Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Biomacromolecules ; 24(8): 3806-3818, 2023 08 14.
Artículo en Inglés | MEDLINE | ID: mdl-37433182

RESUMEN

Protein fouling is a critical issue in the development of electrochemical sensors for medical applications, as it can significantly impact their sensitivity, stability, and reliability. Modifying planar electrodes with conductive nanomaterials that possess a high surface area, such as carbon nanotubes (CNTs), has been shown to significantly improve fouling resistance and sensitivity. However, the inherent hydrophobicity of CNTs and their poor dispersibility in solvents pose challenges in optimizing such electrode architectures for maximum sensitivity. Fortunately, nanocellulosic materials offer an efficient and sustainable approach to achieving effective functional and hybrid nanoscale architectures by enabling stable aqueous dispersions of carbon nanomaterials. Additionally, the inherent hygroscopicity and fouling-resistant nature of nanocellulosic materials can provide superior functionalities in such composites. In this study, we evaluate the fouling behavior of two nanocellulose (NC)/multiwalled carbon nanotube (MWCNT) composite electrode systems: one using sulfated cellulose nanofibers and another using sulfated cellulose nanocrystals. We compare these composites to commercial MWCNT electrodes without nanocellulose and analyze their behavior in physiologically relevant fouling environments of varying complexity using common outer- and inner-sphere redox probes. Additionally, we use quartz crystal microgravimetry with dissipation monitoring (QCM-D) to investigate the behavior of amorphous carbon surfaces and nanocellulosic materials in fouling environments. Our results demonstrate that the NC/MWCNT composite electrodes provide significant advantages for measurement reliability, sensitivity, and selectivity over only MWCNT-based electrodes, even in complex physiological monitoring environments such as human plasma.


Asunto(s)
Nanotubos de Carbono , Humanos , Nanotubos de Carbono/química , Adsorción , Reproducibilidad de los Resultados , Técnicas Electroquímicas/métodos , Electrodos , Proteínas , Celulosa
2.
Br J Clin Pharmacol ; 89(9): 2933-2938, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37218304

RESUMEN

AIMS: Measuring venous plasma paracetamol concentrations is time- and resource-consuming. We aimed to validate a novel electrochemical point-of-care (POC) assay for rapid paracetamol concentration determinations. METHODS: Twelve healthy volunteers received 1 g oral paracetamol, and its concentrations were analysed 10 times over 12 h for capillary whole blood (POC), venous plasma (high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS)), and dried capillary blood (HPLC-MS/MS). RESULTS: At concentrations >30 µM, POC showed upward biases of 20% (95% limits of agreement [LOA] -22 to 62) and 7% (95% LOA -23 to 38) compared with venous plasma and capillary blood HPLC-MS/MS, respectively. There were no significant differences between mean concentrations for the paracetamol elimination phase. CONCLUSIONS: Upward biases in POC compared with venous plasma HPLC-MS/MS were likely due to higher paracetamol concentrations in capillary blood than in venous plasma and to faulty individual sensors. The novel POC method is a promising tool for paracetamol concentration analysis.


Asunto(s)
Acetaminofén , Espectrometría de Masas en Tándem , Humanos , Sistemas de Atención de Punto , Cromatografía Líquida de Alta Presión/métodos , Factores de Riesgo
3.
ACS Omega ; 6(17): 11563-11569, 2021 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-34056312

RESUMEN

Disposable single-use electrochemical sensor strips were used for quantitative detection of small concentrations of morphine in untreated capillary whole blood. Single-walled carbon nanotube (SWCNT) networks were fabricated on a polymer substrate to produce flexible, reproducible sensor strips with integrated reference and counter electrodes, compatible with industrial-scale processes. A thin Nafion coating was used on top of the sensors to enable direct electrochemical detection in whole blood. These sensors were shown to detect clinically relevant concentrations of morphine both in buffer and in whole blood samples. Small 38 µL finger-prick blood samples were spiked with 2 µL of morphine solution of several concentrations and measured without precipitation of proteins or any other further pretreatment. A linear range of 0.5-10 µM was achieved in both matrices and a detection limit of 0.48 µM in buffer. In addition, to demonstrate the applicability of the sensor in a point-of-care device, single-determination measurements were done with capillary samples from three subjects. An average recovery of 60% was found, suggesting that the sensor only measures the free, unbound fraction of the drug. An interference study with other opioids and possible interferents showed the selectivity of the sensor. This study clearly indicates that these Nafion/SWCNT sensor strips show great promise as a point-of-care rapid test for morphine in blood.

4.
Anal Chem ; 92(19): 13017-13024, 2020 10 06.
Artículo en Inglés | MEDLINE | ID: mdl-32842738

RESUMEN

A disposable electrochemical test strip for the quantitative point-of-care (POC) determination of acetaminophen (paracetamol) in plasma and finger-prick whole blood was fabricated. The industrially scalable dry transfer process of single-walled carbon nanotubes (SWCNTs) and screen printing of silver were combined to produce integrated electrochemical test strips. Nafion coating stabilized the potential of the Ag reference electrode and enabled the selective detection in spiked plasma as well as in whole blood samples. The test strips were able to detect acetaminophen in small 40 µL samples with a detection limit of 0.8 µM and a wide linear range from 1 µM to 2 mM, well within the required clinical range. After a simple 1:1 dilution of plasma and whole blood, a quantitative detection with good recoveries of 79% in plasma and 74% in whole blood was achieved. These results strongly indicate that these electrodes can be used directly to determine the unbound acetaminophen fraction without the need for any additional steps. The developed test strip shows promise as a rapid and simple POC quantitative acetaminophen assay.


Asunto(s)
Acetaminofén/sangre , Técnicas Electroquímicas , Dedos , Nanotubos de Carbono/química , Tiras Reactivas/química , Recolección de Muestras de Sangre , Humanos
5.
Phys Chem Chem Phys ; 22(29): 16630-16640, 2020 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-32666973

RESUMEN

Biofouling imposes a significant threat for sensing probes used in vivo. Antifouling strategies commonly utilize a protective layer on top of the electrode but this may compromise performance of the electrode. Here, we investigated the effect of surface topography and chemistry on fouling without additional protective layers. We have utilized two different carbon materials; tetrahedral amorphous carbon (ta-C) and SU-8 based pyrolytic carbon (PyC) in their typical smooth thin film structure as well as with a nanopillar topography templated from black silicon. The near edge X-ray absorption fine structure (NEXAFS) spectrum revealed striking differences in chemical functionalities of the surfaces. PyC contained equal amounts of ketone, hydroxyl and ether/epoxide groups, while ta-C contained significant amounts of carbonyl groups. Overall, oxygen functionalities were significantly increased on nanograss surfaces compared to the flat counterparts. Neither bovine serum albumin (BSA) or fetal bovine serum (FBS) fouling caused major effects on electron transfer kinetics of outer sphere redox (OSR) probe Ru(NH3)63+ on any of the materials. In contrast, negatively charged OSR probe IrCl62- kinetics were clearly affected by fouling, possibly due to the electrostatic repulsion between redox species and the anionically-charged proteins adsorbed on the electrode and/or stronger interaction of the proteins and positively charged surface. The OSR probe kinetics were less affected by fouling on PyC, probably due to conformational changes of proteins on the surface. Dopamine (DA) was tested as an inner sphere redox (ISR) probe and as expected, the kinetics were heavily dependent on the material; PyC had very fast electron transfer kinetics, while ta-C had sluggish kinetics. DA electron transfer kinetics were heavily affected on all surfaces by fouling (ΔEp increase 30-451%). The effect was stronger on PyC, possibly due to the more strongly adhered protein layer limiting the access of the probe to the inner sphere.


Asunto(s)
Incrustaciones Biológicas , Técnicas Biosensibles , Carbono/química , Electroquímica , Cinética , Oxidación-Reducción , Proteínas/química , Silicio/química , Propiedades de Superficie
6.
Anal Chem ; 92(12): 8218-8227, 2020 06 16.
Artículo en Inglés | MEDLINE | ID: mdl-32412733

RESUMEN

Oxycodone is a strong opioid frequently used as an analgesic. Although proven efficacious in the management of moderate to severe acute pain and cancer pain, use of oxycodone imposes a risk of adverse effects such as addiction, overdose, and death. Fast and accurate determination of oxycodone blood concentration would enable personalized dosing and monitoring of the analgesic as well as quick diagnostics of possible overdose in emergency care. However, in addition to the parent drug, several metabolites are always present in the blood after a dose of oxycodone, and to date, there is no electrochemical data available on any of these metabolites. In this paper, a single-walled carbon nanotube (SWCNT) electrode and a Nafion-coated SWCNT electrode were used, for the first time, to study the electrochemical behavior of oxycodone and its two main metabolites, noroxycodone and oxymorphone. Both electrode types could selectively detect oxycodone in the presence of noroxycodone and oxymorphone. However, we have previously shown that addition of a Nafion coating on top of the SWCNT electrode is essential for direct measurements in complex biological matrices. Thus, the Nafion/SWCNT electrode was further characterized and used for measuring clinically relevant concentrations of oxycodone in buffer solution. The limit of detection for oxycodone with the Nafion/SWCNT sensor was 85 nM, and the linear range was 0.5-10 µM in buffer solution. This study shows that the fabricated Nafion/SWCNT sensor has potential to be applied in clinical concentration measurements.


Asunto(s)
Técnicas Electroquímicas , Polímeros de Fluorocarbono/química , Nanotubos de Carbono/química , Oxicodona/análisis , Electrodos , Estructura Molecular , Oxicodona/metabolismo , Tamaño de la Partícula , Propiedades de Superficie
7.
Mol Neurobiol ; 57(1): 179-190, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31520316

RESUMEN

Age structure in most developed countries is changing fast as the average lifespan is increasing significantly, calling for solutions to provide improved treatments for age-related neurological diseases and disorders. In order to address these problems, a reliable way of recording information about neurotransmitters from in vitro and in vivo applications is needed to better understand neurological diseases and disorders as well as currently used treatments. Likewise, recent developments in medicine, especially with the opioid crisis, are demanding a swift move to personalized medicine to administer patient needs rather than population-wide averages. In order to enable the so-called personalized medicine, it is necessary to be able to do measurements in vivo and in real time. These actions require sensitive and selective detection of different analytes from very demanding environments. Current state-of-the-art materials are unable to provide sensitive and selective detection of neurotransmitters as well as the required time resolution needed for drug molecules at a reasonable cost. To meet these challenges, we have utilized different metals to grow carbon nanomaterials and applied them for sensing applications showing that there are clear differences in their electrochemical properties based on the selected catalyst metal. Additionally, we have combined atomistic simulations to support optimizing materials for experiments and to gain further understanding of the atomistic level reactions between different analytes and the sensor surface. With carbon nanostructures grown from Ni and Al + Co + Fe hybrid, we can detect dopamine, ascorbic acid, and uric acid simultaneously. On the other hand, nanostructures grown from platinum provide a feasible platform for detection of H2O2 making them suitable candidates for enzymatic biosensors for detection of glutamate, for example. Tetrahedral amorphous carbon electrodes have an ability to detect morphine, paracetamol, tramadol, and O-desmethyltramadol. With carbon nanomaterial-based sensors, it is possible to reach metal-like properties in sensing applications using only a fraction of the metal as seed for the material growth. We have also seen that by using nanodiamonds as growth catalyst for carbon nanofibers, it is not possible to detect dopamine and ascorbic acid simultaneously, although the morphology of the resulting nanofibers is similar to the ones grown using Ni. This further indicates the importance of the metal selection for specific applications. However, Ni as a continuous layer or as separate islands does not provide adequate performance. Thus, it appears that metal nanoparticles combined with fiber-like morphology are needed for optimized sensor performance for neurotransmitter detection. This opens up a new research approach of application-specific nanomaterials, where carefully selected metals are integrated with carbon nanomaterials to match the needs of the sensing application in question.


Asunto(s)
Carbono/metabolismo , Peróxido de Hidrógeno/metabolismo , Nanopartículas del Metal , Nanotubos de Carbono/química , Técnicas Biosensibles/métodos , Dopamina/metabolismo , Técnicas Electroquímicas , Humanos , Metales/metabolismo , Nanoestructuras/química , Neurotransmisores/metabolismo
8.
ACS Omega ; 4(18): 17726-17734, 2019 Oct 29.
Artículo en Inglés | MEDLINE | ID: mdl-31681878

RESUMEN

In clinical settings, the dosing and differential diagnosis of the poisoning of morphine (MO) and codeine (CO) is challenging due to interindividual variations in metabolism. However, direct electrochemical detection of these analytes from biological matrices is inherently challenging due to interference from large concentrations of anions, such as ascorbic acid (AA) and uric acid (UA), as well as fouling of the electrode by proteins. In this work, a disposable Nafion-coated single-walled carbon nanotube network (SWCNT) electrode was developed. We show facile electron transfer and efficient charge separation between the interfering anions and positively charged MO and CO, as well as significantly reduced matrix effect in human plasma. The Nafion coating alters the voltammetric response of MO and CO, enabling simultaneous detection. With this SWCNT/Nafion electrode, two linear ranges of 0.05-1 and 1-10 µM were found for MO and one linear range of 0.1-50 µM for CO. Moreover, the selective and simultaneous detection of MO and CO was achieved in large excess of AA and UA, as well as, for the first time, in unprocessed human plasma. The favorable properties of this electrode enabled measurements in plasma with only mild dilution and without the precipitation of proteins.

9.
Micromachines (Basel) ; 10(8)2019 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-31370267

RESUMEN

Pattern formation of pyrolyzed carbon (PyC) and tetrahedral amorphous carbon (ta-C) thin films were investigated at micro- and nanoscale. Micro- and nanopillars were fabricated from both materials, and their biocompatibility was studied with cell viability tests. Carbon materials are known to be very challenging to pattern. Here we demonstrate two approaches to create biocompatible carbon features. The microtopographies were 2 µ m or 20 µ m pillars (1:1 aspect ratio) with three different pillar layouts (square-grid, hexa-grid, or random-grid orientation). The nanoscale topography consisted of random nanopillars fabricated by maskless anisotropic etching. The PyC structures were fabricated with photolithography and embossing techniques in SU-8 photopolymer which was pyrolyzed in an inert atmosphere. The ta-C is a thin film coating, and the structures for it were fabricated on silicon substrates. Despite different fabrication methods, both materials were formed into comparable micro- and nanostructures. Mouse neural stem cells were cultured on the samples (without any coatings) and their viability was evaluated with colorimetric viability assay. All samples expressed good biocompatibility, but the topography has only a minor effect on viability. Two µ m pillars in ta-C shows increased cell count and aggregation compared to planar ta-C reference sample. The presented materials and fabrication techniques are well suited for applications that require carbon chemistry and benefit from large surface area and topography, such as electrophysiological and -chemical sensors for in vivo and in vitro measurements.

11.
ACS Omega ; 3(2): 1791-1800, 2018 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-30263976

RESUMEN

Corrosion protection of steel obtained with physical vapor deposition (PVD) coatings can be further improved by sealing the intrinsic pinholes with atomic layer deposition (ALD) coatings. In this work, the effect of surface wear on corrosion protection obtained by a hybrid PVD CrN/ALD Al2O3/TiO2 nanolaminate coating was studied. The samples were investigated by alternating surface wear steps and exposure to salt solution and consecutively the progression of corrosion after each wear and each corrosion step was evaluated. Optical microscopy, scanning electron microscopy (SEM), and energy-dispersive spectroscopy showed that the rust spots were almost exclusively located on positions at which the wear steps had removed the top surface of the PVD CrN coating. Nevertheless, even after complete removal of the ALD nanolaminate from the top of the CrN surface by sandpaper grinding, the corrosion current density was less than half compared to the PVD CrN coating alone without surface wear. Cross-sectional SEM images obtained with focused ion beam milling showed not only the presence of the ALD coating at the CrN defects but also the opening of new pathways for the corrosion to attack the substrate. A mechanism for the effect of wear on the structure and corrosion protection of hybrid PVD/ALD coatings is proposed on the basis of this investigation.

12.
Biosens Bioelectron ; 118: 23-30, 2018 Oct 30.
Artículo en Inglés | MEDLINE | ID: mdl-30055416

RESUMEN

Unmodified and multi-walled carbon nanotube (MWCNT) modified tetrahedral amorphous carbon (ta-C) films of 15 and 50 nm were investigated as potential in vivo sensor materials for the detection of dopamine (DA) in the presence of the main interferents, ascorbic acid (AA) and uric acid (UA). The MWCNTs were grown directly on ta-C by chemical vapor deposition (designated as ta-C+CNT) and were characterized with X-ray photoelectron spectroscopy, Raman spectroscopy, scanning and transmission electron microscopy. Electroanalytical sensitivity and selectivity were determined with cyclic voltammetry. Biocompatibility of the materials was assessed with cell cultures of mouse neural stem cells (mNSCs). The detection limits of DA for both ta-C and ta-C+CNT electrodes ranged from 40 to 85 nM, which are well within the required range for in vivo detection. The detection limits were lower for both ta-C and ta-C+CNT electrodes with 50 nm of ta-C compared to 15 nm. The ta-C electrodes showed a large dynamic linear range of 0.01-100 µM but could not resolve between the oxidation peaks of DA, AA and UA. Modification with MWCNTs, however, resulted in excellent selectivity and all three analytes could be detected simultaneously at physiologically relevant concentrations using cyclic voltammetry. Based on cell culture of mNSCs, both ta-C and ta-C+CNT exhibited good biocompatibility, demonstrating their potential as in vivo sensor materials for the detection of DA.


Asunto(s)
Técnicas Biosensibles/métodos , Carbono/química , Dopamina/análisis , Nanotubos de Carbono/química , Animales , Ácido Ascórbico , Electrodos , Ratones , Ácido Úrico
13.
Phys Rev Lett ; 120(16): 166101, 2018 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-29756912

RESUMEN

We study the deposition of tetrahedral amorphous carbon (ta-C) films from molecular dynamics simulations based on a machine-learned interatomic potential trained from density-functional theory data. For the first time, the high sp^{3} fractions in excess of 85% observed experimentally are reproduced by means of computational simulation, and the deposition energy dependence of the film's characteristics is also accurately described. High confidence in the potential and direct access to the atomic interactions allow us to infer the microscopic growth mechanism in this material. While the widespread view is that ta-C grows by "subplantation," we show that the so-called "peening" model is actually the dominant mechanism responsible for the high sp^{3} content. We show that pressure waves lead to bond rearrangement away from the impact site of the incident ion, and high sp^{3} fractions arise from a delicate balance of transitions between three- and fourfold coordinated carbon atoms. These results open the door for a microscopic understanding of carbon nanostructure formation with an unprecedented level of predictive power.

14.
Anal Chem ; 90(2): 1408-1416, 2018 01 16.
Artículo en Inglés | MEDLINE | ID: mdl-29218983

RESUMEN

A significant problem with implantable sensors is electrode fouling, which has been proposed as the main reason for biosensor failures in vivo. Electrochemical fouling is typical for dopamine (DA) as its oxidation products are very reactive and the resulting polydopamine has a robust adhesion capability to virtually all types of surfaces. The degree of DA fouling of different carbon electrodes with different terminations was determined using cyclic voltammetry (CV) and scanning electrochemical microscopy (SECM) approach curves and imaging. The rate of electron transfer kinetics at the fouled electrode surface was determined from SECM approach curves, allowing a comparison of insulating film thickness for the different terminations. SECM imaging allowed the determination of different morphologies, such as continuous layers or islands, of insulating material. We show that heterogeneous modification of carbon electrodes with carboxyl-amine functionalities offers protection against formation of an insulating polydopamine layer, while retaining the ability to detect DA. The benefits of the heterogeneous termination are proposed to be due to the electrostatic repulsion between amino-functionalities and DA. Furthermore, we show that the conductivity of the surfaces as well as the response toward DA was recovered close to the original performance level after cleaning the surfaces for 10-20 cycles in H2SO4 on all materials but pyrolytic carbon (PyC). The recovery capacity of the PyC electrode was lower, possibly due to stronger adsorption of DA on the surface.


Asunto(s)
Técnicas Biosensibles/instrumentación , Carbono/química , Dopamina/análisis , Técnicas Electroquímicas/instrumentación , Adsorción , Aminación , Electrodos Implantados , Indoles/análisis , Oxidación-Reducción , Polímeros/análisis , Propiedades de Superficie
15.
RSC Adv ; 8(23): 12742-12751, 2018 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-35541272

RESUMEN

Removal of left-over catalyst particles from carbon nanomaterials is a significant scientific and technological problem. Here, we present the physical and electrochemical study of application-specific carbon nanofibers grown from Pt-catalyst layers. The use of Pt catalyst removes the requirement for any cleaning procedure as the remaining catalyst particles have a specific role in the end-application. Despite the relatively small amount of Pt in the samples (7.0 ± 0.2%), they show electrochemical features closely resembling those of polycrystalline Pt. In O2-containing environment, the material shows two separate linear ranges for hydrogen peroxide reduction: 1-100 µM and 100-1000 µM with sensitivities of 0.432 µA µM-1 cm-2 and 0.257 µA µM-1 cm-2, respectively, with a 0.21 µM limit of detection. In deaerated solution, there is only one linear range with sensitivity 0.244 µA µM-1 cm-2 and 0.22 µM limit of detection. We suggest that the high sensitivity between 1 µM and 100 µM in solutions where O2 is present is due to oxygen reduction reaction occurring on the CNFs producing a small additional cathodic contribution to the measured current. This has important implications when Pt-containing sensors are utilized to detect hydrogen peroxide reduction in biological, O2-containing environment.

16.
RSC Adv ; 8(46): 26356-26363, 2018 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-35541961

RESUMEN

Iron-doped tetrahedral amorphous carbon thin films (Fe/ta-C) were deposited with varying iron content using a pulsed filtered cathodic vacuum arc system (p-FCVA). The aim of this study was to understand effects of iron on both the physical and electrochemical properties of the otherwise inert sp3-rich ta-C matrix. As indicated by X-ray photoelectron spectroscopy (XPS), even ∼0.4 at% surface iron had a profound electrochemical impact on both the potential window of ta-C in H2SO4 and KOH, as well as pseudocapacitance. It also substantially enhanced the electron transport and re-enabled facile outer sphere redox reaction kinetics in comparison to un-doped ta-C, as measured with electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) using outer-sphere probes Ru(NH3)6, IrCl6, and FcMeOH. These increases in surface iron loading were linked to increased surface oxygen content and iron oxides. Unlike few other metals, an iron content even up to 10 at% was not found to result in the formation of sp2-rich amorphous carbon films as investigated by Raman spectroscopy. Atomic force microscopy (AFM) and transmission electron microscopy (TEM) investigations found all films to be amorphous and ultrasmooth with R q values always in the range of 0.1-0.2 nm. As even very small amounts of Fe were shown to dominate the electrochemistry of ta-C, implications of this study are very useful e.g. in carbon nanostructure synthesis, where irregular traces of iron can be readily incorporated into the final structures.

17.
RSC Adv ; 8(62): 35802-35812, 2018 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-35547905

RESUMEN

Application-specific carbon nanofibers grown from Pt-catalyst layers have been shown to be a promising material for biosensor development. Here we demonstrate immobilization of glutamate oxidase on them and their use for amperometric detection of glutamate at two different potentials. At -0.15 V vs. Ag/AgCl at concentrations higher than 100 µM the oxygen reduction reaction severely interferes with the enzymatic production of H2O2 and consequently affects the detection of glutamate. On the other hand, at 0.6 V vs. Ag/AgCl enzyme saturation starts to affect the measurement above a glutamate concentration of 100 µM. Moreover, we suggest here that glutamate itself might foul Pt surfaces to some degree, which should be taken into account when designing Pt-based sensors operating at high anodic potentials. Finally, the Pt-grown and Ni-grown carbon nanofibers were shown to be biocompatible. However, the cells on Pt-grown carbon nanofibers had different morphology and formation of filopodia compared to those on Ni-grown carbon nanofibers. The effect was expected to be caused rather by the different fiber dimensions between the samples than the catalyst metal itself. Further experiments are required to find the optimal dimensions of CNFs for biological purposes.

18.
Eur J Oral Sci ; 125(6): 495-503, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-28921710

RESUMEN

The non-stick properties of thin-film coatings on dental-restorative instruments were investigated by static contact-angle measurement using dental filler resin as well as by scanning electron microscopy of the amount of sticking dental restorative material. Furthermore, using a customized dipping measurement set-up, non-stick properties were evaluated by measuring force-by-time when the instrument was pulled out of restorative material. Minor improvements in non-stick properties were obtained with commercial diamond-like carbon and commercial polytetrafluoroethylene-based coatings. Major improvements were obtained with an in-house fabricated superhydrophobic coating prepared by a multistep process consisting of surface microstructuring by etching in hydrogen fluoride (HF): hydrogen peroxide (H2 O2 ) (1:1; vol/vol), atomic layer deposition of a 7 nm coating of aluminium oxide and titanium oxide, and a self-assembled monolayer of fluorinated organosilicon. Superhydrophobic coatings provide a possible future solution to prevent unwanted adnerence of composite restorative material to dental instruments.


Asunto(s)
Materiales Biocompatibles Revestidos/química , Instrumentos Dentales , Diseño de Equipo , Resinas Sintéticas/química , Grabado Ácido Dental , Óxido de Aluminio/química , Ácido Fluorhídrico/química , Peróxido de Hidrógeno/química , Interacciones Hidrofóbicas e Hidrofílicas , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Politetrafluoroetileno/química , Acero Inoxidable/química , Propiedades de Superficie , Titanio/química
19.
ACS Omega ; 2(2): 496-507, 2017 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-30023609

RESUMEN

Complete removal of metal catalyst particles from carbon nanofibers (CNFs) and other carbon nanostructures is extremely difficult, and the envisioned applications may be compromised by the left-over impurities. To circumvent these problems, one should use, wherever possible, such catalyst materials that are meant to remain in the structure and have some application-specific role, making any removal steps unnecessary. Thus, as a proof-of-concept, we present here a nanocarbon-based material platform for electrochemical hydrogen peroxide measurement utilizing a Pt catalyst layer to grow CNFs with intact Pt particles at the tips of the CNFs. Backed by careful scanning transmission electron microscopy analysis, we show that this material can be readily realized with the Pt catalyst layer thickness impacting the resulting structure and also present a growth model to explain the evolution of the different types of structures. In addition, we show by electrochemical analysis that the material exhibits characteristic features of Pt in cyclic voltammetry and it can detect very small amounts of hydrogen peroxide with very fast response times. Thus, the present sensor platform provides an interesting electrode material with potential for biomolecule detection and in fuel cells and batteries. In the wider range, we propose a new approach where the selection of catalytic particles used for carbon nanostructure growth is made so that (i) they do not need to be removed and (ii) they will have essential role in the final application.

20.
Biosens Bioelectron ; 88: 273-282, 2017 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-27567263

RESUMEN

We hypothesize that by using integrated carbon nanostructures on tetrahedral amorphous carbon (ta-C), it is possible to take the performance and characteristics of these bioelectrodes to a completely new level. The integrated carbon electrodes were realized by combining nanodiamonds (NDs) with ta-C thin films coated on Ti-coated Si-substrates. NDs were functionalized with mixture of carboxyl and amine groups NDandante or amine NDamine, carboxyl NDvox or hydroxyl groups NDH and drop-casted or spray-coated onto substrate. By utilizing these novel structures we show that (i) the detection limit for dopamine can be improved by two orders of magnitude [from 10µM to 50nM] in comparison to ta-C thin film electrodes and (ii) the coating method significantly affects electrochemical properties of NDs and (iii) the ND coatings selectively promote cell viability. NDandante and NDH showed most promising electrochemical properties. The viability of human mesenchymal stem cells and osteoblastic SaOS-2 cells was increased on all ND surfaces, whereas the viability of mouse neural stem cells and rat neuroblastic cells was improved on NDandante and NDH and reduced on NDamine and NDvox. The viability of C6 cells remained unchanged, indicating that these surfaces will not cause excess gliosis. In summary, we demonstrated here that by using functionalized NDs on ta-C thin films we can significantly improve sensitivity towards dopamine as well as selectively promote cell viability. Thus, these novel carbon nanostructures provide an interesting concept for development of various in vivo targeted sensor solutions.


Asunto(s)
Técnicas Biosensibles/métodos , Carbono/química , Dopamina/análisis , Técnicas Electroquímicas/métodos , Nanodiamantes/química , Animales , Línea Celular , Supervivencia Celular , Electrodos , Humanos , Límite de Detección , Ratones , Nanodiamantes/ultraestructura , Nanoestructuras/química , Nanoestructuras/ultraestructura , Ratas , Silicio/química , Propiedades de Superficie , Titanio/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...