lateral , Polineuropatías , Humanos , Esclerosis Amiotrófica Lateral/diagnóstico , Biomarcadores , Filamentos Intermedios , Pronóstico , Polineuropatías/diagnóstico , Proteínas de Neurofilamentos
2.
Brain Sci ; 13(4)2023 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-37190588

RESUMEN

(1) Background: This study aims to assess the diagnostic accuracy of parameters based on a combination of transcranial magnetic stimulation (TMS) and electrical stimulation (ES) in the differentiation between idiopathic and secondary facial palsy in a large cohort of patients. (2) Methods: Patients with unilateral facial palsy ≤7 days after symptom onset were included. Compound muscle action potential (CMAP) amplitudes were measured after stimulation of both facial nerves at (A) the internal acoustic meatus using TMS, CMAP-TMS, and (B) at the stylomastoid foramen using electrical stimulation, CMAP-ES. To express the degree of nerve dysfunction in the facial canal specifically, the amplitude reduction of the CMAP-TMS in relation to CMAP-ES was calculated and expressed as a percentage (amplitude reduction over the facial canal, ARFC). Receiver Operating Characteristic (ROC) curves were constructed to assess the diagnostic accuracy of ARFC as a marker to discriminate between patients with idiopathic and secondary facial palsy. (3) Results: Data from 498 patient records were analyzed. Idiopathic facial palsy was diagnosed in 424 patients, and secondary facial palsy in 74 patients. The area under the ROC curve for ARFC was 0.398. (4) Conclusions: The overall diagnostic accuracy of this method to differentiate secondary from idiopathic facial palsy is low.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...