Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Más filtros












Intervalo de año de publicación
1.
J Mech Behav Biomed Mater ; 104: 103668, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32174426

RESUMEN

Information on the adaptation of bone structures during evolution is rare since histological data are limited. Micro- and nano-computed tomography of a fossilized vertebra from Champsosaurus sp., which has an estimated age of 70-73 million years, revealed lower porosity and higher bone density compared to modern Crocodylidae vertebrae. Mid-infrared reflectance and energy dispersive X-ray mapping excluded a petrification process, and demonstrated a typical carbonate apatite distribution, confirming histology in light- and electron microscopy of the preserved vertebra. As a consequence of this evolutionary process, the two vertebrae of modern Crocodylidae show reduced overall stiffness in the finite element analysis simulation compared to the fossilized Champsosaurus sp. vertebra, with predominant stiffness along the longitudinal z-axes.


Asunto(s)
Fósiles , Columna Vertebral , Densidad Ósea , Simulación por Computador , Análisis de Elementos Finitos , Vértebras Lumbares/anatomía & histología , Columna Vertebral/diagnóstico por imagen , Tomografía Computarizada por Rayos X
2.
Anal Methods ; 7(7): 2917-2927, 2015 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-25878731

RESUMEN

In this study different state-of-the-art visualization methods such as micro-computed tomography (micro-CT), mid-infrared (MIR) microscopic imaging and energy dispersive X-ray (EDS) mapping were evaluated to study human skeletal remains for the determination of the post-mortem interval (PMI). PMI specific features were identified and visualized by overlaying molecular imaging data and morphological tissue structures generated by radiological techniques and microscopic images gained from confocal microscopy (Infinite Focus (IFM)). In this way, a more distinct picture concerning processes during the PMI as well as a more realistic approximation of the PMI were achieved. It could be demonstrated that the gained result in combination with multivariate data analysis can be used to predict the Ca/C ratio and bone volume (BV) over total volume (TV) for PMI estimation. Statistical limitation of this study is the small sample size, and future work will be based on more specimens to develop a screening tool for PMI based on the outcome of this multidimensional approach.

3.
Osteoporos Int ; 25(4): 1285-96, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24306231

RESUMEN

UNLABELLED: Whole vertebrae areal and volumetric bone mineral density (BMD) measurements are not ideal predictors of vertebral fractures. We introduce a technique which enables quantification of bone microstructural parameters at precisely defined anatomical locations. Results show that local assessment of bone volume fraction at the optimal location can substantially improve the prediction of vertebral strength. INTRODUCTION: Whole vertebrae areal and volumetric BMD measurements are not ideal predictors of vertebral osteoporotic fractures. Recent studies have shown that sampling bone microstructural parameters in smaller regions may permit better predictions. In such studies, however, the sampling location is described only in general anatomical terms. Here, we introduce a technique that enables the quantification of bone volume fraction and microstructural parameters at precisely defined anatomical locations. Specific goals of this study were to investigate at what anatomical location within the vertebrae local bone volume fraction best predicts vertebral-body strength, whether this prediction can be improved by adding microstructural parameters and to explore if this approach could better predict vertebral-body strength than whole bone volume fraction and finite element (FE) analyses. METHODS: Eighteen T12 vertebrae were scanned in a micro-computed tomography (CT) system and FE meshes were made using a mesh-morphing tool. For each element, bone microstructural parameters were measured and correlated with vertebral compressive strength as measured experimentally. Whole bone volume fraction and FE-predicted vertebral strength were also compared to the experimental measurements. RESULTS: A significant association between local bone volume fraction measured at a specific central region and vertebral-body strength was found that could explain up to 90% of the variation. When including all microstructural parameters in the regression, the predictive value of local measurements could be increased to 98%. Whole bone volume fraction could explain only 64% and FE analyses 76% of the variation in bone strength. CONCLUSIONS: A local assessment of volume fraction at the optimal location can substantially improve the prediction of bone strength. Local assessment of other microstructural parameters may further improve this prediction but is not clinically feasible using current technology.


Asunto(s)
Densidad Ósea/fisiología , Vértebras Torácicas/patología , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Fuerza Compresiva/fisiología , Femenino , Análisis de Elementos Finitos , Humanos , Masculino , Persona de Mediana Edad , Fracturas Osteoporóticas/diagnóstico por imagen , Fracturas Osteoporóticas/fisiopatología , Valor Predictivo de las Pruebas , Fracturas de la Columna Vertebral/diagnóstico por imagen , Fracturas de la Columna Vertebral/fisiopatología , Vértebras Torácicas/diagnóstico por imagen , Vértebras Torácicas/fisiopatología , Microtomografía por Rayos X/métodos
4.
Calcif Tissue Int ; 83(4): 293-9, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18839046

RESUMEN

Bone mass predicts a high proportion of variability in bone failure strength but is known to overlap among subjects with and without fractures. Here, we tested the hypothesis that trabecular bone microstructure, determined with micro-computed tomography (microCT), can improve the prediction of experimental failure loads in the distal forearm compared with bone mass alone. The right forearm and left distal radius of 130 human specimens were examined. Bone mineral density (BMD) was measured with peripheral dual energy X-ray absorptiometry (DXA). The specimens were mechanically tested to failure in a fall configuration, with the hand, elbow, ligaments, and tendons intact. Cylindrical bone samples from the metaphysis of the contralateral distal radius were obtained adjacent to the subchondral bone plate and scanned with microCT. When analyzing the total sample, BMD of the distal radius displayed a correlation of r = 0.82 with mechanical failure loads. After excluding 21 specimens with no obvious radiological sign of fracture after the test, the correlation increased to r = 0.85. When only including 79 specimens with loco typico fractures, the correlation was r = 0.82. The microstructural parameters showed correlation coefficients with the failure loads of < or =0.55 and did not add significant information to DXA in predicting failure loads in multiple regression models. These findings suggest that, under experimental conditions of mechanically testing entire bones, measurement of bone microstructure does not improve the prediction of distal radius bone strength. Determination of bone microstructure may thus be less promising in improving the prediction of fractures than commonly assumed.


Asunto(s)
Densidad Ósea , Fracturas del Radio/etiología , Radio (Anatomía)/fisiología , Radio (Anatomía)/ultraestructura , Absorciometría de Fotón , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Radio (Anatomía)/diagnóstico por imagen , Fracturas del Radio/diagnóstico por imagen , Estrés Mecánico , Microtomografía por Rayos X
5.
J Bone Joint Surg Br ; 90(1): 103-6, 2008 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-18160510

RESUMEN

Operative fixation is the treatment of choice for a rupture of the distal tendon of biceps. A variety of techniques have been described including transosseous sutures and suture anchors. The poor quality of the bone of the radial tuberosity might affect the load to failure of the tendon repair in early rehabilitation. The aim of this study was to determine the loads to failure of different techniques of fixation and to investigate their association with the bone mineral density of the radial tuberosity. Peripheral quantitative computed tomography was carried out to measure the trabecular and cortical bone mineral density of the radial tuberosity in 40 cadaver specimens. The loads to failure in four different techniques of fixation were determined. The Endobutton-based method showed the highest failure load at 270 N (sd 22) (p < 0.05). The mean failure load of the transosseous suture technique was 210 N (sd 66) and that of the TwinFix-QuickT 5.0 mm was 57 N (sd 22), significantly lower than those of all other repairs (p < 0.05). No significant correlation was seen between bone mineral density and loads to failure. The transosseous technique is an easy and cost-saving procedure for fixation of the distal biceps tendon. TwinFix-QuickT 5.0 mm had significantly lower failure loads, which might affect early rehabilitation, particularly in older patients.


Asunto(s)
Procedimientos Ortopédicos/métodos , Técnicas de Sutura , Traumatismos de los Tendones/cirugía , Anciano , Anciano de 80 o más Años , Brazo , Densidad Ósea , Cadáver , Femenino , Humanos , Masculino , Persona de Mediana Edad , Músculo Esquelético/fisiopatología , Músculo Esquelético/cirugía , Radio (Anatomía)/química , Rotura/cirugía , Traumatismos de los Tendones/fisiopatología , Resistencia a la Tracción , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
6.
Osteoporos Int ; 19(4): 547-58, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-17891327

RESUMEN

UNLABELLED: Computerized analysis of the trabecular structure was used to test whether femur failure load can be estimated from radiographs. The study showed that combined analysis of trabecular bone structure and geometry predicts in vitro failure load with similar accuracy as DXA. INTRODUCTION: Since conventional radiography is widely available with low imaging cost, it is of considerable interest to discover how well bone mechanical competence can be determined using this technology. We tested the hypothesis that the mechanical strength of the femur can be estimated by the combined analysis of the bone trabecular structure and geometry. METHODS: The sample consisted of 62 cadaver femurs (34 females, 28 males). After radiography and DXA, femora were mechanically tested in side impact configuration. Fracture patterns were classified as being cervical or trochanteric. Computerized image analysis was applied to obtain structure-related trabecular parameters (trabecular bone area, Euler number, homogeneity index, and trabecular main orientation), and set of geometrical variables (neck-shaft angle, medial calcar and femoral shaft cortex thicknesses, and femoral neck axis length). Multiple linear regression analysis was performed to identify the variables that best explain variation in BMD and failure load between subjects. RESULTS: In cervical fracture cases, trabecular bone area and femoral neck axis length explained 64% of the variability in failure loads, while femoral neck BMD also explained 64%. In trochanteric fracture cases, Euler number and femoral cortex thickness explained 66% of the variability in failure load, while trochanteric BMD explained 72%. CONCLUSIONS: Structural parameters of trabecular bone and bone geometry predict in vitro failure loads of the proximal femur with similar accuracy as DXA, when using appropriate image analysis technology.


Asunto(s)
Densidad Ósea/fisiología , Fémur/fisiología , Osteoporosis/fisiopatología , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos/economía , Cadáver , Femenino , Fémur/anatomía & histología , Humanos , Modelos Logísticos , Masculino , Estrés Mecánico , Tomografía Computarizada por Rayos X/economía , Tomografía Computarizada por Rayos X/métodos
7.
Osteoporos Int ; 16(9): 1124-33, 2005 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-15744451

RESUMEN

High-resolution magnetic resonance imaging (hrMRI) has recently made it possible to evaluate trabecular bone structure in vivo. Despite obvious gender differences in fracture incidence at the distal radius, little is known about gender differences in trabecular bone microarchitecture and its relationship to the structural strength of the forearm. The aim of this study was to determine trabecular bone structure in the distal radius of elderly women and men and its correlation with failure loads of the distal radius as determined in a fall configuration. Specifically, we tested the hypotheses that structural indices differ between women and men and that they offer information that is independent from BMD for predicting structural strength. Intact right arms were obtained from 73 formalin-fixed cadavers (age 80+/-11 years, 43 women, 30 men). Trabecular structural indices (apparent bone volume fraction [app. BV/TV], trabecular number [app. Tb.N], trabecular separation [app. Tb.Sp], trabecular thickness [app. Tb.Th] and fractal dimension [Frac.Dim]) were assessed in the distal metaphysis, using hrMRI with 156 microm in-plane resolution and proprietary digital image analysis, while BMD was measured with dual X-ray absorptiometry (DXA). Women displayed significantly lower BMD (-29.8%, p <0.001), app. BV/TV (-8.2%, p <0.05) and app. Tb.Th (-10.2%, p <0.001) than men, whereas app. Tb.N, app. Tb.Sp. and fractal dimension did not differ significantly. Structural parameters differed between normal and osteopenic women (BV/TV: -11%, p <0.01; Tb.Th: -8%, p <0.001) and between normal and osteoporotic women BV/TV: -21%, p <0.001; Tb.Th: -16%, p <0.001). App. BV/TV, app. Tb.Th and fractal dimension provided information independent from BMD in the prediction of radial failure loads in multiple regression models. These findings imply that it should be of clinical interest to monitor both bone mass and trabecular microstructure for predicting osteoporotic fracture risk.


Asunto(s)
Radio (Anatomía)/anatomía & histología , Caracteres Sexuales , Absorciometría de Fotón , Accidentes por Caídas , Anciano , Anciano de 80 o más Años , Antropometría , Fenómenos Biomecánicos , Densidad Ósea , Femenino , Fractales , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Osteoporosis/patología , Osteoporosis/fisiopatología , Osteoporosis Posmenopáusica/patología , Osteoporosis Posmenopáusica/fisiopatología , Radio (Anatomía)/fisiología , Radio (Anatomía)/fisiopatología
8.
Eur Radiol ; 15(4): 784-91, 2005 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15702339

RESUMEN

The objective of this study was to compare the value of multislice CT arthrography and MR arthrography in the assessment of cartilage lesions of the elbow joint. Twenty-six cadaveric elbow specimens were examined with the use of CT arthrography and MR arthrography prior to joint exploration and macroscopic inspection of articular cartilage. Findings at CT and MR arthrography were compared with macroscopic assessments in 104 cartilage areas. At macroscopic inspection, 45 cartilage lesions (six grade 2 lesions, 25 grade 3 lesions, 14 grade 4 lesions) and 59 areas of normal articular cartilage were observed. With macroscopic assessment as the gold standard CT and MR arthrography showed an overall sensitivity/specificity of 80/93% and 78/95% for the detection of cartilage lesions, respectively. Only two of six grade 2 lesions were detected by CT and MR arthrography. For the diagnosis of grade 3 and 4 lesions, the sensitivity/specificity was 87/94% with CT arthrography, and 85/95% with MR arthrography. In an experimental setting multislice CT arthrography and MR arthrography showed a similar performance in the detection of cartilage lesions. Both methods indicated limited value in the diagnosis of grade 2 articular cartilage lesions.


Asunto(s)
Artrografía/métodos , Enfermedades de los Cartílagos/diagnóstico , Cartílago Articular/diagnóstico por imagen , Cartílago Articular/patología , Articulación del Codo , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Anciano , Anciano de 80 o más Años , Cadáver , Humanos , Persona de Mediana Edad
9.
Biomed Tech (Berl) ; 49(9): 248-56, 2004 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-15493133

RESUMEN

Bone transport applying the principle of distraction osteogenesis makes it possible to reconstruct long bone defects caused by trauma or resection of bone tumors. The method employing a central cable, developed in Munich, is especially suitable for such applications. The main bone fragments are stabilized by an external fixateur, and bone transport is effected with a single central cable fixed to the tip of the segment, and driven by an external, programmable motor. In 15 patients the tractive forces during the entire bone transport were measured with a strain gauge incorporated within the cable. On the basis of the force profiles characteristics normal bone transport (forces between 150-250 N) can be distinguished from a critical transport (forces > 250 N) with the risk of premature consolidation. There is some evidence that at a very high level of force, just before premature consolidation a very effective form of bone transport with good bone neoformation can be achieved. Transport systems employing a central cable allow this special form of distraction osteogenesis, since there is continuous force monitoring, and there is the option of employing the traction force as a control factor in a loop.


Asunto(s)
Neoplasias Óseas/cirugía , Regeneración Ósea/fisiología , Fijadores Externos , Fracturas del Fémur/cirugía , Neoplasias Femorales/cirugía , Curación de Fractura/fisiología , Osteogénesis por Distracción/instrumentación , Procesamiento de Señales Asistido por Computador/instrumentación , Tibia/cirugía , Fracturas de la Tibia/cirugía , Adolescente , Adulto , Neoplasias Óseas/fisiopatología , Niño , Femenino , Fracturas del Fémur/fisiopatología , Neoplasias Femorales/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Resistencia al Corte , Estrés Mecánico , Tibia/fisiopatología , Fracturas de la Tibia/fisiopatología
10.
Calcif Tissue Int ; 75(1): 15-22, 2004 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-15037972

RESUMEN

The purpose of this study was to test the effect of repositioning, systematic displacements of the region of interest (ROI), and acquisition parameters (scan mode and integration time) on quantitative analysis of human trabecular bone microstructure at various skeletal sites, using microcomputed tomographic (microCT) technology. We investigated 28 cylindrical specimens of human trabecular bone (length 14 mm, diameter 8 mm) from four skeletal sites (femoral neck, greater trochanter, second lumbar vertebra, and distal radius). These specimens were selected from over 200 microCT measurements, in order to cover a large range of bone volume fraction (BV/TV) observed at each site. Cylindrical ROIs (length 6 mm, diameter 6 mm) were examined twice at an isotropic resolution of 26 microm, 8 weeks apart. In addition, comparative analyses were performed for displacements of the volumes of interest (VOIs) by 1, 2, 3, and 4 mm (83.4%, 66.6%, 50%, and 33.3% overlap), respectively. Eventually, comparative measurements were obtained at different resolution scan modes and integration times. The results show that microCT measurements are highly reproducible (range of the root mean square coefficient variation % (RMS CV%) = 0.64% to 1.29% for BV/TV at different sites). Displacements of the VOI of up to 4 mm generally led to non significant systematic differences in mean values of < 10%. When comparing various combinations of resolution scan modes and integration times, the use of an integration time of 100 ms was found to be preferable for determining microstructural parameters from human samples with this microCT scanner.


Asunto(s)
Anatomía Transversal/métodos , Huesos/anatomía & histología , Procesamiento de Imagen Asistido por Computador , Tomografía/métodos , Anciano , Anciano de 80 o más Años , Anatomía Transversal/instrumentación , Cadáver , Femenino , Fémur/anatomía & histología , Cuello Femoral/anatomía & histología , Humanos , Vértebras Lumbares/anatomía & histología , Masculino , Persona de Mediana Edad , Radio (Anatomía)/anatomía & histología , Reproducibilidad de los Resultados , Tomografía/instrumentación
11.
Osteoporos Int ; 15(5): 375-81, 2004 May.
Artículo en Inglés | MEDLINE | ID: mdl-14740151

RESUMEN

The diagnosis of osteoporosis is generally based on the assessment of bone mineral content with dual X-ray absorptiometry (DXA) but does not account for the spatial distribution and inherent material properties of the tissue. Peripheral quantitative computed tomography (pQCT) permits one to measure the compartment-specific density and geometry-based parameters of cortical bone. Quantitative ultrasound (QUS) parameters are associated with material properties of cortical bone. The purpose of this study was to test the hypothesis that pQCT and cortical QUS provide additional information to DXA in predicting structural strength of the distal radius. The intact right arm and the isolated left radius were harvested from 70 formalin-fixed cadavers (age 79+/-11 years). The bone mineral content (BMC) was assessed with DXA at the radial metaphysis and shaft. pQCT was also used at the metaphysis and the shaft, while QUS was employed only at the shaft. The failure loads of the radius were assessed by use of a 3-point bending test (isolated radius) and a complex fall simulation (intact arm). The BMC (DXA) displayed a correlation of r=0.96 with the failure moments in 3-point bending ( P<0.001). The correlation between failure load and geometry-based parameters (pQCT) ranged from r=0.85 to r=0.96 and was r=0.64 for the speed of sound (QUS) ( P <0.001). Cortical thickness (pQCT) improved the prediction marginally (r=0.964) in combination with DXA. For the fall simulation, the correlation coefficients were r=0.76 for BMC (DXA) of the shaft, r=0.83 for metaphyseal bone content (pQCT), r=0.55 for QUS, and ranged from r=0.59 to r=0.74 for geometry-based parameters at the shaft (pQCT). pQCT and QUS parameters provided no significant improvement versus DXA alone. Measurement of bone mass by DXA or pQCT thus appears to be sufficient as a surrogate of mechanical strength and fracture risk of the distal radius.


Asunto(s)
Osteoporosis/diagnóstico , Radio (Anatomía)/fisiopatología , Absorciometría de Fotón , Anciano , Anciano de 80 o más Años , Densidad Ósea , Femenino , Humanos , Masculino , Persona de Mediana Edad , Modelos Anatómicos , Osteoporosis/diagnóstico por imagen , Radio (Anatomía)/diagnóstico por imagen , Estrés Mecánico , Tomografía Computarizada por Rayos X , Ultrasonografía
12.
Bone ; 31(1): 77-84, 2002 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-12110416

RESUMEN

The objective of this study was to compare the ability of clinically available densitometric measurement techniques for evaluating vertebral strength in elderly individuals. Measurements were related to experimentally determined failure strength in the thoracic and lumbar spine. In 127 specimens (82 women and 45 men, age 80 +/- 10 years), dual-energy X-ray absorptiometry (DXA) was performed at the lumbar spine, femur, radius, and total body, and peripheral-quantitative computed tomography (pQCT) at the distal radius, tibia, and femur under in situ conditions with intact soft tissues. Spinal QCT and calcaneal ultrasound parameters were performed ex situ in degassed specimens. Mechanical failure loads of thoracic vertebrae 6 and 10 (T-6 and -10), and lumbar vertebra 3 (L-3) were determined in axial compression on functional three-segment units. In situ anteroposterior DXA and QCT of the lumbar spine explained approximately 65% of the variability of thoracolumbar failure. A combination of cortical and trabecular density (QCT) provided the best prediction in the lumbar spine. However, this was not the case in the thoracic spine, for which lumbar cortical density (QCT) and DXA provided significantly better estimates than trabecular density (QCT). pQCT was significantly less correlated with the strength of lumbar and thoracic vertebrae (r(2) = 40%), but was equivalent to femoral or radial DXA. pQCT measurements in the lower limb showed no advantage over those at the distal radius. Ultrasound explained approximately 25% of the variability of vertebral failure strength and added independent information to spinal QCT, but not to spinal DXA. These experimental results advocate site-specific assessment of vertebral strength by either spinal DXA or QCT.


Asunto(s)
Pierna/diagnóstico por imagen , Vértebras Lumbares/diagnóstico por imagen , Vértebras Torácicas/diagnóstico por imagen , Absorciometría de Fotón/métodos , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Femenino , Predicción , Humanos , Masculino , Persona de Mediana Edad , Análisis de Regresión , Estrés Mecánico , Tomografía Computarizada por Rayos X/métodos , Ultrasonografía
13.
Bone ; 30(1): 207-16, 2002 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-11792587

RESUMEN

This experimental study compares geometric and densitometric properties of cortical and trabecular bone at the lower limb and the distal radius with those at the femoral neck, and evaluates their ability to predict mechanical failure loads of the proximal femur. One hundred five cadavers were examined with peripheral quantitative computed tomography (LpQCT), with measurements being performed in situ at the distal radius (4%, 20%, 33%), at the distal and proximal tibia, at the tibial and femoral shaft, and at the distal femur. Ex situ measurements were obtained at the femoral neck and at the proximal femoral shaft. Pairs of femora were mechanically tested in a vertical loading and a side impact (fall) configuration. The total (cross-sectional) bone mineral content and trabecular density, but not the cortical properties, displayed a higher association between the femoral neck and the peripheral lower limb than between the neck and the distal radius. Approximately 50%-60% of the variability of femoral failure loads (and >80% of trochanteric side impact fractures) were predicted by in vitro measurements at the neck. Geometric cortical parameters and density contributed independently and significantly to femoral strength. Measurements at the peripheral skeleton explained, however, only 30%-45% of the variability of femoral failure, with no significant difference between the lower limb and the distal radius. At peripheral sites, a combination of geometric and densitometric variables was slightly superior to bone mineral content alone in predicting failure in vertical loading, but this was less evident for cervical side impact fractures. The results show that a stronger association of total bone mineral content and trabecular density between the femoral neck and the lower limb does not translate into improved prediction of femoral strength from measurements at the lower limb vs. those at the distal radius.


Asunto(s)
Densidad Ósea/fisiología , Cuello Femoral/fisiología , Radio (Anatomía)/fisiología , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Femenino , Cuello Femoral/diagnóstico por imagen , Humanos , Técnicas In Vitro , Masculino , Persona de Mediana Edad , Radio (Anatomía)/diagnóstico por imagen , Estrés Mecánico , Tomografía Computarizada por Rayos X
14.
J Biomech ; 34(5): 579-87, 2001 May.
Artículo en Inglés | MEDLINE | ID: mdl-11311698

RESUMEN

In this study we explore the hypothesis that estimates of failure loads in the thoracic spine by lumbar dual energy X-ray absorptiometry (DXA) are compromised of skeletal heterogeneity throughout the spine and artifacts of spinal DXA. We studied the correlation between mechanical failure loads of thoracic and lumbar vertebrae, and that of in situ vs. ex situ lumbar DXA with thoracic and lumbar fracture loads, respectively. One hundred and nineteen subjects (76 female, age 82+/-9yr; 43 male, age 77+/-11yr) were examined under in situ conditions (anterior-posterior direction), the scans being repeated ex situ (lateral projection) in 68 cases. The failure loads of thoracic vertebrae (T) 6 and 10, and lumbar vertebra (L) 3 were determined in axial compression, using a functional 3-segment unit. The correlation between thoracic failure loads (T6 vs. T10) was significantly (p<0.01) higher (r=0.85) than those between thoracic and lumbar vertebrae (r=0.68 and 0.61, respectively). Lateral ex situ DXA displayed a significantly higher correlation (p<0.05) with lumbar vertebral fracture loads than in situ anterior-posterior DXA (r=0.85 vs. 0.71), but the correlation of thoracic failure loads with lateral ex situ lumbar DXA was similar to that obtained in situ in anterior-posterior direction (r=0.69 vs. 0.69 for T10, and r=0.61 vs. 0.65 for T6). The correlation between fracture loads of different spinal segments, and between DXA and failure loads was not significantly different between men and women. The results demonstrate a substantial heterogeneity of mechanical competence throughout the spine in elderly individuals. Because of the high incidence of fractures in the thoracic spine, these findings suggest that, clinically, lateral DXA involves no relevant advantage over anterior-posterior measurements of the lumbar spine.


Asunto(s)
Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/fisiología , Vértebras Torácicas/diagnóstico por imagen , Vértebras Torácicas/fisiología , Absorciometría de Fotón , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Densidad Ósea , Fuerza Compresiva , Femenino , Humanos , Técnicas In Vitro , Masculino
15.
Comput Methods Programs Biomed ; 52(3): 175-83, 1997 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-9051341

RESUMEN

The software system KAMEDIN (Kooperatives Arbeiten und MEdizinische Diagnostik auf Innovativen Netzen) is a multimedia telemedicine system for exchange, cooperative diagnostics, and remote analysis of digital medical image data. It provides components for visualisation, processing, and synchronised audio-visual discussion of medical images. Techniques of computer supported cooperative work (CSCW) synchronise user interactions during a teleconference. Visibility of both local and remote cursor on the conference workstations facilitates telepointing and reinforces the conference partner's telepresence. Audio communication during teleconferences is supported by an integrated audio component. Furthermore, brain tissue segmentation with artificial neural networks can be performed on an external supercomputer as a remote image analysis procedure. KAMEDIN is designed as a low cost CSCW tool for ISDN based telecommunication. However it can be used on any TCP/IP supporting network. In a field test, KAMEDIN was installed in 15 clinics and medical departments to validate the systems' usability. The telemedicine system KAMEDIN has been developed, tested, and evaluated within a research project sponsored by German Telekom.


Asunto(s)
Intensificación de Imagen Radiográfica , Telerradiología , Humanos , Programas Informáticos
16.
J Telemed Telecare ; 3(2): 103-7, 1997.
Artículo en Inglés | MEDLINE | ID: mdl-9206281

RESUMEN

The KAMEDIN system was designed as a low-cost communication tool as part of a computer-supported cooperative work project that included synchronized user interaction, telepointing and audioconferencing. During a five-month field trial, it was used for medical image transfer and cooperative diagnosis in 14 clinics and medical departments in Germany. During the field test, 297 teleconsultations were performed via ISDN and 875 MByte of data were transferred. An image compression ratio of 2-3 was obtained, so that the total quantity of data transferred corresponded to 14,000-21,000 magnetic resonance images or 3500-5250 computerized tomography images. Furthermore, 694 local sessions were conducted for the preparation of teleconsultations and the review of transferred images. Participants learned to handle the KAMEDIN system in a few hours. This was mainly owing to the design of the user-oriented graphical user interface and the restriction of the system to a set of essential image-processing functions.


Asunto(s)
Programas Informáticos , Telemedicina/métodos , Telemetría/métodos , Computadores , Humanos , Telemedicina/instrumentación
18.
Medinfo ; 8 Pt 2: 1511-4, 1995.
Artículo en Inglés | MEDLINE | ID: mdl-8591486

RESUMEN

This contribution describes the software system KAMEDIN (Kooperatives Arbeiten und MEdizinische Diagnostik auf Innovativen Netzen) that is designed as an ISDN based computer supported cooperative work (CSCW) tool for usage in medical diagnostics. Medical image data from various sources (for example CT and MR) can be interchanged and analyzed in bilateral teleconferences via ISDN. During a cooperative session, user interactions for image processing etc., are synchronized and performed on both workstations, Features like telepointing, remote control, and audio connection enhance communication quality. With ISDN as a transmission line, widespread availability and low communication costs are achieved. Further, automatic tissue labeling in intracranial MR data can be invoked. For this purpose, artificial neural network classifiers such as multilayer perceptron and Kohenen feature map are integrated. Classification results can be viewed as 3D-reconstructions.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Programas Informáticos , Telerradiología , Encefalopatías/diagnóstico , Sistemas de Computación , Sistemas Especialistas , Alemania , Humanos , Interpretación de Imagen Asistida por Computador , Servicios de Información , Imagen por Resonancia Magnética , Redes Neurales de la Computación , Interfaz Usuario-Computador
19.
Pharm Res ; 9(10): 1336-40, 1992 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-1448435

RESUMEN

In binary Macrogolstearate 400 (MS 400)/water systems, lamellar surfactant arrangements can be detected by polarized light and transmission electron microscopy. As demonstrated by X-ray diffraction and differential scanning calorimetry, the alkyl chains of the emulsifier are in the crystalline state. Ternary systems with liquid paraffin represent optically isotropic, homogeneous o/w creams for a wide composition range. Incorporation of up to 50 mol% cholesterol into the MS 400 lamellar structures leads to a gel-liquid crystalline phase separation within the bilayer, thus enabling the formation of spherical nonionic vesicles. The transition enthalpy of the samples decreases linearly with increasing cholesterol concentrations. The Macrogolstearate 400/cholesterol vesicles proved to be stable in hydrophilic cream systems. Cationic vesicles can be prepared using cetyltrimethylammonium bromide (CTAB) as a charge inducer. Low-CTAB portions are inhomogeneously distributed within the bilayer, as detected by DSC. The results also indicate a perturbation of the alkyl chains packing for the positively charged vesicles.


Asunto(s)
Excipientes , Pomadas , Polietilenglicoles/química , Tensoactivos/química , Rastreo Diferencial de Calorimetría , Cetrimonio , Compuestos de Cetrimonio , Fenómenos Químicos , Química Física , Colesterol/química , Membranas Artificiales , Microscopía Electrónica de Rastreo , Difracción de Rayos X
20.
Berl Munch Tierarztl Wochenschr ; 105(3): 81-5, 1992 Mar 01.
Artículo en Alemán | MEDLINE | ID: mdl-1575670

RESUMEN

17 beta-Estradiol (E2) and progesterone were tested in vitro for their ability to act as anti-glucocorticoids in thymus and spleen cell cultures of ovariectomized female Lewis rats. Initially, the immunosuppressive effect of corticosterone was verified and both sex steroids were also found to inhibit mitogenic, antigenic and allogeneic lymphoblast transformation although at concentrations higher than those for corticosterone. The suppressive activities were stronger in thymocyte than splenocyte cultures. On the other side, E2 significantly enhanced lymphoblast transformation at concentrations of 10(-9) to 10(-7) mol per litre while progesterone had only moderately increasing effects. Combination of corticosterone with progesterone or both sex steroids resulted in significantly elevated 3Tdr incorporation of mitogen-stimulated thymocytes compared to cultures incubated with corticosterone alone while in splenocyte cultures only the mixed lymphocyte reaction showed similar effects. No synergy between E2 and progesterone in counteracting corticosterone-induced inhibition of lymphocyte proliferation has been observed. In conclusion, corticosterone, E2 and progesterone showed a dose-dependent influence on lymphoblast transformation of thymocytes and splenocytes and progesterone had opposite effects on corticosterone-induced suppression of blastogenesis in rat lymphocytes, especially in thymocytes.


Asunto(s)
Corticosterona/farmacología , Estradiol/farmacología , Activación de Linfocitos/efectos de los fármacos , Progesterona/farmacología , Animales , Células Cultivadas , Femenino , Ratas , Ratas Endogámicas Lew , Bazo/citología , Bazo/efectos de los fármacos , Timo/citología , Timo/efectos de los fármacos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...