Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 92(3): 033306, 2021 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-33820038

RESUMEN

This paper reports on the absolute response of a Fuji BAS-TR image plate to relatively low-energy protons (<0.2 MeV) and carbon ions (<1 MeV) accelerated by a 10-TW-class compact high-intensity laser system. A Thomson parabola spectrometer was used to discriminate between different ion species while dispersing the ions according to their kinetic energy. Ion parabolic traces were recorded using an image plate detector overlaid with a slotted CR-39 solid-state detector. The obtained response function for the protons was reasonably extrapolated from previously reported higher-ion-energy response functions. Conversely, the obtained response function for carbon ions was one order of magnitude higher than the value extrapolated from previously reported higher-ion-energy response functions. In a previous study, it was determined that if the stopping range of carbon ions is comparable to or smaller than the grain size of the phosphor, then some ions will provide all their energy to the binder resin rather than the phosphor. As a result, it is believed that the imaging plate response will be reduced. Our results show good agreement with the empirical formula of Lelasseux et al., which does not consider photo-stimulated luminescence (PSL) reduction due to the urethane resin. It was shown that the PSL reduction due to the deactivation of the urethane resin is smaller than that previously predicted.

2.
Rev Sci Instrum ; 91(5): 053305, 2020 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-32486709

RESUMEN

This article reports the development of a compact Thomson parabola spectrometer for laser-accelerated ions that can measure angular distribution with a high energy resolution and has a variable measurable energy range. The angular-resolved energy spectra for different ion species can be measured in a single shot, and the sampling angle can be selected from outside the vacuum region. The electric and magnetic fields are applied to the ion dispersion by using a permanent magnetic circuit and annulus sector-shaped electrodes with a wedge configuration. The compact magnetic circuit consists of permanent magnets, fixed yokes, and movable yokes. The magnetic flux is intentionally leaked to the movable yokes, allowing the magnetic field to be adjusted from 53 mT to 259 mT. The annulus sector-shaped electrodes with a wedge configuration provide better trace separation for high-energy ions, retain the lower-energy part of the ion signal, and subject ions passing through all pinholes to an equivalent Lorentz force. The magnetic and electric fields are designed for measuring protons and carbon ions with an energy range of 0.1-5 MeV. The spectrometer allows for the adjustment of the observable energy range afterward according to the parameters of the accelerated ion.

3.
Opt Lett ; 45(5): 1100-1103, 2020 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-32108780

RESUMEN

We experimentally explore the generation of pre-pulses by post-pulses, created through internal reflection in the optical components, by the nonlinear process associated with the B-integral in the laser chain of the petawatt (PW) facility J-KAREN-P. At a large time delay between the main and the post-pulses, we have found that the pre-pulses are not generated from their counterpart post-pulses at an identical time difference before the main pulse, and the temporal shapes of the pre-pulses are greatly distorted asymmetrically. We have also observed that the peak intensities of the pre-pulses are drastically suppressed compared to the expected value at a small time delay. We briefly describe the origins of the pre-pulses generated by the post-pulses and demonstrate the removal of the pre-pulses by switching to optical components with a small wedge angle at our PW laser facility.

4.
Opt Lett ; 43(11): 2595-2598, 2018 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-29856438

RESUMEN

We report the generation of 63 J of broadband pulse energies at 0.1 Hz from the J-KAREN-P laser, which is based on an OPCPA/Ti:sapphire hybrid architecture. Pulse compression down to 30 fs indicates a peak power of over 1 PW. High temporal contrast of 1012 prior to the main pulse has been demonstrated with 10 J output energy. High intensities of 1022 W/cm2 on target by focusing a 0.3 PW laser with an f/1.3 off-axis parabolic mirror have been achieved. Fundamental processes of laser matter interaction at over 1022 W/cm2 intensities belong to a new branch of science that will be the principal research task of our infrastructure.

5.
Opt Express ; 25(17): 20486-20501, 2017 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-29041729

RESUMEN

J-KAREN-P is a high-power laser facility aiming at the highest beam quality and irradiance for performing state-of-the art experiments at the frontier of modern science. Here we approached the physical limits of the beam quality: diffraction limit of the focal spot and bandwidth limit of the pulse shape, removing the chromatic aberration, angular chirp, wavefront and spectral phase distortions. We performed accurate measurements of the spot and peak fluence after an f/1.3 off-axis parabolic mirror under the full amplification at the power of 0.3 PW attenuated with ten high-quality wedges, resulting in the irradiance of ~1022 W/cm2 and the Strehl ratio of ~0.5.

6.
Rev Sci Instrum ; 87(6): 063307, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27370447

RESUMEN

We propose a simple and effective synchronization technique between a reference electrical oscillator and a mode-locked laser for a narrowband picosecond Laser-Compton scattering γ-ray source by using a commercial-based 1-chip frequency synthesizer, which is widely used in radio communication. The mode-locked laser has been successfully synchronized in time with a jitter of 180 fs RMS for 10 Hz-100 kHz bandwidth. A good stability of 640 µHz at 80 MHz repetition rate for 10 h operation has also been confirmed. We discuss in detail the design and performance of this technique (in terms of timing jitter, stability, and validity).

7.
Opt Express ; 23(25): 31991-2005, 2015 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-26698990

RESUMEN

We present experiments dealing with a femtosecond laser-driven cluster-based plasma, where by analyzing the nonlinear phenomenon of satellites of spectral lines of Ar XVII, we revealed the nonlinear phenomenon of the generation of the second harmonic of the laser frequency. For performing this analysis we developed new results in the theory of satellites of spectral lines. From such lineshape analysis we found, in particular, that the efficiency of converting the short (40 fs) intense (3x10¹8 W/cm²) incident laser light into the second harmonic was 2%. This result is in the excellent agreement with the 2-Dimensional Particle-In-Cell (2D PIC) simulation that we also performed. There is also an order of magnitude agreement between the thresholds for the SHG found from the line shape analysis and from the 2D PIC simulations.

8.
Opt Lett ; 37(14): 2868-70, 2012 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-22825161

RESUMEN

Using a high-contrast (10(10):1) and high-intensity (10(21) W/cm(2)) laser pulse with the duration of 40 fs from an optical parametric chirped-pulse amplification/Ti:sapphire laser, a 40 MeV proton bunch is obtained, which is a record for laser pulse with energy less than 10 J. The efficiency for generation of protons with kinetic energy above 15 MeV is 0.1%.

9.
Opt Lett ; 37(16): 3363-5, 2012 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-23381258

RESUMEN

We demonstrate the temporal contrast enhancement in a petawatt-class Ti:sapphire chirped-pulse amplification (CPA) laser system. An extra saturable absorber, introduced downstream after a low-gain optical parametric chirped-pulse amplification (OPCPA) preamplifier, has improved the temporal contrast in the system to 1.4×10(12) on the subnanosecond time scale at 70 TW power level. We have achieved 28 J of uncompressed broadband output energy with this system, indicating the potential for reaching peak powers near 600 TW.

10.
Opt Lett ; 35(11): 1783-5, 2010 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-20517415

RESUMEN

Segmented (tiled) grating arrays are being intensively investigated for petawatt-scale pulse compression due to the expense and technical challenges of fabricating monolithic diffraction gratings with apertures of over 1m. However, the considerable freedom of motion among grating segments complicates compression and laser focusing. We constructed a real compressor system using a segmented grating for an 18cm aperture laser beam of the Gekko MII 100TW laser system at Osaka University. To produce clean pulse shapes and single focal spots tolerant of misalignment and groove density difference of grating tiles, we applied a new compressor scheme with image rotation in which each beam segment samples each grating segment but from opposite sides. In high-energy shots of up to 50J, we demonstrated nearly Fourier-transform-limited pulse compression (0.5ps) with an almost diffraction-limited spot size (20microm).

11.
Appl Opt ; 49(11): 2105-15, 2010 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-20390013

RESUMEN

We have developed a femtosecond high-intensity laser system that combines both Ti:sapphire chirped-pulse amplification (CPA) and optical parametric CPA (OPCPA) techniques and produces more than 30 J broadband output energy, indicating the potential for achieving peak powers in excess of 500 TW. With a cleaned high-energy seeded OPCPA preamplifier as a front end in the system, for the compressed pulse without pumping the final amplifier, we found that the temporal contrast in this system exceeds 10(10) on the subnanosecond time scales, and is near 10(12) on the nanosecond time scale prior to the peak of the main femtosecond pulse. Using diffractive optical elements for beam homogenization of a 100 J level high-energy Nd:glass green pump laser in a Ti:sapphire final amplifier, we have successfully generated broadband high-energy output with a near-perfect top-hat-like intensity distribution.


Asunto(s)
Rayos Láser , Óptica y Fotónica , Óxido de Aluminio/química , Amplificadores Electrónicos , Diseño de Equipo , Riesgo , Procesamiento de Señales Asistido por Computador/instrumentación , Factores de Tiempo , Titanio/química
12.
Opt Lett ; 33(16): 1902-4, 2008 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-18709127

RESUMEN

We introduce a four-pass laser pulse compressor design based on two grating apertures with two gratings per aperture that is tolerant to some alignment errors and, importantly, to grating-to-grating period variations. Each half-beam samples each grating in a diamond-shaped compressor that is symmetric about a central bisecting plane. For any given grating, the two half-beams impinge on opposite sides of its surface normal. It is shown that the two split beams have no pointing difference from paired gratings with different periods. Furthermore, no phase shift between half-beams is incurred as long as the planes containing a grating line and the surface normal for each grating of the pair are parallel. For grating pairs satisfying this condition, gratings surfaces need not be on the same plane, as changes in the gap between the two can compensate to bring the beams back in phase.

13.
Phys Rev E Stat Nonlin Soft Matter Phys ; 65(1 Pt 2): 016402, 2002 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-11800785

RESUMEN

The second-harmonic emission generated by the spatially asymmetric quivering electrons caused by the ponderomotive force was studied. The intensity of the second harmonic was proportional to the focused intensity of the pump pulse with the power of 1.8. This intensity dependence can be explained by the relativistic effect of the quivering electrons.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA