Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
J Vasc Interv Radiol ; 34(8): 1364-1371, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37100199

RESUMEN

PURPOSE: To evaluate recovery of platelet count after transjugular intrahepatic portosystemic shunt (TIPS) creation and patient factors predicting platelet recovery after TIPS creation. MATERIALS AND METHODS: Adults with cirrhosis who underwent TIPS creation at 9 U.S. hospitals from 2010 to 2015 were included in this retrospective analysis. Change in platelets from before TIPS to 4 months after TIPS creation was characterized. Logistic regression was used to assess factors associated with top quartile percentage platelet increase after TIPS. Subgroup analyses were performed among patients with a pre-TIPS platelet count of ≤50 ×109/L. RESULTS: A total of 601 patients were included. The median absolute change in platelets was 1 × 109/L (-26 × 109/L to 25 × 109/L). Patients with top quartile percent platelet increase experienced ≥32% platelet increase. In multivariable analysis, pre-TIPS platelet counts (odds ratio [OR], 0.97 per 109/L; 95% CI, 0.97-0.98), age (OR, 1.24 per 5 years; 95% CI, 1.10-1.39), and pre-TIPS model for end-stage liver disease (MELD) scores (OR, 1.06 per point; 95% CI, 1.02-1.09) were associated with top quartile (≥32%) platelet increase. Ninety-four (16%) patients had a platelet count of ≤50 × 109/L before TIPS. The median absolute platelet change was 14 × 109/L (2 × 109/L to 34 × 109/L). Fifty-four percent of patients in this subgroup were in the top quartile for platelet increase. In multivariable logistic regression, age (OR, 1.50 per 5 years; 95% CI, 1.11-2.02) was the only factor associated with top quartile platelet increase in this subgroup. CONCLUSIONS: TIPS creation did not result in significant platelet increase, except among patients with a platelet count of ≤50 × 109/L before TIPS. Lower pre-TIPS platelet counts, older age, and higher pre-TIPS MELD scores were associated with top quartile (≥32%) platelet increase in the entire cohort, whereas only older age was associated with this outcome in the patient subset with a pre-TIPS platelet count of ≤50 × 109/L.


Asunto(s)
Enfermedad Hepática en Estado Terminal , Derivación Portosistémica Intrahepática Transyugular , Adulto , Humanos , Preescolar , Recuento de Plaquetas , Estudios Retrospectivos , Derivación Portosistémica Intrahepática Transyugular/efectos adversos , Índice de Severidad de la Enfermedad , Cirrosis Hepática/diagnóstico , Cirrosis Hepática/cirugía , Cirrosis Hepática/complicaciones , Resultado del Tratamiento
2.
Clin Imaging ; 97: 72-77, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36907042

RESUMEN

PURPOSE: We sought to identify which aspects of the referring clinician experience are most strongly correlated with overall satisfaction, and hence of greatest relevant importance to referring clinicians. METHODS: A survey instrument assessing referring clinician satisfaction throughout 11 domains of the radiology process map was distributed 2720 clinicians. The survey contained sections assessing each process map domain, with each section including a question about satisfaction overall in that domain and multiple more granular questions. The final question on the survey was overall satisfaction with the department. Univariate logistic regression and multivariate logistic regression were performed to assess the association between individual survey questions and overall satisfaction with the department. RESULTS: 729 referring clinicians (27%) completed the survey. Using univariate logistic regression nearly every question was associated with overall satisfaction. Amongst the 11 domains of the radiology process map multivariate logistic regression identified the following as mostly strongly associated with overall satisfaction: results/reporting overall (odds ratio 4.71; 95% confidence interval 2.15-10.23), section with which work most closely overall (3.39; 1.28-8.64), and inpatient radiology overall (2.39; 1.08-5.08). Other survey questions associated with overall satisfaction on multivariate logistic regression were attending radiologist interactions (odds ratio 3.71; 95% confidence interval 1.54-8.69), timeliness of inpatient radiology results (2.91; 1.01-8.09), technologist interactions (2.15; 0.99-4.40), appointment availability for urgent outpatient studies (2.01; 1.08-3.64), and guidance for selecting correct imaging study (1.88; 1.04-3.34). CONCLUSION: Referring clinicians value most the accuracy of the radiology report and their interactions with attending radiologists, particularly within the section they work most closely.


Asunto(s)
Radiología , Humanos , Radiología/métodos , Radiografía , Diagnóstico por Imagen , Encuestas y Cuestionarios , Radiólogos
3.
Clin Gastroenterol Hepatol ; 20(8): 1636-1662.e36, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-34274511

RESUMEN

Complications of portal hypertension, including ascites, gastrointestinal bleeding, hepatic hydrothorax, and hepatic encephalopathy, are associated with significant morbidity and mortality. Despite few high-quality randomized controlled trials to guide therapeutic decisions, transjugular intrahepatic portosystemic shunt (TIPS) creation has emerged as a crucial therapeutic option to treat complications of portal hypertension. In North America, the decision to perform TIPS involves gastroenterologists, hepatologists, and interventional radiologists, but TIPS creation is performed by interventional radiologists. This is in contrast to other parts of the world where TIPS creation is performed primarily by hepatologists. Thus, the successful use of TIPS in North America is dependent on a multidisciplinary approach and technical expertise, so as to optimize outcomes. Recently, new procedural techniques, TIPS stent technology, and indications for TIPS have emerged. As a result, practices and outcomes vary greatly across institutions and significant knowledge gaps exist. In this consensus statement, the Advancing Liver Therapeutic Approaches group critically reviews the application of TIPS in the management of portal hypertension. Advancing Liver Therapeutic Approaches convened a multidisciplinary group of North American experts from hepatology, interventional radiology, transplant surgery, nephrology, cardiology, pulmonology, and hematology to critically review existing literature and develop practice-based recommendations for the use of TIPS in patients with any cause of portal hypertension in terms of candidate selection, procedural best practices and, post-TIPS management; and to develop areas of consensus for TIPS indications and the prevention of complications. Finally, future research directions are identified related to TIPS for the management of portal hypertension.


Asunto(s)
Várices Esofágicas y Gástricas , Hipertensión Portal , Derivación Portosistémica Intrahepática Transyugular , Ascitis/etiología , Várices Esofágicas y Gástricas/complicaciones , Hemorragia Gastrointestinal/complicaciones , Hemorragia Gastrointestinal/cirugía , Humanos , Hipertensión Portal/complicaciones , Hipertensión Portal/cirugía , Derivación Portosistémica Intrahepática Transyugular/efectos adversos , Resultado del Tratamiento
5.
Cardiovasc Intervent Radiol ; 44(1): 141-149, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32895782

RESUMEN

PURPOSE: To determine the safety and feasibility of pancreatic retrograde venous infusion (PRVI) utilizing a microvalvular infusion system (MVI) to deliver ethiodized oil (lipiodol) by means of the Pressure-Enabled Drug Delivery (PEDD) approach. METHODS: Utilizing transhepatic access, mapping of the pancreatic body and head venous anatomy was performed in 10 swine. PEDD was performed by cannulation of veins in the head (n = 4) and body (n = 10) of the pancreas with a MVI (Surefire® Infusion System (SIS), Surefire Medical, Inc (DBA TriSalus™ Life Sciences)) followed by infusion with lipiodol. Sets of animals were killed either immediately (n = 8) or at 4 days post-PRVI (n = 2). All pancreata were harvested and studied with micro-CT and histology. We also performed three-dimensional volumetric/multiplanar imaging to assess the vascular distribution of lipiodol within the glands. RESULTS: A total of 14 pancreatic veins were successfully infused with an average of 1.7 (0.5-2.0) mL of lipiodol. No notable change in serum chemistries was seen at 4 days. The signal-to-noise ratio (SNR) of lipiodol deposition was statistically increased both within the organ in target relative to non-target pancreatic tissue and compared to extra pancreatic tissue (p < 0.05). Histological evaluation demonstrated no evidence of pancreatic edema or ischemia. CONCLUSIONS: PEDD using the RVI approach for targeted pancreatic infusions is technically feasible and did not result in organ damage in this pilot animal study.


Asunto(s)
Sistemas de Liberación de Medicamentos , Aceite Etiodizado/administración & dosificación , Páncreas/efectos de los fármacos , Animales , Antineoplásicos/administración & dosificación , Infusiones Intravenosas , Modelos Animales , Presión , Porcinos
10.
Emerg Radiol ; 27(2): 115-126, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31925592

RESUMEN

Intravenous (IV) contrast material is used extensively for CT and MRI scans done in emergency departments (ED). Its use is essential to make many critical diagnoses in ED patients. While adverse reactions can occur, newer research has added to our knowledge of IV contrast media tolerance and safety leading to improved and more liberal guidelines for intravenous contrast use. The updated information described in this review article indicates how intravenous contrast can be used safely in more patients, more expeditiously and with fewer precautions than with prior guidelines. This review article explains the basis for the new recommendations for intravenous contrast material use and describes indicated precautions and preparations to avoid adverse reactions for iodinated agents used for CT and gadolinium agents for MRI.


Asunto(s)
Medios de Contraste/administración & dosificación , Servicio de Urgencia en Hospital , Imagen por Resonancia Magnética , Guías de Práctica Clínica como Asunto , Tomografía Computarizada por Rayos X , Medios de Contraste/efectos adversos , Hipersensibilidad a las Drogas/etiología , Hipersensibilidad a las Drogas/prevención & control , Gadolinio/administración & dosificación , Gadolinio/efectos adversos , Humanos , Inyecciones Intravenosas , Factores de Riesgo , Administración de la Seguridad
11.
J Hepatocell Carcinoma ; 6: 93-103, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31355158

RESUMEN

Purpose: To determine whether chemoembolization using drug-eluting beads (DEB-TACE) is safe and effective for liver transplantation candidates with liver-limited hepatocellular carcinoma (HCC) without vascular invasion and baseline hepatic dysfunction. Materials and methods: Seventeen adult liver transplantation candidates (median age 66 years, range 58-73 years; 13 men) with HCC were treated with DEB-TACE as a part of Stage 1 of a prospective single-institution Phase II trial. All patients had marginal hepatic reserve based on at least one of the following criteria: ascites (n=14), bilirubin between 3 and 6 mg/dL (n=5), AST 5-10 times upper normal limit (n=1), INR between 1.6 and 2.5 (n=4), portal vein thrombosis (n=2), and/or portosystemic shunt (n=2). Primary study objectives were safety and best observed radiographic response. Results: Thirty-seven DEB-TACE procedures were performed. Objective response rate and disease control rate were 63% and 88%, respectively. HCC progression was observed in 12 patients. Median time to progression was 5.6 months (range 0.9-13.6 months). Within 1 month following DEB-TACE, 13 patients (76%) developed grade 3 or 4 AE attributable to the procedure. Four patients (all within Milan Criteria) were transplanted (2.7-6.9 months after DEB-TACE), and 12 patients died (1.8-32 months after DEB-TACE). All deaths were due to liver failure that was either unrelated to HCC (n=5), in the setting of metastatic HCC (n=5), or in the setting of locally advanced HCC (n=2). Mortality rate at 1 month was 0%. Conclusions: DEB-TACE achieves tumor responses but carries a high risk of hepatotoxicity for liver transplant candidates with HCC and marginal hepatic reserve.

12.
J Vasc Interv Radiol ; 30(7): 1043-1047, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30772167

RESUMEN

PURPOSE: To evaluate efficacy and safety of transjugular liver biopsy (TJLB) via the left hepatic vein in patients with left lobe-only liver transplants (LLOTs). MATERIALS AND METHODS: Retrospective review revealed 43 TJLBs performed in 26 patients with LLOTs (mean age 51.3 y; range, 18-73 y) between January 2009 and June 2016 at a single institution. A comparison group of 44 randomly selected TJLBs performed in 37 orthotopic whole liver transplant (OWLT) recipients (mean age 57.6 y; range, 35-74 y) during the same time period was evaluated. Patient demographics, type and age of transplant, technical success, adequacy of samples, number of portal tracts obtained, pathologic diagnosis, and complication rate were reviewed. RESULTS: Technical success was achieved in 98% (42/43) of LLOT procedures. TJLB failed in 1 patient with LLOT, in whom no patent hepatic veins were identified. Technical success was achieved in 100% (44/44) in the OWLT group. Mean (SD) number of needle passes was 4.12 (1.25) in the LLOT group vs 3.95 (1.28) in the OWLT group (P = .54). Mean (SD) specimen length was 1.16 (0.75) cm in the LLOT group vs 1.19 (0.58) cm in the OWLT group (P = .78). Mean (SD) number of portal tracts obtained in the LLOT group was 10.7 (5.26) vs 12.3 (4.68) in the OWLT group (P = .17). No major complications were observed in either group. CONCLUSIONS: TJLB in adult patients with LLOTs appears safe and feasible, with favorable rates of technical success and adequacy of sampling.


Asunto(s)
Biopsia con Aguja/métodos , Cateterismo Venoso Central/métodos , Venas Hepáticas , Biopsia Guiada por Imagen/métodos , Venas Yugulares , Trasplante de Hígado , Complicaciones Posoperatorias/patología , Adolescente , Adulto , Anciano , Angiografía de Substracción Digital , Biopsia con Aguja/efectos adversos , Cateterismo Venoso Central/efectos adversos , Femenino , Venas Hepáticas/diagnóstico por imagen , Humanos , Biopsia Guiada por Imagen/efectos adversos , Venas Yugulares/diagnóstico por imagen , Trasplante de Hígado/efectos adversos , Masculino , Persona de Mediana Edad , Flebografía , Complicaciones Posoperatorias/etiología , Valor Predictivo de las Pruebas , Radiografía Intervencional , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Adulto Joven
13.
J Vasc Interv Radiol ; 29(9): 1248-1253, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-30061059

RESUMEN

PURPOSE: To assess the effectiveness of disposable radiation-absorbing surgical drapes on operator radiation dose during transjugular liver biopsy (TJLB). MATERIALS AND METHODS: This dual-arm prospective, randomized study was conducted between May 2017 and January 2018 at a single institution. TJLB procedures (N = 62; patient age range, 19-80 y) were assigned at a 1:1 ratio to the use of radiation-absorbing surgical drapes or standard surgical draping. The primary outcome was cumulative radiation equivalent dose incident on the operator, as determined by an electronic personal dosimeter worn at the chest during each procedure. Cumulative kerma-area product (KAP), total fluoroscopy time, and total number of exposures used during each liver biopsy procedure were also determined. RESULTS: Mean radiation dose incident on the operator decreased by 56% with the use of radiation-absorbing drapes (37 µSv ± 35; range, 4-183 µSv) compared with standard draping (84 µSv ± 58; range, 11-220 µSv). Radiation incident on the patient was similar between groups, with no significant differences in mean KAP, total fluoroscopy time, and number of exposures acquired during the procedures. CONCLUSIONS: Use of disposable radiation-absorbing drapes reduces scatter radiation to interventionalists performing TJLB.


Asunto(s)
Biopsia Guiada por Imagen/instrumentación , Hepatopatías/diagnóstico por imagen , Exposición Profesional/prevención & control , Salud Laboral , Exposición a la Radiación/prevención & control , Protección Radiológica/instrumentación , Radiografía Intervencional/instrumentación , Radiólogos , Paños Quirúrgicos , Adulto , Anciano , Anciano de 80 o más Años , Equipos Desechables , Femenino , Humanos , Biopsia Guiada por Imagen/efectos adversos , Hepatopatías/patología , Masculino , Persona de Mediana Edad , Exposición Profesional/efectos adversos , Proyectos Piloto , Estudios Prospectivos , Factores Protectores , Dosis de Radiación , Dosímetros de Radiación , Exposición a la Radiación/efectos adversos , Radiografía Intervencional/efectos adversos , Factores de Riesgo , San Francisco , Dispersión de Radiación , Adulto Joven
14.
J Vasc Interv Radiol ; 28(8): 1129-1135.e1, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28457758

RESUMEN

PURPOSE: To assess radiation dose reduction during uterine fibroid embolization (UFE) using an optimized angiographic processing and acquisition platform. MATERIALS AND METHODS: Radiation dose data for 70 women (mean age, 46 y; range, 34-67 y) who underwent UFE were retrospectively analyzed. Twenty-one patients underwent UFE using the baseline fluoroscopic and angiographic image acquisition platform, and 49 underwent UFE after implementing an optimized imaging platform in otherwise identical angiography suites. Cumulative kerma-area product (CKAP), cumulative air kerma (CAK), total fluoroscopy time, and image exposure number were collected for each procedure. Image quality was assessed by 3 interventional radiologists blinded to the platform used for image acquisition and processing. RESULTS: Patients undergoing UFE using the new x-ray fluoroscopy platform had significantly lower CKAP and CAK indicators than patients for whom baseline settings were used. Mean CKAP decreased by 60% from 438.5 Gy · cm2 (range, 180.3-1,081.1 Gy · cm2) to 175.2 Gy · cm2 (range, 47.1-757.0 Gy · cm2; P < .0001). Mean CAK decreased by 45% from 2,034.2 mGy (range, 699.3-5,056.0 mGy) to 1,109.8 mGy (range, 256.6-4,513.6 mGy; P = .001). No degradation of image quality was identified through qualitative evaluation. CONCLUSIONS: Significant reduction in patient radiation dose indicators can be achieved with use of an optimized image acquisition and processing platform.


Asunto(s)
Embolización Terapéutica/métodos , Leiomioma/diagnóstico por imagen , Leiomioma/terapia , Protección Radiológica/métodos , Radiografía Intervencional , Neoplasias Uterinas/diagnóstico por imagen , Neoplasias Uterinas/terapia , Adulto , Anciano , Angiografía de Substracción Digital , Femenino , Fluoroscopía , Humanos , Persona de Mediana Edad , Dosis de Radiación , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
15.
J Vasc Interv Radiol ; 27(11): 1698-1704, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27397617

RESUMEN

PURPOSE: To assess safety and efficacy of doxorubicin drug-eluting embolic (DEE) transarterial chemoembolization of hepatocellular carcinoma (HCC) by extrahepatic collateral arteries. MATERIALS AND METHODS: Records of 177 patients with HCC who underwent 338 consecutive DEE chemoembolization procedures from 2011 to 2014 were retrospectively reviewed. A subgroup of 16 patients (13 men, 3 women, median age 66 y) underwent 24 procedures for 17 HCCs via extrahepatic arteries and was included in the study. Median tumor size was 3.1 cm (range, 1.0-10.3 cm). Extrahepatic collaterals included right inferior phrenic (19 procedures; 12 patients), adrenal (4 procedures; 3 patients), and cystic arteries (2 procedures; 2 patients). Radiographic response was assessed by Modified Response Evaluation Criteria in Solid Tumors criteria. Complications were defined by National Cancer Institute Common Terminology Criteria for Adverse Events. RESULTS: DEE chemoembolization achieved stable disease in 6 (35.3%), partial response in 6 (35.3%), and complete response in 4 (23.5%) HCCs. Disease progression was ultimately observed in 8 tumors (47.1%), with mean time to progression of 8.3 months after chemoembolization (range, 2-13 mo). Three minor and 5 major complications occurred in 8 patients; 2 minor complications were rash in vascular distribution after right inferior phrenic artery DEE chemoembolization. The 5 major complications were transient hepatotoxicity that resolved within 4-80 days; 1 was accompanied by pleural effusion requiring hospitalization. A mean 13.4 months after DEE chemoembolization, 67% of transplant candidates proceeded to liver transplant. CONCLUSIONS: DEE transarterial chemoembolization via extrahepatic collaterals was effective and facilitated bridging to transplant. It was generally well tolerated; transient hepatotoxicity was the most common major complication.


Asunto(s)
Antibióticos Antineoplásicos/administración & dosificación , Carcinoma Hepatocelular/irrigación sanguínea , Carcinoma Hepatocelular/terapia , Quimioembolización Terapéutica/métodos , Circulación Colateral , Doxorrubicina/administración & dosificación , Circulación Hepática , Neoplasias Hepáticas/irrigación sanguínea , Neoplasias Hepáticas/terapia , Anciano , Anciano de 80 o más Años , Angiografía de Substracción Digital , Antibióticos Antineoplásicos/efectos adversos , Carcinoma Hepatocelular/diagnóstico por imagen , Quimioembolización Terapéutica/efectos adversos , Angiografía por Tomografía Computarizada , Progresión de la Enfermedad , Doxorrubicina/efectos adversos , Femenino , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Trasplante de Hígado , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
16.
J Gastrointest Oncol ; 7(6): 860-874, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28078110

RESUMEN

BACKGROUND: This prospective pilot single-institution study was undertaken to document the feasibility, safety, and efficacy of radioembolization of liver-dominant metastatic gastrointestinal cancer using 90Y glass microspheres. METHODS: Between June 2010 and October 2013, 42 adult patients (26 men, 16 women; median age 60 years) with metastatic chemotherapy-refractory unresectable colorectal (n=21), neuroendocrine (n=11), intrahepatic bile duct (n=7), pancreas (n=2), and esophageal (n=1) carcinomas underwent 60 lobar or segmental administrations of 90Y glass microspheres. Data regarding clinical and laboratory adverse events (AE) were collected prospectively for up to 5.5 years after radioembolization. Radiographic responses were evaluated using Response Evaluation Criteria in Solid Tumors (RECIST), version 1.1. Time to maximum response, response duration, progression-free survival (PFS) (hepatic and extrahepatic), and overall survival (OS) were measured. RESULTS: Median target dose and activity were 109.4 Gy and 2.6 GBq per treatment session, respectively. Majority of clinical AE were grade 1 or 2 in severity. Patients with colorectal cancer had hepatic objective response rate (ORR) of 25% and a hepatic disease control rate (DCR) of 80%. Median PFS and OS were 1.0 and 4.4 months, respectively. Patients with neuroendocrine tumors (NET) had hepatic ORR and DCR of 73% and 100%, respectively. Median PFS was 8.9 months for this cohort. DCR and median PFS and OS for patients with cholangiocarcinoma were 86%, 1.1 months, and 6.7 months, respectively. CONCLUSIONS: 90Y glass microspheres device has a favorable safety profile, and achieved prolonged disease control of hepatic tumor burden in a subset of patients, including all patients enrolled in the neuroendocrine cohort.

17.
Clin Imaging ; 39(6): 1128-9, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26253773

RESUMEN

Inferior vena cava (IVC) filter placement is indicated for patients with pulmonary embolism and/or deep venous thrombosis when anticoagulation therapy is contraindicated. IVC filter placement, however, is not without complications. In this case, we noted crossing of the filter struts immediately after deployment of the ALN IVC filter (ALN Implants Chirurgicaux Ghisonaccia, France). The filter was then successfully removed.


Asunto(s)
Falla de Prótesis , Filtros de Vena Cava , Vena Cava Inferior/cirugía , Trombosis de la Vena/cirugía , Anciano , Femenino , Humanos , Trombosis de la Vena/complicaciones
18.
J Vasc Interv Radiol ; 26(9): 1331-8, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26212556

RESUMEN

PURPOSE: To evaluate radiation dose reduction in patients undergoing transarterial chemoembolization with the use of a new image acquisition and processing platform. MATERIALS AND METHODS: Radiation-dose data were obtained from 176 consecutive chemoembolization procedures in 135 patients performed in a single angiography suite. From January 2013 through October 2013, 85 procedures were performed by using our institution's standard fluoroscopic settings. After upgrading the x-ray fluoroscopy system with an image acquisition and processing platform designed to reduce image noise and reduce skin entrance dose, 91 chemoembolization procedures were performed from November 2013 through December 2014. Cumulative dose-area product (CDAP), cumulative air kerma (CAK), and total fluoroscopy time were recorded for each procedure. Image quality was assessed by three interventional radiologists blinded to the x-ray acquisition platform used. RESULTS: Patient radiation dose indicators were significantly lower for chemoembolization procedures performed with the novel imaging platform. Mean CDAP decreased from 3,033.2 dGy·cm(2) (range, 600.3-9,404.1 dGy·cm(2)) to 1,640.1 dGy·cm(2) (range, 278.6-6,779.9 dGy·cm(2); 45.9% reduction; P < .00001). Mean CAK decreased from 1,445.4 mGy (range, 303.6-5,233.7 mGy) to 971.7 mGy (range, 144.2-3,512.0 mGy; 32.8% reduction; P < .0001). A 20.3% increase in mean total fluoroscopy time was noted after upgrading the imaging platform, but blinded analysis of the image quality revealed no significant degradation. CONCLUSIONS: Although a small increase in fluoroscopy time was observed, a significant reduction in patient radiation dose was achieved by using the optimized imaging platform, without image quality degradation.


Asunto(s)
Angiografía/instrumentación , Quimioembolización Terapéutica/instrumentación , Fluoroscopía/instrumentación , Dosis de Radiación , Protección Radiológica/instrumentación , Radiografía Intervencional/instrumentación , Adulto , Anciano , Anciano de 80 o más Años , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Adulto Joven
19.
Liver Transpl ; 21(4): 454-67, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25678220

RESUMEN

The goal of this study was to determine whether the detection of discordant numbers of hypervascular foci at hepatic angiography versus contrast-enhanced (CE) cross-sectional imaging [computed tomography (CT) or magnetic resonance imaging (MRI)] is associated with adverse clinical outcomes in patients with hepatocellular carcinoma (HCC) who are listed for liver transplantation. We retrospectively reviewed the records of 218 consecutive patients with HCC who were listed for a liver transplant and who underwent transarterial chemoembolization at our institution between January 1, 2006 and December 31, 2010. Patients were grouped into 3 categories: (1) the number of nodules at CT/MRI was concordant with the number of hypervascular foci detected at angiography (n=136), (2) the number of nodules at CT/MRI was greater than the number of hypervascular foci at angiography (n=45), and (3) the number of nodules at CT/MRI was fewer than the number of hypervascular foci at angiography (n=37). The study outcomes were liver transplantation and tumor recurrence after transplantation. The detection of at least 3 more hypervascular foci at angiography versus the number of HCC nodules on CT/MRI was associated with a significantly lower rate of transplantation [multivariate subhazard ratio (SHR), 0.39; 95% confidence interval (CI), 0.17-0.92]. The detection of fewer hypervascular foci at angiography versus the number of HCC nodules on CT/MRI was associated with a significantly higher rate of tumor recurrence after transplantation (multivariate SHR, 3.49; 95% CI, 1.27-9.56). In conclusion, liver transplant candidates with HCC who demonstrate discordant findings between angiography and CE CT or MRI may be at a higher risk for dropout from the transplant list and for tumor recurrence after transplantation.


Asunto(s)
Angiografía de Substracción Digital , Carcinoma Hepatocelular/diagnóstico , Técnicas de Apoyo para la Decisión , Neoplasias Hepáticas/diagnóstico , Trasplante de Hígado , Imagen por Resonancia Magnética , Selección de Paciente , Tomografía Computarizada por Rayos X , Adulto , Anciano , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/patología , Carcinoma Hepatocelular/cirugía , Medios de Contraste , Femenino , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Neoplasias Hepáticas/cirugía , Trasplante de Hígado/efectos adversos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Recurrencia Local de Neoplasia , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , San Francisco , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
20.
Acta Radiol ; 56(4): 454-7, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24682403

RESUMEN

BACKGROUND: Right adrenal vein (RAV) catheterization can be a very challenging step in adrenal venous sampling (AVS). Visualization of the inferior emissary vein (IEV) may be an indication of successful RAV catheterization. PURPOSE: To compare the rate of successful RAV sampling in the presence of the IEV. MATERIAL AND METHODS: Retrospective review of all consecutive patients with PA who underwent AVS between April 2009 and April 2012 was performed. A total of 30 patients were identified. Procedural images, cortisol, and aldosterone values obtained from sampling of the RAV and inferior vena cava (IVC) were reviewed. Cortisol measurements obtained from RAV samples were divided by measurements from the infra-renal IVC blood samples in order to calculate the selectivity index (SI). An SI >3 was considered indicative of technically successful RAV sampling. RESULTS: RAV sampling was considered technically successful in 29 out of 30 cases (97%). In cases of successful RAV sampling (29 patients), the IEV was identified in 25 patients (86%). The IEV was visualized in isolation in 16 patients (64%), and in conjunction with visualization of the RAV or right adrenal gland stain in nine patients (36%). The IEV was not visualized in the one case of unsuccessful RAV sampling. Visualizing the IEV had a sensitivity of 86.2% for successful RAV sampling. CONCLUSION: The IEV may serve as a reliable landmark for the RAV during RAV sampling.


Asunto(s)
Glándulas Suprarrenales/irrigación sanguínea , Recolección de Muestras de Sangre/métodos , Cateterismo Periférico/métodos , Radiografía Intervencional/métodos , Venas/anatomía & histología , Adolescente , Adulto , Anciano , Femenino , Humanos , Hidrocortisona/sangre , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...