Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Soc Cardiovasc Angiogr Interv ; 3(3Part B): 101293, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-39131219

RESUMEN

Background: Coronary artery disease (CAD) in patients with severe aortic stenosis (AS) is common and may be associated with worse outcomes. Computed tomography coronary angiography (CTCA) and fractional flow reserve derived from computed tomography (FFRCT) are tools for comprehensive coronary assessment. The utility and safety of CTCA and FFRCT in the work-up for transcatheter aortic valve replacement (TAVR) is not established, especially in an evolving landscape that involves younger TAVR patients. The FUTURE-AS Registry will assess the utility and safety of cardiac-optimized CTCA and FFRCT to evaluate CAD and guide referral for downstream invasive coronary angiography (ICA) in patients with severe AS being considered for TAVR. Methods: FUTURE-AS is an international, prospective, multicenter registry of patients with severe AS referred for TAVR being assessed for CAD with CTCA and FFRCT. The primary end point is the per-patient sensitivity and negative predictive value of CTCA and FFRCT for identifying anatomical and physiologically significant CAD compared to ICA and invasive FFR. The safety end point is the incidence of symptomatic hypotension or bradycardia requiring intervention following the administration of nitroglycerin or ß-blocker medications. Feasibility end points include the incidence of noninterpretable CTCA scans and CTCA scans not adequate for FFR analysis. Other utility end points include specificity, positive predictive value, and accuracy of CTCA and FFRCT. Lastly, the potential of a CTCA and FFRCT guided strategy to defer pre-TAVR ICA will be assessed. Conclusions: FUTURE-AS will characterize the utility, safety, and feasibility of CTCA and FFRCT for coronary assessment pre-TAVR.

2.
ACS Nano ; 2024 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-39137319

RESUMEN

Optical continuous glucose monitoring (CGM) systems are emerging for personalized glucose management owing to their lower cost and prolonged durability compared to conventional electrochemical CGMs. Here, we report a computational CGM system, which integrates a biocompatible phosphorescence-based insertable biosensor and a custom-designed phosphorescence lifetime imager (PLI). This compact and cost-effective PLI is designed to capture phosphorescence lifetime images of an insertable sensor through the skin, where the lifetime of the emitted phosphorescence signal is modulated by the local concentration of glucose. Because this phosphorescence signal has a very long lifetime compared to tissue autofluorescence or excitation leakage processes, it completely bypasses these noise sources by measuring the sensor emission over several tens of microseconds after the excitation light is turned off. The lifetime images acquired through the skin are processed by neural network-based models for misalignment-tolerant inference of glucose levels, accurately revealing normal, low (hypoglycemia) and high (hyperglycemia) concentration ranges. Using a 1 mm thick skin phantom mimicking the optical properties of human skin, we performed in vitro testing of the PLI using glucose-spiked samples, yielding 88.8% inference accuracy, also showing resilience to random and unknown misalignments within a lateral distance of ∼4.7 mm with respect to the position of the insertable sensor underneath the skin phantom. Furthermore, the PLI accurately identified larger lateral misalignments beyond 5 mm, prompting user intervention for realignment. The misalignment-resilient glucose concentration inference capability of this compact and cost-effective PLI makes it an appealing wearable diagnostics tool for real-time tracking of glucose and other biomarkers.

3.
Artículo en Inglés | MEDLINE | ID: mdl-39025758

RESUMEN

BACKGROUND: Angiographic assessment of left main coronary artery (LMCA) stenosis severity can be unreliable. In cases of ambiguity, intravascular ultrasound (IVUS) can be utilised with a minimal lumen area (MLA) of ≥6 â€‹mm2 an accepted threshold for safe deferral of revascularization. We sought to assess whether quantitative computer tomography coronary angiography (CTCA) measures could assist clinicians making LMCA revascularization decisions when compared with IVUS as gold standard. METHODS: Consecutive patients undergoing IVUS assessment of angiographically intermediate LMCA stenosis were included. All patients had undergone 320-slice CTCA <90 days prior to IVUS imaging. Offline quantitative assessment of IVUS- and CT-derived measures were undertaken with the cohort divided into those with significant (s-LMCA) versus non-significant (ns-LMCA) disease using the accepted IVUS threshold. RESULTS: Fifty-eight patients were included, with no difference in mean age (61.5 â€‹± â€‹12.2 vs. 59.7 â€‹± â€‹11.9 years, p â€‹= â€‹0.57), diabetic status (24.2% vs 16.0%, p â€‹= â€‹0.44) or other baseline demographics between groups. Patients with ns-LMCA had larger CT luminal area (8.64 â€‹± â€‹3.91 vs. 5.41 â€‹± â€‹1.54 â€‹mm2, p â€‹< â€‹0.001), larger minimal lumen diameter (MLD) (3.25 â€‹± â€‹0.74 vs. 2.56 â€‹± â€‹0.38 â€‹mm, p â€‹< â€‹0.001) and lower area stenosis (45.74 â€‹± â€‹18.10 vs. 60.93 â€‹± â€‹14.68%, p â€‹= â€‹0.001). There was a significant positive correlation between CTCA and IVUS MLA (r â€‹= â€‹0.68, p â€‹< â€‹0.001) and MLD (r â€‹= â€‹0.67, p â€‹< â€‹0.001). ROC analysis demonstrated CTCA MLA cut-off <8.29 â€‹mm2 provides the greatest negative predictive value and sensitivity in predicting the presence of significant LMCA disease. CONCLUSION: CTCA derived MLA and MLD have a strong correlation with IVUS. A CTCA derived MLA cut-off <8.29 â€‹mm2 showed greatest clinical utility for predicting the need for further assessment, based on IVUS gold standard.

4.
Artículo en Inglés | MEDLINE | ID: mdl-38752951

RESUMEN

BACKGROUND: A lesion-level risk prediction for acute coronary syndrome (ACS) needs better characterization. OBJECTIVES: This study sought to investigate the additive value of artificial intelligence-enabled quantitative coronary plaque and hemodynamic analysis (AI-QCPHA). METHODS: Among ACS patients who underwent coronary computed tomography angiography (CTA) from 1 month to 3 years before the ACS event, culprit and nonculprit lesions on coronary CTA were adjudicated based on invasive coronary angiography. The primary endpoint was the predictability of the risk models for ACS culprit lesions. The reference model included the Coronary Artery Disease Reporting and Data System, a standardized classification for stenosis severity, and high-risk plaque, defined as lesions with ≥2 adverse plaque characteristics. The new prediction model was the reference model plus AI-QCPHA features, selected by hierarchical clustering and information gain in the derivation cohort. The model performance was assessed in the validation cohort. RESULTS: Among 351 patients (age: 65.9 ± 11.7 years) with 2,088 nonculprit and 363 culprit lesions, the median interval from coronary CTA to ACS event was 375 days (Q1-Q3: 95-645 days), and 223 patients (63.5%) presented with myocardial infarction. In the derivation cohort (n = 243), the best AI-QCPHA features were fractional flow reserve across the lesion, plaque burden, total plaque volume, low-attenuation plaque volume, and averaged percent total myocardial blood flow. The addition of AI-QCPHA features showed higher predictability than the reference model in the validation cohort (n = 108) (AUC: 0.84 vs 0.78; P < 0.001). The additive value of AI-QCPHA features was consistent across different timepoints from coronary CTA. CONCLUSIONS: AI-enabled plaque and hemodynamic quantification enhanced the predictability for ACS culprit lesions over the conventional coronary CTA analysis. (Exploring the Mechanism of Plaque Rupture in Acute Coronary Syndrome Using Coronary Computed Tomography Angiography and Computational Fluid Dynamics II [EMERALD-II]; NCT03591328).

5.
ACS Appl Bio Mater ; 7(6): 3964-3980, 2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38809780

RESUMEN

Phosphorescence-based oxygen-sensing hydrogels are a promising platform technology for an upcoming generation of insertable biosensors that are smaller, softer, and potentially more biocompatible than earlier designs. However, much remains unknown about their long-term performance and biocompatibility in vivo. In this paper, we design and evaluate a range of hydrogel sensors that contain oxygen-sensitive phosphors stabilized by micro- and nanocarrier systems. These devices demonstrated consistently good performance and biocompatibility in young adult rats for over three months. This study thoroughly establishes the biocompatibility and long-term suitability of phosphorescence lifetime sensors in vivo, providing the groundwork for expansion of this platform technology into a family of small, unobtrusive biosensors for a range of clinically relevant metabolites.


Asunto(s)
Materiales Biocompatibles , Técnicas Biosensibles , Hidrogeles , Ensayo de Materiales , Nanocompuestos , Oxígeno , Oxígeno/metabolismo , Oxígeno/química , Animales , Hidrogeles/química , Materiales Biocompatibles/química , Nanocompuestos/química , Ratas , Tamaño de la Partícula , Reacción a Cuerpo Extraño/metabolismo , Mediciones Luminiscentes , Ratas Sprague-Dawley
6.
Int J Cardiol ; 410: 132216, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38821121

RESUMEN

BACKGROUND: Tyrosine kinase inhibitors (TKI), such as Dasatinib, are effective in the treatment of chronic myeloid leukemia (CML) but associated with development of pleural effusions (PE). The relationship between haemodynamic parameters identified on transthoracic echocardiogram (TTE) such as elevated estimated left atrial pressure (LAP), and PE development is unknown. This study aims to describe associations between Dasatinib, elevated LAP and PE. METHODS: This was a retrospective study of 71 CML patients who underwent TTE during treatment with various TKIs. Descriptive analysis was performed to identify associations between TKI use, PE and elevated LAP on TTE. Multivariate logistic regression was performed to identify predictors of elevated LAP. RESULTS: There were 36 patients treated with Dasatinib, 15 Nilotinib, and 20 Imatinib. Those treated with Dasatinib had higher rates of elevated LAP (44% vs 7% Nilotinib vs 10% Imatinib, p < 0.01) and PE (39% vs 7% vs 0%, p < 0.01). In the 15 patients who developed PE, 14 (93%) patients were treated with Dasatinib. Patients with PE had higher rates of elevated LAP (67% vs 16%, p < 0.01). Nineteen (26.8%) patients in the entire cohort had elevated LAP. After multivariate adjustment, Dasatinib (OR 33.50, 95% CI = 4.99-224.73, p < 0.01) and age (OR 1.12, 95% CI = 1.04-1.20, p < 0.01) were associated with elevated LAP. CONCLUSIONS: Among patients with CML, there was an association between Dasatinib use, PE and elevated LAP on TTE. These findings are hypothesis generating and further studies are required to evaluate the utility of elevated LAP on TTE as a novel marker for prediction and surveillance of PE.


Asunto(s)
Dasatinib , Leucemia Mielógena Crónica BCR-ABL Positiva , Derrame Pleural , Inhibidores de Proteínas Quinasas , Humanos , Dasatinib/efectos adversos , Dasatinib/uso terapéutico , Femenino , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Leucemia Mielógena Crónica BCR-ABL Positiva/tratamiento farmacológico , Derrame Pleural/epidemiología , Derrame Pleural/inducido químicamente , Anciano , Inhibidores de Proteínas Quinasas/efectos adversos , Inhibidores de Proteínas Quinasas/uso terapéutico , Adulto , Presión Atrial/fisiología , Presión Atrial/efectos de los fármacos , Ecocardiografía/métodos
8.
Circulation ; 150(8): 586-597, 2024 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-38742491

RESUMEN

BACKGROUND: Diffuse coronary artery disease affects the safety and efficacy of percutaneous coronary intervention (PCI). Pathophysiologic coronary artery disease patterns can be quantified using fractional flow reserve (FFR) pullbacks incorporating the pullback pressure gradient (PPG) calculation. This study aimed to establish the capacity of PPG to predict optimal revascularization and procedural outcomes. METHODS: This prospective, investigator-initiated, single-arm, multicenter study enrolled patients with at least one epicardial lesion with an FFR ≤0.80 scheduled for PCI. Manual FFR pullbacks were used to calculate PPG. The primary outcome of optimal revascularization was defined as an FFR ≥0.88 after PCI. RESULTS: A total of 993 patients with 1044 vessels were included. The mean FFR was 0.68±0.12, PPG 0.62±0.17, and the post-PCI FFR was 0.87±0.07. PPG was significantly correlated with the change in FFR after PCI (r=0.65 [95% CI, 0.61-0.69]; P<0.001) and demonstrated excellent predictive capacity for optimal revascularization (area under the receiver operating characteristic curve, 0.82 [95% CI, 0.79-0.84]; P<0.001). FFR alone did not predict revascularization outcomes (area under the receiver operating characteristic curve, 0.54 [95% CI, 0.50-0.57]). PPG influenced treatment decisions in 14% of patients, redirecting them from PCI to alternative treatment modalities. Periprocedural myocardial infarction occurred more frequently in patients with low PPG (<0.62) compared with those with focal disease (odds ratio, 1.71 [95% CI, 1.00-2.97]). CONCLUSIONS: Pathophysiologic coronary artery disease patterns distinctly affect the safety and effectiveness of PCI. PPG showed an excellent predictive capacity for optimal revascularization and demonstrated added value compared with an FFR measurement. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04789317.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Humanos , Intervención Coronaria Percutánea/efectos adversos , Enfermedad de la Arteria Coronaria/fisiopatología , Enfermedad de la Arteria Coronaria/terapia , Femenino , Masculino , Anciano , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
9.
J Cardiovasc Comput Tomogr ; 18(4): 337-344, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38789325

RESUMEN

BACKGROUND: Coronary CT angiography (CCTA) is well-established for diagnosis and stratification of coronary artery disease (CAD). Its usefulness in guiding percutaneous coronary interventions (PCI) and stent sizing is unknown. METHODS: This is a sub-analysis of the Precise Percutaneous Coronary Intervention Plan (P3) study (NCT03782688). We analyzed 65 vessels with matched CCTA and pre-PCI optical coherence tomography (OCT) assessment. The CCTA-guided stent size was defined by the mean distal reference lumen diameter rounded up to the nearest stent diameter. The OCT lumen-guided stent size was the mean distal reference lumen diameter rounded to the closest stent diameter. The agreement on stent diameters was determined with Kappa statistics, Passing-Bablok regression analysis, and the Bland-Altman method. RESULTS: The distal reference lumen diameter by CCTA and OCT were 2.75 â€‹± â€‹0.53 â€‹mm and 2.72 â€‹± â€‹0.55 â€‹mm (mean difference 0.06, limits of agreement -0.7 to 0.82). There were no proportional or systematic differences (coefficient A 1.06, 95% CI 0.84 to 1.3 and coefficient B -0.22, 95% CI -0.83 to 0.36) between methods. The agreement between the CCTA and OCT stent size was substantial (Cohen's weighted Kappa 0.74, 95% CI 0.64 to 0.85). Compared to OCT stent diameter, CCTA stent size was concordant in 52.3% of the cases; CCTA overestimated stent size in 20.0% and underestimated in 27.7%. CONCLUSION: CCTA accurately assessed the reference vessel diameter used for stent sizing. CCTA-based stent sizing showed a substantial agreement with OCT. CCTA allows for PCI planning and may aid in selecting stent diameter.


Asunto(s)
Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria , Vasos Coronarios , Intervención Coronaria Percutánea , Valor Predictivo de las Pruebas , Diseño de Prótesis , Stents , Tomografía de Coherencia Óptica , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Intervención Coronaria Percutánea/instrumentación , Masculino , Femenino , Reproducibilidad de los Resultados , Persona de Mediana Edad , Anciano
10.
J Am Heart Assoc ; 13(5): e032605, 2024 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-38390822

RESUMEN

BACKGROUND: Following percutaneous coronary intervention (PCI), optical coherence tomography provides prognosis information. The pullback pressure gradient is a novel index that discriminates focal from diffuse coronary artery disease based on fractional flow reserve pullbacks. We sought to investigate the association between coronary artery disease patterns, defined by coronary physiology, and optical coherence tomography after stent implantation in stable patients undergoing PCI. METHODS AND RESULTS: This multicenter, prospective, single-arm study was conducted in 5 countries (NCT03782688). Subjects underwent motorized fractional flow reserve pullbacks evaluation followed by optical coherence tomography-guided PCI. Post-PCI optical coherence tomography minimum stent area, stent expansion, and the presence of suboptimal findings such as incomplete stent apposition, stent edge dissection, and irregular tissue protrusion were compared between patients with focal versus diffuse disease. Overall, 102 patients (105 vessels) were included. Fractional flow reserve before PCI was 0.65±0.14, pullback pressure gradient was 0.66±0.14, and post-PCI fractional flow reserve was 0.88±0.06. The mean minimum stent area was 5.69±1.99 mm2 and was significantly larger in vessels with focal disease (6.18±2.12 mm2 versus 5.19±1.72 mm2, P=0.01). After PCI, incomplete stent apposition, stent edge dissection, and irregular tissue protrusion were observed in 27.6%, 10.5%, and 51.4% of the cases, respectively. Vessels with focal disease at baseline had a lower prevalence of incomplete stent apposition (11.3% versus 44.2%, P=0.002) and more irregular tissue protrusion (69.8% versus 32.7%, P<0.001). CONCLUSIONS: Baseline coronary pathophysiological patterns are associated with suboptimal imaging findings after PCI. Patients with focal disease had larger minimum stent area and a higher incidence of tissue protrusion, whereas stent malapposition was more frequent in patients with diffuse disease.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Humanos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Vasos Coronarios/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico/fisiología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Valor Predictivo de las Pruebas , Estudios Prospectivos , Tomografía de Coherencia Óptica/métodos , Resultado del Tratamiento
11.
Annu Rev Biomed Eng ; 26(1): 197-221, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38346276

RESUMEN

Insertable biosensor systems are medical diagnostic devices with two primary components: an implantable biosensor within the body and a wearable monitor that can remotely interrogate the biosensor from outside the body. Because the biosensor does not require a physical connection to the electronic monitor, insertable biosensor systems promise improved patient comfort, reduced inflammation and infection risk, and extended operational lifetimes relative to established percutaneous biosensor systems. However, the lack of physical connection also presents technical challenges that have necessitated new innovations in developing sensing chemistries, transduction methods, and communication modalities. In this review, we discuss the key developments that have made insertables a promising option for longitudinal biometric monitoring and highlight the essential needs and existing development challenges to realizing the next generation of insertables for extended-use diagnostic and prognostic devices.


Asunto(s)
Técnicas Biosensibles , Diseño de Equipo , Dispositivos Electrónicos Vestibles , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Humanos , Prótesis e Implantes , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos
12.
Melanoma Res ; 34(2): 134-141, 2024 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-38181115

RESUMEN

The objective of this study is to describe survival outcomes in patients with metastatic melanoma in a real-world setting receiving combination and single-agent immunotherapy outside the clinical trial context. We conducted a retrospective single-institution study of patients with metastatic melanoma in a real-world setting. Survival was calculated using log-rank test. Contingency tables were analyzed using Fisher's Exact test. CD8 + T-cell densities were measured using quantitative immunofluorescence and analyzed using Mann-Whitney U test. The median overall survival (OS) for 132 patients was 45.3 months. Brain metastasis did not confer a higher risk of death relative to liver and/or bone disease (39.53 versus 30.00 months, respectively; P  = 0.687). Anti-PD-1 monotherapy was the most common first-line treatment, received by 49.2% of patients. There was no significant difference in OS between patients receiving single-agent anti-PD-1 and combination anti-PD-1 plus CTLA-4 (39.4 months versus undefined; P  = 0.643). Patients treated with combination therapy were more likely to be alive without progression at the last follow-up than those who received monotherapy (70.4% versus 49.2%; P  = 0.0408). Median OS was 21.8 months after initiation of second-line therapy after anti-PD-1 monotherapy. CD8+ T-cell densities were higher in patients who achieved disease control on first-line immunotherapy ( P  = 0.013). In a real-world setting, patients with metastatic melanoma have excellent survival rates, and treatment benefit can be achieved even after progression on first-line therapy. Combination immunotherapy may produce more favorable long-term outcomes in a real-world setting. High pretreatment CD8+ T-cell infiltration correlates with immunotherapy efficacy.


Asunto(s)
Melanoma , Neoplasias Primarias Secundarias , Neoplasias Cutáneas , Humanos , Melanoma/tratamiento farmacológico , Estudios Retrospectivos , Neoplasias Cutáneas/tratamiento farmacológico , Inmunoterapia , Progresión de la Enfermedad
13.
Curr Probl Cancer ; 48: 101059, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38181630

RESUMEN

The early detection of cancer is a key goal of the National Cancer Plan formally released by the National Institutes of Health's (NIH) National Cancer Institute (NCI) in April 2023. To support this effort, many laboratories and vendors are developing multi-cancer detection (MCD) assays that interrogate blood and other bodily fluids for cancer-related biomarkers, most commonly circulating tumor DNA (ctDNA). While this approach holds promise for non-invasively detecting early signals of multiple different cancers and potentially reducing cancer-related mortality, there is a dearth of prospective clinical data to inform the deployment of MCD assays for cancer screening in the general adult population. In this review we highlight differing technologies that underpin various MCD assays in clinical development, the importance of achieving adequate performance specifications for MCD assays, ongoing clinical studies investigating the utility of MCD assays in cancer screening and detection, and efforts by the NCI's Division of Cancer Prevention (DCP) to establish a network infrastructure that has the capacity to comprehensively address the scientific and logistical challenges of evaluating blood-based MCD approaches and other cancer screening tools.


Asunto(s)
Neoplasias Hematológicas , Neoplasias , Adulto , Humanos , Estudios Prospectivos , Neoplasias/diagnóstico , Neoplasias/prevención & control , Biomarcadores de Tumor/genética , Detección Precoz del Cáncer
14.
Int J Cardiol ; 399: 131668, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38141723

RESUMEN

BACKGROUND AND AIMS: Coronary hemodynamics impact coronary plaque progression and destabilization. The aim of the present study was to establish the association between focal vs. diffuse intracoronary pressure gradients and wall shear stress (WSS) patterns with atherosclerotic plaque composition. METHODS: Prospective, international, single-arm study of patients with chronic coronary syndromes and hemodynamic significant lesions (fractional flow reserve [FFR] ≤ 0.80). Motorized FFR pullback pressure gradient (PPG), optical coherence tomography (OCT), and time-average WSS (TAWSS) and topological shear variation index (TSVI) derived from three-dimensional angiography were obtained. RESULTS: One hundred five vessels (median FFR 0.70 [Interquartile range (IQR) 0.56-0.77]) had combined PPG and WSS analyses. TSVI was correlated with PPG (r = 0.47, [95% Confidence Interval (95% CI) 0.30-0.65], p < 0.001). Vessels with a focal CAD (PPG above the median value of 0.67) had significantly higher TAWSS (14.8 [IQR 8.6-24.3] vs. 7.03 [4.8-11.7] Pa, p < 0.001) and TSVI (163.9 [117.6-249.2] vs. 76.8 [23.1-140.9] m-1, p < 0.001). In the 51 vessels with baseline OCT, TSVI was associated with plaque rupture (OR 1.01 [1.00-1.02], p = 0.024), PPG with the extension of lipids (OR 7.78 [6.19-9.77], p = 0.003), with the presence of thin-cap fibroatheroma (OR 2.85 [1.11-7.83], p = 0.024) and plaque rupture (OR 4.94 [1.82 to 13.47], p = 0.002). CONCLUSIONS: Focal and diffuse coronary artery disease, defined using coronary physiology, are associated with differential WSS profiles. Pullback pressure gradients and WSS profiles are associated with atherosclerotic plaque phenotypes. Focal disease (as identified by high PPG) and high TSVI are associated with high-risk plaque features. CLINICAL TRIAL REGISTRATION: https://clinicaltrials,gov/ct2/show/NCT03782688.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Placa Aterosclerótica , Humanos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Reserva del Flujo Fraccional Miocárdico/fisiología , Hemodinámica , Fenotipo , Placa Aterosclerótica/diagnóstico por imagen , Placa Aterosclerótica/patología , Valor Predictivo de las Pruebas , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...