Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Ophthalmologica ; 246(3-4): 219-226, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37271123

RESUMEN

INTRODUCTION: The aim of this study was to determine whether the use of perfluorocarbon liquid (PFCL) affects the rate of retinal re-attachments after an initial attachment by vitrectomy in eyes with rhegmatogenous retinal detachment (RRD). METHODS: This was a retrospective, observational, multicenter study of 3,446 eyes registered in the Japanese vitreoretinal surgery treatment information database. Of these, 2,648 eyes had undergone vitrectomy as the first surgery for RRD. The re-attachment rates after the primary vitrectomy with or without PFCL were evaluated. In addition, the significance of factors affecting the re-detachments was determined by univariate and multivariate analyses. The measured outcomes were the rates of re-attachments after the primary vitrectomy with or without the use of PFCL. RESULTS: A total of 2,362 eyes in the database were analyzed: 325 had and 2,037 did not have PFCL injected into the vitreous cavity during the vitrectomy. The rate of re-attachments was 91.5% in the PFCL group and 93.2% in the non-PFCL group (p = 0.46, χ2 test). Although there were several risk factors associated with the re-detachments in eyes without PFCL (p < 0.05, Welch's t tests, and Fisher's exact tests), they were not associated in eyes with PFCL use. However, multivariate analyses showed that there was no significant association between the use and the non-use of PFCL in the rate of re-detachments (ß = -0.08, p = 0.46). CONCLUSIONS: The use of PFCL during the initial vitrectomy for RRD does not affect the rate of re-attachments.


Asunto(s)
Fluorocarburos , Oftalmología , Desprendimiento de Retina , Humanos , Desprendimiento de Retina/cirugía , Retina , Vitrectomía
2.
J Ophthalmol ; 2016: 1960190, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27867657

RESUMEN

Purpose. To describe a method of quantifying the size of the retinal hemorrhages in branch retinal vein occlusion (BRVO) and to determine the interrater and intrarater reliabilities of these measurements. Methods. Thirty-five fundus photographs from 35 consecutive eyes with BRVO were studied. The fundus images were analyzed with Power-Point® software, and a grid of 14 squares was laid over the fundus image. Raters were asked to judge the percentage of each of the 14 squares that was covered by the hemorrhages, and the average of the 14 squares was taken to be the relative size of the retinal hemorrhage. Results. Interrater reliability between three raters was higher when a grid with 14 squares was used (intraclass correlation coefficient (ICC), 0.96) than that when a box with no grid was used (ICC, 0.78). Intrarater reliability, which was calculated by the retinal hemorrhage area measured on two different days, was also higher (ICC, 0.97) than that with no grid (ICC, 0.86). Interrater reliability for five fundus pictures with poor image quality was also good when a grid with 14 squares was used (ICC, 0.88). Conclusions. Although our method is subjective, excellent interrater and intrarater reliabilities indicate that this method can be adapted for clinical use.

3.
Jpn J Ophthalmol ; 57(3): 320-6, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-22961343

RESUMEN

PURPOSE: The purpose of this study was to determine whether an antivascular endothelium growth factor (VEGF) antibody, a corticosteroid, and sodium nitroprusside (SNP) [a nitric oxide (NO) donor] are possible treatment agents for nonarteritic ischemic optic neuropathy (NAION) by clarifying their effects on high-K (potassium) solution-induced contraction in isolated rabbit and human posterior ciliary arteries (PCA). METHODS: Vascular ring segments were cut from the distal section of the PCA and mounted in a double-myograph system. After obtaining the maximal contraction following the administration of high-K solution, bevacizumab as an anti-VEGF antibody, methylprednisolone as a corticosteroid, and SNP were administered separately. When a vasodilatory effect was observed, carboxy-PTIO (a NO scavenger) or L-NAME (a NO synthase inhibitor) was administered. RESULTS: Bevacizumab did not relax either the rabbit or the human PCA, whereas methylprednisolone relaxed both. Neither carboxy-PTIO nor L-NAME inhibited methylprednisolone-induced relaxation. SNP relaxed the rabbit PCA. Carboxy-PTIO inhibited SNP-induced relaxation, but L-NAME did not. In the human PCA, the vasodilatory effect of SNP was present, but weaker than in the rabbit PCA. CONCLUSIONS: A corticosteroid has NO-independent vasodilatory effects. Exogenous NO has a weak dilating effect in the human PCA. Therefore, corticosteroid could be effective for the treatment of NAION.


Asunto(s)
Corticoesteroides/farmacología , Anticuerpos Monoclonales Humanizados/farmacología , Arterias Ciliares/fisiopatología , Óxido Nítrico/farmacología , Neuropatía Óptica Isquémica/tratamiento farmacológico , Factor A de Crecimiento Endotelial Vascular/análisis , Vasodilatación/efectos de los fármacos , Animales , Bevacizumab , Arterias Ciliares/efectos de los fármacos , Modelos Animales de Enfermedad , Endotelio Vascular/efectos de los fármacos , Endotelio Vascular/fisiopatología , Factores Relajantes Endotelio-Dependientes/farmacología , Humanos , Masculino , Persona de Mediana Edad , Neuropatía Óptica Isquémica/metabolismo , Neuropatía Óptica Isquémica/fisiopatología , Conejos , Factor A de Crecimiento Endotelial Vascular/antagonistas & inhibidores , Vasodilatadores/farmacología
4.
Appl Ergon ; 43(2): 308-19, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21798514

RESUMEN

This paper describes the application of an alternative seating concept for surgeons that reflects the research of Zen sitting postures, which require Zazen meditators to maintain fixed postures for long durations. The aim of this alternative approach is to provide sitters with a seat pan with sacral support(1) that provides a more even distribution of seat pressures, induces forward pelvic rotation and improves lumbar, buttock and thigh support. This approach was applied to the development of a chair for microscopic surgery. The experimental chair is a seat pan that closely matches the three-dimensional contours of the user's buttocks. Seat comfort was evaluated by comparing both changes in pelvic tilt and seat pressure distributions using Regionally-Differentiated Pressure Maps (RDPM) with subjective ratings of surgeons while operating in prototype and conventional chairs. Findings include that the sacral support of the prototype chair prevents backward pelvic rotation, as seen in zazen (Zen sitting postures). Preliminary data suggests that the prototype provided greater sitting comfort and support for constrained operating postures than did the conventional chair. These findings support the selective application of concave-shaped seat pans that conform to users' buttocks and reflect Zen sitting principles.


Asunto(s)
Diseño de Equipo , Microcirugia , Médicos , Postura/fisiología , Adulto , Anciano , Ergonomía , Femenino , Humanos , Diseño Interior y Mobiliario , Masculino , Persona de Mediana Edad , Salud Laboral , Dolor , Pelvis/fisiología , Columna Vertebral/fisiología , Encuestas y Cuestionarios , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...