Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 91(1): 014704, 2020 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-32012645

RESUMEN

In this paper, we present noncontact and noninvasive vital signal detection using a microwave reflectometer. Elimination of noise components due to random movement of human subjects has been the biggest issue for microwave measurement. Appropriate filtering, amplitude control of the reflectometer signal, and cross correlation among multiple reflectometers together with new algorithms have enabled motion artifact elimination, signal peak detection, and data processing for various parameters related to heart rate (HR) and heart rate variability (HRV). We focus here on the real time measurements of instantaneous HR and HRV for practical use. The evaluation by microwave reflectometry is completely noninvasive and feasible even through clothing, which is extremely effective for health maintenance in daily life as well as for preventing sudden death related to, for example, coronary heart disease and ventricular arrhythmia.


Asunto(s)
Frecuencia Cardíaca , Microondas , Procesamiento de Señales Asistido por Computador , Femenino , Humanos , Masculino
2.
Rev Sci Instrum ; 85(11): 11D411, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25430174

RESUMEN

We propose a new interferometer system for density profile measurements. This system produces multiple measurement chords by a leaky-wave antenna driven by multiple frequency inputs. The proposed system was validated in laboratory evaluation experiments. We confirmed that the interferometer generates a clear image of a Teflon plate as well as the phase shift corresponding to the plate thickness. In another experiment, we confirmed that quasi-optical mirrors can produce multiple measurement chords; however, the finite spot size of the probe beam degrades the sharpness of the resulting image.

3.
Rev Sci Instrum ; 85(11): 11D805, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25430218

RESUMEN

A new antenna array is proposed in order to improve the sensitivity and complexity of microwave imaging diagnostics systems such as a microwave imaging reflectometry, a microwave imaging interferometer, and an electron cyclotron emission imaging. The antenna array consists of five elements: a horn antenna, a waveguide-to-microstrip line transition, a mixer, a local oscillation (LO) module, and an intermediate frequency amplifier. By using an LO module, the LO optics can be removed, and the supplied LO power to each element can be equalized. We report details of the antenna array and characteristics of a prototype antenna array.

4.
Rev Sci Instrum ; 83(10): 10E305, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23126965

RESUMEN

Three-dimensional (3D) microwave imaging reflectometry has been developed in the large helical device to visualize fluctuating reflection surface which is caused by the density fluctuations. The plasma is illuminated by the probe wave with four frequencies, which correspond to four radial positions. The imaging optics makes the image of cut-off surface onto the 2D (7 × 7 channels) horn antenna mixer arrays. Multi-channel receivers have been also developed using micro-strip-line technology to handle many channels at reasonable cost. This system is first applied to observe the edge harmonic oscillation (EHO), which is an MHD mode with many harmonics that appears in the edge plasma. A narrow structure along field lines is observed during EHO.

5.
Rev Sci Instrum ; 81(10): 10D514, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21033869

RESUMEN

Two dimensional (2D) plasma image analysis is useful to study the improvement of plasma confinement in magnetically confined fusion plasmas. We have constructed a 2D interferometer system with phase imaging method for studying 2D plasma density distribution and its fluctuation measurement in the tandem mirror GAMMA 10. 2D profiles of electron density and its fluctuation have been successfully obtained by using this 2D phase imaging system. We show that 2D plasma density and fluctuation profiles clearly depends on the axial confining potential formation with application of plug electron cyclotron heating in GAMMA 10.

6.
Rev Sci Instrum ; 81(10): 10D915, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21033947

RESUMEN

A simultaneous projection/detection system of four different frequencies for microwave imaging reflectometry (MIR) was developed for three-dimensional observation of electron density fluctuations in the Large Helical Device (LHD). The microwave with four frequency components at 60.410, 61.808, 63.008, and 64.610 GHz is projected in a continuous-wave mode to illuminate the target LHD plasma. A two-dimensional horn-antenna mixer array (2D HMA) receives the reflected wave from the plasma as well as the wave from the local oscillator operating at 55.800 GHz. The first intermediate frequency (IF) signals at 4.610, 6.008, 7.208, and 8.810 GHz were confirmed to be obtained by downconversion of these microwaves using the 2D HMA. Each of these first IF components is filtered from each other and downconverted again for the superheterodyne detection. It was confirmed that both the amplitudes and the phases of the detected signals reflect the fluctuations in LHD plasmas.

7.
Rev Sci Instrum ; 81(10): 10D916, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21033948

RESUMEN

We developed and installed an electron cyclotron emission radiometer for taking measurements of Korea Superconducting Tokamak Advanced Research (KSTAR) plasma. In order to precisely measure the absolute value of electron temperatures, a calibration measurement of the whole radiometer system was performed, which confirmed that the radiometer has an acceptably linear output signal for changes in input temperature. It was also found that the output power level predicted by a theoretical calculation agrees with that obtained by the calibration measurement. We also showed that the system displays acceptable noise-temperature performance around 0.23 eV.

8.
Rev Sci Instrum ; 81(10): 10D919, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21033951

RESUMEN

A combined system of microwave imaging reflectometry and electron cyclotron emission (ECE) imaging has been developed for the Large Helical Device. This system includes a wide-band two-dimensional horn-antenna mixer array (HMA). The HMA consists of horn antennas, waveguides, mixers, and intermediate frequency circuits. The frequency response of the HMA is between 50 and 110 GHz. The ECE signal is selected using a 95 GHz local oscillator and a 93 GHz high-pass filter.

9.
Rev Sci Instrum ; 81(10): 10D922, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21033954

RESUMEN

A new electron cyclotron emission (ECE) diagnostics system was installed for the Second Korea Superconducting Tokamak Advanced Research (KSTAR) campaign. The new ECE system consists of an ECE collecting optics system, an overmode circular corrugated waveguide system, and 48 channel heterodyne radiometer with the frequency range of 110-162 GHz. During the 2 T operation of the KSTAR tokamak, the electron temperatures as well as its radial profiles at the high field side were measured and sawtooth phenomena were also observed. We also discuss the effect of a window on in situ calibration.

10.
Rev Sci Instrum ; 79(10): 10F111, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19044595

RESUMEN

Three key devices of the microwave imaging reflectometry (MIR) are under development in large helical device (LHD). The 2-D mixer array is developed by stacking the one-dimensional array of the planar Yagi-Uda antenna. The new type of the bandpass filter bank is modified to match the requirement of the MIR. The low-cost quadrature demodulator is also developed for the phase detection system. By using the low-price commercial wireless devices, the development cost becomes much lower than the expensive waveguide system. These devices enable the development of 2-D/3-D microwave imaging system for the plasma diagnostics and industrial applications.

11.
Rev Sci Instrum ; 79(5): 056106, 2008 May.
Artículo en Inglés | MEDLINE | ID: mdl-18513099

RESUMEN

We report here on the application of an ultrashort-pulse reflectometer (USPR) to Large Helical Device in National Institute for Fusion Science. An impulse with picosecond pulse width is used as a source in an USPR. Since the bandwidth of a source is inversely related to the pulse width, we can utilize the frequency range of microwave to millimeter-wave by using wide band transmission lines. The density profiles can be reconstructed by collecting time-of-flight signal of each frequency component of an impulse reflected from each cutoff layer. Remote control system using super science information network has been introduced to the present USPR system.

12.
Ther Apher ; 5(1): 46-8, 2001 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-11258610

RESUMEN

In ABO major incompatibility on bone marrow transplantation (BMT), red cells must be removed from collected marrow fluid to prevent hemolysis. We report the concentration of progenitor cells collected using a continuous flow cell separator (Cobe Spectra). The average volume of concentrated bone marrow was 132 +/- 47 ml and that of red cells included was 5.1 +/- 2.4 ml. The red cell removal rate was 97.6%. The recovery rate was 40.6% for total nuclear cells, 77.9% for mononuclear cells, 100% for CD34+ cells, and 93.9% for colony forming unit granulocyte-macrophage. Eighteen patients undergoing allogeneic BMT showed no signs of fever or hemolysis during concentrated marrow fluid transfusion. The recovery rate of progenitor cells was high, indicating sufficient recovery of hemopoiesis. This technique is applicable in ABO-incompatible BMT and in frozen-storage stem cells.


Asunto(s)
Purgación de la Médula Ósea/instrumentación , Neoplasias Hematológicas/terapia , Trasplante de Células Madre Hematopoyéticas/métodos , Sistema del Grupo Sanguíneo ABO , Recuento de Células Sanguíneas , Incompatibilidad de Grupos Sanguíneos , Purgación de la Médula Ósea/métodos , Citometría de Flujo , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...