Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 14(1): 2939, 2024 02 05.
Artículo en Inglés | MEDLINE | ID: mdl-38316884

RESUMEN

Diagnosis of malignant pleural effusion (MPE) is made by cytological examination of pleural fluid or histological examination of pleural tissue from biopsy. Unfortunately, detection of malignancy using cytology has an overall sensitivity of 50%, and is dependent upon tumor load, volume of fluid assessed, and cytopathologist experience. The diagnostic yield of pleural fluid cytology is also compromised by low abundance of tumor cells or when morphology is obscured by inflammation or reactive mesothelial cells. A reliable molecular marker that may complement fluid cytology for the diagnosis of malignant pleural effusion is needed. The purpose of this study was to establish a molecular diagnostic approach based on pleural effusion cell-free DNA methylation analysis for the differential diagnosis of malignant pleural effusion and benign pleural effusion. This was a blind, prospective case-control biomarker study. We recruited 104 patients with pleural effusion for the study. We collected pleural fluid from patients with: MPE (n = 48), indeterminate pleural effusion in subjects with known malignancy or IPE (n = 28), and benign PE (n = 28), and performed the Sentinel-MPE liquid biopsy assay. The methylation level of Sentinel-MPE was markedly higher in the MPE samples compared to BPE control samples (p < 0.0001) and the same tendency was observed relative to IPE (p = 0.004). We also noted that the methylation signal was significantly higher in IPE relative to BPE (p < 0.001). We also assessed the diagnostic efficiency of the Sentinel-MPE test by performing receiver operating characteristic analysis (ROC). For the ROC analysis we combined the malignant and indeterminate pleural effusion groups (n = 76) and compared against the benign group (n = 28). The detection sensitivity and specificity of the Sentinel-MPE test was high (AUC = 0.912). The Sentinel-MPE appears to have better performance characteristics than cytology analysis. However, combining Sentinel-MPE with cytology analysis could be an even more effective approach for the diagnosis of MPE. The Sentinel-MPE test can discriminate between BPE and MPE. The Sentinel-MPE liquid biopsy test can detect aberrant DNA in several different tumor types. The Sentinel-MPE test can be a complementary tool to cytology in the diagnosis of MPE.


Asunto(s)
Ácidos Nucleicos Libres de Células , Derrame Pleural Maligno , Derrame Pleural , Humanos , Derrame Pleural Maligno/diagnóstico , Derrame Pleural Maligno/genética , Derrame Pleural Maligno/patología , Metilación de ADN , Biomarcadores de Tumor/metabolismo , Derrame Pleural/diagnóstico , Derrame Pleural/patología
2.
Res Sq ; 2023 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-37886511

RESUMEN

Background: Diagnosis of malignant pleural effusion (MPE) is made by cytological examination of pleural fluid or histological examination of pleural tissue from biopsy. Unfortunately, detection of malignancy using cytology has an overall sensitivity of 50%, and is dependent upon tumor load, volume of fluid assessed, and cytopathologist experience. The diagnostic yield of pleural fluid cytology is also compromised by low abundance of tumor cells or when morphology is obscured by inflammation or reactive mesothelial cells. A reliable molecular marker that may complement fluid cytology malignant pleural effusion diagnosis is needed. The purpose of this study was to establish a molecular diagnostic approach based on pleural effusion cell-free DNA methylation analysis for the differential diagnosis of malignant pleural effusion and benign pleural effusion. Results: This was a blind, prospective case-control biomarker study. We recruited 104 patients with pleural effusion for the study. We collected pleural fluid from patients with: MPE (n = 48), PPE (n = 28), and benign PE (n = 28), and performed the Sentinel-MPE liquid biopsy assay. The methylation level of Sentinel-MPE was markedly higher in the MPE samples compared to BPE control samples (p < 0.0001) and the same tendency was observed relative to PPE (p = 0.004). We also noted that the methylation signal was significantly higher in PPE relative to BPE (p < 0.001). We also assessed the diagnostic efficiency of the Sentinel-MPE test by performing receiver operating characteristic analysis (ROC). For the ROC analysis we combined the malignant and paramalignant groups (n = 76) and compared against the benign group (n = 28). The detection sensitivity and specificity of the Sentinel-MPE test was high (AUC = 0.912). The Sentinel-MPE appears to have better performance characteristics than cytology analysis. However, combining Sentinel-MPE with cytology analysis could be an even more effective approach for the diagnosis of MPE. Conclusions: The Sentinel-MPE test can discriminate between BPE and MPE. The Sentinel-MPE liquid biopsy test can detect aberrant DNA in several different tumor types. The Sentinel-MPE test can be a complementary tool to cytology in the diagnosis of MPE.

3.
Biomedicines ; 9(5)2021 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-34066047

RESUMEN

SARS-CoV-2, the cause of COVID19, has caused a pandemic that has infected more than 80 M and killed more than 1.6 M persons worldwide. In the US as of December 2020, it has infected more than 32 M people while causing more than 570,000 deaths. As the pandemic persists, there has been a public demand to reopen schools and university campuses. To consider these demands, it is necessary to rapidly identify those individuals infected with the virus and isolate them so that disease transmission can be stopped. In the present study, we examined the sensitivity of the Quidel Rapid Antigen test for use in screening both symptomatic and asymptomatic individuals at the University of Arizona from June to August 2020. A total of 885 symptomatic and 1551 asymptomatic subjects were assessed by antigen testing and real-time PCR testing. The sensitivity of the test for both symptomatic and asymptomatic persons was between 82 and 90%, with some caveats.

4.
Immunity ; 53(5): 925-933.e4, 2020 11 17.
Artículo en Inglés | MEDLINE | ID: mdl-33129373

RESUMEN

We conducted a serological study to define correlates of immunity against SARS-CoV-2. Compared to those with mild coronavirus disease 2019 (COVID-19) cases, individuals with severe disease exhibited elevated virus-neutralizing titers and antibodies against the nucleocapsid (N) and the receptor binding domain (RBD) of the spike protein. Age and sex played lesser roles. All cases, including asymptomatic individuals, seroconverted by 2 weeks after PCR confirmation. Spike RBD and S2 and neutralizing antibodies remained detectable through 5-7 months after onset, whereas α-N titers diminished. Testing 5,882 members of the local community revealed only 1 sample with seroreactivity to both RBD and S2 that lacked neutralizing antibodies. This fidelity could not be achieved with either RBD or S2 alone. Thus, inclusion of multiple independent assays improved the accuracy of antibody tests in low-seroprevalence communities and revealed differences in antibody kinetics depending on the antigen. We conclude that neutralizing antibodies are stably produced for at least 5-7 months after SARS-CoV-2 infection.


Asunto(s)
Betacoronavirus/inmunología , Técnicas de Laboratorio Clínico/métodos , Infecciones por Coronavirus/epidemiología , Infecciones por Coronavirus/inmunología , Inmunidad Humoral , Neumonía Viral/epidemiología , Neumonía Viral/inmunología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Anticuerpos Neutralizantes/sangre , Anticuerpos Antivirales/sangre , Arizona/epidemiología , Betacoronavirus/aislamiento & purificación , COVID-19 , Prueba de COVID-19 , Infecciones por Coronavirus/sangre , Infecciones por Coronavirus/diagnóstico , Proteínas de la Nucleocápside de Coronavirus , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proteínas de la Nucleocápside/inmunología , Pandemias , Fosfoproteínas , Neumonía Viral/sangre , Neumonía Viral/diagnóstico , Prevalencia , Dominios y Motivos de Interacción de Proteínas , SARS-CoV-2 , Estudios Seroepidemiológicos , Glicoproteína de la Espiga del Coronavirus/química , Glicoproteína de la Espiga del Coronavirus/inmunología , Adulto Joven
5.
medRxiv ; 2020 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-32817969

RESUMEN

We conducted an extensive serological study to quantify population-level exposure and define correlates of immunity against SARS-CoV-2. We found that relative to mild COVID-19 cases, individuals with severe disease exhibited elevated authentic virus-neutralizing titers and antibody levels against nucleocapsid (N) and the receptor binding domain (RBD) and the S2 region of spike protein. Unlike disease severity, age and sex played lesser roles in serological responses. All cases, including asymptomatic individuals, seroconverted by 2 weeks post-PCR confirmation. RBD- and S2-specific and neutralizing antibody titers remained elevated and stable for at least 2-3 months post-onset, whereas those against N were more variable with rapid declines in many samples. Testing of 5882 self-recruited members of the local community demonstrated that 1.24% of individuals showed antibody reactivity to RBD. However, 18% (13/73) of these putative seropositive samples failed to neutralize authentic SARS-CoV-2 virus. Each of the neutralizing, but only 1 of the non-neutralizing samples, also displayed potent reactivity to S2. Thus, inclusion of multiple independent assays markedly improved the accuracy of antibody tests in low seroprevalence communities and revealed differences in antibody kinetics depending on the viral antigen. In contrast to other reports, we conclude that immunity is durable for at least several months after SARS-CoV-2 infection.

6.
J Bronchology Interv Pulmonol ; 26(2): 81-89, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29901536

RESUMEN

BACKGROUND: Trials suggest that bronchoscopic lung volume reduction (BLVR) with endobronchial valve (EBV) implantation may produce similar effects as lung volume reduction surgery, by inducing atelectasis and reducing hyperinflation through a minimally invasive procedure. This study sought to investigate the efficacy and safety of BLVR with EBV for advanced emphysema. METHODS: We searched PubMed, EMBASE, Web of Science, CINAHL, ClinicalTrials.gov, and Cochrane Library databases for randomized controlled trials comparing EBV implantation versus standard medical treatment or sham bronchoscopy. The main outcome of interest was the percentage change of forced expiratory volume in 1 second. RESULTS: Data analyzed from 5 randomized controlled trials with 703 patients revealed improvement in percentage change of forced expiratory volume in 1 second in EBV group compared with control group [weighted mean difference (WMD)=11.43; 95% confidence interval (CI), 6.05-16.80; P<0.0001] and improvement in the St. George's Respiratory Questionnaire score (WMD=-5.69; 95% CI, -8.67 to -2.70; P=0.0002). There is no difference shown in the 6-minute walking test (WMD=14.12; 95% CI, -4.71 to 32.95; P=0.14). The overall complication rate of EBV was not significantly different except for an increased rate of pneumothorax [relative risk (RR)=8.16; 95% CI, 2.21-30.11; P=0.002), any hemoptysis (RR=5.01; 95% CI, 1.12-22.49; P=0.04)] and valve migration (RR=8.64; 95% CI, 2.01-37.13; P=0.004). CONCLUSION: BLVR using EBV shows short-term improvement in lung function and quality of life, but with increased risk of minor hemoptysis, pneumothorax, and valve migration. Follow-up data on the studies are needed to determine its long-term efficacy.


Asunto(s)
Broncoscopía/métodos , Implantación de Prótesis/métodos , Enfisema Pulmonar/cirugía , Volumen Espiratorio Forzado , Hemoptisis/epidemiología , Humanos , Neumotórax/epidemiología , Complicaciones Posoperatorias/epidemiología , Prótesis e Implantes , Falla de Prótesis , Enfisema Pulmonar/fisiopatología , Ensayos Clínicos Controlados Aleatorios como Asunto , Resultado del Tratamiento , Prueba de Paso
7.
J Bronchology Interv Pulmonol ; 17(4): 348-50, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23168960

RESUMEN

Foreign body (FB) aspiration can be a life-threatening event. Although more common in children, FB aspiration can occur at any age. Symptoms related to FB aspiration range from coughing and shortness of breath to asphyxiation. Chest imaging can be nonspecific and infrequently identifies an FB. Herein, we describe a case of a 54-year-old male patient who aspirated an FB and experienced respiratory arrest. He failed to improve with conservative measures and required emergent bronchoscopy. He was found to have an FB in his proximal left mainstem bronchus that could not be removed using standard bronchoscopy and he was referred to our center for definitive care. We used a cryotherapy probe to remove the FB. We propose that cryotherapy is a useful tool to remove FBs that are soft and amenable to freezing.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...