1.
Acta Anaesthesiol Scand ; 67(2): 185-194, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36268561

RESUMEN

BACKGROUND: Gravity-dependent positioning therapy is an established concept in the treatment of severe acute respiratory distress syndrome and improves oxygenation in spontaneously breathing patients with hypoxemic acute respiratory failure. In patients with coronavirus disease 2019, this therapy seems to be less effective. Electrical impedance tomography as a point-of-care functional imaging modality for visualizing regional ventilation can possibly help identify patients who might benefit from positioning therapy and guide those maneuvers in real-time. Therefore, in this prospective observational study, we aimed to discover typical patterns in response to positioning maneuvers. METHODS: Distribution of ventilation in 10 healthy volunteers and in 12 patients with hypoxemic respiratory failure due to coronavirus disease 2019 was measured in supine, left, and right lateral positions using electrical impedance tomography. RESULTS: In this study, patients with coronavirus disease 2019 showed a variety of ventilation patterns, which were not predictable, whereas all but one healthy volunteer showed a typical and expected gravity-dependent distribution of ventilation with the body positions. CONCLUSION: Distribution of ventilation and response to lateral positioning is variable and thus unpredictable in spontaneously breathing patients with coronavirus disease 2019. Electrical impedance tomography might add useful information on the immediate reaction to postural maneuvers and should be elucidated further in clinical studies. Therefore, we suggest a customized individualized positioning therapy guided by electrical impedance tomography.


Asunto(s)
COVID-19 , Insuficiencia Respiratoria , Humanos , Impedancia Eléctrica , Tomografía/métodos , COVID-19/terapia , Respiración , Tomografía Computarizada por Rayos X
2.
Respir Care ; 67(8): 906-913, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35610029

RESUMEN

BACKGROUND: To analyze the role of PEEP on dynamic relative regional strain (DRRS) in a model of ARDS, respective maps were generated by electrical impedance tomography (EIT). METHODS: Eight ARDS pigs submitted to PEEP steps of 0, 5, 10, and 15 cm H2O at fixed ventilation were evaluated by EIT images. DRRS was calculated as (VT-EIT/EELI)/(VT-EIT[15PEEP]/EELI[15PEEP]), where the tidal volume (VT)-EIT and end-expiratory lung impedance (EELI) are the tidal and end-expiratory change in lung impedance, respectively. The measurement at 15 PEEP was taken as reference (end-expiratory transpulmonary pressure > 0 cm H2O). The relationship between EIT variables (center of ventilation, EELI, and DRRS) and airway pressures was assessed with mixed-effects models using EIT measurements as dependent variables and PEEP as fixed-effect variable. RESULTS: At constant ventilation, respiratory compliance increased progressively with PEEP (lowest value at zero PEEP 10 ± 3 mL/cm H2O and highest value at 15 PEEP 16 ± 6 mL/cm H2O; P < .001), whereas driving pressure decreased with PEEP (highest value at zero PEEP 34 ± 6 cm H2O and lowest value at 15 PEEP 21 ± 4 cm H2O; P < .001). The mixed-effect regression models showed that the center of ventilation moved to dorsal lung areas with a slope of 1.81 (1.44-2.18) % points by each cm H2O of PEEP; P < .001. EELI increased with a slope of 0.05 (0.02-0.07) (arbitrary units) for each cm H2O of PEEP; P < .001. DRRS maps showed that local strain in ventral lung areas decreased with a slope of -0.02 (-0.24 to 0.15) with each cm H2O increase of PEEP; P < .001. CONCLUSIONS: EIT-derived DRRS maps showed high strain in ventral lung zones at low levels of PEEP. The findings suggest overdistention of the baby lung.


Asunto(s)
Respiración con Presión Positiva , Síndrome de Dificultad Respiratoria , Animales , Impedancia Eléctrica , Pulmón/diagnóstico por imagen , Modelos Teóricos , Respiración con Presión Positiva/métodos , Síndrome de Dificultad Respiratoria/diagnóstico por imagen , Síndrome de Dificultad Respiratoria/terapia , Porcinos , Volumen de Ventilación Pulmonar , Tomografía/métodos , Tomografía Computarizada por Rayos X
3.
J Clin Monit Comput ; 36(4): 975-985, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-34386896

RESUMEN

Respiratory failure due to SARS-CoV-2 may progress rapidly. During the course of COVID-19, patients develop an increased respiratory drive, which may induce high mechanical strain a known risk factor for Patient Self-Inflicted Lung Injury (P-SILI). We developed a novel Electrical Impedance Tomography-based approach to visualize the Dynamic Relative Regional Strain (DRRS) in SARS-CoV-2 positive patients and compared these findings with measurements in lung healthy volunteers. DRRS was defined as the ratio of tidal impedance changes and end-expiratory lung impedance within each pixel of the lung region. DRRS values of the ten patients were considerably higher than those of the ten healthy volunteers. On repeated examination, patterns, magnitude and frequency distribution of DRRS were reproducible and in line with the clinical course of the patients. Lung ultrasound scores correlated with the number of pixels showing DRRS values above the derived threshold. Using Electrical Impedance Tomography we were able to generate, for the first time, images of DRRS which might indicate P-SILI in patients suffering from COVID-19.Trial Registration This observational study was registered 06.04.2020 in German Clinical Trials Register (DRKS00021276).


Asunto(s)
COVID-19 , Tomografía , Impedancia Eléctrica , Humanos , Pulmón/diagnóstico por imagen , Respiración con Presión Positiva/métodos , SARS-CoV-2 , Tomografía/métodos
4.
Biomedicines ; 9(9)2021 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-34572397

RESUMEN

For the non-invasive assessment of pulmonary artery pressure (PAP), surrogates like pulse wave transit time (PWTT) have been proposed. The aim of this study was to invasively validate for which kind of PAP (systolic, mean, or diastolic) PWTT is the best surrogate parameter. To assess both PWTT and PAP in six healthy pigs, two pulmonary artery Mikro-Tip™ catheters were inserted into the pulmonary vasculature at a fixed distance: one in the pulmonary artery trunk, and a second one in a distal segment of the pulmonary artery. PAP was raised using the thromboxane A2 analogue U46619 (TXA) and by hypoxic vasoconstriction. There was a negative linear correlation between PWTT and systolic PAP (r = 0.742), mean PAP (r = 0.712) and diastolic PAP (r = 0.609) under TXA. During hypoxic vasoconstriction, the correlation coefficients for systolic, mean, and diastolic PAP were consistently higher than for TXA-induced pulmonary hypertension (r = 0.809, 0.778 and 0.734, respectively). Estimation of sPAP, mPAP, and dPAP using PWTT is feasible, nevertheless slightly better correlation coefficients were detected for sPAP compared to dPAP. In this study we establish the physiological basis for future methods to obtain PAP by non-invasively measured PWTT.

5.
Angew Chem Int Ed Engl ; 57(28): 8765-8769, 2018 07 09.
Artículo en Inglés | MEDLINE | ID: mdl-29732658

RESUMEN

Upconversion core/shell nanocrystals with different mean sizes ranging from 15 to 45 nm were prepared via a modified synthesis procedure based on anhydrous rare-earth acetates. All particles consist of a core of NaYF4 :Yb,Er, doped with 18 % Yb3+ and 2 % Er3+ , and an inert shell of NaYF4 , with the shell thickness being equal to the radius of the core particle. Absolute measurements of the photoluminescence quantum yield at a series of different excitation power densities show that the quantum yield of 45 nm core/shell particles is already very close to the quantum yield of microcrystalline upconversion phosphor powder. Smaller core/shell particles prepared by the same method show only a moderate decrease in quantum yield. The quantum yield of 15 nm core/shell particles, for instance, is reduced by a factor of three compared to the bulk upconversion phosphor at high power densities (100 W cm-2 ) and by approximately a factor of 10 at low power densities (1 W cm-2 ).