Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38970599

RESUMEN

BACKGROUND: Idiopathic ventricular fibrillation (IVF) can be associated with undetected distinct conditions such as microstructural cardiomyopathic alterations (MiCM) or Purkinje (Purk) activities with structurally normal hearts. OBJECTIVE: This study sought to evaluate the characteristics of recurrent VF recorded on implantable defibrillator electrograms, associated with these substrates. METHODS: This was a multicenter collaboration study. At 32 centers, we selected patients with an initial diagnosis of IVF and recurrent arrhythmia at follow-up without antiarrhythmic drugs, in whom mapping demonstrated Purk or MiCM substrate. We analyzed variables related to previous ectopy, sinus rate preceding VF, trigger, and initial VF cycle lengths. Logistic regression with cross validation was used to evaluate the performance of criteria to discriminate Purk or MiCM substrates. RESULTS: Among 95 patients (35 women, age 35 ± 11 years) meeting the inclusion criteria, IVF was associated with MiCM in 41 and Purk in 54 patients. A total of 117 arrhythmia recurrences including 91% VF were recorded on defibrillator. Three variables were mostly discriminant. Sinus tachycardia (≤570 ms) was more frequent in MiCM (35.9% vs 13.4%, P = 0.014) whereas short-coupled (<350 ms) triggers were most frequent in Purk-related VF (95.5% vs 23.1%, P = 0.001), which also had shorter VFCLs (182 ± 15 ms vs 215 ± 24 ms, P < 0.001).The multivariable combination provided the highest prediction (accuracy = 0.93 ± 0.05, range 0.833-1.000), discriminating 81% of IVF substrates with a high probability (>80%). Ectopy were inconsistently present before VF. CONCLUSIONS: Characteristics of arrhythmia recurrences on implantable cardioverter- defibrillator provide phenotypic markers of the distinct and hidden substrates underlying IVF. These findings have significant clinical and genetic implications.

2.
Circ Arrhythm Electrophysiol ; 15(9): e010955, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-36074658

RESUMEN

BACKGROUND: Stereotactic body radiotherapy (SBRT) has been reported as a safe and efficient therapy for treating refractory ventricular tachycardia (VT) despite optimal medical treatment and catheter ablation. However, data on the use of SBRT in patients with electrical storm (ES) is lacking. The aim of this study was to assess the clinical outcomes associated with SBRT in the context of ES. METHODS: This retrospective study included patients who underwent SBRT in the context of ES from March 2020 to March 2021 in one tertiary center (CHU Lille). The target volume was delineated according to a predefined workflow. The efficacy was assessed with the following end points: sustained VT recurrence, VT reduced with antitachycardia pacing, and implantable cardioverter defibrillator shock. RESULTS: Seventeen patients underwent SBRT to treat refractory VT in the context of ES (mean 67±12.8 age, 59% presenting ischemic heart disease, mean left ventricular ejection fraction: 33.7± 9.7%). Five patients presented with ES related to incessant VT. Among these 5 patients, the time to effectiveness ranged from 1 to 7 weeks after SBRT. In the 12 remaining patients, VT recurrences occurred in 7 patients during the first 6 weeks following SBRT. After a median 12.5 (10.5-17.8) months follow-up, a significant reduction of the VT burden was observed beyond 6 weeks (-91% [95% CI, 78-103]), P<0.0001). The incidence of implantable cardioverter defibrillator shock and antitachycardia pacing was 36% at 1 year. CONCLUSIONS: SBRT is associated with a significant reduction of the VT burden in the event of an ES; however, prospective randomized control trials are needed. In patients without incessant VT, recurrences are observed in half of patients during the first 6 weeks. VT tolerance and implantable cardioverter defibrillator programming adjustments should be integrated as part of an action plan defined before SBRT for each patient.


Asunto(s)
Ablación por Catéter , Desfibriladores Implantables , Taquicardia Ventricular , Ablación por Catéter/efectos adversos , Desfibriladores Implantables/efectos adversos , Humanos , Estudios Prospectivos , Recurrencia , Estudios Retrospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/radioterapia , Taquicardia Ventricular/cirugía , Resultado del Tratamiento
3.
Arch Cardiovasc Dis ; 114(4): 287-292, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33526375

RESUMEN

BACKGROUND: Reversion of an implantable cardioverter defibrillator (ICD) to back-up mode degrades the operating capabilities of the device, puts patients at risk and requires rapid intervention by a manufacturer's technician. AIM: To illustrate the usefulness of remote monitoring of ICDs for the early detection of reversion to back-up mode. METHODS: In our centre, all patients implanted with an ICD, with or without resynchronisation, were offered remote monitoring as soon as the technology became available. Alerts triggered by the remote monitoring system were included prospectively in a register. During a mean follow-up of 5.7±1.3 years, a total of 1594 patients with an ICD (441 with resynchronisation function) followed with remote monitoring were included in the register. RESULTS: Among 15,874 alerts, only 10 were related to a reversion to back-up mode. Among those, seven reversions were caused by radiotherapy, two were fake events and one was caused by magnetic resonance imaging. Except for the two fake events, the eight other patients had an emergency admission for the resetting and reprogramming of their ICD. None of the reversion to back-up mode alerts was followed by a clinical alert (i.e. a shock alert) before the ICD problem was resolved. CONCLUSIONS: Reversion to back-up mode is a very rare event, accounting for 0.06% of total alerts; remote monitoring facilitates the early detection of this critical event to resolve the problem faster than the next scheduled follow-up. Remote monitoring can prevent serious damage to the patient and avoids systematic ambulatory control of the ICD after each radiotherapy session.


Asunto(s)
Arritmias Cardíacas/terapia , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Insuficiencia Cardíaca/terapia , Falla de Prótesis , Tecnología de Sensores Remotos , Telemedicina , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Diagnóstico Precoz , Cardioversión Eléctrica/efectos adversos , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
4.
J Electrocardiol ; 63: 6-11, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33011474

RESUMEN

OBJECTIVES: To determine the prognostic value of a low T/R ratio, defined as the amplitude ratio between the T waves and the R waves, in patients (pts) with a spontaneous type-1 Brugada pattern (SBT1). BACKGROUND: Abnormalities of myocardial repolarization may play a key role in the initiation of ventricular fibrillation (VF) in Brugada syndrome (BrS). Recent studies have shown that the height of the T waves and the T/R ratio are inversely proportional to sudden cardiac arrest (SCA) risk in early repolarization syndrome and hypertrophic cardiomyopathy. METHODS: In an international retrospective study, we reviewed 115 pts. (105 males, 91.3%). 45 had VF and/or SCA (38.7 ±â€¯11.5 years old, all males), while 70 (49.3 ±â€¯12.0 years, 10 women) remained free of ventricular arrhythmia. 6 ECG markers plus the T/R ratio in leads V5 & II were studied. RESULTS: The T/R ratio among leads II & V5 was significantly lower in the VF/SCA group (0.24 [0.14; 0.38]vs. 0.34 [0.24; 0.45]; p = 0.006). 44.4% of pts. in the VF/SCA group had a lowest T/R ratio among leads II & V5 ≤ 0.17 compared to 11.4% in the non-VF/SCA group (p < 0.001). In multivariate analysis, a lowest T/R ratio among leads II & V5 ≤ 0.17 was independently associated with VF/SCA (OR 6.10, 95% CI 1.92-19.40; p = 0.002). Type 1 Brugada pattern in the peripheral leads (OR 10.78) and early repolarization (OR 3.60) were other independent markers of VF/SCA. CONCLUSION: A low T/R ratio among leads II & V5 is an independent marker for VF/SCA risk in patients with type-1 Brugada pattern.


Asunto(s)
Síndrome de Brugada , Adulto , Síndrome de Brugada/diagnóstico , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Fibrilación Ventricular/diagnóstico
5.
Europace ; 21(9): 1400-1409, 2019 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-31177270

RESUMEN

AIMS: There is currently no reliable tool to quantify the risks of ventricular fibrillation or sudden cardiac arrest (VF/SCA) in patients with spontaneous Brugada type 1 pattern (BrT1). Previous studies showed that electrocardiographic (ECG) markers of depolarization or repolarization disorders might indicate elevated risk. We aimed to design a VF/SCA risk prediction model based on ECG analyses for adult patients with spontaneous BrT1. METHODS AND RESULTS: This retrospective multicentre international study analysed ECG data from 115 patients (mean age 45.1 ± 12.8 years, 105 males) with spontaneous BrT1. Of these, 45 patients had experienced VF/SCA and 70 patients did not experience VF/SCA. Among 10 ECG markers, a univariate analysis showed significant associations between VF/SCA and maximum corrected Tpeak-Tend intervals ≥100 ms in precordial leads (LMaxTpec) (P < 0.001), BrT1 in a peripheral lead (pT1) (P = 0.004), early repolarization in inferolateral leads (ER) (P < 0.001), and QRS duration ≥120 ms in lead V2 (P = 0.002). The Cox multivariate analysis revealed four predictors of VF/SCA: the LMaxTpec [hazard ratio (HR) 8.3, 95% confidence interval (CI) 2.4-28.5; P < 0.001], LMaxTpec + ER (HR 14.9, 95% CI 4.2-53.1; P < 0.001), LMaxTpec + pT1 (HR 17.2, 95% CI 4.1-72; P < 0.001), and LMaxTpec + pT1 + ER (HR 23.5, 95% CI 6-93; P < 0.001). Our multidimensional penalized spline model predicted the 1-year risk of VF/SCA, based on age and these markers. CONCLUSION: LMaxTpec and its association with pT1 and/or ER indicated elevated VF/SCA risk in adult patients with spontaneous BrT1. We successfully developed a simple risk prediction model based on age and these ECG markers.


Asunto(s)
Síndrome de Brugada/fisiopatología , Muerte Súbita Cardíaca/epidemiología , Electrocardiografía , Fibrilación Ventricular/epidemiología , Adulto , Factores de Edad , Síndrome de Brugada/complicaciones , Muerte Súbita Cardíaca/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Fibrilación Ventricular/etiología
6.
Pacing Clin Electrophysiol ; 42(3): 349-355, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30609077

RESUMEN

INTRODUCTION: Several clinical studies have demonstrated that remote monitoring (RM) offers potential benefits in transvenous implantable cardioverter defibrillator (ICD). The potential interest of RM in subcutaneous-ICD (S-ICD) recipients has never been evaluated. The aim of this study was to evaluate the alert burden and its clinical relevance in a prospective cohort of S-ICD recipients. METHODS: We prospectively and consecutively enrolled all patients undergoing S-ICD implantation at Lille University Hospital from September 2015 to January 2017 and gave them a LATITUDE™ NXT RM system. The relevance of transmissions was assessed by the following ratio: number of transmissions leading to reaction or intervention per patient/number of transmissions per patient. RESULTS: From September 2015 to January 2017, 69 patients were enrolled with a mean follow-up of 415 ± 96.3 days. The mean age was 44.6 ± 15.6 years old, and 25% (n = 17) had ischemic cardiomyopathy. At the end of follow-up, 12% of the patients had events recorded by RM. These events were related to nine ICD shocks and eight untreated events. A total of 1,423 transmissions were collected. Most of these transmissions were patient-initiated without any event (77%, n = 1,096) or scheduled without any event (19%, n = 272). Only 3.2% ± 1.1 of the transmissions per patient led to reactions or interventions. CONCLUSION: On the basis of the current method of transmitting, S-ICD RM allowed detection of relevant events in 12% of patients but generated a high unactionable transmission burden. As a result of these findings, efforts should be made to optimize transmissions considering automatic transmissions and to focus on patient education.


Asunto(s)
Cardiomiopatías/terapia , Desfibriladores Implantables , Tecnología de Sensores Remotos/métodos , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sistema de Registros
7.
Arch Cardiovasc Dis ; 112(2): 82-94, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30600217

RESUMEN

BACKGROUND: Convulsive syncope and epileptic seizure share many similar clinical features. Early diagnosis is critical for choosing the appropriate management strategy. AIM: Our aim was to evaluate the diagnostic yield of an innovative diagnostic strategy - combined head-up tilt test (HUT)/video electroencephalogram (EEG) monitoring - in patients with unexplained seizure-like transient loss of consciousness (T-LOC). METHODS: Combined HUT/video EEG was performed in patients with unexplained atypical T-LOC with both syncope and seizure characteristics remaining undiagnosed after a first-line investigation. T-LOC diagnosis was achieved in case of reproduction of usual symptoms. Events were classified as vasovagal, psychogenic or epilepsy. The link between EEG abnormalities and T-LOC was determined by an epilepsy specialist. Clinical follow-up was performed to assess T-LOC recurrence. RESULTS: Hundred and one consecutive patients were prospectively enrolled (median age 26 [19; 46] years; 72% female) and underwent combined HUT/video EEG between 2007 and 2015. Antiepileptic drugs were being prescribed in 42% of patients. Combined HUT/video EEG was diagnostic in 67% of patients, leading to diagnosis of vasovagal syncope in 59 patients and psychogenic pseudosyncope in nine cases. Antiepileptic drugs were discontinued in 18 patients without epilepsy. Independent predictors of a definitive diagnosis were the presence of prodromal symptoms (odds ratio 5.97, 95% confidence interval 1.37-26; P=0.017) and a history of myoclonic jerks during T-LOC (odds ratio 4.36, 95% confidence interval 1.71-11.15; P=0.002). CONCLUSIONS: Combined HUT/video EEG is useful for investigating recurrent unexplained atypical seizure-like T-LOC, especially in patients with a history of myoclonic jerks or with documented interictal non-specific EEG abnormalities.


Asunto(s)
Ondas Encefálicas , Encéfalo/fisiopatología , Electroencefalografía/métodos , Posicionamiento del Paciente , Convulsiones/diagnóstico , Síncope/diagnóstico , Pruebas de Mesa Inclinada , Inconsciencia/etiología , Grabación en Video , Adulto , Anticonvulsivantes/uso terapéutico , Encéfalo/efectos de los fármacos , Ondas Encefálicas/efectos de los fármacos , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Convulsiones/complicaciones , Convulsiones/tratamiento farmacológico , Convulsiones/fisiopatología , Síncope/complicaciones , Síncope/fisiopatología , Inconsciencia/fisiopatología , Adulto Joven
11.
Arch Cardiovasc Dis ; 109(10): 517-526, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27342808

RESUMEN

BACKGROUND: Little is known about the long-term outcomes of patients who receive an implantable cardioverter-defibrillator (ICD) for purely secondary prevention indications. AIMS: To assess the rates and predictors of appropriate therapies over a very long-term follow-up period in this population. METHODS: Between June 2003 and August 2006, 239 consecutive patients with structural left ventricular disease and a secondary prophylaxis indication for ICD therapy (survivors of life-threatening ventricular tachyarrhythmias) were prospectively enrolled. An extended follow-up of these patients was carried out. The primary endpoint was the occurrence of appropriate device therapy. Secondary endpoints were all-cause death, electrical storm and inappropriate therapy. RESULTS: The study population consisted of 239 patients (90% men; mean age 64±12 years; 72% ischaemic cardiomyopathy; left ventricular ejection fraction 37±12%). During a median follow-up of 7.8 (3.5-9.3) years, appropriate device therapy occurred in 139 (58.2%) patients. Death occurred in 141 patients (59%), electrical storm in 73 (30.5%) and inappropriate therapy in 42 (17.6%). Multivariable analysis identified patients whose presenting arrhythmia was ventricular fibrillation as being less likely to require appropriate device therapy than those whose presenting arrhythmia was ventricular tachycardia (sub-hazard ratio 0.62, 95% confidence interval 0.40-0.97; P=0.04). Independent predictors of all-cause death were age at implantation (P<0.0001), wide QRS complexes (P=0.024), creatinine concentration (P=0.0002) and B-type natriuretic peptide at implantation (P=0.0001). CONCLUSION: Secondary prevention ICD recipients exhibit a high risk of appropriate device therapy and death over prolonged follow-up. Patients who presented initially with ventricular fibrillation were less likely to require the delivery of appropriate device therapy.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Prevención Secundaria/métodos , Taquicardia Ventricular/terapia , Adulto , Anciano , Anciano de 80 o más Años , Muerte Súbita Cardíaca/etiología , Electrocardiografía , Femenino , Estudios de Seguimiento , Francia/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia/tendencias , Taquicardia Ventricular/mortalidad , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Adulto Joven
12.
Europace ; 18(6): 820-7, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26498163

RESUMEN

AIMS: Lead fractures in implantable cardioverter-defibrillator (ICD) patients may cause inappropriate shocks (ISs). An early diagnosis is essential to prevent adverse clinical events. Implantable cardioverter-defibrillator remote monitoring (RM) permits prompt detection of lead fracture. Limited data define the impact of RM on ISs specifically related to lead fracture. We sought to compare the number of ISs related to lead fracture in patients with vs. without RM follow-up. METHODS AND RESULTS: We checked the registry of our institution and collected, between July 2007 and June 2014, 115 cases of right ventricular lead fractures. All relevant data were documented from patients' files, device-interrogation printouts and electronic records, and remote transmissions databases when applicable. We assessed the ISs that were related to lead fracture. The first study endpoint was the number of ISs per shocked patient. Among the 82 patients with conventional follow-up (CFU) and the 33 patients with RM, a first IS occurred to 32.9% (n = 27) and 30.3% (n = 10, P = 0.83) of the patients, respectively. Shocked patients in the RM group underwent significantly fewer ISs with a mean of 6 ± 2 shocks per patient [median of 3.5 shocks (2-8)] than those in the CFU group with a mean of 18 ± 5 shocks per patient [median of 10 shocks (5-22), P = 0.03]. CONCLUSION: Remote monitoring helps to reduce the burden of ISs related to ICD lead fractures.


Asunto(s)
Desfibriladores Implantables/efectos adversos , Cardioversión Eléctrica/efectos adversos , Falla de Equipo , Tecnología de Sensores Remotos , Femenino , Estudios de Seguimiento , Francia , Humanos , Masculino , Persona de Mediana Edad , Sistema de Registros
13.
Europace ; 18(12): 1809-1817, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26711741

RESUMEN

AIMS: Despite increased use of remote monitoring (RM) to follow up implantable cardioverter-defibrillator (ICD) recipients, many patients still receive ICD shocks in the community and present to the emergency department. Our aim was to identify the best predictors of impending shock delivery that can be measured with an ICD and to identify the most appropriate activities to alert physicians to during RM follow-up. METHODS AND RESULTS: All patients presenting to our institution for ICD shock, from November 2011 to November 2014, were enrolled in this prospective study. Patient characteristics, investigation results, and details of electrical activities from ICD interrogation were recorded at presentation. Presentations were classified as potentially avoidable if activities from a list of set criteria were apparent more than 48 h before index shock. Univariate and multivariate analyses were then used to identify predictors of potentially avoidable shocks. In total, 109 emergency presentations were recorded in 90 patients (male: 85%; 57 ± 16 years; ischaemic cardiomyopathy: 49%; LVEF: 34 ± 13%; electrical storm: 40%), of which 26 (24%) were potentially avoidable. Antitachycardia pacing (ATP) episodes were the most important predictor of impending shock. Potentially avoidable shocks were preceded by more episodes of ATP than unavoidable shocks (13 [3-67] vs. 3 [0-10]; P < 0.001). Patients followed up with RM systems configured to generate alerts following ATP delivery experienced significantly less ICD shocks (24 vs. 16%, P < 0.01). CONCLUSION: Remote monitoring systems that generate alerts following ATP delivery could reduce emergency presentations for ICD shock by 24%, as ATP is a key predictor of impending shock delivery.


Asunto(s)
Estimulación Cardíaca Artificial/efectos adversos , Desfibriladores Implantables , Cardioversión Eléctrica/efectos adversos , Tecnología de Sensores Remotos , Taquicardia Ventricular/terapia , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Cardioversión Eléctrica/instrumentación , Electrocardiografía , Servicios Médicos de Urgencia , Femenino , Francia , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico/métodos , Análisis Multivariante , Isquemia Miocárdica/epidemiología , Isquemia Miocárdica/etiología , Estudios Prospectivos , Telemedicina , Disfunción Ventricular Izquierda/epidemiología , Disfunción Ventricular Izquierda/etiología , Adulto Joven
14.
Europace ; 18(6): 919-24, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26293624

RESUMEN

AIMS: Implantable cardiac monitors (ICMs) are used for long-term heart rhythm monitoring, e.g. to diagnose unexplained syncope or for detection of suspected atrial and ventricular arrhythmias. The newest ICM, Reveal LINQ™ (Medtronic Inc.), is miniaturized and inserted with a specific insertion tool kit. The procedure is therefore minimally invasive and can be moved from catheterization laboratory (cath lab) to a less resource intensive setting. This study aims to assess the change in procedure costs when performed outside the cath lab. METHODS AND RESULTS: A bottom-up costing methodology was used. Data were collected from interviews with physicians, cath lab managers, and financial controllers. Hospitals in the Netherlands, France, and the UK were included in this study. The cost comparison of a Reveal XT implantation in a cath lab setting vs. a Reveal LINQ insertion outside a cath lab resulted in an estimated reduction of €662 for the UK, €682 for the Netherlands, and €781 for France. These cost savings were primarily realized through fewer staff, less equipment, and overhead costs. The net effect on savings depends on the price differential between these two technologies. The patient care pathway can be improved due to the possibility to move the procedure out of the cath lab. CONCLUSION: Inserting the miniaturized version of the ICM is simpler and faster, and the procedure can take place outside the cath lab in a less resource intensive environment. Hospitals save resources when the higher price of the Reveal LINQ does not outweigh these savings.


Asunto(s)
Arritmias Cardíacas/complicaciones , Arritmias Cardíacas/diagnóstico , Electrocardiografía Ambulatoria/economía , Electrodos Implantados/economía , Síncope/etiología , Costos y Análisis de Costo , Electrocardiografía Ambulatoria/instrumentación , Francia , Hospitales , Humanos , Países Bajos , Reino Unido
15.
Circ Cardiovasc Qual Outcomes ; 8(4): 403-12, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26105725

RESUMEN

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) are a standard means of sudden cardiac death prevention. Compared with ambulatory visits, remote monitoring (RM) of ICD recipients has improved the quality of health care and spared its resources. Few studies have addressed the organization of RM. We optimized and validated our institutional model of RM organization for ICD recipients. METHODS AND RESULTS: This observational study of 562 ICD recipients compared 2 RM periods consisting of iterative, qualitative, and quantitative (1) device diagnostic evaluations by nurses and cardiologists; and (2) selected decisional trees. The main study end points were the professional interventions prompted by, and times allocated to, RM alerts. During the first period, 1134 alerts occurred in 427 patients (286 patient-year), of which 376 (33%) were submitted to cardiologists' reviews, compared with, 1522 alerts in 562 patients (458 patient-year), of which 273 (18%) were submitted to cardiologists' reviews during the second period (P<0.001). An intervention was prompted by 73 of 376 (19.4%) alerts in the first versus 77 of 273 (28.2%) in the second period (P=0.009). The mean time to manage an alert was 4 minutes 31 s in the first versus 2 minutes 10 s in the second period (P<0.001). The annual numbers of alert-related hospitalizations were 10.8 versus 8.1 per 100-patient-year (P=0.230), and annual numbers of alert-related visits were 9.8 and 6.1 per 100-patient-year (P=0.081), respectively. CONCLUSIONS: An optimized RM organization based on automated alerts and decisional trees enabled a focus on clinically relevant events and a decrease in the consumption of resources without compromising the quality of ICD recipients' care.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Manejo de la Enfermedad , Insuficiencia Cardíaca/terapia , Modelos Organizacionales , Monitoreo Fisiológico/métodos , Telemedicina/métodos , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/fisiopatología , Hospitalización/tendencias , Humanos , Masculino , Persona de Mediana Edad , Calidad de Vida , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Tiempo
17.
Arch Cardiovasc Dis ; 107(10): 546-52, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25241220

RESUMEN

BACKGROUND: The role of implantable loop recorders (ILRs) in the evaluation strategy for recurrent syncope in France is limited by lack of knowledge of the cost. AIM: To compare a conventional evaluation strategy for syncope with the early use of an ILR in low-risk patients, in terms of diagnostic yield, cost and impact on quality of life (QoL). METHODS: National prospective randomized open-label multicenter study of patients with a single syncope (if severe and recent) or at least two syncopes in the past year. RESULTS: Seventy-eight patients (32 men) were randomized to the ILR strategy (ILR group, n=39) or the conventional evaluation strategy (CONV group, n=39): mean age 66.2±14.8 years; 4.3±6.4 previous syncopes. After 14 months of follow-up, a certain cause of syncope was established in 18 (46.2%) patients in the ILR group and two (5%) patients in the CONV group (P<0.001). Advanced cardiological tests were performed less frequently in the ILR group than in the CONV group (0.03±0.2 vs. 0.2±0.5 tests per patient; P=0.05). Patients in the ILR group were hospitalized for a non-significantly shorter period than patients in the CONV group (5.7±3.2 vs. 8.0±1.4 days). There was no difference between the two groups in terms of QoL main composite score. CONCLUSION: In patients with unexplained syncope, the early use of an ILR has a superior diagnostic yield compared with the conventional evaluation strategy, with lower healthcare-related costs.


Asunto(s)
Desfibriladores Implantables , Atención a la Salud/métodos , Diagnóstico Precoz , Síncope/terapia , Anciano , Análisis Costo-Beneficio , Atención a la Salud/economía , Electrocardiografía Ambulatoria , Femenino , Estudios de Seguimiento , Francia , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Calidad de Vida , Síncope/diagnóstico , Síncope/economía , Factores de Tiempo
18.
Arch Cardiovasc Dis ; 107(12): 664-71, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25241223

RESUMEN

BACKGROUND: Remote monitoring (RM) is increasingly used to follow up patients with implantable cardioverter-defibrillators (ICDs). Randomized control trials provide evidence for the benefit of this intervention, but data for RM in daily clinical practice with multiple-brands and unselected patients is lacking. AIMS: To assess the effect of RM on patient management and clinical outcome for recipients of ICDs in daily practice. METHODS: We reviewed ICD recipients followed up at our institution in 2009 with RM or with traditional hospital only (HO) follow-up. We looked at the effect of RM on the number of scheduled ambulatory follow-ups and urgent unscheduled consultations, the time between onset of asymptomatic events to clinical intervention and the clinical effectiveness of all consultations. We also evaluated the proportion of RM notifications representing clinically relevant situations. RESULTS: We included 355 patients retrospectively (RM: n=144, HO: n=211, 76.9% male, 60.3±15.2 years old, 50.1% with ICDs for primary prevention and mean left ventricular ejection fraction 35.5±14.5%). Average follow-up was 13.5 months. The RM group required less scheduled ambulatory follow-up consultations (1.8 vs. 2.1/patient/year; P<0.0001) and a far lower median time between the onset of asymptomatic events and clinical intervention (7 vs. 76 days; P=0.016). Of the 784 scheduled ambulatory follow-up consultations carried out, only 152 (19.4%) resulted in therapeutic intervention or ICD reprogramming. We also found that the vast majority of RM notifications (61.9%) were of no clinical relevance. CONCLUSION: RM allows early management of asymptomatic events and a reduction in scheduled ambulatory follow-up consultations in daily clinical practice, without compromising safety, endorsing RM as the new standard of care for ICD recipients.


Asunto(s)
Arritmias Cardíacas/terapia , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Prevención Primaria/instrumentación , Ensayos Clínicos Controlados Aleatorios como Asunto , Telemedicina/métodos , Telemetría , Adulto , Anciano , Atención Ambulatoria , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/fisiopatología , Medicina Basada en la Evidencia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Derivación y Consulta , Estudios Retrospectivos , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda
19.
Can J Cardiol ; 30(6): 606-11, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24882530

RESUMEN

BACKGROUND: For patients presenting with syncope and bundle branch block (BBB), results during electrophysiological studies (EPS) might depend on the electrocardiographic pattern of conduction disturbances. We sought to identify predictors of advanced His-Purkinje conduction disturbances (HPCDs) in these patients. METHODS: In this retrospective multicentre study, patients were included who: (1) presented with unexplained syncope; (2) had BBB (QRS duration ≥ 120 ms); and (3) were investigated with EPS. HPCD was diagnosed if the baseline His-ventricular interval was ≥ 70 ms or if second- or third-degree His-Purkinje block was observed during atrial pacing or pharmacological challenge. RESULTS: Of the 171 patients studied (72 ± 13 years, 64% male sex, mean left ventricular ejection fraction 57 ± 9%), advanced HPCD was found in 73 patients (43%). The following electrocardiographic features were associated with HPCD (P = 0.01): isolated right BBB (34.4%), right BBB with left anterior fascicular block (36.4%), left BBB (46.2%), and right BBB with left posterior fascicular block (LPFB, 78.6%). Multivariate analysis identified first-degree atrioventricular block (odds ratio, 2.4; 95% confidence interval, 1.2-4.7; P = 0.01) and LPFB (odds ratio, 4.8; 95% confidence interval, 1.3-18.5; P = 0.02) as the only 2 independent predictors of advanced HPCD. CONCLUSIONS: For patients presenting with syncope and BBB, first-degree atrioventricular block and LPFB increased the likelihood of finding HPCDs during EPS. However, no single electrocardiographic feature could consistently predict the outcome of EPS, so this investigation is still necessary in assessing the need for pacemaker implantation, irrespective of the precise appearance of abnormalities on ECG.


Asunto(s)
Fascículo Atrioventricular/fisiopatología , Bloqueo de Rama/fisiopatología , Técnicas Electrofisiológicas Cardíacas , Ramos Subendocárdicos/fisiopatología , Síncope/fisiopatología , Anciano , Anciano de 80 o más Años , Bloqueo Atrioventricular/clasificación , Bloqueo Atrioventricular/fisiopatología , Bloqueo Atrioventricular/cirugía , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/cirugía , Desfibriladores Implantables , Electrocardiografía , Femenino , Humanos , Masculino , Análisis Multivariante , Marcapaso Artificial , Estudios Retrospectivos , Volumen Sistólico/fisiología
20.
Europace ; 16(8): 1181-8, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24614572

RESUMEN

AIMS: The Effectiveness and Cost of ICD follow-up Schedule with Telecardiology (ECOST) trial evaluated prospectively the economic impact of long-term remote monitoring (RM) of implantable cardioverter defibrillators (ICDs). METHODS AND RESULTS: The analysis included 310 patients randomly assigned to RM (active group) vs. ambulatory follow-ups (control group). Patients in the active group were seen once a year unless the system reported an event mandating an ambulatory visit, while patients in the control group were seen in the ambulatory department every 6 months. The costs of each follow-up strategy were compared, using the actual billing documents issued by the French health insurance system, including costs of (i) (a) ICD-related ambulatory visits and transportation, (b) other ambulatory visits, (c) cardiovascular treatments and procedures, and (ii) hospitalizations for the management of cardiovascular events. The ICD and RM system costs were calculated on the basis of the device remaining longevity at the end of the study. The characteristics of the study groups were similar. Over a follow-up of 27 months, the mean non-hospital costs per patient-year were €1695 ± 1131 in the active, vs. €1952 ± 1023 in the control group (P = 0.04), a €257 difference mainly due to device management. The hospitalization costs per patient-year were €2829 ± 6382 and €3549 ± 9714 in the active and control groups, respectively (P = 0.46). Adding the ICD to the non-hospital costs, the savings were €494 (P = 0.005) or, when the monitoring system was included, €315 (P = 0.05) per patient-year. CONCLUSION: From the French health insurance perspective, the remote management of ICD patients is cost saving. CLINICAL TRIALS REGISTRATION: NCT00989417, www.clinicaltrials.gov.


Asunto(s)
Atención Ambulatoria/economía , Desfibriladores Implantables/economía , Cardioversión Eléctrica/economía , Costos de la Atención en Salud , Telemedicina/economía , Telemetría/economía , Anciano , Ahorro de Costo , Análisis Costo-Beneficio , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/instrumentación , Femenino , Francia , Gastos en Salud , Costos de Hospital , Humanos , Reembolso de Seguro de Salud , Masculino , Persona de Mediana Edad , Visita a Consultorio Médico/economía , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Factores de Tiempo , Transporte de Pacientes/economía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...