Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Med Phys ; 49(1): 6-11, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38828066

RESUMEN

Introduction: This study aimed to investigate whether there is a dosimetric difference of implementing single instead of multi-computed tomography (CT) simulation treatment planning for high-dose-rate postoperative gynecological intracavitary brachytherapy (BT). Materials and Methods: Eighty patients were registered in the study. They received three BT fractions of 7 Gy/week (three CTs, three original plans). The organs at risk (OAR), the rectal wall, and the clinical target volume (CTV) were delineated. The delivered doses for the 2cc of OARs (D2cc), 1cc of rectal wall (D1cc), as well as for the 90% and 100% of CTV volume (DCTV90%, DCTV100%) were evaluated. To evaluate the values of the above parameters if the single-CT-simulation method has been chosen, the time of the first treatment plan was corrected for the decay and applied as the second and third CT, retrospectively, creating the next fractions (two revised plans). Results: No statistically significant (P > 0.05) differences were found between the original and revised plans for the OARs and CTV. However, for the single-CT-simulation method, it was noted that the dose constraints for the total rectal dose were exceeded in some cases (36.3%). Conclusion: The fact that rectal dose constraints were exceeded in 1/3 of patients with the single-CT-simulation method is dosimetrically significant.

2.
J Appl Clin Med Phys ; 24(9): e14051, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37344987

RESUMEN

PURPOSE: This study aimed to assess the accuracy and dosimetric impact of the Acuros XB (AXB) algorithm compared to the Anisotropic Analytical Algorithm (AAA) in two situations. First, simple phantom geometries were set and analyzed; moreover, volumetric modulated arc therapy (VMAT) clinical plans for Head & Neck and lung cases were calculated and compared. METHODS: First, a phantom study was performed to compare the algorithms with radiochromic EBT3 film doses using one PMMA slab phantom and two others containing foam or air gap. Subsequently, a clinical study was conducted, including 20 Head & Neck and 15 lung cases irradiated with the VMAT technique. The treatment plans calculated by AXB and AAA were evaluated in terms of planning target volume (PTV) coverage (V95% ), dose received by relevant organs at risk (OARs), and the impact of using AXB with a grid size of 1 mm. Finally, patient-specific quality assurance (PSQA) was performed and compared for 17 treatment plans. RESULTS: Phantom dose calculations showed a better agreement of AXB with the film measurements. In the clinical study, AXB plans exhibited lower Conformity Index and PTV V95% , higher maximum PTV dose, and lower mean and minimum PTV doses for all anatomical sites. The most notable differences were detected in regions of intense heterogeneity. AXB predicted lower doses for the OARs, while the calculation time with a grid size of 1 mm was remarkably higher. Regarding PSQA, although AAA was found to exhibit slightly higher gamma passing rates, the difference did not affect the AXB treatment plan quality. CONCLUSIONS: AXB demonstrated higher accuracy than AAA in dose calculations of both phantom and clinical conditions, specifically in interface regions, making it suitable for sites with large heterogeneities. Hence, such dosimetric differences between the two algorithms should always be considered in clinical practice.


Asunto(s)
Radioterapia de Intensidad Modulada , Humanos , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radiometría/métodos , Algoritmos
3.
Biomedicines ; 11(3)2023 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-36979740

RESUMEN

The aim of this study was to evaluate knowledge-based treatment planning (KBP) models in terms of their dosimetry and deliverability and to investigate their clinical benefits. Three H&N KBP models were built utilizing RapidPlan™, based on the dose prescription, which is given according to the planning target volume (PTV). The training set for each model consisted of 43 clinically acceptable volumetric modulated arc therapy (VMAT) plans. Model quality was assessed and compared to the delivered treatment plans using the homogeneity index (HI), conformity index (CI), structure dose difference (PTV, organ at risk-OAR), monitor units, MU factor, and complexity index. Model deliverability was assessed through a patient-specific quality assurance (PSQA) gamma index-based analysis. The dosimetric assessment showed better OAR sparing for the RapidPlan™ plans and for the low- and high-risk PTV, and the HI, and CI were comparable between the clinical and RapidPlan™ plans, while for the intermediate-risk PTV, CI was better for clinical plans. The 2D gamma passing rates for RapidPlan™ plans were similar or better than the clinical ones using the 3%/3 mm gamma-index criterion. Monitor units, the MU factors, and complexity indices were found to be comparable between RapidPlan™ and the clinical plans. Knowledge-based treatment plans can be safely adapted into clinical routines, providing improved plan quality in a time efficient way while minimizing user variability.

4.
Phys Med ; 107: 102536, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36842261

RESUMEN

PURPOSE: To establish automated quality assurance (QA) procedures for the kilovoltage (kV) and the Megavoltage (MV) imagers of two linear accelerators (LINACS) using a commercial software. METHODS: SNC Machine™ phantoms and software were used and the baseline values, tolerance and action levels for various image quality parameters were defined. Scaling, spatial resolution, contrast, uniformity and noise were considered, explored and evaluated utilizing the appropriate phantoms and the accompanying software. kV and MV planar radiographic images, for 6MV and 10MV beams were obtained for each LINAC. For both kV and MV QA tasks, the baseline values for spatial resolution, contrast, uniformity and noise were defined. RESULTS: Subsequent measurements performed were highly reproducible and within tolerance and action levels, while noise showed variations. The calculated tolerance and action levels for noise were looser compared to the other image quality metrics. CONCLUSIONS: An automated QA workflow of the kV and MV planar radiographic mode of LINAC imagers' was established and appears to be time effective.


Asunto(s)
Aceleradores de Partículas , Programas Informáticos , Fantasmas de Imagen , Automatización
5.
Front Public Health ; 9: 701878, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34368064

RESUMEN

The effect of the reportedly low ionizing radiation doses, such as those very often delivered to patients in interventional cardiology, remains ambiguous. As interventional cardiac procedures may have a significant impact on total collective effective dose, there are radiation protection concerns for patients and physicians regarding potential late health effects. Given that very low doses (<100 mSv) are expected to be delivered during these procedures, the purpose of this study was to assess the potency and suitability of current genotoxicity biomarkers to detect and quantitate biological effects essential for risk estimation in interventional cardiology. Specifically, the biomarkers γ-H2AX foci, dicentric chromosomes, and micronuclei, which underpin radiation-induced DNA damage, were studied in blood lymphocytes of 25 adult patients before and after interventional cardiac procedures. Even though the mean values of all patients as a group for all three endpoints tested show increased yields relative to baseline following medical exposure, our results demonstrate that only the γ-H2AX biomarker enables detection of statistically significant differences at the individual level (p < 0.001) for almost all patients (91%). Furthermore, 24 h after exposure, residual γ-H2AX foci were still detectable in irradiated lymphocytes. Their decline was found to vary significantly among the individuals and the repair kinetics of γ-H2AX foci was found to range from 25 to 95.6% of their maximum values obtained.


Asunto(s)
Cardiología , Traumatismos por Radiación , Adulto , Biomarcadores , Daño del ADN , Relación Dosis-Respuesta en la Radiación , Histonas/genética , Humanos
6.
Ann Nucl Med ; 26(3): 228-33, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22222778

RESUMEN

AIM: The precise localization of bone marrow stem cells (SCs) into the necrotic tissue after intracoronary infusion (ICI) may be important for the therapeutic outcome. This study aims to examine the correlation between Tl-201 and Tc-99m-hexa-methyl-propylene-amine-oxime (HMPAO) images. METHODS: Thirteen patients, aged 36-62 years, with an old, nonviable, anterior myocardial infarction (MI) and reduced myocardial contractility (LVEF <40%), underwent ICI of selected CD133(+) and CD133(neg)CD34(+) SCs. One hour after the ICI, SPECT imaging with Tc-99m-HMPAO was performed in all patients and the acquired images were compared with the images obtained during the initial imaging for demonstration of viability (myocardial perfusion imaging with pharmacologic stress and Tl-201). Furthermore, two fused bull's eye images of Tc-99m-HMPAO and Tl-201 rest reinjection were created in six patients and regions of interest were set on Tl-201 and Tc-99m-HMPAO bull's eye images. RESULTS: The comparison of the two sets of images revealed an intense accumulation of the SCs in the infarcted area with absence of viability as assessed by Tl-201 reinjection images. In the subset of patients in whom fused bull's eye images were produced, the comparison demonstrated that the percentage of the infarcted area with SCs' adherence was 83.2 ± 17%. CONCLUSIONS: Tl-201 images are complementary with the respective Tc-99m-HMPAO ones, revealing a precise localization of SCs in the infarcted area. Tc-99m-HMPAO labeling of SCs is a reliable method for cell monitoring after ICI in nonviable myocardium after an anterior MI.


Asunto(s)
Células de la Médula Ósea/patología , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/patología , Cintigrafía/métodos , Células Madre/patología , Exametazima de Tecnecio Tc 99m , Radioisótopos de Talio , Adulto , Adhesión Celular , Femenino , Humanos , Masculino , Persona de Mediana Edad , Miocardio/patología , Necrosis , Estudios Retrospectivos , Células Madre/diagnóstico por imagen , Factores de Tiempo
7.
Stem Cells ; 24(10): 2279-83, 2006 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16794269

RESUMEN

Central issues in intracoronary infusion (ICI) of bone marrow (BM)-cells to damaged myocardium for improving cardiac function are the cell number that is feasible and safe to be administrated as well as the retention of cells in the target area. Our study addressed these issues in eight patients with chronic ischemic cardiomyopathy undergoing ICI of selected BM-progenitors. We could immunomagnetically isolate 0.8 +/- 0.32 x 10(7) CD133(+) cells and 0.75 +/- 0.24 x 10(7) CD133(-)CD34(+) cells from 310 +/- 40 ml BM. After labeling these cells with (99m)Tc-hexamethylpropylenamineoxime, they were infused into the infarct-related artery without any complication. Scintigraphic images 1 (eight patients) and 24 hours (four patients) after ICI revealed an uptake of 9.2% +/- 3.6 and 6.8% +/- 2.4 of the total infused radioactivity in the infarcted area of the heart, respectively; the remaining activity was distributed mainly to liver and spleen. We conclude that through ICI of CD133(+) and CD133(-)CD34(+) BM-progenitors a significant number of them are preferentially attracted to and retained in the chronic ischemic myocardium.


Asunto(s)
Antígenos CD34/inmunología , Antígenos CD/inmunología , Células de la Médula Ósea/citología , Glicoproteínas/inmunología , Isquemia Miocárdica/cirugía , Péptidos/inmunología , Células Madre/citología , Antígeno AC133 , Adulto , Células de la Médula Ósea/inmunología , Trasplante de Médula Ósea/métodos , Enfermedad Crónica , Citometría de Flujo , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/patología , Miocardio/inmunología , Miocardio/patología , Células Madre/inmunología , Trasplante Autólogo
8.
J Interv Cardiol ; 19(3): 237-44, 2006 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16724966

RESUMEN

AIM: To explore the factors that may influence the radiation dose imparted to the patient in PCI, and investigate whether the use of the latest digital X-ray system based on FP detector technology can have an impact on dose. MATERIALS AND METHOD: Demographic and clinical data such as number of lesions treated, number of stents placed, grade of tortuosity, and stage of occlusion, as well as use of double wire and double balloon technique, ostial stenting or bifurcation stenting, and presence of major complications were recorded, together with radiation parameters. RESULTS: The factors that increased patient radiation dose were (1) patient gender, as men exhibited higher doses than women; (2) complex lesion; (3) increasing number of stents; (4) position of stent; (5) grade of tortuosity; and (6) stage of occlusion. The FP digital system appeared to be settled in a lower-dose rate for fluoroscopy (a factor of 6) and higher for dose per frame in cine (a factor of 3) in comparison with the image intensifier (II) system. There was a marked reduction of DAP when the FP technology was introduced. CONCLUSION: More extensive studies should be performed in the future so as to further investigate the influence of the FP detector in IC.


Asunto(s)
Angioplastia Coronaria con Balón/métodos , Enfermedad de la Arteria Coronaria/radioterapia , Dosis de Radiación , Enfermedad de la Arteria Coronaria/terapia , Femenino , Fluoroscopía , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Medición de Riesgo , Factores de Riesgo
9.
Radiat Prot Dosimetry ; 111(3): 297-304, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-15266080

RESUMEN

The purpose of the study was to evaluate the dose performance of a flat-panel (FP) and an image intensifier (II) charge coupled device (CCD) digital fluoroscopy X-ray systems newly installed in an Interventional Cardiology (IC) department. Filter entrance dose rate, detector dose rate (during fluoroscopy) and filter entrance dose per image were measured at 70 cm from the focus using 2 mm copper sheets to mimic normal size patient. Image quality was also evaluated. The patient dose survey included 277 patients, which had either a Coronary Angiography (CA) or a Percutaneous Transluminal Coronary Angioplasty (PTCA). Dose area product (DAP), fluoroscopy time (T) and total number of frames (F) values were also collected. The results showed that both systems performed within international recommendations with the exception of higher cine radiation doses, stressing the fact that neither specific protocols of measurement nor reference values for digital equipment were provided by the official bodies.


Asunto(s)
Cardiología/instrumentación , Análisis de Falla de Equipo/métodos , Seguridad de Equipos/métodos , Fluoroscopía/instrumentación , Intensificación de Imagen Radiográfica/instrumentación , Radiografía Intervencional/instrumentación , Radiometría/métodos , Pantallas Intensificadoras de Rayos X , Dosis de Radiación , Protección Radiológica/métodos , Medición de Riesgo/métodos , Factores de Riesgo , Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...