RESUMEN
BACKGROUND: Transplant coronary arteriopathy (TCAD) limits graft survival after heart transplantation in adult and pediatric heart transplant recipients. Intravascular ultrasound (IVUS) provides a highly sensitive technique to detect TCAD. However, its use to determine factors associated with TCAD in pediatric recipients has been limited and its utility in surveillance for symptomatic TCAD in this population is uncertain. METHODS: One hundred fifty-eight IVUS studies from 66 patients (27 <1 year and 39 >1 year at time of transplant) were performed 12 to 144 months after transplantation within the routine surveillance for TCAD. Maximal intimal thickness (MIT) and intimal index (II) were measured, and the Stanford classification was utilized to grade overall severity of disease. Mixed repeated-measures linear regression models were used to investigate the main and interaction effects of age at transplant, age at time of study, time since transplant and rejection events. RESULTS: Age at catheterization (p = 0.0002), transplantation at age >12 months (p = 0.014), increasing time after transplantation (p = 0.021) and the combination of late rejection and hemodynamic compromising rejection (p = 0.05) were significantly associated with increasing MIT. Age at catheterization (p = 0.0149), transplantation at age >12 months (p = 0.016), time from transplantation (p = 0.0076) and rejection with hemodynamic compromise (p = 0.01) were significantly associated with increased II. Nine patients developed evidence of severe (Stanford Class 4) TCAD by IVUS, but only 2 (22%) developed symptomatic TCAD, with a median follow-up of 44 months. Four of the 7 patients who developed symptomatic TCAD had no or minimal TCAD (Stanford Class 0 or 1) on a surveillance examination within 18 months of the onset of symptoms. CONCLUSIONS: Increasing time after transplantation, recipient age and age at transplantation as well as rejection history, especially rejection with hemodynamic compromise, are associated with the development of TCAD as detected by IVUS in pediatric heart transplant recipients. Severe TCAD detected by IVUS does not often rapidly progress to symptomatic TCAD. Symptomatic TCAD may develop rapidly even in patients with little or no TCAD detected by IVUS.
Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/etiología , Trasplante de Corazón/efectos adversos , Ultrasonografía Intervencional , Adolescente , Adulto , Factores de Edad , Niño , Preescolar , Estudios Transversales , Femenino , Rechazo de Injerto/epidemiología , Humanos , Lactante , Recién Nacido , Masculino , Vigilancia de la Población , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Factores de TiempoRESUMEN
Brain natriuretic peptide (BNP) levels were obtained before cardiac catheterization in 193 pediatric patients with a variety of cardiac lesions. Age and functional status had strong relations to BNP values, with elevations of BNP levels associated with increasing functional disability and decreasing age. Mild but statistically significant correlations were found between BNP levels and right-sided cardiac pressures. In patients with volume-overloaded ventricles, BNP correlated with the degree of overcirculation.
Asunto(s)
Cardiopatías/sangre , Cardiopatías/fisiopatología , Péptido Natriurético Encefálico/sangre , Índice de Severidad de la Enfermedad , Adolescente , Factores de Edad , Niño , Preescolar , Estudios Transversales , Femenino , Humanos , Lactante , Masculino , Estudios ProspectivosRESUMEN
PURPOSE: To describe the chest radiographic appearance of the Amplatzer septal occluder (ASO) (AGA Medical Corporation, Golden Valley, Minn) for atrial septal defects (ASDs) in pediatric patients. MATERIALS AND METHODS: Two radiologists independently reviewed frontal and lateral chest radiographs obtained in young patients 24 hours after transcatheter ASD closure with the ASO. The appearance (flat disks or dots) and location of the ASO were recorded. The location was related to that of a thoracic vertebral body on frontal and lateral chest radiographs and to a line drawn between the anterior margin of the right hilum and the posterior margin of the inferior vena cava (hilar-caval line) on lateral radiographs; this line corresponded to the expected position of the interatrial septum. The relationship between ASO appearance and patient age was assessed with logistic regression and cumulative probability plots. RESULTS: Sixty-eight pediatric patients (age range, 1 month to 18 years; mean age, 4.2 years; 24 boys and 44 girls) were included. On frontal radiographs, the ASO center projected between T7 and T9, either to the right of or over the spinous processes of the vertebral body. On lateral radiographs, the ASO projected over (n = 66) or anterior to (n = 2) the hilar-caval line. On frontal radiographs, it appeared as one or two flat disks (n = 61) or as two metallic dots (n = 7). On lateral radiographs, it appeared as two flat disks (n = 54) or as two metallic dots (n = 14). The relationship between increasing patient age and the metallic dot appearance on frontal and lateral radiographs and on the combination of frontal and lateral radiographs was highly significant in each case (P < .001, likelihood ratio chi(2) test), with r(2) values of 0.35, 0.20, and 0.28, respectively. ASDs were successfully occluded with the ASO in all patients except one, in whom trivial shunting was seen at 12-month follow-up. CONCLUSION: The ASO in pediatric patients has a characteristic radiographic appearance when properly positioned.
Asunto(s)
Defectos del Tabique Interatrial/diagnóstico por imagen , Defectos del Tabique Interatrial/terapia , Adolescente , Cateterismo Cardíaco , Niño , Preescolar , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Radiografía Torácica , Resultado del TratamientoRESUMEN
Perivalvar leak following atrioventricular valve replacement can result in heart failure or hemolytic anemia. These patients may be poor surgical candidates given a complex clinical condition. We describe transcatheter closure of a perivalvar leak in a 3-month infant who had undergone left atrioventricular valve replacement with a St. Jude's prosthesis.
Asunto(s)
Embolización Terapéutica/instrumentación , Enfermedades de las Válvulas Cardíacas/etiología , Enfermedades de las Válvulas Cardíacas/terapia , Prótesis Valvulares Cardíacas/efectos adversos , Válvula Mitral/anomalías , Válvula Mitral/cirugía , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/terapia , Reoperación , Cateterismo Cardíaco , Ecocardiografía , Ecocardiografía Transesofágica , Atrios Cardíacos/anomalías , Atrios Cardíacos/cirugía , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/cirugía , Enfermedades de las Válvulas Cardíacas/diagnóstico , Ventrículos Cardíacos/anomalías , Ventrículos Cardíacos/cirugía , Humanos , Lactante , Masculino , Complicaciones Posoperatorias/diagnósticoRESUMEN
Baffle-related complications following atrial switch procedures for transposition are relatively common. Transcatheter treatment of baffle stenosis has an established role as a therapeutic modality. However, transcatheter device closure of atrial baffles leaks has rarely been reported. We report four patients who underwent device closure of baffle leaks using the Amplatzer septal occluder following atrial switch procedures in order to demonstrate the safety and utility of this method of treatment and to establish its role as a suitable alternative to surgical closure.
Asunto(s)
Oclusión con Balón , Prótesis Vascular , Defectos del Tabique Interatrial/cirugía , Transposición de los Grandes Vasos/cirugía , Adolescente , Adulto , Cateterismo Cardíaco , Procedimientos Quirúrgicos Cardíacos , Preescolar , Angiografía Coronaria , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Complicaciones Posoperatorias , Falla de PrótesisRESUMEN
Acquired pulmonary artery discontinuity can complicate operative repair of certain congenital heart defects. We describe successful recanalization of acquired left pulmonary artery atresia using radiofrequency energy in a 14-month-old child who had previously undergone repair of tetralogy of Fallot with pulmonary atresia.
Asunto(s)
Ablación por Catéter , Arteria Pulmonar/anomalías , Arteria Pulmonar/cirugía , Atresia Pulmonar/cirugía , Tetralogía de Fallot/cirugía , Anomalías Múltiples/fisiopatología , Anomalías Múltiples/cirugía , Prótesis Vascular , Ecocardiografía , Femenino , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/fisiopatología , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Humanos , Recién Nacido , Arteria Pulmonar/diagnóstico por imagen , Atresia Pulmonar/fisiopatología , Circulación Pulmonar/fisiología , Stents , Tetralogía de Fallot/fisiopatologíaRESUMEN
BACKGROUND: This study was performed to determine whether a preoperative hemodynamic evaluation with oxygen and inhaled nitric oxide identifies patients with pulmonary hypertension who are appropriate candidates for corrective cardiac surgery or transplantation more accurately than an evaluation with oxygen alone. METHODS AND RESULTS: At 10 institutions, 124 patients with heart disease and severe pulmonary hypertension underwent cardiac catheterization to determine operability. The ratio of pulmonary and systemic vascular resistance (Rp:Rs) was determined at baseline while breathing approximately 21% to 30% oxygen, and in approximately 100% oxygen and approximately 100% oxygen with 10 to 80 parts per million nitric oxide to evaluate pulmonary vascular reactivity. Surgery was performed in 74 patients. Twelve patients died or developed right heart failure secondary to pulmonary hypertension following surgery. Rp:Rs<0.33 and a 20% decrease in Rp:Rs from baseline were chosen as 2 criteria for operability to determine, in retrospect, the efficacy of preoperative testing in patient selection. In comparison to an evaluation with oxygen alone, sensitivity (64% versus 97%) and accuracy (68% versus 90%) were increased by an evaluation with oxygen and nitric oxide when Rp:Rs<0.33 was used as the criterion for operability. Specificity was only 8% when a 20% decrease in Rp:Rs from baseline was used as the criterion for operability. CONCLUSION: By using a combination of oxygen and inhaled nitric oxide, a greater number of appropriate candidates for corrective cardiac surgery or transplantation can be identified during preoperative testing when a specific value of Rp:Rs is used as a criterion for operability.