1.
Sensors (Basel) ; 24(20)2024 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-39460074

RESUMEN

Digital gait monitoring is increasingly used to assess locomotion and fall risk. The aim of this work is to analyze the changes in the foot-floor contact sequences of Parkinson's Disease (PD) patients in the year following the implantation of Deep Brain Stimulation (DBS). During their best-ON condition, 30 PD patients underwent gait analysis at baseline (T0), at 3 months after subthalamic nucleus DBS neurosurgery (T1), and at 12 months (T2) after subthalamic nucleus DBS neurosurgery. Thirty age-matched controls underwent gait analysis once. Each subject was equipped with bilateral foot-switches and a 5 min walk was recorded, including both straight-line and turnings. The walking speed, turning time, stride time variability, percentage of atypical gait cycles, stance, swing, and double support duration were estimated. Overall, the gait performance of PD patients improved after DBS, as also confirmed by the decrease in their UPDRS-III scores from 19.4 ± 1.8 to 10.2 ± 1.0 (T0 vs. T2) (p < 0.001). In straight-line walking, the percentages of atypical cycles of PD on the more affected side were 11.1 ± 1.5% (at T0), 3.1 ± 1.5% (at T1), and 5.1 ± 2.4% (at T2), while in controls it was 3.1 ± 1.3% (p < 0.0005). In turnings, this percentage was 13.7 ± 1.1% (at T0), 7.8 ± 1.1% (at T1), and 10.9 ± 1.8% (at T2), while in controls it was 8.1 ± 1.0% (p < 0.001). Therefore, in straight-line walking, the atypical cycles decreased by 72% at T1, and by 54% at T2 (with respect to baseline), while, in turnings, atypical cycles decreased by 43% at T1, and by 20% at T2. The percentage of atypical gait cycles proved an informative digital biomarker for quantifying PD gait changes after DBS, both in straight-line paths and turnings.


Asunto(s)
Estimulación Encefálica Profunda , Pie , Marcha , Enfermedad de Parkinson , Humanos , Enfermedad de Parkinson/terapia , Enfermedad de Parkinson/fisiopatología , Estimulación Encefálica Profunda/métodos , Masculino , Femenino , Persona de Mediana Edad , Marcha/fisiología , Anciano , Pie/fisiopatología , Análisis de la Marcha/métodos , Caminata/fisiología
2.
Physiol Meas ; 45(10)2024 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-39344952

RESUMEN

Objective.The accurate temporal analysis of muscle activations is of great importance in several research areas spanning from the assessment of altered muscle activation patterns in orthopaedic and neurological patients to the monitoring of their motor rehabilitation. Several studies have highlighted the challenge of understanding and interpreting muscle activation patterns due to the high cycle-by-cycle variability of the sEMG data. This makes it difficult to interpret results and to use sEMG signals in clinical practice. To overcome this limitation, this study aims at presenting a toolbox to help scientists easily characterize and assess muscle activation patterns during cyclical movements.Approach.CIMAP(Clustering for the Identification of Muscle Activation Patterns) is an open-source Python toolbox based on agglomerative hierarchical clustering that aims at characterizing muscle activation patterns during cyclical movements by grouping movement cycles showing similar muscle activity.Main results.From muscle activation intervals to the graphical representation of the agglomerative hierarchical clustering dendrograms, the proposed toolbox offers a complete analysis framework for enabling the assessment of muscle activation patterns. The toolbox can be flexibly modified to comply with the necessities of the scientist.CIMAPis addressed to scientists of any programming skill level working in different research areas such as biomedical engineering, robotics, sports, clinics, biomechanics, and neuroscience. CIMAP is freely available on GitHub (https://github.com/Biolab-PoliTO/CIMAP).Significance.CIMAPtoolbox offers scientists a standardized method for analyzing muscle activation patterns during cyclical movements.


Asunto(s)
Electromiografía , Movimiento , Programas Informáticos , Movimiento/fisiología , Humanos , Procesamiento de Señales Asistido por Computador , Análisis por Conglomerados , Músculo Esquelético/fisiología
3.
Sensors (Basel) ; 24(18)2024 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-39338864

RESUMEN

The aim of this contribution is to present a segmentation method for the identification of voluntary movements from inertial data acquired through a single inertial measurement unit placed on the subject's wrist. Inertial data were recorded from 25 healthy subjects while performing 75 consecutive reach-to-grasp movements. The approach herein presented, called DynAMoS, is based on an adaptive thresholding step on the angular velocity norm, followed by a statistics-based post-processing on the movement duration distribution. Post-processing aims at reducing the number of erroneous transitions in the movement segmentation. We assessed the segmentation quality of this method using a stereophotogrammetric system as the gold standard. Two popular methods already presented in the literature were compared to DynAMoS in terms of the number of movements identified, onset and offset mean absolute errors, and movement duration. Moreover, we analyzed the sub-phase durations of the drinking movement to further characterize the task. The results show that the proposed method performs significantly better than the two state-of-the-art approaches (i.e., percentage of erroneous movements = 3%; onset and offset mean absolute error < 0.08 s), suggesting that DynAMoS could make more effective home monitoring applications for assessing the motion improvements of patients following domicile rehabilitation protocols.


Asunto(s)
Fuerza de la Mano , Movimiento , Humanos , Masculino , Adulto , Femenino , Movimiento/fisiología , Fuerza de la Mano/fisiología , Algoritmos , Fenómenos Biomecánicos/fisiología , Muñeca/fisiología , Adulto Joven
4.
Stud Health Technol Inform ; 316: 889-893, 2024 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-39176936

RESUMEN

The use of heart sounds for the assessment of the hemodynamic condition of the heart in telemonitoring applications is object of wide research at date. Many different approaches have been tried out for the analysis of the first (S1) and second (S2) heart sounds, but their morphological interpretation is still to be explored: in fact, the sound morphology is not unique and this impact the separability of the heart sounds components with methods based on envelopes or model optimization. In this study, we propose a method to stratify S1 and S2 according to their morphology to explore their diversity and increase their morphological interpretability. The method we propose is based on unsupervised learning, which we obtain using the cascade of four Self-Organizing Maps (SOMs) of decreasing dimensions. When tested on a publicly available heart sounds dataset, the proposed clustering approach proved to be robust and consistent, with over 80% of the heartbeats of the same patient being clustered together. The identified heart sounds templates highlight differences in the time and energy domains which may open to new directions of analysis in the future.


Asunto(s)
Ruidos Cardíacos , Aprendizaje Automático no Supervisado , Ruidos Cardíacos/fisiología , Humanos , Fonocardiografía , Procesamiento de Señales Asistido por Computador
5.
Stud Health Technol Inform ; 314: 155-159, 2024 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-38785023

RESUMEN

Among its main benefits, telemonitoring enables personalized management of chronic diseases by means of biomarkers extracted from signals. In these applications, a thorough quality assessment is required to ensure the reliability of the monitored parameters. Motion artifacts are a common problem in recordings with wearable devices. In this work, we propose a fully automated and personalized method to detect motion artifacts in multimodal recordings devoted to the monitoring of the Cardiac Time Intervals (CTIs). The detection of motion artifacts was carried out by using template matching with a personalized template. The method yielded a balanced accuracy of 86%. Moreover, it proved effective to decrease the variability of the estimated CTIs by at least 17%. Our preliminary results show that personalized detection of motion artifacts improves the robustness of the assessment CTIs and opens to the use in wearable systems.


Asunto(s)
Artefactos , Telemedicina , Humanos , Dispositivos Electrónicos Vestibles , Reproducibilidad de los Resultados , Monitoreo Fisiológico/métodos , Electrocardiografía , Procesamiento de Señales Asistido por Computador
6.
Bioengineering (Basel) ; 11(4)2024 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-38671788

RESUMEN

Timely and reliable fetal monitoring is crucial to prevent adverse events during pregnancy and delivery. Fetal phonocardiography, i.e., the recording of fetal heart sounds, is emerging as a novel possibility to monitor fetal health status. Indeed, due to its passive nature and its noninvasiveness, the technique is suitable for long-term monitoring and for telemonitoring applications. Despite the high share of literature focusing on signal processing, no previous work has reviewed the technological hardware solutions devoted to the recording of fetal heart sounds. Thus, the aim of this scoping review is to collect information regarding the acquisition devices for fetal phonocardiography (FPCG), focusing on technical specifications and clinical use. Overall, PRISMA-guidelines-based analysis selected 57 studies that described 26 research prototypes and eight commercial devices for FPCG acquisition. Results of our review study reveal that no commercial devices were designed for fetal-specific purposes, that the latest advances involve the use of multiple microphones and sensors, and that no quantitative validation was usually performed. By highlighting the past and future trends and the most relevant innovations from both a technical and clinical perspective, this review will represent a useful reference for the evaluation of different acquisition devices and for the development of new FPCG-based systems for fetal monitoring.

7.
Artículo en Inglés | MEDLINE | ID: mdl-37906487

RESUMEN

The aim of this study was to investigate balance performance and muscle synergies during a Single-Limb Stance (SLS) task in individuals with Chronic Ankle Instability (CAI) and a group of healthy controls. Twenty individuals with CAI and twenty healthy controls were asked to perform a 30-second SLS task in Open-Eyes (OE) and Closed-Eyes (CE) conditions while standing on a force platform with the injured or the dominant limb, respectively. The activation of 13 muscles of the lower limb, hip, and back was recorded by means of surface electromyography. Balance performance was assessed by identifying the number and the duration of SLS epochs, and the Root-Mean-Square (RMS) in Antero-Posterior (AP) and Medio-Lateral (ML) directions of the body-weight normalized ground reaction forces. The optimal number of synergies, weight vectors, and activation coefficients were also analyzed. CAI group showed a higher number and a shorter duration of SLS epochs and augmented ground reaction force RMS in both AP and ML directions compared to controls. Both groups showed an increase in the RMS in AP and ML forces in CE compared to OE. Both groups showed 4 optimal synergies in CE, while controls showed 5 synergies in OE. CAI showed a significantly higher weight of knee flexor muscles in both OE and CE. In conclusion, muscle synergies analysis provided an in-depth knowledge of motor control mechanisms in CAI individuals. They showed worse balance performance, a lower number of muscle synergies in a CE condition and abnormal knee flexor muscle activation compared to healthy controls.


Asunto(s)
Tobillo , Inestabilidad de la Articulación , Humanos , Extremidad Inferior , Músculo Esquelético/fisiología , Electromiografía , Articulación del Tobillo/fisiología , Equilibrio Postural/fisiología , Enfermedad Crónica
8.
Sensors (Basel) ; 23(13)2023 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-37448089

RESUMEN

The home monitoring of patients affected by chronic heart failure (CHF) is of key importance in preventing acute episodes. Nevertheless, no wearable technological solution exists to date. A possibility could be offered by Cardiac Time Intervals extracted from simultaneous recordings of electrocardiographic (ECG) and phonocardiographic (PCG) signals. Nevertheless, the recording of a good-quality PCG signal requires accurate positioning of the stethoscope over the chest, which is unfeasible for a naïve user as the patient. In this work, we propose a solution based on multi-source PCG. We designed a flexible multi-sensor array to enable the recording of heart sounds by inexperienced users. The multi-sensor array is based on a flexible Printed Circuit Board mounting 48 microphones with a high spatial resolution, three electrodes to record an ECG and a Magneto-Inertial Measurement Unit. We validated the usability over a sample population of 42 inexperienced volunteers and found that all subjects could record signals of good to excellent quality. Moreover, we found that the multi-sensor array is suitable for use on a wide population of at-risk patients regardless of their body characteristics. Based on the promising findings of this study, we believe that the described device could enable the home monitoring of CHF patients soon.


Asunto(s)
Ruidos Cardíacos , Humanos , Procesamiento de Señales Asistido por Computador , Corazón , Electrocardiografía , Electrodos
9.
Sensors (Basel) ; 23(8)2023 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-37112261

RESUMEN

The analysis of the stability of human gait may be effectively performed when estimates of the base of support are available. The base of support area is defined by the relative position of the feet when they are in contact with the ground and it is closely related to additional parameters such as step length and stride width. These parameters may be determined in the laboratory using either a stereophotogrammetric system or an instrumented mat. Unfortunately, their estimation in the real world is still an unaccomplished goal. This study aims at proposing a novel, compact wearable system, including a magneto-inertial measurement unit and two time-of-flight proximity sensors, suitable for the estimation of the base of support parameters. The wearable system was tested and validated on thirteen healthy adults walking at three self-selected speeds (slow, comfortable, and fast). Results were compared with the concurrent stereophotogrammetric data, used as the gold standard. The root mean square errors for the step length, stride width and base of support area varied from slow to high speed between 10-46 mm, 14-18 mm, and 39-52 cm2, respectively. The mean overlap of the base of support area as obtained with the wearable system and with the stereophotogrammetric system ranged between 70% and 89%. Thus, this study suggested that the proposed wearable solution is a valid tool for the estimation of the base of support parameters out of the laboratory.


Asunto(s)
Caminata , Dispositivos Electrónicos Vestibles , Adulto , Humanos , Marcha , Pie , Fotogrametría
10.
Sci Rep ; 13(1): 6997, 2023 04 28.
Artículo en Inglés | MEDLINE | ID: mdl-37117317

RESUMEN

The aim of this study is to quantitatively assess motor control changes in Parkinson's disease (PD) patients after bilateral deep brain stimulation of the subthalamic nucleus (STN-DBS), based on a novel muscle synergy evaluation approach. A group of 20 PD patients evaluated at baseline (before surgery, T0), at 3 months (T1), and at 12 months (T2) after STN-DBS surgery, as well as a group of 20 age-matched healthy control subjects, underwent an instrumented gait analysis, including surface electromyography recordings from 12 muscles. A smaller number of muscle synergies was found in PD patients (4 muscle synergies, at each time point) compared to control subjects (5 muscle synergies). The neuromuscular robustness of PD patients-that at T0 was smaller with respect to controls (PD T0: 69.3 ± 2.2% vs. Controls: 77.6 ± 1.8%, p = 0.004)-increased at T1 (75.8 ± 1.8%), becoming not different from that of controls at T2 (77.5 ± 1.9%). The muscle synergies analysis may offer clinicians new knowledge on the neuromuscular structure underlying PD motor types of behavior and how they can improve after electroceutical STN-DBS therapy.


Asunto(s)
Estimulación Encefálica Profunda , Enfermedad de Parkinson , Núcleo Subtalámico , Humanos , Enfermedad de Parkinson/cirugía , Núcleo Subtalámico/fisiología , Músculos , Electromiografía
11.
Stud Health Technol Inform ; 298: 159-160, 2022 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-36073476

RESUMEN

Certification of Medical Device Software (MDS) according to the EU Medical Device Regulation 2017/745 requires demonstrating safety and effectiveness. Thus, the syllabus of a course on MDS development must provide tools for addressing these issues. To assure safety, risk analysis has to be performed using a four-step procedure. Effectiveness could be demonstrated by literature systematic review combined with meta-analysis, to compare the MDS performances with those of similar tools.


Asunto(s)
Certificación , Programas Informáticos , Humanos , Legislación de Dispositivos Médicos , Metaanálisis como Asunto , Revisiones Sistemáticas como Asunto
12.
Sensors (Basel) ; 21(21)2021 Oct 29.
Artículo en Inglés | MEDLINE | ID: mdl-34770493

RESUMEN

Gait analysis applications in clinics are still uncommon, for three main reasons: (1) the considerable time needed to prepare the subject for the examination; (2) the lack of user-independent tools; (3) the large variability of muscle activation patterns observed in healthy and pathological subjects. Numerical indices quantifying the muscle coordination of a subject could enable clinicians to identify patterns that deviate from those of a reference population and to follow the progress of the subject after surgery or completing a rehabilitation program. In this work, we present two user-independent indices. First, a muscle-specific index (MFI) that quantifies the similarity of the activation pattern of a muscle of a specific subject with that of a reference population. Second, a global index (GFI) that provides a score of the overall activation of a muscle set. These two indices were tested on two groups of healthy and pathological children with encouraging results. Hence, the two indices will allow clinicians to assess the muscle activation, identifying muscles showing an abnormal activation pattern, and associate a functional score to every single muscle as well as to the entire muscle set. These opportunities could contribute to facilitating the diffusion of surface EMG analysis in clinics.


Asunto(s)
Marcha , Músculo Esquelético , Niño , Electromiografía , Humanos
13.
Sensors (Basel) ; 21(21)2021 Oct 30.
Artículo en Inglés | MEDLINE | ID: mdl-34770552

RESUMEN

The signal quality limits the applicability of phonocardiography at the patients' domicile. This work proposes the signal-to-noise ratio of the recorded signal as its main quality metrics. Moreover, we define the minimum acceptable values of the signal-to-noise ratio that warrantee an accuracy of the derived parameters acceptable in clinics. We considered 25 original heart sounds recordings, which we corrupted by adding noise to decrease their signal-to-noise ratio. We found that a signal-to-noise ratio equal to or higher than 14 dB warrants an uncertainty of the estimate of the valve closure latencies below 1 ms. This accuracy is higher than that required by most clinical applications. We validated the proposed method against a public database, obtaining results comparable to those obtained on our sample population. In conclusion, we defined (a) the signal-to-noise ratio of the phonocardiographic signal as the preferred metric to evaluate its quality and (b) the minimum values of the signal-to-noise ratio required to obtain an uncertainty of the latency of heart sound components compatible with clinical applications. We believe these results are crucial for the development of home monitoring systems aimed at preventing acute episodes of heart failure and that can be safely operated by naïve users.


Asunto(s)
Ruidos Cardíacos , Procesamiento de Señales Asistido por Computador , Algoritmos , Humanos , Fonocardiografía , Relación Señal-Ruido
14.
J Neuroeng Rehabil ; 18(1): 153, 2021 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-34674720

RESUMEN

BACKGROUND: The accurate temporal analysis of muscle activation is of great interest in many research areas, spanning from neurorobotic systems to the assessment of altered locomotion patterns in orthopedic and neurological patients and the monitoring of their motor rehabilitation. The performance of the existing muscle activity detectors is strongly affected by both the SNR of the surface electromyography (sEMG) signals and the set of features used to detect the activation intervals. This work aims at introducing and validating a powerful approach to detect muscle activation intervals from sEMG signals, based on long short-term memory (LSTM) recurrent neural networks. METHODS: First, the applicability of the proposed LSTM-based muscle activity detector (LSTM-MAD) is studied through simulated sEMG signals, comparing the LSTM-MAD performance against other two widely used approaches, i.e., the standard approach based on Teager-Kaiser Energy Operator (TKEO) and the traditional approach, used in clinical gait analysis, based on a double-threshold statistical detector (Stat). Second, the effect of the Signal-to-Noise Ratio (SNR) on the performance of the LSTM-MAD is assessed considering simulated signals with nine different SNR values. Finally, the newly introduced approach is validated on real sEMG signals, acquired during both physiological and pathological gait. Electromyography recordings from a total of 20 subjects (8 healthy individuals, 6 orthopedic patients, and 6 neurological patients) were included in the analysis. RESULTS: The proposed algorithm overcomes the main limitations of the other tested approaches and it works directly on sEMG signals, without the need for background-noise and SNR estimation (as in Stat). Results demonstrate that LSTM-MAD outperforms the other approaches, revealing higher values of F1-score (F1-score > 0.91) and Jaccard similarity index (Jaccard > 0.85), and lower values of onset/offset bias (average absolute bias < 6 ms), both on simulated and real sEMG signals. Moreover, the advantages of using the LSTM-MAD algorithm are particularly evident for signals featuring a low to medium SNR. CONCLUSIONS: The presented approach LSTM-MAD revealed excellent performances against TKEO and Stat. The validation carried out both on simulated and real signals, considering normal as well as pathological motor function during locomotion, demonstrated that it can be considered a powerful tool in the accurate and effective recognition/distinction of muscle activity from background noise in sEMG signals.


Asunto(s)
Memoria a Corto Plazo , Músculo Esquelético , Algoritmos , Electromiografía , Humanos , Redes Neurales de la Computación
15.
Gait Posture ; 90: 340-373, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34564008

RESUMEN

BACKGROUND: It has been reported that individuals with chronic ankle instability (CAI) show motor control abnormalities. The study of muscle activations by means of surface electromyography (sEMG) plays a key role in understanding some of the features of movement abnormalities. RESEARCH QUESTION: Do common sEMG activation abnormalities and strategies exists across different functional movements? METHODS: Literature review was conducted on PubMed, Web-of-Science and Cochrane databases. Studies published between 2000 and 2020 that assessed muscle activations by means of sEMG during any type of functional task in individuals with CAI, and used healthy individuals as controls, were included. Methodological quality was assessed using the modified Downs&Black checklist. Since the methodologies of different studies were heterogeneous, no meta-analysis was conducted. RESULTS: A total of 63 articles investigating muscle activations during gait, running, responses to perturbations, landing and hopping, cutting and turning; single-limb stance, star excursion balance task, forward lunges, ball-kicking, y-balance test and single-limb squatting were considered. Individuals with CAI showed a delayed activation of the peroneus longus in response to sudden inversion perturbations, in transitions between double- and single-limb stance, and in landing on unstable surfaces. Apparently, while walking on ground there are no differences between CAI and controls, walking on a treadmill increases the variability of muscles activations, probably as a "safety strategy" to avoid ankle inversion. An abnormal activation of the tibialis anterior was observed during a number of tasks. Finally, hip/spine muscles were activated before ankle muscles in CAI compared to controls. CONCLUSION: Though the methodology of the studies herein considered is heterogeneous, this review shows that the peroneal and tibialis anterior muscles have an abnormal activation in CAI individuals. These individuals also show a proximal muscle activation strategy during the performance of balance challenging tasks. Future studies should investigate whole-body muscle activation abnormalities in CAI individuals.


Asunto(s)
Tobillo , Inestabilidad de la Articulación , Articulación del Tobillo , Enfermedad Crónica , Electromiografía , Humanos , Músculo Esquelético
16.
Sensors (Basel) ; 21(18)2021 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-34577514

RESUMEN

The orientation of a magneto-inertial measurement unit can be estimated using a sensor fusion algorithm (SFA). However, orientation accuracy is greatly affected by the choice of the SFA parameter values which represents one of the most critical steps. A commonly adopted approach is to fine-tune parameter values to minimize the difference between estimated and true orientation. However, this can only be implemented within the laboratory setting by requiring the use of a concurrent gold-standard technology. To overcome this limitation, a Rigid-Constraint Method (RCM) was proposed to estimate suboptimal parameter values without relying on any orientation reference. The RCM method effectiveness was successfully tested on a single-parameter SFA, with an average error increase with respect to the optimal of 1.5 deg. In this work, the applicability of the RCM was evaluated on 10 popular SFAs with multiple parameters under different experimental scenarios. The average residual between the optimal and suboptimal errors amounted to 0.6 deg with a maximum of 3.7 deg. These encouraging results suggest the possibility to properly tune a generic SFA on different scenarios without using any reference. The synchronized dataset also including the optical data and the SFA codes are available online.


Asunto(s)
Algoritmos , Heurística , Fenómenos Biomecánicos , Fenómenos Magnéticos , Magnetismo
17.
Sensors (Basel) ; 21(15)2021 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-34372315

RESUMEN

It is important to find objective biomarkers for evaluating gait in Parkinson's Disease (PD), especially related to the foot and lower leg segments. Foot-switch signals, analyzed through Statistical Gait Analysis (SGA), allow the foot-floor contact sequence to be characterized during a walking session lasting five-minutes, which includes turnings. Gait parameters were compared between 20 PD patients and 20 age-matched controls. PDs showed similar straight-line speed, cadence, and double-support compared to controls, as well as typical gait-phase durations, except for a small decrease in the flat-foot contact duration (-4% of the gait cycle, p = 0.04). However, they showed a significant increase in atypical gait cycles (+42%, p = 0.006), during both walking straight and turning. A forefoot strike, instead of a "normal" heel strike, characterized the large majority of PD's atypical cycles, whose total percentage was 25.4% on the most-affected and 15.5% on the least-affected side. Moreover, we found a strong correlation between the atypical cycles and the motor clinical score UPDRS-III (r = 0.91, p = 0.002), in the subset of PD patients showing an abnormal number of atypical cycles, while we found a moderate correlation (r = 0.60, p = 0.005), considering the whole PD population. Atypical cycles have proved to be a valid biomarker to quantify subtle gait dysfunctions in PD patients.


Asunto(s)
Trastornos Neurológicos de la Marcha , Enfermedad de Parkinson , Pie , Marcha , Humanos , Enfermedad de Parkinson/diagnóstico , Caminata
18.
Sensors (Basel) ; 21(10)2021 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-34064615

RESUMEN

In motor control studies, the 90% thresholding of variance accounted for (VAF) is the classical way of selecting the number of muscle synergies expressed during a motor task. However, the adoption of an arbitrary cut-off has evident drawbacks. The aim of this work is to describe and validate an algorithm for choosing the optimal number of muscle synergies (ChoOSyn), which can overcome the limitations of VAF-based methods. The proposed algorithm is built considering the following principles: (1) muscle synergies should be highly consistent during the various motor task epochs (i.e., remaining stable in time), (2) muscle synergies should constitute a base with low intra-level similarity (i.e., to obtain information-rich synergies, avoiding redundancy). The algorithm performances were evaluated against traditional approaches (threshold-VAF at 90% and 95%, elbow-VAF and plateau-VAF), using both a simulated dataset and a real dataset of 20 subjects. The performance evaluation was carried out by analyzing muscle synergies extracted from surface electromyographic (sEMG) signals collected during walking tasks lasting 5 min. On the simulated dataset, ChoOSyn showed comparable performances compared to VAF-based methods, while, in the real dataset, it clearly outperformed the other methods, in terms of the fraction of correct classifications, mean error (ME), and root mean square error (RMSE). The proposed approach may be beneficial to standardize the selection of the number of muscle synergies between different research laboratories, independent of arbitrary thresholds.


Asunto(s)
Músculo Esquelético , Caminata , Algoritmos , Electromiografía , Humanos
19.
Sensors (Basel) ; 21(7)2021 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-33916432

RESUMEN

The orientation of a magneto and inertial measurement unit (MIMU) is estimated by means of sensor fusion algorithms (SFAs) thus enabling human motion tracking. However, despite several SFAs implementations proposed over the last decades, there is still a lack of consensus about the best performing SFAs and their accuracy. As suggested by recent literature, the filter parameters play a central role in determining the orientation errors. The aim of this work is to analyze the accuracy of ten SFAs while running under the best possible conditions (i.e., their parameter values are set using the orientation reference) in nine experimental scenarios including three rotation rates and three commercial products. The main finding is that parameter values must be specific for each SFA according to the experimental scenario to avoid errors comparable to those obtained when the default parameter values are used. Overall, when optimally tuned, no statistically significant differences are observed among the different SFAs in all tested experimental scenarios and the absolute errors are included between 3.8 deg and 7.1 deg. Increasing the rotation rate generally leads to a significant performance worsening. Errors are also influenced by the MIMU commercial model. SFA MATLAB implementations have been made available online.

20.
Artículo en Inglés | MEDLINE | ID: mdl-33909568

RESUMEN

Machine-learning techniques are suitably employed for gait-event prediction from only surface electromyographic (sEMG) signals in control subjects during walking. Nevertheless, a reference approach is not available in cerebral-palsy hemiplegic children, likely due to the large variability of foot-floor contacts. This study is designed to investigate a machine-learning-based approach, specifically developed to binary classify gait events and to predict heel-strike (HS) and toe-off (TO) timing from sEMG signals in hemiplegic-child walking. To this objective, sEMG signals are acquired from five hemiplegic-leg muscles in nearly 2500 strides from 20 hemiplegic children, acknowledged as Winters' group 1 and 2. sEMG signals, segmented in overlapping windows of 600 samples (pace = 5 samples), are used to train a multi-layer perceptron model. Intra-subject and inter-subject experimental settings are tested. The best-performing intra-subject approach is able to provide in the hemiplegic population a mean classification accuracy (±SD) of 0.97±0.01 and a suitable prediction of HS and TO events, in terms of average mean absolute error (MAE, 14.8±3.2 ms for HS and 17.6±4.2 ms for TO) and F1-score (0.95±0.03 for HS and 0.92±0.07 for TO). These results outperform previous sEMG-based attempts in cerebral-palsy populations and are comparable with outcomes achieved by reference approaches in control populations. In conclusion, the findings of the study prove the feasibility of neural networks in predicting the two main gait events using surface EMG signals, also in condition of high variability of the signal to predict as in hemiplegic cerebral palsy.


Asunto(s)
Parálisis Cerebral , Parálisis Cerebral/complicaciones , Parálisis Cerebral/diagnóstico , Niño , Electromiografía , Marcha , Humanos , Aprendizaje Automático , Caminata