Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Eur Radiol ; 27(8): 3460-3466, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28058481

RESUMEN

PURPOSE: To compare agreement between conventional B-mode ultrasound (US) and compression sonoelastography (SEL) of the common extensor tendons of the elbow with histological evaluation. MATERIALS AND METHODS: Twenty-six common extensor tendons were evaluated in 17 cadavers (11 females, median age 85 years and 6 males, median age 80 years). B-mode US was graded into: Grade 1, homogeneous fibrillar pattern; grade 2, hypoechoic areas and/or calcifications <30%; and grade 3 > 30%. SEL was graded into: Grade 1 indicated blue (hardest) to green (hard); grade 2 yellow (soft); and grade 3 red (softest). B-mode US, SEL, and a combined grading score incorporating both were compared to histological findings in 76 biopsies. RESULTS: Histological alterations were detected in 55/76 biopsies. Both modalities showed similar results (sensitivity, specificity, and accuracy 84%, 81%, and 83% for B-mode US versus 85%, 86%, and 86% for SEL, respectively, P > 0.3). However, a combination of both resulted in significant improvement in sensitivity (96%, P < 0.02) without significant change in specificity (81%, P < 0.3), yielding an improved overall accuracy (92%). CONCLUSION: Combined imaging of the extensor tendons with both modalities is superior to either modality alone for predicting the presence of pathologic findings on histology. KEY POINTS: • Combination of B-mode US and SEL proved efficiency in diagnosing lateral epicondylitis. • Combination of B-mode US and SEL in lateral epicondylitis correlates to histology. • Combination of both modalities provides improved sensitivity without loss of specificity.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Articulación del Codo/diagnóstico por imagen , Tendones/diagnóstico por imagen , Codo de Tenista/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Biopsia , Cadáver , Articulación del Codo/patología , Femenino , Humanos , Masculino , Sensibilidad y Especificidad , Tendones/patología , Codo de Tenista/patología , Ultrasonografía
2.
Radiology ; 267(3): 837-42, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23449953

RESUMEN

PURPOSE: To compare and determine the level of agreement of findings at conventional B-mode ultrasonography (US) and sonoelastography of the Achilles tendon with findings at histologic assessment. MATERIALS AND METHODS: This study was conducted with the approval of the institutional review boards, and all cadavers were in legal custody of the study institution. Thirteen Achilles tendons in 10 cadavers (four male, six female; age range, 70-90 years) were examined with B-mode US and sonoelastography. B-mode US grading was as follows: Grade 1 indicated a normal-appearing tendon with homogeneous fibrillar echotexture; grade 2, a focal fusiform or diffuse enlarged tendon; and grade 3, a hypoechoic area with or without tendon enlargement. Sonoelastography grading was as follows: Grade 1 indicated blue (hardest) to green (hard); grade 2, yellow (soft); and grade 3, red (softest). Twenty-five biopsy specimens from representative lesions of the middle and distal thirds of the Achilles tendons were evaluated histologically. The concordance of B-mode US grading compared with sonoelastographic grading was assessed by using κ analysis. RESULTS: With B-mode US and sonoelastography, all 11 tendon thirds of histologically normal tendons were verified as normal (grade 1). Sonoelastography depicted 14 of 14 (100%) tendon thirds with histologic degeneration (grade 2 or 3), whereas B-mode US could depict only 12 of 14 (86%) lesions (grade 2 or 3). Only moderate agreement between B-mode US and sonoelastography was seen (κ = 0.52, P < .001). CONCLUSION: Sonoelastography might help predict signs of histopathologic degeneration of Achilles tendinosis, potentially more sensitively than B-mode US.


Asunto(s)
Tendón Calcáneo/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad/métodos , Tendón Calcáneo/patología , Anciano , Anciano de 80 o más Años , Biopsia , Cadáver , Femenino , Humanos , Masculino
3.
Head Neck ; 35(2): 235-41, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22407962

RESUMEN

BACKGROUND: Irradiation results in impaired bone healing. Thus, osteosynthesis procedures are afflicted with increased failure rates. To improve osseointegration bone morphogenetic protein-2 (BMP-2) immobilized on nanocrystalline diamond (NCD)-coated implant surfaces might be 1 solution. METHODS: By 4 weeks after irradiation of pig's mandible with a dose of 60 Gy a fracture was accomplished. Osteosynthesis was performed either with titanium osteosynthesis screws or NCD-coated screws with immobilized BMP-2. Nonirradiated animals served as control. After 1, 2, 4, and 8 weeks screws were evaluated histologically. Bone biopsies were gained to extract mesenchymal stem or precursor cells (MSCs). RESULTS: MSCs after irradiation demonstrated a behavior comparable to that of unirradiated cells. Consequently, immobilized BMP-2 resulted in an initial increased bone contact ratio (p = .014) but demonstrated no sustainable effect compared with osseointegration in nonirradiated bone (p = .08). CONCLUSION: Immobilized BMP-2 demonstrates an osteoinductive effect in irradiated bone. MSCs as effector cells possess protective mechanisms to overcome the destructive effect of irradiation.


Asunto(s)
Proteína Morfogenética Ósea 2/farmacología , Tornillos Óseos , Materiales Biocompatibles Revestidos/farmacología , Mandíbula/efectos de la radiación , Fracturas Mandibulares/cirugía , Oseointegración/efectos de los fármacos , Animales , Diamante/farmacología , Modelos Animales de Enfermedad , Fijación de Fractura/instrumentación , Fijación de Fractura/métodos , Curación de Fractura/fisiología , Mandíbula/patología , Mandíbula/cirugía , Fracturas Mandibulares/diagnóstico por imagen , Dosis de Radiación , Radiografía , Distribución Aleatoria , Valores de Referencia , Sensibilidad y Especificidad , Propiedades de Superficie , Sus scrofa , Porcinos , Titanio/farmacología
4.
Plast Reconstr Surg ; 113(3): 961-6, 2004 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15108889

RESUMEN

The interrupted suture technique is most commonly used for microsurgical vascular anastomosis. For several reasons (e.g., exposure of suture material to blood, time needed), many attempts have been made to find other solutions. This article describes a new means of performing a microsurgical vascular anastomosis. The aim of this study was to show the feasibility and possible advantages of this new technique. The basic components at work here are a modified cuff and electrically generated heat used to unite the vessel walls. In this way, both endothelial layers are adapted without manipulating the inside of the vessel or leaving behind foreign matter. Various energy/coagulation time settings were used to perform arterial anastomoses (n = 42) in an isogeneic abdominal aorta interposition model in the rat. The quality of anastomosis was evaluated at days 1, 10, 21, and 120. Immediately after the welding process all anastomoses (n = 42) were patent. No stenosis was found at any observation time. Anastomosis time ranged from 3 to 18 minutes (average, 11 minutes). This new technique permits a vascular anastomosis to be performed easily and reliably with a high patency rate. With this technique, the authors are convinced that a skilled surgeon can create a high-quality anastomosis in a fraction of the time needed to sew an anastomosis.


Asunto(s)
Procedimientos Quirúrgicos Vasculares/instrumentación , Procedimientos Quirúrgicos Vasculares/métodos , Anastomosis Quirúrgica/instrumentación , Anastomosis Quirúrgica/métodos , Animales , Reproducibilidad de los Resultados , Porcinos , Factores de Tiempo
5.
J Ultrasound Med ; 23(3): 331-7, 2004 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15055779

RESUMEN

OBJECTIVE: To assess the value of 2 transducer positions for measurement of finger flexor tendon thickness by sonography. METHODS: Flexor tendon thickness of the third finger was measured sonographically by 2 independent investigators in 20 healthy volunteers (n = 40 fingers) and in 4 cadaveric specimens (n = 4 fingers). Flexor tendon thickness was measured at histologic examination in the cadaveric specimens. We defined the area of the A1 annular pulley as position I and the area of the A2 annular pulley as position II. Sonographic measurements were performed in transverse (dorsovolar and radioulnar) and longitudinal planes. Interobserver and intraobserver variabilities were evaluated by each investigator performing 3 measurements at each position. RESULTS: In position I, volunteers had flexor tendon thickness of 2.7 to 4.0 mm (mean +/- SD, 3.28 +/- 0.26 mm) longitudinally; transversally the thickness was 2.5 to 4.0 mm (mean, 3.34 +/- 0.29 mm) dorsovolar and 5.5 to 8.9 mm (mean, 7.34 +/- 0.71) radioulnar in position I. Position II revealed thickness of 3.2 to 4.2 mm (mean, 3.6 +/- 0.23 mm) longitudinally; transversally the thickness was 2.7 to 4.1 mm (mean, 3.4 +/- 0.27) dorsovolar and 4.3 to 6.8 mm (mean, 5.27 +/- 0.65) radioulnar. Interobserver and intraobserver variability for position I was better than for position II (P < .01 versus P < .05). Sonographic findings correlated excellently with histologic findings (r2 = 0.94). CONCLUSIONS: Standardized transducer positions for sonographic measurements of finger flexor tendon thickness showed good interobserver and intraobserver variability. Position I was found to be more reliable than position II.


Asunto(s)
Dedos/diagnóstico por imagen , Tendones/diagnóstico por imagen , Adulto , Femenino , Humanos , Masculino , Variaciones Dependientes del Observador , Transductores , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...