Phys Med Biol ; 58(8): 2641-55, 2013 Apr 21.
Artículo en Inglés | MEDLINE | ID: mdl-23552717

RESUMEN

Scintillation gamma cameras based on low-noise electron multiplication (EM-)CCDs can reach high spatial resolutions. For further improvement of these gamma cameras, more insight is needed into how various parameters that characterize these devices influence their performance. Here, we use the Cramer-Rao lower bound (CRLB) to investigate the sensitivity of the energy and spatial resolution of an EM-CCD-based gamma camera to several parameters. The gamma camera setup consists of a 3 mm thick CsI(Tl) scintillator optically coupled by a fiber optic plate to the E2V CCD97 EM-CCD. For this setup, the position and energy of incoming gamma photons are determined with a maximum-likelihood detection algorithm. To serve as the basis for the CRLB calculations, accurate models for the depth-dependent scintillation light distribution are derived and combined with a previously validated statistical response model for the EM-CCD. The sensitivity of the lower bounds for energy and spatial resolution to the EM gain and the depth-of-interaction (DOI) are calculated and compared to experimentally obtained values. Furthermore, calculations of the influence of the number of detected optical photons and noise sources in the image area on the energy and spatial resolution are presented. Trends predicted by CRLB calculations agree with experiments, although experimental values for spatial and energy resolution are typically a factor of 1.5 above the calculated lower bounds. Calculations and experiments both show that an intermediate EM gain setting results in the best possible spatial or energy resolution and that the spatial resolution of the gamma camera degrades rapidly as a function of the DOI. Furthermore, calculations suggest that a large improvement in gamma camera performance is achieved by an increase in the number of detected photons or a reduction of noise in the image area. A large noise reduction, as is possible with a new generation of EM-CCD electronics, may improve the energy and spatial resolution by a factor of 1.5.


Asunto(s)
Equipos y Suministros Eléctricos , Electrones , Cámaras gamma , Luz , Luminiscencia , Fibras Ópticas , Fenómenos Ópticos , Fotones
2.
Phys Med Biol ; 57(14): 4545-54, 2012 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-22722678

RESUMEN

Detection of x-rays and gamma rays with high spatial resolution can be achieved with scintillators that are optically coupled to electron-multiplying charge-coupled devices (EMCCDs). These can be operated at typical frame rates of 50 Hz with low noise. In such a set-up, scintillation light within each frame is integrated after which the frame is analyzed for the presence of scintillation events. This method allows for the use of scintillator materials with relatively long decay times of a few milliseconds, not previously considered for use in photon-counting gamma cameras, opening up an unexplored range of dense scintillators. In this paper, we test CdWO4 and transparent polycrystalline ceramics of Lu2O3:Eu and (Gd,Lu)2O3:Eu as alternatives to currently used CsI:Tl in order to improve the performance of EMCCD-based gamma cameras. The tested scintillators were selected for their significantly larger cross-sections at 140 keV ((99m)Tc) compared to CsI:Tl combined with moderate to good light yield. A performance comparison based on gamma camera spatial and energy resolution was done with all tested scintillators having equal (66%) interaction probability at 140 keV. CdWO4, Lu2O3:Eu and (Gd,Lu)2O3:Eu all result in a significantly improved spatial resolution over CsI:Tl, albeit at the cost of reduced energy resolution. Lu2O3:Eu transparent ceramic gives the best spatial resolution: 65 µm full-width-at-half-maximum (FWHM) compared to 147 µm FWHM for CsI:Tl. In conclusion, these 'slow' dense scintillators open up new possibilities for improving the spatial resolution of EMCCD-based scintillation cameras.


Asunto(s)
Diagnóstico por Imagen/instrumentación , Equipos y Suministros Eléctricos , Rayos gamma , Conteo por Cintilación/instrumentación , Cámaras gamma , Fotones , Probabilidad , Radiofármacos
3.
Phys Med Biol ; 56(15): 4785-801, 2011 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-21753231

RESUMEN

Gamma cameras based on charge-coupled devices (CCDs) coupled to continuous scintillation crystals can combine a good detection efficiency with high spatial resolutions with the aid of advanced scintillation detection algorithms. A previously developed analytical multi-scale algorithm (MSA) models the depth-dependent light distribution but does not take statistics into account. Here we present and validate a novel statistical maximum-likelihood algorithm (MLA) that combines a realistic light distribution model with an experimentally validated statistical model. The MLA was tested for an electron multiplying CCD optically coupled to CsI(Tl) scintillators of different thicknesses. For (99m)Tc imaging, the spatial resolution (for perpendicular and oblique incidence), energy resolution and signal-to-background counts ratio (SBR) obtained with the MLA were compared with those of the MSA. Compared to the MSA, the MLA improves the energy resolution by more than a factor of 1.6 and the SBR is enhanced by more than a factor of 1.3. For oblique incidence (approximately 45°), the depth-of-interaction corrected spatial resolution is improved by a factor of at least 1.1, while for perpendicular incidence the MLA resolution does not consistently differ significantly from the MSA result for all tested scintillator thicknesses. For the thickest scintillator (3 mm, interaction probability 66% at 141 keV) a spatial resolution (perpendicular incidence) of 147 µm full width at half maximum (FWHM) was obtained with an energy resolution of 35.2% FWHM. These results of the MLA were achieved without prior calibration of scintillations as is needed for many statistical scintillation detection algorithms. We conclude that the MLA significantly improves the gamma camera performance compared to the MSA.


Asunto(s)
Electrones , Cámaras gamma , Conteo por Cintilación/instrumentación , Algoritmos , Luz , Funciones de Verosimilitud , Modelos Lineales , Reproducibilidad de los Resultados
4.
Phys Med Biol ; 54(13): N267-72, 2009 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-19521006

RESUMEN

The performance of pinhole single photon emission computed tomography (SPECT) depends on the spatial resolution of the gamma-ray detectors used. Pinhole cameras suffer from strong resolution loss due to the varying depth-of-interaction (DOI) of gamma quanta that enter the detector material at an angle. We eliminate DOI effects in a scintillation gamma camera via a dedicated optic fiber bundle that acts as a focusing collimator for light generated in a scintillation crystal. A curved crystal is connected to a concavely shaped fiber-optic bundle such that the fibers connect perpendicularly to the crystal's convex surface and point straight at the pinhole opening. Limiting the fiber numerical apertures can be used to suppress resolution losses due to light spread. Here we demonstrate experimentally that this prototype position-sensitive gamma sensor successfully eliminates DOI effects, and has an intrinsic resolution of better than 280 microm full width at half maximum with an interaction probability of 67% for 140 keV photons. Therefore, the detector has great potential for increasing the resolution of pinhole SPECT.


Asunto(s)
Artefactos , Cámaras gamma , Aumento de la Imagen/instrumentación , Tomografía Computarizada de Emisión de Fotón Único/instrumentación , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
5.
Phys Med Biol ; 54(10): 3003-14, 2009 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-19387099

RESUMEN

High-resolution imaging of x-ray and gamma-ray distributions can be achieved with cameras that use charge coupled devices (CCDs) for detecting scintillation light flashes. The energy and interaction position of individual gamma photons can be determined by rapid processing of CCD images of individual flashes. Here we investigate the improvement of such a gamma camera when a micro-machined retro-reflector is used to increase the light output of a continuous scintillation crystal. At 122 keV we found that retro-reflectors improve the intrinsic energy resolution (full width at half maximum (FWHM)) by 32% (from 50% to 34%) and the signal-to-noise (SNR) ratio by 18%. The spatial resolution (FWHM) was improved by about 4%, allowing us to obtain a resolution of 159 microm. The full width at tenth maximum (FWTM) improvement was 13%. Therefore, this enhancement is a next step towards realizing compact high-resolution devices for imaging gamma emitters.


Asunto(s)
Cámaras gamma , Aumento de la Imagen/métodos , Lentes , Iluminación/instrumentación , Cintigrafía/instrumentación , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo , Miniaturización , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
Phys Med Biol ; 54(4): 831-42, 2009 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-19141886

RESUMEN

Gamma cameras based on charge-coupled devices (CCDs) and micro-columnar CsI scintillators can reach high spatial resolutions. However, the gamma interaction probability of these scintillators is low (typically <30% at 141 keV) due to the limited thickness of presently available micro-columnar scintillators. Continuous scintillators can improve the interaction probability but suffer from increased light spread compared to columnar scintillators. In addition, for both types of scintillators, gamma photons incident at an oblique angle reduce the spatial resolution due to the variable depth of interaction (DOI). To improve the spatial resolution and spectral characteristics of these detectors, we have developed a fast analytic scintillation detection algorithm that makes use of a depth-dependent light spread model and as a result is able to estimate the DOI in the scintillator. This algorithm, performing multi-scale frame analysis, was tested for an electron multiplying CCD (EM-CCD) optically coupled to CsI(Tl) scintillators of different thicknesses. For the thickest scintillator (2.6 mm) a spatial resolution of 148 microm full width half maximum (FWHM) was obtained with an energy resolution of 46% FWHM for perpendicularly incident gamma photons (interaction probability 61% at 141 keV). The multi-scale algorithm improves the spatial resolution up to 11%, the energy resolution up to 36% and the signal-to-background counts ratio up to 46% compared to a previously implemented algorithm that did not model the depth-dependent light spread. In addition, the multi-scale algorithm can accurately estimate DOI. As a result, degradation of the spatial resolution due to the variable DOI for gamma photons incident at a 45 degrees angle was improved from 2.0 10(3) to 448 microm FWHM. We conclude that the multi-scale algorithm significantly improves CCD-based gamma cameras as can be applied in future SPECT systems.


Asunto(s)
Algoritmos , Cámaras gamma , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Cintigrafía/instrumentación , Cintigrafía/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador/instrumentación