Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Biosens Bioelectron ; 193: 113531, 2021 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-34333363

RESUMEN

We propose a new platform that can integrate three-dimensional cell culture scaffold and a surface-enhanced Raman spectroscopy (SERS)-based biosensor by stacking them to form a multilayer system, which would allow monitoring of the protein markers secreted from cultured stem cells without periodic cell and/or media collection. The cell culture scaffold supported the proliferation and osteogenic differentiation of adipose-derived mesenchymal stem cells (ADSCs). The SERS capture substrate detected protein markers in combination with SERS tag made with Au-Ag alloy nanoboxes. Incorporating the different Raman reporters into the SERS tag allowed easy identification of target proteins for multiplex assays. The resultant SERS-based immunoassay could detect the pg/mL levels of protein markers without crosstalk and interference. When one ADSC culture scaffold and multiple SERS capture substrates were integrated and incubated in differentiation culture media, our system was sufficiently sensitive to monitor time-dependent secretion of three different osteogenic protein markers from ADSCs during their osteogenic differentiation. Since the sensor and cell culture scaffold can be manipulated independently, various cell and biomarker combinations are possible to obtain relevant information regarding the actual state of the different types of cells.


Asunto(s)
Técnicas Biosensibles , Osteogénesis , Biomarcadores , Técnicas de Cultivo de Célula , Espectrometría Raman , Células Madre
2.
Yonsei Med J ; 54(3): 720-5, 2013 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-23549821

RESUMEN

PURPOSE: The purpose of this study is to evaluate the relationship between the angle formed between the proximal most screw through the locking compression plate-proximal lateral tibia (LCP PLT) and the joint line, and to evaluate if this angle can be used intraoperatively as an assessment tool to determine normal alignment of the tibia in the coronal plane. MATERIALS AND METHODS: There are two parts to this study: in the first part, LCP PLT was applied to 30 cadaveric adult tibia. The angle between the joint line and the proximal most screw was measured and termed as the 'joint screw angle' (JSA). In the second part, 56 proximal tibial fractures treated with LCP PLT were retrospectively studied. Two angles were measured on the radiographs, the medial proximal tibial angle (MPTA) and the JSA. Their relationship was analyzed statistically. RESULTS: The average JSA was 1.16 degrees in the anatomical study. Statistical analysis of the clinical study showed that the normal MPTA had a direct correlation with an acceptable JSA. CONCLUSION: We therefore conclude that the JSA can be used intraoperatively to assess the achievement of a normal coronal axis.


Asunto(s)
Tornillos Óseos , Procedimientos Ortopédicos/métodos , Fracturas de la Tibia/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radiografía , Estudios Retrospectivos , Fracturas de la Tibia/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...