1.
Nat Commun ; 15(1): 5548, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38977667

RESUMEN

Lithium-ion batteries (LiBs) are used globally as a key component of clean and sustainable energy infrastructure, and emerging LiB technologies have incorporated a class of per- and polyfluoroalkyl substances (PFAS) known as bis-perfluoroalkyl sulfonimides (bis-FASIs). PFAS are recognized internationally as recalcitrant contaminants, a subset of which are known to be mobile and toxic, but little is known about environmental impacts of bis-FASIs released during LiB manufacture, use, and disposal. Here we demonstrate that environmental concentrations proximal to manufacturers, ecotoxicity, and treatability of bis-FASIs are comparable to PFAS such as perfluorooctanoic acid that are now prohibited and highly regulated worldwide, and we confirm the clean energy sector as an unrecognized and potentially growing source of international PFAS release. Results underscore that environmental impacts of clean energy infrastructure merit scrutiny to ensure that reduced CO2 emissions are not achieved at the expense of increasing global releases of persistent organic pollutants.

2.
Sci Total Environ ; 947: 174574, 2024 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-38981548

RESUMEN

Detection and monitoring of per- and polyfluoroalkyl substances (PFAS) in aquatic environments has become an increasingly higher priority of regulatory agencies as public concern for human intake of these chemicals continues to grow. While many methods utilize active sampling strategies ("grab samples") for precise PFAS quantitation, here we evaluate the efficacy of low-cost passive sampling devices (Solid Phase Adsorption Toxin Tracking, or SPATTs) for spatial and temporal PFAS assessment of aquatic systems. For this study, passive samplers were initially deployed in North Carolina along the Cape Fear River during the summer and fall of 2016 and 2017. These were originally intended for the detection of microcystins and monitoring potentially harmful algal blooms, though this period also coincided with occurrences of PFAS discharge from a local fluorochemical manufacturer into the river. Additional samplers were then deployed in 2022 to evaluate changes in PFAS fingerprint and abundances. Assessment of PFAS showed legacy compounds were observed across almost all sampling sites over all 3 years (PFHxS, PFOS, PFHxA, etc.), while emerging replacement PFAS (e.g., Nafion byproducts) were predominantly localized downstream from the manufacturer. Furthermore, samplers deployed downstream from the manufacturer in 2022 noted sharp decreases in observed signal for replacement PFAS in comparison to samplers deployed in 2016 and 2017, indicating mitigation and remediation efforts in the area were able to reduce localized fluorochemical contamination.


Asunto(s)
Monitoreo del Ambiente , Fluorocarburos , Contaminantes Químicos del Agua , Monitoreo del Ambiente/métodos , Contaminantes Químicos del Agua/análisis , Fluorocarburos/análisis , North Carolina , Espectrometría de Movilidad Iónica/métodos , Ríos/química , Espectrometría de Masas/métodos , Adsorción
3.
Water Environ Res ; 96(8): e11091, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39072849

RESUMEN

Perfluoroalkyl and polyfluoroalkyl substances (PFAS) are widespread groundwater contaminants and are present in over 7000 drinking water wells near a North Carolina (NC) PFAS plant (Chemours). To understand options available to affected residents, we used new and previously existing water quality data to investigate deeper aquifers as alternate drinking water supplies and compared the regulatory responses near Chemours and three other PFAS production facilities with nearby contaminated wells. Data from >100 wells show that GenX concentrations decrease with increasing depth through the four aquifers in the study area: surficial, Black Creek, Upper Cape Fear, and bedrock. This illustrates the extent of vertical PFAS penetration through the aquifer sequence following roughly 40 years of atmospheric emissions. Detailed data on 143 water quality parameters in nine deep wells (two Upper Cape Fear, seven bedrock) revealed only eight exceedances of drinking water standards (one each for arsenic, perfluorooctanoic acid [PFOA], iron, chloride, and gross alpha, and three for manganese) and nine exceedances of health advisories (all for sodium). Regulatory responses to PFAS contamination of wells in four states included mention of deeper wells as an alternate water source only for nonresidential users in NC and residential users in Vermont. The bedrock aquifer is currently used by some residents and may be a viable alternative to shallower groundwater, though arsenic treatment may be beneficial at some deep wells and long-term sustainability of the aquifer should be evaluated. PRACTITIONER POINTS: GenX concentrations decreased with increasing depth in four aquifers near a PFAS plant. A few exceedances of drinking water standards and health advisories were found in deep bedrock wells. New bedrock wells could be part of the response to PFAS issues in shallower wells. In the long term, deep bedrock wells might be a less expensive option for some residents.


Asunto(s)
Agua Potable , Fluorocarburos , Contaminantes Químicos del Agua , Pozos de Agua , North Carolina , Fluorocarburos/análisis , Contaminantes Químicos del Agua/análisis , Agua Potable/química , Monitoreo del Ambiente , Calidad del Agua , Agua Subterránea/química
4.
Environ Int ; 186: 108615, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38582061

RESUMEN

Compost is widely used in agriculture as fertilizer while providing a practical option for solid municipal waste disposal. However, compost may also contain per- and polyfluoroalkyl substances (PFAS), potentially impacting soils and leading to PFAS entry into food chains and ultimately human exposure risks via dietary intake. This study examined how compost affects the bioavailability and uptake of eight PFAS (two ethers, three fluorotelomer sulfonates, and three perfluorosulfonates) by lettuce (Lactuca sativa) grown in commercial organic compost-amended, PFAS spiked soils. After 50 days of greenhouse experiment, PFAS uptake by lettuce decreased (by up to 90.5 %) with the increasing compost amendment ratios (0-20 %, w/w), consistent with their decreased porewater concentrations (by 30.7-86.3 %) in compost-amended soils. Decreased bioavailability of PFAS was evidenced by the increased in-situ soil-porewater distribution coefficients (Kd) (by factors of 1.5-7.0) with increasing compost additions. Significant negative (or positive) correlations (R2 ≥ 0.55) were observed between plant bioaccumulation (or Kd) and soil organic carbon content, suggesting that compost amendment inhibited plant uptake of PFAS mainly by increasing soil organic carbon and enhancing PFAS sorption. However, short-chain PFAS alternatives (e.g., perfluoro-2-methoxyacetic acid (PFMOAA)) were effectively translocated to shoots with translocation factors > 2.9, increasing their risks of contamination in leafy vegetables. Our findings underscore the necessity for comprehensive risk assessment of compost-borne PFAS when using commercial compost products in agricultural lands.


Asunto(s)
Compostaje , Fluorocarburos , Lactuca , Contaminantes del Suelo , Suelo , Contaminantes del Suelo/metabolismo , Contaminantes del Suelo/análisis , Compostaje/métodos , Suelo/química , Fluorocarburos/metabolismo , Fluorocarburos/análisis , Lactuca/metabolismo , Disponibilidad Biológica , Agricultura/métodos
9.
J Expo Sci Environ Epidemiol ; 34(1): 97-107, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38195989

RESUMEN

BACKGROUND: A fluorochemical facility near Fayetteville, North Carolina, emitted per- and polyfluoroalkyl ether acids (PFEAs), a subgroup of per- and polyfluoroalkyl substances (PFAS), to air. OBJECTIVE: Analyze PFAS in private wells near the facility and in blood from well users to assess relationships between PFEA levels in water and serum. METHODS: In 2019, we recruited private well users into the GenX Exposure Study and collected well water and blood samples. We targeted 26 PFAS (11 PFEAs) in water and 27 PFAS (9 PFEAs) in serum using liquid chromatography-mass spectrometry. We used regression modeling to explore relationships between water and serum PFAS. For the only PFEA detected frequently in water and serum, Nafion byproduct 2, we used generalized estimating equation (GEE) models to assess well water exposure metrics and then adjusted for covariates that may influence Nafion byproduct 2 serum concentrations. RESULTS: We enrolled 153 participants ages 6 and older (median = 56 years) using 84 private wells. Most wells (74%) had ≥6 detectable PFEAs; median ∑PFEAs was 842 ng/L (interquartile range = 197-1760 ng/L). Low molecular weight PFEAs (PMPA, HFPO-DA [GenX], PEPA, PFO2HxA) were frequently detected in well water, had the highest median concentrations, but were not detectable in serum. Nafion byproduct 2 was detected in 73% of wells (median = 14 ng/L) and 56% of serum samples (median = 0.2 ng/mL). Cumulative dose (well concentration × duration at address) was positively associated with Nafion byproduct 2 serum levels and explained the most variability (10%). In the adjusted model, cumulative dose was associated with higher Nafion byproduct 2 serum levels while time outside the home was associated with lower levels. IMPACT: PFAS are a large class of synthetic, fluorinated chemicals. Fluorochemical facilities are important sources of environmental PFAS contamination globally. The fluorochemical industry is producing derivatives of perfluoroalkyl acids, including per- and polyfluoroalkyl ether acids (PFEAs). PFEAs have been detected in various environmental samples but information on PFEA-exposed populations is limited. While serum biomonitoring is often used for PFAS exposure assessment, serum biomarkers were not good measures of long-term exposure to low molecular weight PFEAs in a private well community. Environmental measurements and other approaches besides serum monitoring will be needed to better characterize PFEA exposure.


Asunto(s)
Éter , Polímeros de Fluorocarbono , Fluorocarburos , Propionatos , Humanos , Suero , North Carolina , Éteres de Etila , Éteres
10.
Water Res ; 249: 120956, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38103444

RESUMEN

Anion exchange (IX) is a readily implementable water treatment method that can effectively remove per- and polyfluoroalkyl substances (PFAS). The overarching objective of this research was to predict PFAS removal in full- or pilot-scale packed-bed IX resin contactors from rapid small-scale column test (RSSCT) data. Specific objectives were to (1) assess the effects of IX resin crushing on total anion exchange capacity and packed bed density, (2) determine the effects of initial PFAS concentration on PFAS uptake capacity, (3) determine the rate-limiting step controlling PFAS uptake kinetics, (4) determine the effects of hydraulic loading rate on PFAS uptake capacity, and (5) link constant diffusivity RSSCT data to pilot test data to develop a scale-up protocol. Experiments were conducted with two single-use IX resins and three water matrices, including coagulated surface water and groundwater. Crushing IX resin did not substantially change the bed density and total anion exchange capacity, but the morphology of particles changed from almost perfectly spherical to irregularly shaped. PFAS uptake capacity was independent of influent PFAS concentrations in the 30-300 ng/L range. This finding facilitated the development of an RSSCT scale-up approach because influent PFAS concentrations in RSSCTs and corresponding pilot tests often differ. Biot number values and data from interrupted RSSCTs demonstrated that film diffusion or a combination of film diffusion and intraparticle diffusion controls the rate of PFAS uptake by IX resins. From RSSCTs with identical empty bed contact times but different hydraulic loading rates (vf), PFAS uptake capacity was found to be a function of the square root of the product of Sherwood number and particle shape factor (Sh×ϕ). Using a constant diffusivity RSSCT design with a reduced vf, full- or pilot-scale PFAS breakthrough data can therefore be predicted by multiplying the bed volumes of water treated in the RSSCT by a factor of (Shpilot×ϕpilot)/(ShRSSCT×ϕRSSCT) . This research will support the design of future IX treatment processes in the context of PFAS remediation and drinking water treatment.


Asunto(s)
Fluorocarburos , Contaminantes Químicos del Agua , Resinas de Intercambio Aniónico , Contaminantes Químicos del Agua/análisis , Adsorción , Aniones
11.
Environ Sci Technol ; 57(48): 20159-20168, 2023 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-37934924

RESUMEN

Research on per- and polyfluoroalkyl substances (PFAS) frequently incorporates organofluorine measurements, particularly because they could support a class-based approach to regulation. However, standardized methods for organofluorine analysis in a broad suite of matrices are currently unavailable, including a method for extractable organofluorine (EOF) measured using combustion ion chromatography (CIC). Here, we report the results of an international interlaboratory comparison. Seven laboratories representing academia, government, and the private sector measured paired EOF and PFAS concentrations in groundwater and eel (Anguilla rostrata) from a site contaminated by aqueous film-forming foam. Among all laboratories, targeted PFAS could not explain all EOF in groundwater but accounted for most EOF in eel. EOF results from all laboratories for at least one replicate extract fell within one standard deviation of the interlaboratory mean for groundwater and five out of seven laboratories for eel. PFAS spike mixture recoveries for EOF measurements in groundwater and eel were close to the criterion (±30%) for standardized targeted PFAS methods. Instrumental operation of the CIC such as replicate sample injections was a major source of measurement uncertainty. Blank contamination and incomplete inorganic fluorine removal may introduce additional uncertainties. To elucidate the presence of unknown organofluorine using paired EOF and PFAS measurements, we recommend that analysts carefully consider confounding methodological uncertainties such as differences in precision between measurements, data processing steps such as blank subtraction and replicate analyses, and the relative recoveries of PFAS and other fluorine compounds.


Asunto(s)
Anguilla , Fluorocarburos , Agua Subterránea , Contaminantes Químicos del Agua , Animales , Fluorocarburos/análisis , Agua Subterránea/química , Agua , Flúor/análisis , Flúor/química , Contaminantes Químicos del Agua/análisis
12.
Environ Sci Technol ; 57(41): 15348-15355, 2023 10 17.
Artículo en Inglés | MEDLINE | ID: mdl-37801709

RESUMEN

To estimate half-lives for novel fluoroethers, the GenX Exposure Study obtained two serum measurements for per- and polyfluoroalkyl substances (PFAS) for 44 participants of age 12-86 years from North Carolina, collected 5 and 11 months after fluoroether discharges into the drinking water source were controlled. The estimated half-lives for these compounds were 127 days (95% confidence interval (95% CI) = 86, 243 days) for perfluorotetraoxadecanoic acid (PFO4DA), 296 days for Nafion byproduct 2 (95% CI = 176, 924 days), and 379 days (95% CI = 199, 3870 days) for perfluoro-3,5,7,9,11-pentaoxadodecanoic acid (PFO5DoA). Using these estimates and the literature values, a model was built that predicted PFAS half-lives using structural properties. Three chemical properties predicted 55% of the variance of PFAS half-lives based on 15 PFAS. A model with only molecular weight predicted 69% of the variance. Some properties can predict the half-lives of PFAS, but a deeper understanding is needed. These fluoroethers had biological half-lives longer than published half-lives for PFHxA and PFHpA (30-60 days) but shorter than those for PFOA and PFOS (800-1200 days). These are the first and possibly only estimates of human elimination half-lives of these fluoroethers.


Asunto(s)
Ácidos Alcanesulfónicos , Fluorocarburos , Contaminantes Químicos del Agua , Humanos , Niño , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Éteres , Contaminantes Químicos del Agua/análisis , Caprilatos , Fluorocarburos/análisis
13.
Environ Sci Technol ; 57(47): 18970-18980, 2023 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-37223990

RESUMEN

Per- and polyfluoroalkyl substances (PFAS) are widely used anthropogenic chemicals. Because of the strength of the carbon-fluorine bond, PFAS are not destroyed in typical water treatment processes. Sulfate (SO4•-) and hydroxyl (•OH) radicals can oxidize some PFAS, but the behavior of per- and polyfluoroalkyl ether acids (PFEAs) in processes involving SO4•- and •OH is poorly understood. In this study, we determined second-order rate constants (k) describing the oxidation of 18 PFAS, including 15 novel PFEAs, by SO4•- and •OH. Among the studied PFAS, 6:2 fluorotelomer sulfonate reacted most readily with •OH [k•OH = (1.1-1.2) × 107 M-1 s-1], while polyfluoroalkyl ether acids containing an -O-CFH- moiety reacted more slowly [k•OH = (0.5-1.0) × 106 M-1 s-1]. In the presence of SO4•-, polyfluoroalkyl ether acids with an -O-CFH- moiety reacted more rapidly [kSO4•- = (0.89-4.6) × 106 M-1 s-1] than perfluoroalkyl ether carboxylic acids (PFECAs) and a chloro-perfluoro-polyether carboxylic acid (ClPFPECA) [kSO4•- = (0.85-9.5) × 104 M-1 s-1]. For homologous series of perfluoroalkyl carboxylic acids, linear and branched monoether PFECAs, and multiether PFECAs, PFAS chain length had little impact on second-order rate constants. SO4•- reacted with the carboxylic acid headgroup of perfluoroalkyl carboxylic acids and PFECAs. In contrast, for polyfluoroalkyl ether carboxylic and sulfonic acids with an -O-CFH- moiety, the site of SO4•- attack was the -O-CFH- moiety. Perfluoroalkyl ether sulfonic acids were not oxidized by SO4•- and •OH under the conditions evaluated in this study.


Asunto(s)
Fluorocarburos , Contaminantes Químicos del Agua , Éter , Radical Hidroxilo , Sulfatos , Fluorocarburos/análisis , Éteres , Ácidos Sulfónicos , Ácidos Carboxílicos , Contaminantes Químicos del Agua/análisis
14.
Environ Sci Technol ; 57(13): 5203-5215, 2023 04 04.
Artículo en Inglés | MEDLINE | ID: mdl-36962006

RESUMEN

Air-water interfacial retention of poly- and perfluoroalkyl substances (PFASs) is increasingly recognized as an important environmental process. Herein, column transport experiments were used to measure air-water interfacial partitioning values for several perfluoroalkyl ethers and for PFASs derived from aqueous film-forming foam, while batch experiments were used to determine equilibrium Kia data for compounds exhibiting evidence of rate-limited partitioning. Experimental results suggest a Freundlich isotherm best describes PFAS air-water partitioning at environmentally relevant concentrations (101-106 ng/L). A multiparameter regression analysis for Kia prediction was performed for the 15 PFASs for which equilibrium Kia values were determined, assessing 246 possible combinations of 8 physicochemical and system properties. Quantitative structure-property relationships (QSPRs) based on three to four parameters provided predictions of high accuracy without model overparameterization. Two QSPRs (R2 values of 0.92 and 0.83) were developed using an assumed average Freundlich n value of 0.65 and validated across a range of relevant concentrations for perfluorooctane sulfonate (PFOS), perfluorooctanoate (PFOA), and hexafluoropropylene oxide-dimer acid (i.e., GenX). A mass action model was further modified to account for the changing ionic strength on PFAS air-water interfacial sorption. The final result was two distinct QSPRs for estimating PFAS air-water interfacial partitioning across a range of aqueous concentrations and ionic strengths.


Asunto(s)
Ácidos Alcanesulfónicos , Fluorocarburos , Contaminantes Químicos del Agua , Agua , Fluorocarburos/análisis , Éteres , Contaminantes Químicos del Agua/análisis , Concentración Osmolar
15.
Water Res ; 231: 119652, 2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-36702026

RESUMEN

1,4-Dioxane is a drinking water contaminant of emerging concern. Because conventional and many advanced drinking water treatment technologies are ineffective for 1,4-dioxane removal, cost-effective technologies for the removal of 1,4-dioxane at drinking water-relevant concentrations are needed. In this research, a gravity-fed, cometabolic biofiltration system was developed to degrade 1,4-dioxane that was spiked into coagulated, settled surface water at a concentration of ∼10 µg/L. Objectives were to determine whether cometabolic degradation of trace levels of 1,4-dioxane can be sustained using n-butane as primary substrate and whether filter media properties and empty bed contact time (EBCT) affect biofiltration efficiency. A mixed culture of bacteria derived from the Cape Fear River basin and previously enriched using isobutane served as inoculum for biologically active filters. Two granular activated carbons (GACs) with different grain sizes and one carbonaceous resin were used as attachment media, and n-butane served as the primary substrate for biologically active filters. Non-inoculated controls with the same media were evaluated in parallel to distinguish between biological and adsorptive removals of 1,4-dioxane. For the duration of the pilot study (>3 months), 1,4-dioxane was degraded in inoculated biofilters receiving n-butane. In control filters containing larger and smaller grain GAC, 1,4-dioxane broke through completely within 750 and 1250 bed volumes, respectively, corresponding to 15 to 30 days of operation at an EBCT of 30 min. 1,4-Dioxane removal increased with increasing EBCT in all biologically active filters. At an EBCT of 30 min, the biologically active GAC filter containing the larger-grain GAC removed on average 87% of 1,4-dioxane at pseudo steady-state. When the hydraulic loading rate was decreased to achieve an overall EBCT of 60 min, 1,4-dioxane was removed to <1 µg/L in the biologically active GAC filter containing the larger-grain GAC. Activity-based labeling showed the presence of catalytically active monooxygenases in backwash water from biologically active filters that degraded 1,4-dioxane. Amplicon sequencing results showed that while taxa shifted after the initial inoculation of biologically active filters, taxa in biologically active filters remained more similar to the inoculum than those in the non-inoculated control filters. Overall, results of this research demonstrate that cometabolic degradation of 1,4-dioxane at trace levels is possible for extended periods of time in inoculated biofilters that receive n-butane as primary substrate.


Asunto(s)
Agua Potable , Contaminantes Químicos del Agua , Purificación del Agua , Proyectos Piloto , Contaminantes Químicos del Agua/análisis , Purificación del Agua/métodos , Carbón Orgánico/química , Filtración/métodos
16.
Water Res ; 230: 119522, 2023 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-36577256

RESUMEN

Perfluoroalkyl ether carboxylic acids (PFECAs) are a group of emerging recalcitrant contaminants that are being developed to replace legacy per- and polyfluoroalkyl substances (PFAS) in industrial applications and that are generated as by-products in fluoropolymer manufacturing. Here, we report on the removal and destruction of four structurally different PFECAs using an integrated anion exchange resin (AER) and electrochemical oxidation (ECO) treatment train. Results from this work illustrated that (1) flow-through columns packed with PFAS-selective AERs are highly effective for the removal of PFECAs and (2) PFECA affinity is strongly correlated with their hydrophobic features. Regeneration of the spent resin columns revealed that high percentage (e.g., 80%) of organic cosolvent is necessary for achieving 60-100% PFECA release, and regeneration efficiency was higher for a macroporous resin than a gel-type resin. Treatment of spent regenerants showed (1) >99.99% methanol removal was achieved by distillation, (2) >99.999% conversion of the four studied PFECAs was achieved during the ECO treatment of the still bottoms after 24 hours with an energy per order of magnitude of PFECA removal (EE/O) <1.03 kWh/m3 of total groundwater treated, and (3) >85% of the organic fluorine was recovered as inorganic fluoride. Trifluoroacetic acid (TFA), perfluoropropionic acid (PFPrA), and perfluoro-2-methoxyacetic acid (PFMOAA) were confirmed via high-resolution mass spectrometry as transformation products (TPs) in the treated still bottoms, and two distinctive degradation schemes and four reaction pathways are proposed for the four PFECAs. Lastly, dissolved organic matter (DOM) inhibited uptake, regeneration, and oxidation of PFECAs throughout the treatment train, suggesting pretreatment steps targeting DOM removal can enhance the system's treatment efficiency. Results from this work provide guidelines for developing effective separation-concentration-destruction treatment trains and meaningful insights for achieving PFECA destruction in impacted aquatic systems.


Asunto(s)
Fluorocarburos , Contaminantes Químicos del Agua , Éter , Resinas de Intercambio Aniónico , Ácidos Carboxílicos , Éteres , Fluorocarburos/análisis , Contaminantes Químicos del Agua/análisis
17.
Sci Total Environ ; 855: 158842, 2023 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-36122706

RESUMEN

Per- and polyfluoroalkyl substances (PFASs) are synthetic chemicals that are ubiquitous in environmental and biological systems, including human serum. PFASs are used in many products and industrial processes and are tied to numerous health effects. Due to multiple sources and exposure pathways, methods are needed to identify PFAS sources in communities to develop targeted interventions. We assessed effectiveness of three source apportionment methods (UNMIX, positive matrix factorization [PMF], and principal component analysis - multiple linear regression [PCA-MLR]) for identifying contributors to human serum PFAS concentrations in two highly exposed populations in Colorado and North Carolina where drinking water was contaminated via upstream sources, including a Space Force base and a fluorochemical manufacturing plant. UNMIX and PMF models extracted three to four potential PFAS exposure sources in the Colorado and North Carolina cohorts while PCA-MLR classified two in each cohort. No sources were characterized in NHANES (National Health and Nutrition Examination Study). Results suggest that these three methods can successfully identify sources in highly exposed populations. Future PFAS exposure research should focus on analyzing serum for an expanded PFAS panel, identifying cohorts with other distinct point source exposures, and combining biological and environmental data to better understand source apportionment results in the context of PFAS toxicokinetic behavior.


Asunto(s)
Ácidos Alcanesulfónicos , Agua Potable , Fluorocarburos , Contaminantes Químicos del Agua , Humanos , Fluorocarburos/análisis , Encuestas Nutricionales , Agua Potable/análisis , Análisis Multivariante , Análisis de Componente Principal , Ácidos Alcanesulfónicos/análisis , Contaminantes Químicos del Agua/análisis
18.
Environ Sci Technol ; 56(22): 15470-15477, 2022 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-36265138

RESUMEN

Anion-exchange (AE) sorbents are gaining in popularity for the remediation of anionic per- and polyfluoroalkyl substances (PFAS) in water. However, it is unclear how hydrophobic and electrostatic interactions contribute to anionic PFAS retention. The goal of this study was to understand the effects of PFAS chain length and head group on electrostatic interactions between PFAS and an aminopropyl AE phase. Liquid chromatography-mass spectrometry (LC-MS) was used with an aminopropyl AE guard column to find relative retention times. The average electrostatic potential (EPavg) of each PFAS was calculated, which correlated positively with the PFAS chromatographic retention time, demonstrating the value of EPavg as a proxy for predicting electrostatic interactions between PFAS and the aminopropyl AE phase. The order of greatest to lowest PFAS AE affinity for an aminopropyl column based on chromatographic retention times and electrostatic interactions was n:3 fluorotelomer carboxylic acids (n:3 FtAs) > n:2 fluorotelomer carboxylic acids (n:2 FtAs) > perfluoroalkyl carboxylates (PFCAs) > perfluoroalkyl sulfonamides (FASAs) ∼ n:2 fluorotelomer sulfonates (n:2 FtSs) > perfluoroalkyl sulfonates (PFSAs). This study introduces a methodology for qualitatively characterizing electrostatic interactions between PFAS and AE phases and highlights that electrostatic interactions alone cannot explain the affinity of PFAS for AE resins in water treatment/remediation scenarios.


Asunto(s)
Fluorocarburos , Contaminantes Químicos del Agua , Purificación del Agua , Fluorocarburos/análisis , Contaminantes Químicos del Agua/análisis , Ácidos Carboxílicos/análisis , Aniones
19.
Environ Health Perspect ; 130(9): 97002, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-36069575

RESUMEN

BACKGROUND: Residents of Wilmington, North, Carolina, were exposed to drinking water contaminated by fluoroethers and legacy per- and polyfluoroalkyl substances (PFAS), such as perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS), with fluoroether exposure occurring from 1980 to 2017. PFOA and PFOS have previously been associated with metabolic dysfunction; however, few prior studies have examined associations between other PFAS and lipid levels. OBJECTIVES: We measured the association between serum fluoroether and legacy PFAS levels and various cholesterol outcomes. METHODS: Participants in the GenX Exposure Study contributed nonfasting blood samples in November 2017 and May 2018 that were analyzed for 20 PFAS (10 legacy, 10 fluoroethers) and serum lipids [total cholesterol, low-density lipoprotein (LDL), high-density lipoprotein (HDL), triglycerides] and calculated non-HDL cholesterol. We estimated covariate-adjusted associations between quartiles of exposure to each of the PFAS measures (as well as the summed concentrations of legacy PFAS, fluoroethers, and all 10 targeted PFAS) and lipid outcomes by fitting inverse probability of treatment weighted linear regressions. RESULTS: In this cross-sectional study of 326 participants (age range 6-86 y), eight PFAS were detected in >50% of the population. For PFOS and perfluorononanoic acid (PFNA), non-HDL cholesterol was approximately 5mg/dL higher per exposure quartile increase: [PFOS: 4.89; 95% confidence interval (CI): 0.10, 9.68 and PFNA: 5.25 (95% CI: 0.39, 10.1)], whereas total cholesterol was approximately 6mg/dL higher per quartile [PFOS: 5.71 (95% CI: 0.38, 11.0), PFNA: 5.92 (95% CI: 0.19, 11.7)]. In age-stratified analyses, associations were strongest among the oldest participants. Two fluoroethers were associated with higher HDL, whereas other fluoroether compounds were not associated with serum lipid levels. DISCUSSION: PFNA and PFOS were associated with higher levels of total and non-HDL cholesterol, with associations larger in magnitude among older adults. In the presence of these legacy PFAS, fluoroethers appeared to be associated with HDL but not non-HDL lipid measures. https://doi.org/10.1289/EHP11033.


Asunto(s)
Ácidos Alcanesulfónicos , Agua Potable , Contaminantes Ambientales , Fluorocarburos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Colesterol , Estudios Transversales , Humanos , Lípidos , Persona de Mediana Edad , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...