Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 107
Filtrar
1.
iScience ; 27(4): 109410, 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38558941

RESUMEN

The tobacco hornworm is a laboratory model that is particularly suitable for analyzing gut inflammation, but a physiological reference standard is currently unavailable. Here, we present a surface atlas of the healthy hornworm gut generated by scanning electron microscopy and nano-computed tomography. This comprehensive overview of the gut surface reveals morphological differences between the anterior, middle, and posterior midgut, allowing the screening of aberrant gut phenotypes while accommodating normal physiological variations. We estimated a total resorptive midgut surface of 0.42 m2 for L5d6 larvae, revealing its remarkable size. Our data will support allometric scaling and dose conversion from Manduca sexta to mammals in preclinical research, embracing the 3R principles. We also observed non-uniform gut colonization by enterococci, characterized by dense biofilms in the pyloric cone and downstream of the pylorus associated with pore and spine structures in the hindgut intima, indicating a putative immunosurveillance function in the lepidopteran hindgut.

2.
J Clin Med ; 12(24)2023 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-38137787

RESUMEN

The endodontic treatment of primary teeth is to maintain the function of the tooth free of symptoms until its physiological exfoliation. A critical factor for success is how quickly and effectively the root canal preparation can be performed. Therefore, the aim of this comparative in vitro study was to analyze the efficiency of two mechanical root canal preparation systems FM (FlexMaster) and HF (HyFlex EDM) to manual KF (K-file) on extracted primary molars. A total of 45 teeth were divided into three groups (n = 15): KF (#15-35), FM (04#30) and HF (25/~ OneFile). Root canal preparation was performed, and the preparation time was measured. All root canals were non-destructively analyzed by micro-computed tomography in the cervical, middle and apical thirds before and after preparation with regard to the parameters of canal transport (in µm) and centering ratio (0-1). Statistical analysis was performed at a 5% significance level using non-parametric tests. HF caused the lowest canal transport in the apical third (p = 0.008). The centering ratio value of HF was significantly higher in the middle third of the root canals than in the other two groups (p < 0.01). The mean instrumentation time was significantly higher for KF (6.67 min) than for FM (4.69 min) and HF (4.03 min, p < 0.01). HF can be recommended for primary molar root canal treatment.

3.
J Clin Med ; 12(15)2023 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-37568349

RESUMEN

Idiopathic condylar resorption (ICR), though a rare event, is associated with severe detrimental sequelae for the patient. To date, the etiology remains unknown, and treatment strategies are highly controversial. Therefore, the aim of this study is to present an analysis of the consensus- and evidence-based approach to ICR by a German interdisciplinary guideline project of the AWMF (Association of the Scientific Medical Societies in Germany). Following a systematic literature search, including 56 (out of an initial 97) publications, with a predominantly low level of evidence (LoE), two independent working groups (oral and maxillofacial surgery and interdisciplinary, respectively) voted on a draft comprising 25 recommendations in a standardized anonymized and blinded Delphi procedure. While the results of the votes were relatively homogeneous, the interdisciplinary phase required a significantly higher number of rounds (p < 0.001). Most of the controversial recommendations were related to initial imaging (with consensus on CT/CBCT as the current diagnostic standard for imaging), pharmacotherapy (no recommendation due to lack of evidence), discopexy (no recommendation possible due to low LoE) and timing of orthognathic surgery (with consensus on two-staged procedures after invasive TMJ surgery, except for single-stage procedures if combined with total joint reconstruction). Overall, the Delphi procedure resulted in an interdisciplinary guideline offering the best possible evidence- and consensus-based expertise to date in the diagnosis and treatment of ICR.

4.
Eur J Radiol ; 165: 110949, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37392544

RESUMEN

PURPOSE: To assess the feasibility of a periprocedural decision on the administration of intravenous contrast media in MRI for endometriosis and to evaluate the frequency and reasons of contrast administrations, the corresponding MRI diagnoses, and outcome. METHODS: In this retrospective, descriptive cross-sectional single-center study all patients were included, who received a pelvic MRI for evaluation of endometriosis between April 2021 and February 2023. Frequency and reasons of optional intravenous administration of contrast media, corresponding MRI diagnoses and clinical outcome data were noted after re-review of all images, review of radiology reports and review of patients' medical records. The decision on the administration of intravenous contrast media had been made by experienced radiologists, depending on the findings of the non-contrast sequences and the presence of ancillary questions. RESULTS: 303 consecutive patients (mean age, 33.4 years +/- 8.3 [standard deviation]) were evaluated. Periprocedural decision on the administration of intravenous contrast media had been made in all cases. For 219/303 (72.3%) patients, it was decided after review of the non-contrast sequences and exclusion of ancillary questions that contrast administration was not required. 84/303 (27.7%) patients received contrast media, and the most frequent reasons were indeterminate ovarian lesion (41/84 cases, 48.8%) or suspicion of pelvic venous congestion syndrome (26/84 cases, 31.0%). No relevant differences in patient outcomes could be noted (non-contrast/contrast MRI). CONCLUSIONS: A periprocedural decision on the administration of contrast media in MRI for endometriosis is feasible with little effort. It allows the administration of contrast media to be avoided in most cases. If the administration of contrast media is deemed necessary, repeat examinations can be avoided.


Asunto(s)
Endometriosis , Femenino , Humanos , Adulto , Endometriosis/diagnóstico por imagen , Endometriosis/patología , Medios de Contraste , Estudios Retrospectivos , Estudios Transversales , Estudios de Factibilidad , Imagen por Resonancia Magnética/métodos , Dolor Pélvico , Administración Intravenosa
5.
iScience ; 26(6): 106801, 2023 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-37378344

RESUMEN

The tobacco hornworm is used extensively as a model system for ecotoxicology, immunology and gut physiology. Here, we established a micro-computed tomography approach based on the oral application of the clinical contrast agent iodixanol, allowing for a high-resolution quantitative analysis of the Manduca sexta gut. This technique permitted the identification of previously unknown and understudied structures, such as the crop or gastric ceca, and revealed the underlying complexity of the hindgut folding pattern, which is involved in fecal pellet formation. The acquired data enabled the volume rendering of all gut parts, the reliable calculation of their volumes, and the virtual endoscopy of the entire alimentary tract. It can provide information for accurate orientation in histology uses, enable quantitative anatomical phenotyping in three dimensions, and allow the calculation of locally effective midgut concentrations of applied chemicals. This atlas will provide critical insights into the evolution of the alimentary tract in lepidopterans.

6.
PLoS One ; 18(6): e0286039, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37315002

RESUMEN

Good fixation of filigree specimens for micro-CT examinations is often a challenge. Movement artefacts, over-radiation or even crushing of the specimen can easily occur. Since different specimens have different requirements, we scanned, analysed and compared 19 possible fixation materials under the same conditions in the micro-CT. We focused on radiodensity, porosity and reversibility of these fixation materials. Furthermore, we have made sure that all materials are cheap and easily available. The scans were performed with a SkyScan 1173 micro-CT. All dry fixation materials tested were punched into 5 mm diameter cylinders and clamped into 0.2 ml reaction vessels. A voxel size of 5.33 µm was achieved in a 180° scan in 0.3° steps. Ideally, fixation materials should not be visible in the reconstructed image, i.e., barely binarised. Besides common micro-CT fixation materials such as styrofoam (-935 Hounsfield Units) or Basotect foam (-943 Hounsfield Units), polyethylene air cushions (-944 Hounsfield Units), Micropor foam (-926 Hounsfield Units) and polyurethane foam, (-960 Hounsfield Units to -470 Hounsfield Units) have proved to be attractive alternatives. Furthermore, more radiopaque materials such as paraffin wax granulate (-640 Hounsfield Units) and epoxy resin (-190 Hounsfield Units) are also suitable as fixation materials. These materials often can be removed in the reconstructed image by segmentation. Sample fixations in the studies of recent years are almost all limited to fixation in Parafilm, Styrofoam, or Basotect foam if the fixation type is mentioned at all. However, these are not always useful, as styrofoam, for example, dissolves in some common media such as methylsalicylate. We show that micro-CT laboratories should be equipped with various fixation materials to achieve high-level image quality.


Asunto(s)
Polietileno , Poliestirenos , Microtomografía por Rayos X , Artefactos , Parafina
7.
Diagnostics (Basel) ; 13(10)2023 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-37238278

RESUMEN

Several current guidelines recommend imaging in the diagnostic work-up of deep infiltrating endometriosis (DIE). The purpose of this retrospective diagnostic test study was to evaluate the diagnostic accuracy of MRI compared to laparoscopy for the identification of pelvic DIE, considering lesion morphology using MRI. In all, 160 consecutive patients were included who received pelvic MRI for evaluation of endometriosis between October 2018 and December 2020 and underwent subsequent laparoscopy within 12 months of the MRI examination. MRI findings were categorized for suspected DIE using the Enzian classification and were additionally graded using a newly suggested deep infiltrating endometriosis morphology score (DEMS). Endometriosis was diagnosed in 108 patients (all types, i.e., purely superficial and DIE), of which 88 cases were diagnosed with DIE and 20 with solely superficial peritoneal endometriosis (i.e., not deep infiltrating endometriosis/DIE). The overall positive and negative predictive values of MRI for the diagnosis of DIE, including lesions with assumed low and medium certainty of DIE on MRI (DEMS 1-3), were 84.3% (95% CI: 75.3-90.4) and 67.8% (95% CI: 60.6-74.2), respectively, and 100.0% and 59.0% (95% CI: 54.6-63.3) when strict MRI diagnostic criteria were applied (DEMS 3). Overall sensitivity of MRI was 67.0% (95% CI: 56.2-76.7), specificity was 84.7% (95% CI: 74.3-92.1), accuracy was 75.0% (95% CI: 67.6-81.5), positive likelihood ratio (LR+) was 4.39 (95% CI: 2.50-7.71), negative likelihood ratio (LR-) was 0.39 (95% CI: 0.28-0.53), and Cohen's kappa was 0.51 (95% CI: 0.38-0.64). When strict reporting criteria are applied, MRI can serve as a method to confirm clinically suspected DIE.

8.
J Clin Med ; 12(6)2023 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-36983095

RESUMEN

BACKGROUND: Parametric imaging has taken a steep rise in recent years and non-cardiac applications are of increasing interest. Therefore, the aim of our study was to assess right (RV) and left ventricular (LV) blood pool T1 and T2 values in patients with chronic thromboembolic pulmonary hypertension (CTEPH) compared to control subjects and their correlation to pulmonary hemodynamic. METHODS: 26 patients with CTEPH (mean age 64.8 years ± 12.8 SD; 15 female), who underwent CMR and right heart catheterization (RHC) before and 6-months after balloon pulmonary angioplasty (BPA), were retrospectively included. Ventricular blood pool values were measured, compared to control subjects (mean age 40.5 years ± 12.8 SD; 16 female) and correlated to invasive measures (CI, mPAP, PVR). RESULTS: In both, control subjects and CTEPH patients, RVT1 and RVT2 were significantly reduced compared to LVT1 and LVT2. Compared to control subjects, RVT2 was significantly reduced in CTEPH patients (p = 0.0065) and increased significantly after BPA (p = 0.0048). Moreover, RVT2 was positively correlated with CI and negatively correlated with mPAP and PVR before (r = 0.5155, r = -0.2541, r = -0.4571) and after BPA (r = 0.4769, r = -0.2585, r = -0.4396). CONCLUSION: Ventricular blood pool T2 mapping might be novel non-invasive CMR imaging marker for assessment of disease severity, prognosis, follow-up and even therapy monitoring in PH.

10.
Clin Biomech (Bristol, Avon) ; 102: 105875, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36634601

RESUMEN

BACKROUND: Surgical treatment of proximal humeral fractures poses a major challenge, especially in osteoporotic bone. At present, there appears to exist neither a suitable model for research to optimize the osteosynthesis processes nor are the structural data available which are required for developing such a model. Therefore, the aim of this study is to determine the microscopic morphology and Young's modulus of cancellous bone from human humeral heads considering osteoporotic changes. METHODS: Cylindrical samples were taken from ten fresh-frozen human humeral heads and structural analysis was done with µCT. Ten rod-like trabeculae were prepared from five of the humeral heads each which were measured and tested mechanically. For this purpose, the trabeculae were fixed on a slide and rotated axially under a stereo microscope. The sample cross-section and the depending moment of inertia were extracted from the image data. The samples were then loaded in a 2-point bending test and Young's moduli of the samples were determined. RESULTS: It could be shown that with increasing age of the donor, ossified portion of the cancellous bone decreased (p < 0.05). The average degree of mineralization of the bone was 1.24 (±0.06) g/mm3, which decreased with increasing age (p < 0.05). The determined Young's modulus averaged 1.33 (±1.76) GPa. INTERPRETATION: The verified structural parameter showed osteoporotic changes in the examined bone. This study for the first time determined Young's modulus of single trabeculae of cancellous bone of osteoporotically altered human humeral heads. Implementing the non-destructive sample measurement before exposure resulted in a methodical improvement.


Asunto(s)
Densidad Ósea , Hueso Esponjoso , Humanos , Módulo de Elasticidad , Fenómenos Biomecánicos , Huesos
11.
Nat Commun ; 13(1): 7216, 2022 11 24.
Artículo en Inglés | MEDLINE | ID: mdl-36433960

RESUMEN

Mammalian models of human disease are expensive and subject to ethical restrictions. Here, we present an independent platform for high-throughput screening, using larvae of the tobacco hornworm Manduca sexta, combining diagnostic imaging modalities for a comprehensive characterization of aberrant phenotypes. For validation, we use bacterial/chemical-induced gut inflammation to generate a colitis-like phenotype and identify significant alterations in morphology, tissue properties, and intermediary metabolism, which aggravate with disease progression and can be rescued by antimicrobial treatment. In independent experiments, activation of the highly conserved NADPH oxidase DUOX, a key mediator of gut inflammation, leads to similar, dose-dependent alterations, which can be attenuated by pharmacological interventions. Furthermore, the developed platform could differentiate pathogens from mutualistic gastrointestinal bacteria broadening the scope of applications also to microbiomics and host-pathogen interactions. Overall, larvae-based screening can complement mammals in preclinical studies to explore innate immunity and host-pathogen interactions, thus representing a substantial contribution to improve mammalian welfare.


Asunto(s)
Interacciones Microbiota-Huesped , Manduca , Animales , Humanos , Ensayos Analíticos de Alto Rendimiento , Interacciones Huésped-Patógeno , Inflamación , Larva , Mamíferos
12.
Int J Mol Sci ; 23(15)2022 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-35897686

RESUMEN

Alloreactive and autoreactive antibodies have been associated with the development of chronic lung allograft dysfunction (CLAD), but their pathogenic role is disputed. Orthotopic left lung transplantation was performed in the Fischer-344 to Lewis rat strain combination followed by the application of ciclosporine for 10 days. Four weeks after transplantation, lipopolysaccharide (LPS) was instilled into the trachea. Lungs were harvested before (postoperative day 28) and after LPS application (postoperative days 29, 33, 40, and 90) for histopathological, immunohistochemical, and Western blot analyses. Recipient serum was collected to investigate circulating antibodies. Lung allografts were more strongly infiltrated by B cells and deposits of immunoglobulin G and M were more prominent in allografts compared to right native lungs or isografts and increased in response to LPS instillation. LPS induced the secretion of autoreactive antibodies into the circulation of allograft and isograft recipients, while alloreactive antibodies were only rarely detected. Infiltration of B cells and accumulation of immunoglobulin, which is observed in allografts treated with LPS but not isografts or native lungs, might contribute to the pathogenesis of experimental CLAD. However, the LPS-induced appearance of circulating autoreactive antibodies does not seem to be related to CLAD, because it is observed in both, isograft and allograft recipients.


Asunto(s)
Bronquiolitis Obliterante , Enfermedad Injerto contra Huésped , Trasplante de Pulmón , Aloinjertos/patología , Animales , Rechazo de Injerto , Enfermedad Injerto contra Huésped/patología , Inmunidad Humoral , Lipopolisacáridos , Pulmón/patología , Trasplante de Pulmón/efectos adversos , Ratas , Ratas Endogámicas Lew
13.
Eur J Radiol ; 147: 110111, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34952330

RESUMEN

PURPOSE: The aim of this study was to assess effects of balloon pulmonary angioplasty (BPA) on right ventricular (RV) mechanical dysfunction in patients with inoperable chronic thromboembolic pulmonary hypertension (CTEPH) via MRI. METHOD: MRI at 1.5 Tesla and right heart catheterization were performed before and 6 months after BPA in 30 CTEPH patients (mean age 63.4 ± 10.6 years; 17 female). Feature-tracking strain analysis, including global longitudinal (GLS), circumferential (GCS), and radial (GRS) strain, was performed and compared with right ventricular function, myocardial remodelling (assessed by native T1 times), and pulmonary haemodynamics (mean pulmonary arterial pressure and pulmonary vascular resistance). RESULTS: RVEF (35.9% to 48.4%) increased and mPAP (42.1 mmHg to 33.1 mmHg) and PVR (551.8 to 377.7 dyn∙s/cm5) decreased after BPA (all p < 0.0001). Moreover, RV strain increased (GLS -19.9 to -24.0%, p = 0.0003; GCS -9.4 to -11.0%, p = 0.0022; GRS 38.2 to 50.7%, p = 0.001) and septal native area-adjusted T1 time (AA-T1) decreased (1019.4 to 988.7 ms, p < 0.0001). GLS revealed the best correlations with RVEF (before BPA r = -0.75; after BPA r = -0.54), mPAP (r = 0.36; r = 0.52), PVR (r = 0.49; r = 0.48), and AA-T1 (r = 0.44; 0.19). CONCLUSION: RV mechanical dysfunction, pulmonary haemodynamics, and myocardial remodelling are markedly improved by BPA. Moreover, RV strain values showed good correlations with RV function, pulmonary haemodynamics, and myocardial remodelling. Therefore, strain analysis might provide new insights regarding therapy outcome, monitoring, and prognosis.


Asunto(s)
Angioplastia de Balón , Hipertensión Pulmonar , Embolia Pulmonar , Disfunción Ventricular Derecha , Anciano , Enfermedad Crónica , Femenino , Humanos , Hipertensión Pulmonar/diagnóstico por imagen , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Persona de Mediana Edad , Disfunción Ventricular Derecha/diagnóstico por imagen , Función Ventricular Derecha
14.
Eur J Radiol Open ; 8: 100384, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34712746

RESUMEN

PURPOSE: The aim of the study was to investigate the potential of electrocardiogram (ECG)-gated computed tomography pulmonary angiography (CTPA) as a predictor of disease severity in patients with chronic thromboembolic pulmonary hypertension (CTEPH). METHOD: Forty-five CTEPH patients with a mean age of 63.8 years±12.7 y (±standard deviation) who had undergone ECG-gated CTPA and right heart catheterization (RHC) were included in the study. Right ventricular to left ventricular volume ratio (RVV/LVV), diameter ratio on 4-chamber view (RVD4CH/LVD4CH), pulmonary trunk (PT) diameter, PT to aortic diameter ratio (PT/A), and septal angle were correlated to mean pulmonary artery pressure (mPAP). Moreover, RVV/LVV and RVD4CH/LVD4CH were adjusted to pulmonary diameter index (PADi) and PT/A index. Areas under the curve (AUC) for predicting mPAP above 40 mmHg, 35 mmHg, and 30 mmHg were calculated. RESULTS: RVD4CH/LVD4CH revealed the strongest correlation to mPAP before (r = 0.6507) and after (r = 0.7650; p < 0.0001) PT/A adjustment. The AUCs for predicting pH with mPAP over 40 mmHg and 30 mmHg were 0.9229 and 0.864, respectively. A cutoff value of 1.298 enabled prediction of pH with mPAP over 40 mmHg with a sensitivity, specificity, positive predictive, and negative predictive value of 80.00 %, 95.83 %, 88.46 %, and 94.12 %, respectively. Intra- and interobserver variability were excellent for all parameters. CONCLUSION: Combining different and easily evaluable ECG-gated CTPA parameters enables excellent prediction of pulmonary hemodynamics in CTEPH patients. Ventricular diameter ratio on 4-chamber view adjusted by the PT/A ratio yielded the best correlation to mPAP.

15.
J Mech Behav Biomed Mater ; 124: 104850, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34607300

RESUMEN

MOTIVE: External vibration excitation might be key to many novel non-surgical interventions for pathologies in the musculoskeletal system and in other parts of the human organism. Lack of understanding about vibration patterns, their controllability, and reproducibility are three limitations of ongoing research. This study establishes a bovine vibration model and animal model replacements for future research. METHODS: We used biological samples (n=5) and one polyurethane sample of the bovine femur. Mechanical resonance was measured experimentally and analysed numerically by finite element method. MAIN RESULTS: The experiments obtained 5 distinct mode shapes for the biological sample set, with standard deviation < 7.5%. Finite element analysis of the biological samples can replicate experimental mode shape deflection. The use of polyurethane changes resonance character but results are also good approximations of the biological samples. CONCLUSIONS: A model of the bovine femur with consistent resonance behaviour is presented with alternatives (polyurethane and finite element analysis) that can serve in reducing the number of necessary biological samples. Future work will be to adapt results to human anatomy. Of clinical interest will be to influence bone pathologies such as post-surgical non-union, or bone functionality as part of haematopoiesis and endocrine secretion.


Asunto(s)
Fémur , Vibración , Animales , Bovinos , Análisis de Elementos Finitos , Humanos , Modelos Biológicos , Modelos Teóricos , Reproducibilidad de los Resultados
17.
Radiologe ; 60(10): 959-965, 2020 Oct.
Artículo en Alemán | MEDLINE | ID: mdl-32495008

RESUMEN

BACKGROUND: The entry of the new Radiation Protection Act and new Radiation Protection Regulation into force in Germany created many changes for radiology with regard to the old Radiation Protection Regulation and X­ray Regulation. OBJECTIVES: The substantial modifications in radiology regarding the areas of approval and notification procedures, teleradiology, screening, research and radon in the workplace are summarized. METHOD: Changes in the new Radiation Protection Act and Regulation compared to the old Radiation Protection Regulation and X­ray Regulation were evaluated. Thereby, the focus was on areas beyond the workflow in clinical routine. RESULTS AND CONCLUSION: The requirements for the approval and notification procedure have increased. For example, proof must be provided that a medical physics expert can be consulted. The establishment of deadlines for the process by the responsible authorities may accelerate the procedure and create planning certainty.


Asunto(s)
Protección Radiológica , Radiología , Telerradiología , Alemania , Humanos , Protección Radiológica/legislación & jurisprudencia , Radiografía
18.
Radiologe ; 60(8): 721-728, 2020 Aug.
Artículo en Alemán | MEDLINE | ID: mdl-32495010

RESUMEN

BACKGROUND: On 31 December 2018, the new Radiation Protection Regulation came into effect in Germany and made the new Radiation Protection Act more concrete. The old Radiation Protection Regulation and X­ray Regulation have thereby been replaced. OBJECTIVES: The substantial modifications regarding the practical daily routine in radiology are summarized. METHODS: Modifications and innovations of the New Radiation Protection Act and Regulation compared to the old Radiation Protection Regulation and X­ray Regulation and accordances were evaluated. Thereby the main focus was in the relevance for workflow in clinical routine. RESULTS AND CONCLUSION: The new legislation contains a number of regulations that provide crucial tools for implementation of radiation protection, quality assurance, and dose optimization. However, this also requires additional time and personnel.


Asunto(s)
Protección Radiológica/legislación & jurisprudencia , Radiología/organización & administración , Flujo de Trabajo , Alemania , Humanos
19.
Pediatr Radiol ; 50(1): 28-37, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31583441

RESUMEN

BACKGROUND: The acquisition of chest radiographs in neonates is of critical importance in diagnostics because of the risk of respiratory distress syndrome and pneumothorax in preterm infants. OBJECTIVE: To achieve a dose reduction while preserving a diagnostic image quality for chest radiographs of neonates. MATERIALS AND METHODS: All radiographs, generated on a fully digital X-ray unit by using a neonatal chest phantom, were evaluated under variation of the tube voltage (40-70 kV) and mAs levels (1-10.2 mAs) with and without an additional 0.1-mm copper (Cu) filtration. Noise, contrast and contrast-to-noise ratio for bronchus, heart, lungs and vessels were determined. Visual assessment of the image quality was carried out by three radiologists using a Likert scale. To evaluate a maximally possible dose reduction, the dose of the radiographs with still acceptable image quality at a minimal dose was compared to the dose of the radiographs with the standard settings used in clinical routine. RESULTS: The noise showed decreasing values with increasing dose, while the contrast values were increased. For the contrast-to-noise ratio, a digressive course of the values as a function of the tube voltage was found. The visual evaluation of image quality showed the best evaluation of the structures at the lowest possible dose in the settings (44 kV, 3.36 mAs) with copper filtration and in the settings (44 kV, 1.56 mAs) without copper filtration. A maximum dose reduction from 8.29 µSv to 2.21 µSv (about 73%) was obtained. CONCLUSION: A dose reduction while preserving diagnostic image quality in a digital X-ray system is generally possible by reducing the tube voltage and simultaneous adaptation of the mAs settings.


Asunto(s)
Pulmón/diagnóstico por imagen , Fantasmas de Imagen , Dosis de Radiación , Radiografía Torácica/métodos , Humanos , Recién Nacido
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...