Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Synchrotron Radiat ; 28(Pt 1): 131-145, 2021 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-33399562

RESUMEN

In this paper the back-side-illuminated Percival 2-Megapixel (P2M) detector is presented, along with its characterization by means of optical and X-ray photons. For the first time, the response of the system to soft X-rays (250 eV to 1 keV) is presented. The main performance parameters of the first detector are measured, assessing the capabilities in terms of noise, dynamic range and single-photon discrimination capability. Present limitations and coming improvements are discussed.

2.
Nat Commun ; 11(1): 4511, 2020 09 09.
Artículo en Inglés | MEDLINE | ID: mdl-32908128

RESUMEN

Serial femtosecond crystallography (SFX) with X-ray free electron lasers (XFELs) allows structure determination of membrane proteins and time-resolved crystallography. Common liquid sample delivery continuously jets the protein crystal suspension into the path of the XFEL, wasting a vast amount of sample due to the pulsed nature of all current XFEL sources. The European XFEL (EuXFEL) delivers femtosecond (fs) X-ray pulses in trains spaced 100 ms apart whereas pulses within trains are currently separated by 889 ns. Therefore, continuous sample delivery via fast jets wastes >99% of sample. Here, we introduce a microfluidic device delivering crystal laden droplets segmented with an immiscible oil reducing sample waste and demonstrate droplet injection at the EuXFEL compatible with high pressure liquid delivery of an SFX experiment. While achieving ~60% reduction in sample waste, we determine the structure of the enzyme 3-deoxy-D-manno-octulosonate-8-phosphate synthase from microcrystals delivered in droplets revealing distinct structural features not previously reported.


Asunto(s)
Cristalografía/instrumentación , Electrones , Dispositivos Laboratorio en un Chip , Rayos Láser , Aldehído-Liasas/ultraestructura , Proteínas de Escherichia coli/ultraestructura , Hidrodinámica
3.
J Appl Crystallogr ; 53(Pt 4): 927-936, 2020 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-32788900

RESUMEN

The ever-increasing brightness of synchrotron radiation sources demands improved X-ray optics to utilize their capability for imaging and probing biological cells, nano-devices and functional matter on the nanometre scale with chemical sensitivity. Hard X-rays are ideal for high-resolution imaging and spectroscopic applications owing to their short wavelength, high penetrating power and chemical sensitivity. The penetrating power that makes X-rays useful for imaging also makes focusing them technologically challenging. Recent developments in layer deposition techniques have enabled the fabrication of a series of highly focusing X-ray lenses, known as wedged multi-layer Laue lenses. Improvements to the lens design and fabrication technique demand an accurate, robust, in situ and at-wavelength characterization method. To this end, a modified form of the speckle tracking wavefront metrology method has been developed. The ptychographic X-ray speckle tracking method is capable of operating with highly divergent wavefields. A useful by-product of this method is that it also provides high-resolution and aberration-free projection images of extended specimens. Three separate experiments using this method are reported, where the ray path angles have been resolved to within 4 nrad with an imaging resolution of 45 nm (full period). This method does not require a high degree of coherence, making it suitable for laboratory-based X-ray sources. Likewise, it is robust to errors in the registered sample positions, making it suitable for X-ray free-electron laser facilities, where beam-pointing fluctuations can be problematic for wavefront metrology.

5.
Struct Dyn ; 6(6): 064702, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31832488

RESUMEN

The new European X-ray Free-Electron Laser (European XFEL) is the first X-ray free-electron laser capable of delivering intense X-ray pulses with a megahertz interpulse spacing in a wavelength range suitable for atomic resolution structure determination. An outstanding but crucial question is whether the use of a pulse repetition rate nearly four orders of magnitude higher than previously possible results in unwanted structural changes due to either radiation damage or systematic effects on data quality. Here, separate structures from the first and subsequent pulses in the European XFEL pulse train were determined, showing that there is essentially no difference between structures determined from different pulses under currently available operating conditions at the European XFEL.

6.
Nat Commun ; 10(1): 5021, 2019 11 04.
Artículo en Inglés | MEDLINE | ID: mdl-31685819

RESUMEN

The world's first superconducting megahertz repetition rate hard X-ray free-electron laser (XFEL), the European XFEL, began operation in 2017, featuring a unique pulse train structure with 886 ns between pulses. With its rapid pulse rate, the European XFEL may alleviate some of the increasing demand for XFEL beamtime, particularly for membrane protein serial femtosecond crystallography (SFX), leveraging orders-of-magnitude faster data collection. Here, we report the first membrane protein megahertz SFX experiment, where we determined a 2.9 Å-resolution SFX structure of the large membrane protein complex, Photosystem I, a > 1 MDa complex containing 36 protein subunits and 381 cofactors. We address challenges to megahertz SFX for membrane protein complexes, including growth of large quantities of crystals and the large molecular and unit cell size that influence data collection and analysis. The results imply that megahertz crystallography could have an important impact on structure determination of large protein complexes with XFELs.


Asunto(s)
Electrones , Rayos Láser , Proteínas de la Membrana/química , Cristalografía , Cianobacterias/metabolismo , Modelos Moleculares , Complejo de Proteína del Fotosistema I/química , Complejo de Proteína del Fotosistema I/aislamiento & purificación , Electricidad Estática , Sincrotrones , Thermosynechococcus , Rayos X
7.
J Synchrotron Radiat ; 26(Pt 5): 1448-1461, 2019 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-31490132

RESUMEN

The Karabo distributed control system has been developed to address the challenging requirements of the European X-ray Free Electron Laser facility, including complex and custom-made hardware, high data rates and volumes, and close integration of data analysis for distributed processing and rapid feedback. Karabo is a pluggable, distributed application management system forming a supervisory control and data acquisition environment as part of a distributed control system. Karabo provides integrated control of hardware, monitoring, data acquisition and data analysis on distributed hardware, allowing rapid control feedback based on complex algorithms. Services exist for access control, data logging, configuration management and situational awareness through alarm indicators. The flexible framework enables quick response to the changing requirements in control and analysis, and provides an efficient environment for development, and a single interface to make all changes immediately available to operators and experimentalists.

8.
J Synchrotron Radiat ; 26(Pt 1): 74-82, 2019 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-30655470

RESUMEN

The Adaptive Gain Integrating Pixel Detector (AGIPD) is an X-ray imager, custom designed for the European X-ray Free-Electron Laser (XFEL). It is a fast, low-noise integrating detector, with an adaptive gain amplifier per pixel. This has an equivalent noise of less than 1 keV when detecting single photons and, when switched into another gain state, a dynamic range of more than 104 photons of 12 keV. In burst mode the system is able to store 352 images while running at up to 6.5 MHz, which is compatible with the 4.5 MHz frame rate at the European XFEL. The AGIPD system was installed and commissioned in August 2017, and successfully used for the first experiments at the Single Particles, Clusters and Biomolecules (SPB) experimental station at the European XFEL since September 2017. This paper describes the principal components and performance parameters of the system.

9.
Light Sci Appl ; 7: 17162, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30839543

RESUMEN

Multilayer Laue lenses are volume diffraction elements for the efficient focusing of X-rays. With a new manufacturing technique that we introduced, it is possible to fabricate lenses of sufficiently high numerical aperture (NA) to achieve focal spot sizes below 10 nm. The alternating layers of the materials that form the lens must span a broad range of thicknesses on the nanometer scale to achieve the necessary range of X-ray deflection angles required to achieve a high NA. This poses a challenge to both the accuracy of the deposition process and the control of the materials properties, which often vary with layer thickness. We introduced a new pair of materials-tungsten carbide and silicon carbide-to prepare layered structures with smooth and sharp interfaces and with no material phase transitions that hampered the manufacture of previous lenses. Using a pair of multilayer Laue lenses (MLLs) fabricated from this system, we achieved a two-dimensional focus of 8.4 × 6.8 nm2 at a photon energy of 16.3 keV with high diffraction efficiency and demonstrated scanning-based imaging of samples with a resolution well below 10 nm. The high NA also allowed projection holographic imaging with strong phase contrast over a large range of magnifications. An error analysis indicates the possibility of achieving 1 nm focusing.

10.
IUCrJ ; 4(Pt 6): 769-777, 2017 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-29123679

RESUMEN

Unravelling the interaction of biological macromolecules with ligands and substrates at high spatial and temporal resolution remains a major challenge in structural biology. The development of serial crystallography methods at X-ray free-electron lasers and subsequently at synchrotron light sources allows new approaches to tackle this challenge. Here, a new polyimide tape drive designed for mix-and-diffuse serial crystallography experiments is reported. The structure of lysozyme bound by the competitive inhibitor chitotriose was determined using this device in combination with microfluidic mixers. The electron densities obtained from mixing times of 2 and 50 s show clear binding of chitotriose to the enzyme at a high level of detail. The success of this approach shows the potential for high-throughput drug screening and even structural enzymology on short timescales at bright synchrotron light sources.

11.
J Appl Crystallogr ; 49(Pt 3): 1073-1080, 2016 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-27275150

RESUMEN

This article describes a free and open-source data analysis utility designed for fast online feedback during serial X-ray diffraction and scattering experiments: OnDA (online data analysis). Three complete real-time monitors for common types of serial X-ray imaging experiments are presented. These monitors are capable of providing the essential information required for quick decision making in the face of extreme rates of data collection. In addition, a set of modules, functions and algorithms that allow developers to modify the provided monitors or develop new ones are provided. The emphasis here is on simple, modular and scalable code that is based on open-source libraries and protocols. OnDA monitors have already proven to be invaluable tools in several experiments, especially for scoring and monitoring of diffraction data during serial crystallography experiments at both free-electron laser and synchrotron facilities. It is felt that in the future the kind of fast feedback that OnDA monitors provide will help researchers to deal with the expected very high throughput data flow at next-generation facilities such as the European X-ray free-electron laser.

12.
Berl Munch Tierarztl Wochenschr ; 125(7-8): 351-8, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22919930

RESUMEN

Equine typholocolitis is a sporadic diarrheal disease causing high mortality rates. One of the risk factors responsible for this is the oral application of the macrolide antibiotic erythromycin. The aim of the present in vitro study was to investigate whether erythromycin in combination with feed restriction provokes changes in microbial hindgut metabolism and could therefore be involved in the pathogenesis of equine typhlocolitis. As application of erythromycin and feed restriction are risk factors for equine typhlocolitis, both factors were chosen to investigate their individual and combined effects on hindgut microbial metabolism. The colon simulation technique (Cositec) was used to evaluate biochemical parameters of microbial metabolism. Production rates of the acetate, proprionate and butyrate were measured as quantitative parameters of microbial fermentation. Application of erythromycin (10 mg/d) predominantly decreased the production rates of propionate. Reducing the fermentable substrate to 30% induced an even more pronounced impairment. The detrimental effects of feed restriction on the production rates of short-chain fatty acids (SCFA) were enhanced when feed restriction was combined with the application of erythromycin. Irrespective of erytrhomycin, the butyrate fermentation rate was completely inhibited by feed restriction within two days after start of restriction. The reduction in butyrate fermentation rate has to be discussed as a pathophysiological factor for the onset of acute typhlocolitis.


Asunto(s)
Antibacterianos/farmacología , Ciego/microbiología , Colitis/veterinaria , Ingestión de Alimentos/fisiología , Eritromicina/farmacología , Enfermedades de los Caballos/etiología , Alimentación Animal , Animales , Antibacterianos/uso terapéutico , Ciego/efectos de los fármacos , Ciego/metabolismo , Colitis/tratamiento farmacológico , Colitis/etiología , Colitis/microbiología , Colon/efectos de los fármacos , Colon/metabolismo , Colon/microbiología , Eritromicina/uso terapéutico , Ácidos Grasos Volátiles/metabolismo , Fermentación , Contenido Digestivo/efectos de los fármacos , Contenido Digestivo/microbiología , Enfermedades de los Caballos/tratamiento farmacológico , Enfermedades de los Caballos/microbiología , Caballos , Técnicas In Vitro , Factores de Riesgo
13.
Eur Arch Psychiatry Clin Neurosci ; 256(8): 497-503, 2006 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-16917684

RESUMEN

The purpose of this study was to prospectively investigate the onset, course, and remission of psychiatric disorders in the first 6 months after a serious accident for consecutive patients in a hospital emergency department. Participants were 58 patients aged 18-65 who were assessed shortly after attending a hospital emergency department and were followed up 6 months afterwards. Patients were interviewed with regard to past and current psychiatric history using different instruments (e.g. SCID for DSM-IV). Prior to their accidents, 35% of all subjects had experienced one or more psychiatric disorders (lifetime prevalence). Shortly after the accident, the incidence of Acute Stress Disorder (7%), subsyndromal Acute Stress Disorder (12%), and adjustment disorder (1.5%) was increased as a reaction to the accident. At this time, 29% of all patients suffered from an acute psychiatric disorder. Six-months after the accident, 10% of the subjects met criteria for Major Depression, 6% for PTSD, 4% for subsyndromal PTSD, and 1.5% for Specific Phobia as newly developed disorders. The course of the psychiatric disorders shows that those patients who met criteria for any psychiatric diagnosis shortly after the accident ran a much higher risk for developing new or comorbid psychiatric disorders in the future.


Asunto(s)
Accidentes Domésticos/psicología , Accidentes de Trabajo/psicología , Accidentes de Tránsito/psicología , Trastornos de Ansiedad/diagnóstico , Trastorno Depresivo/diagnóstico , Trastornos por Estrés Postraumático/diagnóstico , Heridas y Lesiones/psicología , Escala Resumida de Traumatismos , Trastornos de Adaptación/diagnóstico , Trastornos de Adaptación/epidemiología , Trastornos de Adaptación/psicología , Adolescente , Adulto , Anciano , Trastornos de Ansiedad/epidemiología , Trastornos de Ansiedad/psicología , Actitud Frente a la Muerte , Comorbilidad , Estudios Transversales , Trastorno Depresivo/epidemiología , Trastorno Depresivo/psicología , Trastorno Depresivo Mayor/diagnóstico , Trastorno Depresivo Mayor/epidemiología , Trastorno Depresivo Mayor/psicología , Miedo , Femenino , Estudios de Seguimiento , Alemania , Humanos , Masculino , Persona de Mediana Edad , Trastornos Fóbicos/diagnóstico , Trastornos Fóbicos/epidemiología , Trastornos Fóbicos/psicología , Factores de Riesgo , Trastornos por Estrés Postraumático/epidemiología , Trastornos por Estrés Postraumático/psicología , Heridas y Lesiones/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...