Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
J. bras. nefrol ; 45(3): 373-377, Sept. 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1521096

RESUMEN

Abstract Introduction: Urinary catheter-related infection is commonly associated with bacterial biofilm. The impact of anaerobes is unknown, but their detection in the biofilm on this device has not been previously reported. This study aimed to evaluate the capability to recovery strict, facultative, and aerobic microorganisms in patients using bladder catheters from ICUs using conventional culture, sonication, urinary analysis, and mass spectrometry. Methods: Parallel, sonicated bladder catheters from 29 critically ill patients were compared with their routine urine culture. Identification was performed using matrix-assisted laser desorption/ionization with time-of-flight mass spectrometry. Results: The positivity rate in urine (n = 2, 3.4%) was lower than that in sonicated catheters (n = 7, 13.8%). Conclusion: Bladder catheter sonication showed more positive culture results than urine samples for anaerobic and aerobic microorganisms. The role of anaerobes in urinary tract infection and catheter biofilm is discussed.


Resumo Introdução: A infecção relacionada ao cateter urinário é comumente associada ao biofilme bacteriano. O impacto dos anaeróbios é desconhecido, mas sua detecção no biofilme deste dispositivo não foi relatada anteriormente. Este estudo teve como objetivo avaliar a capacidade de recuperar microrganismos estritos, facultativos e aeróbios em pacientes que utilizam cateteres vesicais de UTIs utilizando cultura convencional, sonicação, análise urinária e espectrometria de massa. Métodos: Paralelamente, foram comparados cateteres vesicais sonicados de 29 pacientes gravemente enfermos com sua urocultura de rotina. A identificação foi realizada utilizando dessorção/ionização a laser assistida por matriz com espectrometria de massa por tempo de voo. Resultados: A taxa de positividade na urina (n = 2; 3,4%) foi inferior à dos cateteres sonicados (n = 7; 13,8%). Conclusão: A sonicação do cateter vesical apresentou resultados de cultura mais positivos do que as amostras de urina para microrganismos anaeróbios e aeróbios. É discutido o papel dos anaeróbios na infecção do trato urinário e no biofilme do cateter.

2.
Clin Infect Dis ; 77(Suppl 1): S29-S37, 2023 07 05.
Artículo en Inglés | MEDLINE | ID: mdl-37406041

RESUMEN

BACKGROUND: Carbapenemase production is a global public health threat. Antimicrobial resistance (AMR) data analysis is critical to public health policy. Here we analyzed carbapenemase detection trends using the AMR Brazilian Surveillance Network. METHODS: Carbapenemase detection data from Brazilian hospitals included in the public laboratory information system dataset were evaluated. The detection rate (DR) was defined as carbapenemase detected by gene tested per isolate per year. The temporal trends were estimated using the Prais-Winsten regression model. The impact of COVID-19 on carbapenemase genes in Brazil was determined for the period 2015-2022. Detection pre- (October 2017 to March 2020) and post-pandemic onset (April 2020 to September 2022) was compared using the χ2 test. Analyses were performed with Stata 17.0 (StataCorp, College Station, TX). RESULTS: 83 282 blaKPC and 86 038 blaNDM were tested for all microorganisms. Enterobacterales DR for blaKPC and blaNDM was 68.6% (41 301/60 205) and 14.4% (8377/58 172), respectively. P. aeruginosa DR for blaNDM was 2.5% (313/12 528). An annual percent increase for blaNDM of 41.1% was observed, and a decrease for blaKPC of -4.0% in Enterobacterales, and an annual increase for blaNDM of 71.6% and for blaKPC of 22.2% in P. aeruginosa. From 2020 to 2022, overall increases of 65.2% for Enterobacterales, 77.7% for ABC, and 61.3% for P. aeruginosa were observed in the total isolates. CONCLUSIONS: This study shows the strengths of the AMR Brazilian Surveillance Network with robust data related to carbapenemases in Brazil and the impact of COVID-19 with a change in carbapenemase profiles with blaNDM rising over the years.


Asunto(s)
Acinetobacter baumannii , COVID-19 , Humanos , Pseudomonas aeruginosa/genética , Carbapenémicos/farmacología , Acinetobacter baumannii/genética , Brasil/epidemiología , Pandemias , COVID-19/epidemiología , Proteínas Bacterianas/genética , beta-Lactamasas/genética , Plásmidos , Antibacterianos/farmacología , Pruebas de Sensibilidad Microbiana
3.
J Bras Nefrol ; 45(3): 373-377, 2023.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-37158483

RESUMEN

INTRODUCTION: Urinary catheter-related infection is commonly associated with bacterial biofilm. The impact of anaerobes is unknown, but their detection in the biofilm on this device has not been previously reported. This study aimed to evaluate the capability to recovery strict, facultative, and aerobic microorganisms in patients using bladder catheters from ICUs using conventional culture, sonication, urinary analysis, and mass spectrometry. METHODS: Parallel, sonicated bladder catheters from 29 critically ill patients were compared with their routine urine culture. Identification was performed using matrix-assisted laser desorption/ionization with time-of-flight mass spectrometry. RESULTS: The positivity rate in urine (n = 2, 3.4%) was lower than that in sonicated catheters (n = 7, 13.8%). CONCLUSION: Bladder catheter sonication showed more positive culture results than urine samples for anaerobic and aerobic microorganisms. The role of anaerobes in urinary tract infection and catheter biofilm is discussed.


Asunto(s)
Infecciones Relacionadas con Catéteres , Infecciones Urinarias , Humanos , Sonicación/métodos , Vejiga Urinaria , Catéteres , Biopelículas , Infecciones Relacionadas con Catéteres/microbiología , Infecciones Urinarias/microbiología , Catéteres de Permanencia
4.
Braz J Microbiol ; 54(2): 849-857, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36991280

RESUMEN

The laboratory diagnosis of Clostridioides difficile infection (CDI) is challenging since this bacteria may be detected in healthy people and toxin production detection is not sensitive enough to be used alone. Thus, there is no single test with adequate sensitivity and specificity to be used in laboratory diagnosis. We evaluated the performance of tests used in the diagnosis of CDI in symptomatic patients with risk factors in hospitals in southern Brazil. Enzyme immunoassays (EIA) for glutamate dehydrogenase antigen (GDH) and toxins A/B, real-time polymerase chain reaction (qPCR), GeneXpert system, and a two-step algorithm comprising GDH/TOXIN EIA performed simultaneously followed by GeneXpert for outliers were evaluated. Toxigenic strain in stool culture was considered CDI positive (gold standard). Among 400 samples tested, 54 (13.5%) were positive for CDI and 346 (86.5%) were negative. The diagnosis of the two-step algorithm and qPCR had an excellent performance with an accuracy of 94.5% and 94.2%, respectively. The Youden index showed that GeneXpert as a single test (83.5%) and the two-step algorithm (82.8%) were the most effective assays. Diagnosing CDI and non-CDI diarrhea could be successfully attained by the combination of clinical data with accuracy of laboratory tests.


Asunto(s)
Toxinas Bacterianas , Clostridioides difficile , Infecciones por Clostridium , Humanos , Toxinas Bacterianas/genética , Toxinas Bacterianas/análisis , Clostridioides difficile/genética , Proteínas Bacterianas/genética , Proteínas Bacterianas/análisis , Heces/microbiología , Infecciones por Clostridium/diagnóstico , Infecciones por Clostridium/microbiología , Enterotoxinas , Sensibilidad y Especificidad , Reacción en Cadena en Tiempo Real de la Polimerasa , Glutamato Deshidrogenasa/análisis , Técnicas de Laboratorio Clínico
5.
Artículo en Inglés | MEDLINE | ID: mdl-36722674

RESUMEN

Rare emerging pathogens such as Saprochaete clavata are associated with invasive fungal diseases, high morbidity, mortality, rapidly fatal infections, and outbreaks. However, little is known about S. clavata infections, epidemiology, risk factors, treatment, biofilms, and disease outcomes. The objective of this study was to describe a new case of severe S. clavata infection in a patient diagnosed at a referral children's hospital in Brazil, including antifungal minimal inhibitory concentration, S. clavata biofilm characterization, and molecular characterization. The S. clavata isolated from an immunocompromised 11-year-old male patient was characterized using MALDI-TOF, Gram staining, scanning electron microscopy (SEM), and next generation sequencing (NGS) of genomic DNA. Biofilm production was also evaluated in parallel with determining minimal inhibitory concentration (MIC) and biofilm sensitivity to antifungal treatment. We observed small to medium, whitish, farinose, dry, filamentous margin colonies, yeast-like cells with bacillary features, and biofilm formation. The MALDI-TOF system yielded a score of ≥ 2,000, while NGS confirmed S. clavata presence at the nucleotide level. The MIC values (in mg L-1) for tested drugs were as follows: fluconazole = 2, voriconazole ≤ 2, caspofungin ≥ 8, micafungin = 2, amphotericin B = 4, flucytosine ≤ 1, and anidulafungin = 1. Amphotericin B can be active against S. clavata biofilm and the fungus can be susceptible to new azoles. These findings were helpful for understanding the development of novel treatments for S. clavata-induced disease, including combined therapy for biofilm-associated infections.


Asunto(s)
Antifúngicos , Saccharomyces cerevisiae , Niño , Masculino , Humanos , Antifúngicos/farmacología , Anfotericina B , Brasil , Biopelículas
6.
Enferm Infecc Microbiol Clin (Engl Ed) ; 41(10): 596-603, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36707288

RESUMEN

INTRODUCTION: Biofilm formation causes virulence and resistance in Candida albicans. However, little is known about breakthrough candidemia isolates. We evaluated the antifungal activity of fluconazole, anidulafungin, deoxycholate amphotericin B (dAMB), and amphotericin B lipid complex (ABLC) against biofilms of C. albicans isolated from patients with breakthrough candidemia. METHODS: The present study used strains of C. albicans isolated from breakthrough and non-breakthrough candidemia patients (control group). The susceptibility of planktonic cells to amphotericin B, anidulafungin, and fluconazole was determined by broth microdilution. Antifungal activity in sessile cells was evaluated using the minimum biofilm eradication concentration (MBEC), metabolic activity was estimated by reducing MTT, and biomass was estimated using crystal violet retention. RESULTS: The planktonic strains were susceptible to amphotericin B, anidulafungin, and fluconazole, with minimum inhibitory concentrations of 1, ≤0.03, and 2mg/L, respectively. However, fluconazole and anidulafungin did not exert an antifungal effect on biofilms. Additionally, dAMB and ABCL reduced the metabolic activity and biomass. However, eradication was only achieved using 16mg/L dAMB. C. albicans isolates of breakthrough candidemia exhibited strong biofilm production, and the in vitro activity of available therapeutic options was poor. CONCLUSION: In the present study, only dAMB and ABCL exhibited antibiofilm effects against sessile breakthrough candidemia isolates.


Asunto(s)
Anfotericina B , Candidemia , Humanos , Anfotericina B/farmacología , Anfotericina B/uso terapéutico , Antifúngicos/farmacología , Antifúngicos/uso terapéutico , Anidulafungina/farmacología , Anidulafungina/uso terapéutico , Fluconazol/farmacología , Fluconazol/uso terapéutico , Candida albicans , Candidemia/tratamiento farmacológico , Candida , Biopelículas , Ácido Desoxicólico/farmacología , Ácido Desoxicólico/uso terapéutico
7.
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1422790

RESUMEN

ABSTRACT Rare emerging pathogens such as Saprochaete clavata are associated with invasive fungal diseases, high morbidity, mortality, rapidly fatal infections, and outbreaks. However, little is known about S. clavata infections, epidemiology, risk factors, treatment, biofilms, and disease outcomes. The objective of this study was to describe a new case of severe S. clavata infection in a patient diagnosed at a referral children's hospital in Brazil, including antifungal minimal inhibitory concentration, S. clavata biofilm characterization, and molecular characterization. The S. clavata isolated from an immunocompromised 11-year-old male patient was characterized using MALDI-TOF, Gram staining, scanning electron microscopy (SEM), and next generation sequencing (NGS) of genomic DNA. Biofilm production was also evaluated in parallel with determining minimal inhibitory concentration (MIC) and biofilm sensitivity to antifungal treatment. We observed small to medium, whitish, farinose, dry, filamentous margin colonies, yeast-like cells with bacillary features, and biofilm formation. The MALDI-TOF system yielded a score of ≥ 2,000, while NGS confirmed S. clavata presence at the nucleotide level. The MIC values (in mg L-1) for tested drugs were as follows: fluconazole = 2, voriconazole ≤ 2, caspofungin ≥ 8, micafungin = 2, amphotericin B = 4, flucytosine ≤ 1, and anidulafungin = 1. Amphotericin B can be active against S. clavata biofilm and the fungus can be susceptible to new azoles. These findings were helpful for understanding the development of novel treatments for S. clavata-induced disease, including combined therapy for biofilm-associated infections.

8.
J Orthop Sci ; 2022 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-36526520

RESUMEN

BACKGROUND: This study aimed to evaluate different concentrations of vancomycin and/or gentamicin loaded polymethylmethacrylate (PMMA) against biofilm formation of Staphylococcus aureus. METHODS: Biofilm production of S. aureus in PMMA loaded with different concentrations of vancomycin and gentamicin were evaluated by quantitative analysis of biofilm cells, scanning electronic microscopy, viability assay, Fourier transform infrared spectroscopy, and checkerboard. Statistical analysis was performed by Mann Whitney test. The difference in colony forming units per mL was significant when p < 0.05. RESULTS: All loaded PMMA presented a reduction in the number of colony forming units per mL (p < 0.05). The gentamicin-loaded PMMA could inhibits the grown of sessile cells (p < 0.05), where the group vancomycin 4 g + gentamicin 500 mg presented a better result. The Fourier transform infrared spectra showed no significant differences, and checkerboard of vancomycin and gentamicin showed synergism. CONCLUSION: Effects against adherence and bacterial development in PMMA loaded with antibiotics were mainly seen in the group vancomycin 4 g + gentamicin 500 mg, and synergic effect can be applied in antibiotic-loaded cement.

9.
J Fungi (Basel) ; 8(12)2022 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-36547613

RESUMEN

Invasive candidiasis (IC) contributes to the morbidity and mortality of hospitalized patients and represents a significant burden to the healthcare system. Previous Brazilian studies have reported the presence of endemic Candida parapsilosis sensu stricto genotypes causing candidemia and clonal transmission involving fluconazole-resistant isolates. We performed a 5-year retrospective analysis of IC cases in a Brazilian tertiary pediatric hospital and conducted a molecular investigation of C. parapsilosis sensu stricto. Non-duplicate C. parapsilosis sensu stricto genotyping was performed by microsatellite analysis. Antifungal susceptibility and biofilm formation were also evaluated. A total of 123 IC episodes were identified, with an IC incidence of 1.24 cases per 1000 hospital admissions and an overall mortality of 34%. The main species were the C. parapsilosis complex (35.8%), Candida albicans (29.2%), and Candida tropicalis (21.9%). All C. parapsilosis sensu stricto were recovered from blood cultures, and 97.5% were biofilm producers. Microsatellite typing identified high genotypic diversity among the isolates. We observed that all isolates were sensitive to amphotericin B, and although one isolate was non-sensitive to fluconazole, only a silent mutation on ERG11 gene was identified. No clear evidence of clonal outbreak or emergence of fluconazole-resistant isolates was found, suggesting that multiple sources may be involved in the epidemiology of IC in children.

10.
Cell Tissue Bank ; 23(3): 531-540, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35067845

RESUMEN

The decellularization of bovine bone has emerged as a strategy for the repair, replacement, and regeneration of bone defects. To evaluate the effects of a new protocol of bone decellularization and its impact on the structure and collagen scaffold. Cancellous bone from bovine femur was dissected in fragments and decellularized based on protocol of multiple steps. The residual protein levels, histological, morphometric, and scanning electronic microscopy analyses were carried out to evaluate the effects of decellularization and the impact on the structure and collagen scaffold. A cytotoxicity assay was performed. Residual protein analysis showed an important removal of bone marrow components and cell debris from the bone. Sections revealed that collagen fibers presented integrity and absence of cells in the decellularized bone. Sirius Red-stained sections of collagen fiber collagen matrix were maintained after decellularization. Scanning electron microscopy revealed that the main bone structure, despite being irregular, was maintained in both groups, with no significant visual differences between the surface characteristics according to the groups. Decellularized bovine bone demonstrated a degree of toxicity of 3, indicating moderate reactivity. The present data demonstrate that the main bone structure was maintained. Additionally, the chemical and physical treatments were able to remove cellular debris, and extracellular matrix architecture and collagen were preserved. However, the tissue showed moderate toxicity.


Asunto(s)
Colágeno , Ingeniería de Tejidos , Animales , Bovinos , Colágeno/análisis , Matriz Extracelular/metabolismo , Preservación Biológica , Ingeniería de Tejidos/métodos , Andamios del Tejido
11.
Eur J Orthop Surg Traumatol ; 32(5): 981-989, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34236512

RESUMEN

BACKGROUND: Titanium and polyether-ether-ketone (PEEK) interbody cages are commonly used for spine fusion. Few data are known about bacterial and yeast biofilms formation in these implants. The aim of this study was to compare Staphylococcus aureus and Candida albicans biofilm formation in the surface of two different interbody devices used routinely in spine surgery. METHODS: Six bodies of proof specimens of PEEK and titanium alloy were used for microbiological tests, scanning electron microscopy, and energy-dispersive X-ray spectroscopy. Experimental biofilm was produced with Staphylococcus aureus and Candida albicans, followed by quantitative analysis of planktonic cells and sessile cells. The comparison between the medians of biofilm quantification between the two models was performed using the Mann-Whitney test and considered the statistical difference for a p < 0.05. RESULTS: In the S. aureus model, in both planktonic and sessile cell counts, titanium-alloy samples showed lower values for colony forming units per milliliter (UFC/mL) (p < 0.05). The evaluation through the optic density of planktonic and sessile cells showed lower values in the titanium-alloy samples, however, only statistically significant in planktonic cell count (p < 0.05). The count of planktonic yeast cells in PEEK was similar to titanium-alloy samples, while the count of sessile yeast cells in titanium alloy was lower when compared to PEEK (p < 0.05). CONCLUSION: Titanium-alloy models were associated with less staphylococcal and Candida biofilm formation when compared with PEEK.


Asunto(s)
Infecciones Estafilocócicas , Titanio , Aleaciones , Benzofenonas , Biopelículas , Candida albicans , Humanos , Cetonas , Polietilenglicoles/farmacología , Polímeros , Infecciones Estafilocócicas/microbiología , Staphylococcus aureus
12.
Cell Tissue Bank ; 22(4): 643-649, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34091815

RESUMEN

Musculoskeletal allografts are used in reconstructive procedures, however, the risk of contamination with potential pathogens is possible, and safe transplantation requires multiple processing considerations. Hydrogen peroxide (H2O2) has commonly been used in bone washing because it can remove donor cells and eliminate antigens, pathogens, or cytotoxic agents from the matrix. The aim of this study was to evaluate the quantitative activity of H2O2 in a model of bone contamination with a high bacterial load to define the bioburden reduction. Twelve bone disc models were artificially contaminated with Staphylococcus aureus. The bones were treated with a washing process composed by antibiotics, 30% hydrogen peroxide, and 70% alcohol. Tryptic Soy Agar plates were directly inoculated with 100µL of each step of the washing process and colonies were counted in CFU/mL. Scanning electron microscopy was used for bone structural analysis before and after the washing process. After antibiotics, there was a drop of less than 1 log for cancellous bone and almost 1 log for cortical bone. However, after H2O2, there as a drop of 3 logs for cortical (p = 0.007), and 2 logs for cancellous bone (p = 0.063). The use of alcohol did not change the bioburden following H2O2 in cancellous and cortical bone. Despite the important drop of bacterial load, H2O2 was not enough to completely eradicate bacterial with this model of bioburden. H2O2 is useful in decontamination, but antibiotics have little activity, and alcohol is useless. The process is useful in decontamination up to 3 logs of bioburden.


Asunto(s)
Desinfección , Peróxido de Hidrógeno , Aloinjertos , Humanos , Peróxido de Hidrógeno/farmacología , Bancos de Tejidos , Trasplante Homólogo
14.
Eur J Orthop Surg Traumatol ; 31(6): 1113-1120, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33394140

RESUMEN

BACKGROUND: The gold standard for microbial detection in prosthetic joint infections is the multiple culture of the peri-prosthetic tissue. The fluid cultures after sonication can improve the recovery of the microorganisms. OBJECTIVE: The aim of this study was to evaluate the sonication technique with a plastic bag and the effect of refrigeration on microorganism detection with conventional culturing, MALDI-TOF MS and qPCR assay on an orthopedic screw model. METHODS: We produced biofilms of Staphylococcus aureus, Pseudomonas aeruginosa, and Candida albicans on orthopedic screws, which were stored under different conditions and temperatures before sonication. After sonication, the mass spectrometry by MALDI-TOF, qPCR and culture protocols was performed using the sonicated fluid, for detecting the microorganisms involved in the biofilm. RESULTS: The bacterial bioburden decreased by approximately one log after the refrigeration period, in the screws containing P. aeruginosa and S. aureus biofilms. All the microorganisms involved in the screw biofilms were detected with MALDI-TOF and qPCR. Significant reductions in CFU counts occurred only in groups stored in the plastic bag, indicating that changes in temperature and humidity may favor cell death. However, this variation is not important for this model as it did not affect the detection owing to the high counts obtained. CONCLUSION: Microbial identification by MALDI-TOF in sonicated fluid is feasible. With qPCR, there were no differences between the detection in the screws processed immediately or after refrigeration. It is necessary to consider whether or not the refrigeration period would affect microbial recovery in an explanted prosthesis.


Asunto(s)
Artritis Infecciosa , Infecciones Relacionadas con Prótesis , Biopelículas , Humanos , Infecciones Relacionadas con Prótesis/diagnóstico , Sonicación , Staphylococcus aureus
15.
Med Mycol ; 59(1): 1-6, 2021 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-32343341

RESUMEN

Pseudozyma spp. are described as environmental yeasts but have also been identified as rare human pathogens found in immunocompromised patients. This systematic review details the clinical manifestations, diagnostic methodology, and empirical anti-fungal therapy for this rare yeast. PubMed, LILACS, Scielo, and Web of Science databases were searched for articles about Pseudozyma spp. infections from inception to June 2019. Inclusion criteria were any published studies that included patients with Pseudozyma spp. infection. Infections were identified using criteria set forth by the European Organization for Research and Treatment of Cancer, and were further classified according to clinical, laboratory, or radiologic findings, microbiologic confirmation, and response to therapy. Eleven articles were included with 15 patients. Oncological and/or hematological disorders were the most reported risk factors. Nontraditional microbiological methods correctly identified Pseudozyma spp., whereas traditional methods failed to identify fungal genus. Species were identified by sequencing, and most demonstrated a higher minimal inhibitory concentration (MIC) for fluconazole and echinocandins. MICs for itraconazole, voriconazole, and posaconazole varied by species. All isolates were susceptible to amphotericin B, which was the most used treatment. Pseudozyma spp. infections usually present with fever and are diagnosed by blood culture. Most species studied appeared to be resistant to fluconazole and echinocandin. Voriconazole, posaconazole, and amphotericin were effective in treating P. aphidis. However, more studies are needed to evaluate voriconazole and posaconazole in species other than P. aphidis.


Asunto(s)
Anfotericina B/uso terapéutico , Antifúngicos/uso terapéutico , Fluconazol/uso terapéutico , Itraconazol/uso terapéutico , Micosis/tratamiento farmacológico , Voriconazol/uso terapéutico , Levaduras/patogenicidad , Anfotericina B/farmacología , Antifúngicos/farmacología , Equinocandinas/farmacología , Fluconazol/farmacología , Humanos , Itraconazol/farmacología , Voriconazol/farmacología
16.
Cell Tissue Bank ; 21(4): 573-584, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32809090

RESUMEN

Residual chemicals that are presented during tissue processing in human tissue banks can be a risk for the allograft recipient. Determine the residual concentrations of the antibiotics and detergent used in the process of human decellularized tissue-engineered heart valves stored in isotonic saline solution up to 18 months. A total of 24 human decellularized allografts were stored in sterile sodium chloride and analyzed immediately after the decellularization process (0 months) and after storage for 6, 12, and 18 months, which includes the use of sodium dodecyl sulfate (SDS) and antibiotics (cefoxitin, vancomycin hydrochloride, lincomycin hydrochloride, polymyxin B sulfate). These valves were used for suitability tests, the zone of inhibition evaluation, and direct contact cytotoxicity assay. The stock solution from 32 valves was used for LC-MS/MS analysis of antibiotics and SDS. Tissue samples from decellularized valves showed a zone of inhibition formation for S. aureus and B. subtilis, suggesting the presence of an inhibitory molecule in the tissue. Cytotoxicity tests were negative. Polymyxin B, vancomycin, and SDS were detected and quantified in human decellularized aortic and pulmonary allografts during all periods of the study. There were no traces of residual cefoxitin and lincomycin in the tissue stock solution. We found residual concentrations of the antibiotics and detergent used in the process of human decellularized tissue-engineered heart valves stored in isotonic saline solution up to 18 months.


Asunto(s)
Antibacterianos/análisis , Detergentes/análisis , Válvulas Cardíacas/fisiología , Espectrometría de Masas en Tándem , Ingeniería de Tejidos , Animales , Antibacterianos/farmacología , Bacterias/efectos de los fármacos , Muerte Celular/efectos de los fármacos , Cromatografía Liquida , Fibroblastos/citología , Fibroblastos/efectos de los fármacos , Humanos , Ratones , Pruebas de Sensibilidad Microbiana
17.
Biopreserv Biobank ; 18(2): 90-101, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31990593

RESUMEN

Background: The best storage preservation method for maintaining the quality and safety of human decellularized allograft heart valves is yet to be established. Objective: The aim of the present study was to evaluate the stability in terms of extracellular matrix (ECM) integrity of human heart valve allografts decellularized using sodium dodecyl sulfate-ethylenediaminetetraacetic acid (SDS-EDTA) and stored for 6, 12, and 18 months. Methods: A total of 70 decellularized aortic and pulmonary valves were analyzed across different storage times (0, 6, 12, and 18 months) for solution pH measurements, histological findings, cytotoxicity assay results, biomechanical test results, and microbiological suitability test results. Continuous data were analyzed using one-way analysis of variance comparing the follow-up times. Results: The pH of the stock solution did not change during the different time points, and no microbial growth occurred up to 18 months. Histological analysis showed that the decellularized allografts did not present deleterious outcomes or signs of structural degeneration in the ECM up to 12 months. The biomechanical properties showed changes over time in different aspects. Allografts stored for 18 months presented lower tensile strength and elasticity than those stored for 12 months (p < 0.05). The microbiological suitability test suggested no residual antimicrobial effects. Conclusion: Changes in the structure and functionality of SDS-EDTA decellularized heart valve allografts occur after 12 months of storage.


Asunto(s)
Matriz Extracelular/metabolismo , Válvulas Cardíacas/fisiología , Solución Salina/química , Manejo de Especímenes/métodos , Aloinjertos , Fenómenos Biomecánicos , Ácido Edético/química , Válvulas Cardíacas/metabolismo , Humanos , Concentración de Iones de Hidrógeno , Dodecil Sulfato de Sodio/química , Factores de Tiempo
18.
J Clin Virol ; 121: 104203, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31715525

RESUMEN

BACKGROUND: Tissues from cadaveric donors are used in several clinical circumstances, and the transmission of infectious diseases has been reported. Cadaveric donor (CD) blood sample analysis is challenging due to its poor quality. However, studies have demonstrated the usefulness of molecular based methods, and the lack of studies using available commercial molecular tests was reported. OBJECTIVE: The aim of this study was to evaluate the performance, specificity, sensitivity, and accuracy of different commercial molecular tests for HIV and HCV detection and quantification in CD through spiked samples. STUDY DESIGN: 20 CD and 20 blood donor samples were tested using 1,000 copies/mL and 1,000 IU/mL of lyophilized standards of HIV and HCV, respectively. Samples were analyzed by different molecular kits: XPERT HCV Viral Load and HIV-1 (Cepheid), COBAS® TaqMan® HIV-1 and COBAS® TaqMan® HCV Test, v2.0 (Roche), and artus® HI Virus-1 QS-RGQ and artus® HCV RG RT-PCR Kit (Qiagen). RESULTS: HIV and HCV in CD were detected by RT-PCR-based quantitative kits. The tests performed by the Cepheid and the Roche kits showed the most accurate, sensitive and specific results, however, a wide variability between the assays and kits was observed. The Qiagen kits did not demonstrate satisfactory results. CONCLUSIONS: CD evaluation showed great variability. The Cepheid and Roche kits were more sensitive for detecting HIV on CD and Cepheid was the most efficient kit for HCV quantification in CD. The Roche and Cepheid kits can be used to screen tissue donors for HIV and HCV.


Asunto(s)
VIH-1/aislamiento & purificación , Hepacivirus/aislamiento & purificación , Patología Molecular/métodos , Juego de Reactivos para Diagnóstico , Donantes de Tejidos , Adolescente , Adulto , Anciano , Cadáver , Niño , Femenino , Infecciones por VIH/sangre , Hepatitis C/sangre , Humanos , Límite de Detección , Masculino , Persona de Mediana Edad , ARN Viral/sangre , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Carga Viral , Adulto Joven
19.
J Microbiol Methods ; 166: 105723, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31526821

RESUMEN

Although reports of infections caused by anaerobes after tissue transplantation are uncommon, contamination of allografts may result in substantial complications. Anaerobic incubation and testing of organ transport solution (TS) are not routine. The aim of this study was to determine the bioburden of strict anaerobic bacteria and oxygen tension of heart-TS. Forty TS from different donors were evaluated cultured using membrane filtration (MF), direct inoculation on broth and automated blood culture bottle (ABCB). Bacterial identification was performed by MALDI-TOF. The transport conditions were simulated to verify the bacterial recovery. A sterile bag fulfilled with 250 ml-1 of sterile saline was spiked with 100 CFU ml-1 of Clostridium perfringens and the fluid recovered 0 h, 1 h, 2 h, 6 h, 12 h, 24 h and 48 h for culture and oxygen measurement. Strict anaerobic bacteria were not isolated in heart-TS. The recovery of C.perfringens spiked in heart-TS was 100% using automated blood culture bottles. MF method detected >100 CFU only after 6 h of spiking. The manual culture was not able to recover C.perfringens after the process. The percentage of O2 measures varied from 77.6 to 87.9%. MF or ABCB are better than direct inoculation for recovery of anaerobes from heart-TS. Although all samples from heart donors were negative for anaerobes (probably due to low incidence of contamination), C.perfringens were all recovered in the simulated transport condition.


Asunto(s)
Aloinjertos/microbiología , Bacterias Anaerobias/aislamiento & purificación , Clostridium perfringens/aislamiento & purificación , Válvulas Cardíacas/microbiología , Válvulas Cardíacas/trasplante , Soluciones Preservantes de Órganos , Humanos
20.
Cell Tissue Bank ; 20(1): 87-94, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30729370

RESUMEN

The contamination of the transport solution used in cardiovascular allografts can occur from different sources. Risk factors associated with positive microbiological test of transport solution have not been reported previously. This study aimed to determine the risk factor for contamination of transport solution used in the heart valve allografts stored in a Brazilian tissue bank. This retrospective study was conducted on all donors of cardiovascular allografts stored in a tissue bank from December 2008 to December 2017. Microbiological cultures for aerobic and anaerobic bacteria, fungi/yeasts were carried out in TS. Clinical variables were included. From 1001 transport solution, 52% were contaminated. A total of 770 microorganisms were identified, and Staphylococcus spp. was identified in 248 isolates (32.2%). Skin bacteria from skin microbiota were the most commonly identified microorganisms (Staphylococcus spp., Cutibacterium spp., Corynebacterium spp., and Bacillus spp.), occurring in 49.6%. The presence of a diagnosis of healthcare-associated infection was not associated with skin contamination (odds ratio [OR] 0.62 [0.41-0.94]; p = 0.014). Conditions like fever, use of antibiotics, and leukocytosis were less likely associated with contamination of transport solution. A longer warm ischemic time was associated with higher frequency of contamination. In the multivariable analysis, warm ischemic time was independently associated with contamination, and antibiotic therapy was a factor that decreased the rate of contamination (p < 0.05). Contamination of transport solution is associated with modifiable risk factors, such as warm ischemic time. Measures to minimize contamination should be employed to avoid unnecessary tissue discharges.


Asunto(s)
Aloinjertos/microbiología , Válvulas Cardíacas/fisiología , Bancos de Tejidos , Adulto , Bacterias/aislamiento & purificación , Femenino , Humanos , Masculino , Factores de Riesgo , Soluciones , Transportes
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...