Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Dent Res J (Isfahan) ; 19: 83, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36426284

RESUMEN

The restoration of speech, deglutition, mastication, and respiration in patients with bimaxillary resection involving the maxillae, hard and soft palates, and paranasal sinuses poses a significant challenge. This clinical report describes the prosthodontic management of a patient with bilateral maxillectomy caused due to post-COVID-19 mucormycosis. A patient-specific implants (PSI) that matched the remnants of the zygoma complex was designed to improve the patient's severely impaired speech and swallowing. The patient's postsurgical anatomy was first visualized using three-dimensional computed tomography data. Following that, a customized zygoma-supported titanium framework was designed to support the prosthesis based on the data. Two weeks after the framework was installed, an open-tray impression was made and the prosthesis was fabricated. These findings suggest that PSI-retained prosthesis can be considered in cases with severely compromised maxillary bone anatomy, impaired oral functioning, and no viable conventional reconstruction options.

2.
J Clin Diagn Res ; 11(4): ZC35-ZC39, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28571258

RESUMEN

INTRODUCTION: Emergence of dental implants made the replacement of missing tooth easy. During the early days of introduction, implants were loaded three to six months after implant insertion, but understanding of healing cascade and improved production technology has changed the phase of restoration from delayed to immediate loading. AIM: To evaluate and compare the clinical outcome of immediate and delayed loaded implant supported prosthesis for missing mandibular first molar. The objectives were bleeding on probing, probing depth, implant mobility, marginal bone level and peri-implant radiolucency were evaluated during follow up period. MATERIALS AND METHODS: Twenty patients were included in this study who were in the need of fixed implant supported prosthesis for missing mandibular first molar. Single tooth implant with immediate loading done within two days of implant insertion in one group and another group were loaded after three months of implant insertion. These groups were evaluated clinically and radiographically over a period of 72 months after loading using Wilcoxon matched pairs test and Mann-Whitney U test. RESULTS: The study consists of 14 male and six female patients with the age range of 19 to 31 years. There was no bleeding on probing and probing depth remained well within the normal range even after 72 months of loading among both the groups. Minimal marginal bone loss observed with no mobility and peri-implant radiolucency. CONCLUSION: Implant supported prosthesis for missing mandibular first molar with immediate loading can be used as a successful treatment modality. It reduces treatment time, provides early function and prevents undue migration of adjacent tooth. Immediate loading showed similar clinical and radiographic results as that of delayed loading, indicating it as an equally efficient technique for implant supported prosthesis.

3.
J Int Soc Prev Community Dent ; 6(4): 383-6, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27583229

RESUMEN

Achalasia Cardia is an idiopathic esophageal motor disorder distinguished by the loss of esophageal peristalsis and insufficient relaxation of the lower esophageal sphincter. The oral manifestation of the disease is dental erosion caused by the regurgitation of the gastric contents and vomiting. A female patient aged 14 years reported to the Department of Prosthodontics, Lenora Institute of Dental Sciences, with complaints concerning aesthetics and pain in relation to several teeth. Patient gave history of loss of tooth structure over the past few years with associated sensitivity and pain in several teeth. Patient also gave history of inability to consume sufficient amount of food owing to the repeated vomiting. This paper aims to present a rare case report of achalasia cardia by rehabiliting the remaining teeth with overlay denture.

4.
J Forensic Dent Sci ; 8(3): 173, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-28123274

RESUMEN

After major disasters such as earthquakes, fires, floods, tsunami, bomb blasts or terrorist attacks, accurate, and early identification of the dead and injured becomes an utmost importance. Restorations, cariesteeth, missingteeth and/or prostheses are most useful aids for the dental identification. At times, only identifiable remains are a victim's partial or complete dentures. The central principle of dental identification is that postmortem dental remains can be compared with antemortem dental records which include, studycasts, radiographs, etc., to confirm the identity of the victims. Marking/labeling dentures have been considered an important aid in forensic dentistry. Other than finger printing, when compared with all the methods, the marking/labeling of dentures is an accurate and rapid method to identify the unknown victims. There are no standardized methods to follow, but dental practitioners needs to maintain some dental records of their patients. This may include documentation of the "marking of dentures." The preparedness is the key to success in mass disaster identification. The aim of this review article is to discuss the methods of denture identification, advantages of denture labeling for the rapid identification during major disasters/accidents and the importance of maintaining the patient records.

5.
J Clin Diagn Res ; 8(9): ZC22-5, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25386515

RESUMEN

AIM: The present study was to evaluate the space provided for the temporary luting cement, after the application of various coats of die spacers, during the fabrication of provisional crowns and bridges. MATERIALS AND METHODS: A total of 50 specimens of dental stone with provisional crowns on all these samples were prepared and were divided into five groups based on the application of various coats of different die spacers. Later these specimens were sectioned buccolingually and were observed using a stereomicroscope under 100X magnification. The images thus obtained were evaluated and noted for the amount of space between the inner surface of the provisional crown and the specimens at five different locations using Image Pro 6.0 Express software and the values were subjected to one-way ANOVA test, and unpaired t-test. RESULTS: There was a significant increase of luting space thickness with various die spacer applications than the specimens of control group. CONCLUSION: Specimens of double coat applications of silver and gold die spacers showed higher luting cement space than the separating media application specimens.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...