Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
1.
Geriatr Orthop Surg Rehabil ; 15: 21514593241293645, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39444567

RESUMEN

Introduction: Hip fracture is particularly seen in elderly patients with frailty and osteoporosis and leads to diminished functional independence and quality of life. Despite the susceptibility of these patients to a second hip fracture (SHF), the literature insufficiently discussed its impact leading to poor outcomes. This study aims to directly assess the outcomes of elderly patients with initial hip fractures (IHF) vs those experiencing an SHF within a well-matched group with similar characteristics. Materials and Methods: This case-control study gathered data from the clinical hip fracture registry at a medical center from 2019 to 2022. Patients with SHF were matched with those with IHF in a 1:2 ratio according to the similarity of age, sex, and Charlson Comorbidity Index classification. Demographics at admission, baseline characteristics, and 1-year postoperative outcome were compared between the SHF and IHF groups. Results: Thirty-two SHF patients were matched with 64 IHF patients (81.25% of women, median age of 86 years). Anthropometric measurements and socioeconomic factors were not significantly different between the two groups. No differences in baseline characteristics were observed, except IHF patients had a significantly lower T-score than SHF patients (-3.98 vs. -3.31, P = 0.016). At one-year follow-up, despite a notable decrease in Barthel Index scores and an uptick in EQ-5D measures among the patients, the IHF and SHF groups demonstrated similar quality of life and a high level of activities of daily living. Discussions: In this case-control study, after matching for age, sex, and comorbidities, an SHF did not indicate poorer outcomes than an IHF, providing a more optimistic outlook for the patients and healthcare providers. Conclusion: Despite the significant challenges presented by hip fracture, the one-year postoperative outcomes did not differ between IHF and SHF patients, suggesting that SHF is not an independent predictor of poor outcomes following hip fracture in the elderly population.

2.
World Neurosurg ; 2024 Sep 11.
Artículo en Inglés | MEDLINE | ID: mdl-39270783

RESUMEN

BACKGROUND: Polyetheretherketone (PEEK) cages and structural allografts (SAs) are commonly used in anterior cervical discectomy and fusion (ACDF), yet their postoperative results remain uncertain. This meta-analysis was conducted to determine whether there were any differences in outcomes between patients who received these two grafts in ACDF. METHODS: We comprehensively searched electronic databases up to August 2023. Observational studies or randomized controlled trials reported postoperative outcomes, including fusion, subsidence, reoperation rates, and patient-reported outcomes through the Neck Disability Index, the visual analog scale for neck and arm pain, and the Japanese Orthopaedic Association (JOA)/modified JOA score following primary ACDF using SA or PEEK cage. The results are presented in odds ratios (ORs) or mean differences with corresponding 95% confidence intervals (CIs). RESULTS: Eleven studies were included, with 1213 patients (788 receiving SAs and 425 receiving PEEK cages). Patients having SA had significantly higher fusion (OR: 1.84; 95% CI: 1.27-2.67; P = 0.001) and lower subsidence (OR: 0.50; 95% CI: 0.30-0.86; P = 0.01) rates when compared with the PEEK cage. There was no difference in revision rate between SA or PEEK cage (P = 0.88). Two grafts demonstrated similar clinical improvements in Neck Disability Index (P = 0.31), visual analog scale for the neck (P = 0.77) and arm pain (P = 0.22), and JOA/modified JOA score (P = 0.99). CONCLUSIONS: SA demonstrates better fusion and lower subsidence rates than the PEEK cage in ACDF. Nevertheless, SAs and PEEK cages resulted in equally successful postoperative clinical performances.

3.
EFORT Open Rev ; 9(8): 817-826, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39087505

RESUMEN

Purpose: Studies have reported conflicting findings on the relationship between smoking and surgical site infection (SSI) post fixation for ankle and calcaneal fractures. This meta-analysis explored the effect of smoking on SSI incidence following open reduction and internal fixation (ORIF) of these fractures. Methods: Full-text studies on smoking's influence on post-ORIF SSI rates for closed ankle and calcaneal fractures were sourced from the PubMed, Embase, and Cochrane databases, with no consideration given to language or publication date. Study quality was appraised using the Newcastle-Ottawa Scale. Odds ratios (OR) and the corresponding 95% CIs were determined using random-effects models. This meta-analysis adhered to the PRISMA guidelines and was registered with PROSPERO (CRD42023429372). Results: The analysis incorporated data from 16 cohort and case-control studies, totaling 41 944 subjects, 9984 of whom were smokers, with 956 SSI cases. Results indicated smokers faced a higher SSI risk (OR: 1.62; 95% CI: 1.32-1.97, P < 0.0001) post ORIF, with low heterogeneity (I 2 = 26%). Smoking was identified as a significant deep SSI risk factor (OR: 2.09; 95% CI: 1.42-3.09; P = 0.0002; I 2 = 31%). However, the subgroup analysis revealed no association between smoking and superficial SSI (OR: 1.05; 95% CI: 0.82-1.33; P = 0.70; I 2 = 0%). Conclusion: Smoking is associated with increased SSI risk after ORIF for closed ankle and calcaneus fractures. Although no clear link was found between superficial SSI and smoking, the data underscore the negative influence of smoking on deep SSI incidence.

4.
Foot Ankle Surg ; 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38987122

RESUMEN

BACKGROUND: Smoking has long been recognized as a risk factor for impaired wound and bone healing, particularly in the context of ankle and foot surgery. Despite numerous studies exploring the association between smoking and complications following ankle replacement, there remains significant inconsistency in their findings. Therefore, this meta-analysis study aims to elucidate whether smoking increases the rate of complications after total ankle arthroplasty (TAA), providing valuable insights for clinical management. METHODS: A comprehensive systematic search was conducted in the PubMed, Embase, and Wiley databases to identify relevant English studies on the influence of smoking on postoperative complications following ankle replacement without any restrictions on publication dates. The quality of the included studies was assessed using the Newcastle-Ottawa Scale. Random-effect models were used to calculate odds ratios (OR) and 95 % confidence intervals (CI). This study adhered to PRISMA guidelines for transparent reporting and was registered with PROSPERO. RESULTS: The analysis incorporated data from 12 retrospective cohort studies, totaling 17331 subjects, 2580 of whom were smokers and 791 complications following TAA. The findings revealed a statistically significant disparity in wound-related complications (OR: 2.26; 95 % CI: 1.13-4.50; P = .02), particularly evident in current smokers with an OR of 3.30 (95 % CI: 2.12-5.14; P < .00001). However, we lacked sufficient evidence to substantiate an association between smoking and complications related to the prosthesis (OR: 1.09; 95 % CI: 0.77-1.53; P = .64) or systemic complications (OR: 1.18; 95 % CI: 0.10-14.13; P = .90) following TAA. CONCLUSIONS: Smoking, especially current smoking, is associated with increased wound complication risk post-operation for total ankle arthroplasty. Despite a lack of definitive evidence on the optimal timeframe for smoking cessation before surgery, discontinuing smoking appears to be a prudent measure to mitigate these complications.

5.
BMC Musculoskelet Disord ; 25(1): 559, 2024 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-39026178

RESUMEN

BACKGROUND: The inclusion of a connecting path in a porous implant can promote nutrient diffusion to cells and enhance bone ingrowth. Consequently, this study aimed to evaluate the biomechanical, radiographic, and histopathological performance of a novel 3D-printed porous suture anchor in a rabbit femur model. METHODS: Three test groups were formed based on the type of suture anchor (SA): Commercial SA (CSA, Group A, n = 20), custom solid SA (CSSA, Group B, n = 20), and custom porous SA (CPSA, Group C, n = 20). The SAs were implanted in the lateral femoral condyle of the right leg in each rabbit. The rabbits (New Zealand white rabbits, male, mean body weight of 2.8 ± 0.5 kg, age 8 months) underwent identical treatment and were randomized into experimental and control groups via computer-generated randomization. Five rabbits (10 femoral condyles) were euthanized at 0, 4, 8, and 12 weeks post-implantation for micro-CT, histological analysis, and biomechanical testing. RESULTS: At 12 weeks, the CPSA showed a higher BV/TV (median 0.7301, IQR 0.7276-0.7315) than the CSSA and CSA. The histological analysis showed mineralized osteocytes near the SA. At 4 weeks, new bone was observed around the CPSA and had penetrated its porous structure. By 12 weeks, there was no significant difference in ultimate failure load between the CSA and CPSA. CONCLUSIONS: We demonstrated that the innovative 3D-printed porous suture anchor exhibited comparable pullout strength to conventional threaded suture anchors at the 12-week postoperative time-point period. Furthermore, our porous anchor design enhanced new bone formation and facilitated bone growth into the implant structure, resulting in improved biomechanical stability.


Asunto(s)
Fémur , Impresión Tridimensional , Anclas para Sutura , Titanio , Animales , Conejos , Fémur/cirugía , Fémur/diagnóstico por imagen , Fémur/patología , Porosidad , Masculino , Fenómenos Biomecánicos , Microtomografía por Rayos X
6.
J Mater Chem B ; 12(32): 7814-7825, 2024 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-38895823

RESUMEN

In recent decades, orthopedic implants have been widely used as materials to replace human bone tissue functions. Among these, metal implants play a crucial role. Metals with better chemical stability, such as stainless steel, titanium alloys, and cobalt-chromium-molybdenum (CoCrMo) alloy, are commonly used for long-term applications. However, good chemical stability can result in poor tissue integration between the tissue and the implant, leading to potential inflammation risks. This study creates hydrogenated CoCrMo (H-CoCrMo) surfaces, which have shown promise as anti-inflammatory orthopedic implants. Using the electrochemical cathodic hydrogen-charging method, the surface of the CoCrMo alloy was hydrogenated, resulting in improved biocompatibility, reduced free radicals, and an anti-inflammatory response. Hydrogen diffusion to a depth of approximately 106 ± 27 nm on the surface facilitated these effects. This hydrogen-rich surface demonstrated a reduction of 85.2% in free radicals, enhanced hydrophilicity as evidenced by a decrease in a contact angle from 83.5 ± 1.9° to 52.4 ± 2.2°, and an increase of 11.4% in hydroxyapatite deposition surface coverage. The cell study results revealed a suppression of osteosarcoma cell activity to 50.8 ± 2.9%. Finally, the in vivo test suggested the promotion of new bone formation and a reduced inflammatory response. These findings suggest that electrochemical hydrogen charging can effectively modify CoCrMo surfaces, offering a potential solution for improving orthopedic implant outcomes through anti-inflammatory mechanisms.


Asunto(s)
Materiales Biocompatibles , Hidrógeno , Inflamación , Vitalio , Inflamación/tratamiento farmacológico , Inflamación/inducido químicamente , Humanos , Hidrógeno/química , Vitalio/química , Vitalio/farmacología , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología , Propiedades de Superficie , Prótesis e Implantes , Animales , Aleaciones/química , Aleaciones/farmacología , Cobalto/química , Ensayo de Materiales , Ratones , Tamaño de la Partícula
8.
J Orthop Surg Res ; 19(1): 270, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38689328

RESUMEN

BACKGROUND: Rotator cuff tears (RCTs) are a common musculoskeletal disorder, and arthroscopic rotator cuff repair (ARCR) is widely performed for tendon repair. Handgrip strength correlates with rotator cuff function; however, whether preoperative grip strength can predict functional outcomes in patients undergoing ARCR remains unknown. This study aimed to investigate the correlation between preoperative grip strength and postoperative shoulder function following ARCR. METHODS: A total of 52 patients with full-thickness repairable RCTs were prospectively enrolled. Baseline parameters, namely patient characteristics and intraoperative findings, were included for analysis. Postoperative shoulder functional outcomes were assessed using the Quick Disabilities of the Arm, Shoulder, and Hand (QDASH) questionnaire and Constant-Murley scores (CMSs). Patients were followed up and evaluated at three and six months after ARCR. The effects of baseline parameters on postoperative outcomes were measured using generalized estimating equations. RESULTS: At three and six months postoperatively, all clinical outcomes evaluated exhibited significant improvement from baseline following ARCR. Within 6 months postoperatively, higher preoperative grip strength was significantly correlated with higher CMSs (ß = 0.470, p = 0.022), whereas increased numbers of total suture anchors were significantly correlated with decreased CMSs (ß = - 4.361, p = 0.03). Higher body mass index was significantly correlated with higher postoperative QDASH scores (ß = 1.561, p = 0.03) during follow-up. CONCLUSIONS: Higher baseline grip strength predicts more favorable postoperative shoulder function following ARCR. A preoperative grip strength test in orthopedic clinics may serve as a predictor for postoperative shoulder functional recovery in patients undergoing ARCR.


Asunto(s)
Artroscopía , Fuerza de la Mano , Lesiones del Manguito de los Rotadores , Humanos , Masculino , Femenino , Persona de Mediana Edad , Artroscopía/métodos , Fuerza de la Mano/fisiología , Lesiones del Manguito de los Rotadores/cirugía , Lesiones del Manguito de los Rotadores/fisiopatología , Anciano , Estudios Prospectivos , Periodo Preoperatorio , Periodo Posoperatorio , Resultado del Tratamiento , Valor Predictivo de las Pruebas , Recuperación de la Función/fisiología , Manguito de los Rotadores/cirugía , Manguito de los Rotadores/fisiopatología , Estudios de Seguimiento , Adulto , Hombro/cirugía , Hombro/fisiopatología
9.
Ther Adv Musculoskelet Dis ; 16: 1759720X241237872, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38665415

RESUMEN

Background: Despite being the gold standard for diagnosing osteoporosis, dual-energy X-ray absorptiometry (DXA) is an underutilized screening tool for osteoporosis. Objectives: This study proposed and validated a controllable feature layer of a convolutional neural network (CNN) model with a preprocessing image algorithm to classify osteoporosis and predict T-score on the proximal hip region via simple hip radiographs. Design: This was a single-center, retrospective study. Methods: An image dataset of 3460 unilateral hip images from 1730 patients (age ⩾50 years) was retrospectively collected with matched DXA assessment for T-score for the targeted proximal hip regions to train (2473 unilateral hip images from 1430 patients) and test (497 unilateral hip images from 300 patients) the proposed CNN model. All images were processed with a fully automated CNN model, X1AI-Osteo. Results: The proposed screening tool illustrated a better performance (sensitivity: 97.2%; specificity: 95.6%; positive predictive value: 95.7%; negative predictive value: 97.1%; area under the curve: 0.96) than the open-sourced CNN models in predicting osteoporosis. Moreover, when combining variables, including age, body mass index, and sex as features in the training metric, there was high consistency in the T-score on the targeted hip regions between the proposed CNN model and the DXA (r = 0.996, p < 0.001). Conclusion: The proposed CNN model may identify osteoporosis and predict T-scores on the targeted hip regions from simple hip radiographs with high accuracy, highlighting the future application for population-based opportunistic osteoporosis screening with low cost and high adaptability for a broader population at risk. Trial registration: TMU-JIRB N201909036.

10.
Medicina (Kaunas) ; 60(3)2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38541211

RESUMEN

Background and Objectives: Hip fractures in the elderly pose a considerable health risk and cause concern. Red blood cell distribution width (RDW) is a valuable marker for identifying patients at high risk of age-related mortality and various disorders and diseases. However, its association with poor patient outcomes following hip fractures has yet to be fully established. Hence, the purpose of this meta-analysis was to investigate and gain a better understanding of the relationship between RDW levels and the risk of mortality after hip fractures. Materials and Methods: PubMed, Embase, Web of Science, and other databases were comprehensively searched until April 2023 to identify relevant studies. The meta-analysis included observational studies finding the association between RDW at admission or preoperation and short-term and long-term mortality rates following hip fractures. The results were presented in terms of odds ratios (ORs) or hazard ratios (HRs) with corresponding 95% confidence intervals (CIs). Results: This meta-analysis included 10 studies involving 5834 patients with hip fractures. Patients with preoperative RDW of over 14.5% had higher risks of 1-year (OR: 5.40, 95% CI: 1.89-15.48, p = 0.002) and 3-month (OR: 2.91, 95% CI: 1.42-5.95, p = 0.004) mortality. Higher admission or preoperative RDW was significantly associated with an 11% higher mortality risk after 1 year (HR: 1.11, 95% CI: 1.06-1.17, p < 0.00001). Patients with higher preoperative RDW had a significantly higher risk of 6-month mortality, which was three times that of those with lower preoperative RDW (OR: 3.00, 95% CI: 1.60-5.61, p = 0.0006). Higher preoperative RDW was correlated to a higher 30-day mortality risk (OR: 6.44, 95% CI: 3.32-12.47, p < 0.00001). Conclusions: Greater RDW values at admission or before surgery were associated with a higher risk of short-term and long-term mortality following hip fractures. Because RDW can be easily measured using a routine blood test at a low cost, this parameter is promising as an indicator of mortality in elderly patients with hip fractures.


Asunto(s)
Fracturas de Cadera , Humanos , Anciano , Hospitalización , Índices de Eritrocitos , Eritrocitos , Pronóstico
11.
JMIR Public Health Surveill ; 10: e46591, 2024 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-38342504

RESUMEN

BACKGROUND: To enhance postoperative patient survival, particularly in older adults, understanding the predictors of mortality following hip fracture becomes paramount. Air pollution, a prominent global environmental issue, has been linked to heightened morbidity and mortality across a spectrum of diseases. Nevertheless, the precise impact of air pollution on hip fracture outcomes remains elusive. OBJECTIVE: This retrospective study aims to comprehensively investigate the profound influence of a decade-long exposure to 12 diverse air pollutants on the risk of post-hip fracture mortality among older Taiwanese patients (older than 60 years). We hypothesized that enduring long-term exposure to air pollution would significantly elevate the 1-year mortality rate following hip fracture surgery. METHODS: From Taiwan's National Health Insurance Research Database, we obtained the data of patients who underwent hip fracture surgery between July 1, 2003, and December 31, 2013. Using patients' insurance registration data, we estimated their cumulative exposure levels to sulfur dioxide (SO2), carbon dioxide (CO2), carbon monoxide (CO), ozone (O3), particulate matter having a size of <10 µm (PM10), particulate matter having a size of <2.5 µm (PM2.5), nitrogen oxides (NOX), nitrogen monoxide (NO), nitrogen dioxide (NO2), total hydrocarbons (THC), nonmethane hydrocarbons (NMHC), and methane (CH4). We quantified the dose-response relationship between these air pollutants and the risk of mortality by calculating hazard ratios associated with a 1 SD increase in exposure levels over a decade. RESULTS: Long-term exposure to SO2, CO, PM10, PM2.5, NOX, NO, NO2, THC, NMHC, and CH4 demonstrated significant associations with heightened all-cause mortality risk within 1 year post hip fracture surgery among older adults. For older adults, each 1 SD increment in the average exposure levels of SO2, CO, PM10, PM2.5, NOX, NO, NO2, THC, NMHC, and CH4 corresponded to a substantial escalation in mortality risk, with increments of 14%, 49%, 18%, 12%, 41%, 33%, 38%, 20%, 9%, and 26%, respectively. We further noted a 35% reduction in the hazard ratio for O3 exposure suggesting a potential protective effect, along with a trend of potentially protective effects of CO2. CONCLUSIONS: This comprehensive nationwide retrospective study, grounded in a population-based approach, demonstrated that long-term exposure to specific air pollutants significantly increased the risk of all-cause mortality within 1 year after hip fracture surgery in older Taiwanese adults. A reduction in the levels of SO2, CO, PM10, PM2.5, NOX, NO, NO2, THC, NMHC, and CH4 may reduce the risk of mortality after hip fracture surgery. This study provides robust evidence and highlights the substantial impact of air pollution on the outcomes of hip fractures.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire , Fracturas de Cadera , Humanos , Anciano , Estudios de Cohortes , Dióxido de Nitrógeno/análisis , Estudios Retrospectivos , Taiwán/epidemiología , Dióxido de Carbono , Contaminación del Aire/efectos adversos , Contaminación del Aire/análisis , Contaminantes Atmosféricos/efectos adversos , Contaminantes Atmosféricos/análisis , Material Particulado/efectos adversos , Material Particulado/análisis , Fracturas de Cadera/cirugía , Fracturas de Cadera/inducido químicamente , Óxido Nítrico , Hidrocarburos
12.
BMC Musculoskelet Disord ; 24(1): 863, 2023 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-37932751

RESUMEN

BACKGROUND: Surgeons are routinely required to remove loose or failed pedicle screws and insert a new screw in their place. However, inserting a new screw into an existing hole may compromise the holding capacity of the pedicle screw. The purpose of this study is to evaluate the pullout strength of pedicle screws with different thread designs after the primary insertion and revision surgery in a synthetic bone model. METHODS: Four pedicle screws with different thread designs (single-lead-thread (SLT) screw, dual-lead-thread (DLT) screw, mixed-single-lead-thread (MSLT) screw, and proximal-unthreaded-dual-thread (PUDL) screw) were inserted into pre-drilled, untapped holes (ø 4.2 mm, length 35 mm) in Sawbone blocks of density 20 pcf. In the first sequence, a 6.0 mm screw was inserted into the predrilled foam block and the primary pullout strength of the screw was measured according to ASTM F543. In the second sequence, a 6.0 mm screw was inserted and removed, and then either a 6.5 mm screw of the same design or a different screw design was inserted into the same hole and the pullout strength recorded. RESULTS: In the first sequence, the mean pullout strength of the MSLT screw was significantly (p < 0.05) greater than all other screw designs. In the second sequence, when the MSLT screw was the primary screw, using a larger MSLT screw (6.5 mm) as the revision screw did not lead to a higher pullout strength than if a 6.0 mm diameter PUDL screw was used for the revision. Using a larger DLT screw (6.5 mm) as the revision screw resulted in a significantly (p < 0.05) greater pullout strength than a 6.0 mm STL, DLT, MSLT, or PUDL screw. CONCLUSIONS: Our results indicate that employing classic oversizing of the same screw design is a safe choice for maintaining screw purchase in the bone after revision. In cases where oversizing with the same screw design is not practical, opting for a PUDL screw with the same original diameter can provide enough purchase in the bone to maintain stability.


Asunto(s)
Tornillos Pediculares , Humanos , Ensayo de Materiales , Poliuretanos , Huesos , Fenómenos Biomecánicos
13.
J Orthop Surg Res ; 18(1): 791, 2023 Oct 24.
Artículo en Inglés | MEDLINE | ID: mdl-37872535

RESUMEN

BACKGROUND: Hip fracture can lead to long-term loss of mobility and self-care ability in older adults. Despite initial decreases in functional performance after hip fracture surgery, patients tend to gradually recover. However, recovery can vary, with some regaining their abilities quickly while others becoming functionally dependent. In this study, we investigated whether the level of short-term postoperative decline in activity of daily living (ADL) performance and quality of life (QoL) can predict the 1-year outcomes for both following hip fracture surgery in older Taiwanese adults. METHODS: This prospective cohort study included 427 older adults (≥ 60 years) who underwent hip fracture surgery at a single tertiary medical center in Taiwan between November 2017 and March 2021. We collected pre-fracture data, including the patients' demographics, Charlson comorbidity index (CCI) scores, and responses to a questionnaire (Short Portable Mental State Questionnaire [SPMSQ]) for dementia screening. Moreover, their scores on the EuroQol-5D questionnaire (for evaluating QoL) and the Barthel Index (for assessing ADL performance) were collected at pre-fracture status and at 3- and 12-months following surgery. Changes in ADL and QoL three months post-surgery compared to pre-fracture status were evaluated, and the associations of these parameters (and other potential factors) with 1-year outcomes for ADL and QoL were investigated. RESULTS: We analyzed the data of 318 patients with hip fracture and complete follow-up data regarding ADL performance and QoL at 3- and 12-months post-surgery. After adjusting for covariates, multivariate linear regression revealed that changes in ADL and QoL at 3 months post-surgery from pre-fracture status were positively and significantly associated with 1-year outcomes for both (p < .001 for both). Furthermore, pre-fracture CCI and SPMSQ scores were independent predictive factors associated with 1-year ADL outcomes (p = .042 and < .001, respectively). CONCLUSIONS: Patients who exhibit a smaller decline in functional performance and quality of life three months after hip fracture surgery from pre-fracture status are likely to have improved long-term ADL and QoL. TRIAL REGISTRATION: TMU-JIRB N201709053.


Asunto(s)
Fracturas de Cadera , Calidad de Vida , Humanos , Anciano , Estudios Prospectivos , Fracturas de Cadera/complicaciones , Actividades Cotidianas , Rendimiento Físico Funcional
14.
Ther Adv Musculoskelet Dis ; 15: 1759720X231177147, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37359176

RESUMEN

Background: T-score discordance is common in osteoporosis diagnosis and leads to problems for clinicians formulating treatment plans. Objectives: This study investigated the potential predictors of T-score discordance and compared fracture risk among individuals with varying T-score discordance status. Design: This was a single-center cross-sectional study conducted at Wan Fang Hospital, Taipei City, between 1 February 2020 and 31 January 2022. Methods: The present study enrolled patients aged ⩾50 years who received advanced bone health examination. Participants with a history of fracture surgery or underlying musculoskeletal diseases were excluded. Bioelectrical impedance analysis and dual-energy X-ray absorptiometry were used to determine the body composition and T-score, respectively. Discordance was defined as different T-score categories between the lumbar spine and hip. The impact of discordance on an individual's fracture risk was assessed using the Fracture Risk Assessment Tool (FRAX). Results: This study enrolled 1402 participants (181 men and 1221 women). Of the 912 participants diagnosed with osteoporosis, 47 (5%) and 364 (40%) were categorized as having major and minor discordance, respectively. Multinomial logistic regression revealed that decreased walking speed was significantly correlated with major discordance but not osteoporosis in both the hip and lumbar spine (odds ratio of 0.25, p = 0.04). The adjusted FRAX scores for the major osteoporotic fracture risks of the major and minor discordance groups were approximately 14%, which was significantly lower than that of people having osteoporosis in both the hip and lumbar spine. Conclusions: Walking speed exhibited the most significant correlation with major discordance in patients with osteoporosis. Although adjusted major fracture risks were similar between the major and minor discordance groups, further longitudinal studies are warranted to confirm this finding. Registrations: This study was approved by the Ethics Committee of Taipei Medical University on 01/04/2022 (TMU-JIRB N202203088).

15.
Medicina (Kaunas) ; 59(6)2023 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-37374383

RESUMEN

Background and Objectives: Osteoporosis is characterized by low bone mass and high bone fragility. Findings regarding the association of coffee and tea intake with osteoporosis have been inconsistent. We conducted this meta-analysis to investigate whether coffee and tea intake is associated with low bone mineral density (BMD) and high hip fracture risk. Materials and Methods: PubMed, MEDLINE, and Embase were searched for relevant studies published before 2022. Studies on the effects of coffee/tea intake on hip fracture/BMD were included in our meta-analysis, whereas those focusing on specific disease groups and those with no relevant coffee/tea intake data were excluded. We assessed mean difference (MD; for BMD) and pooled hazard ratio (HR; for hip fracture) values with 95% confidence interval (CI) values. The cohort was divided into high- and low-intake groups considering the thresholds of 1 and 2 cups/day for tea and coffee, respectively. Results: Our meta-analysis included 20 studies comprising 508,312 individuals. The pooled MD was 0.020 for coffee (95% CI, -0.003 to 0.044) and 0.039 for tea (95% CI, -0.012 to 0.09), whereas the pooled HR was 1.008 for coffee (95% CI, 0.760 to 1.337) and 0.93 for tea (95% CI, 0.84 to 1.03). Conclusions: Our meta-analysis results suggest that daily coffee or tea consumption is not associated with BMD or hip fracture risk.


Asunto(s)
Fracturas de Cadera , Osteoporosis , Humanos , Densidad Ósea , Café/efectos adversos , Té/efectos adversos , Factores de Riesgo
16.
Bioengineering (Basel) ; 10(6)2023 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-37370591

RESUMEN

Pullout strength is an important indicator of the performance and longevity of pedicle screws and can be heavily influenced by the screw design, the insertion technique and the quality of surrounding bone. The purpose of this study was to investigate the pullout strength of three different pedicle screws inserted using three different strategies and with two different loading conditions. Three pedicle screws with different thread designs (single-lead-thread (SLT) screw, dual-lead-thread (DLT) screw and mixed-single-lead-thread (MSLT) screw) were inserted into a pre-drilled rigid polyurethane foam block using three strategies: (A) screw inserted to a depth of 33.5 mm; (B) screw inserted to a depth of 33.5 mm and then reversed by 3.5 mm to simulate an adjustment of the tulip height of the pedicle screw and (C) screw inserted to a depth of 30 mm. After insertion, each screw type was set up with and without a cyclic load being applied to the screw head prior to the pullout test. To ensure that the normality assumption is met, we applied the Shapiro-Wilk test to all datasets before conducting the non-parametric statistical test (Kruskal-Wallis test combined with pairwise Mann-Whitney-U tests). All screw types inserted using strategy A had a significantly greater pullout strength than those inserted using strategies B and C, regardless of if the screw was pre-loaded with a cyclic load prior to testing. Without the use of the cyclic pre-load, the MSLT screw had a greater pullout strength than the SLT and DLT screws for all three insertion strategies. However, the fixation strength of all screws was reduced when pre-loaded before testing, with the MSLT screw inserted using strategy B producing a significantly lower pullout strength than all other groups (p < 0.05). In contrast, the MSLT screw using insertion strategies A and C had a greater pullout strength than the SLT and DLT screws both with and without pre-loading. In conclusion, the MSLT pedicle screw exhibited the greatest pullout strength of the screws tested under all insertion strategies and loading conditions, except for insertion strategy B with a cyclic pre-load. While all screw types showed a reduced pullout strength when using insertion strategy B (screw-out depth adjustment), the MSLT screw had the largest reduction in pullout strength when using a pre-load before testing. Based on these findings, during the initial screw insertion, it is recommended to not fully insert the screw thread into the bone and to leave a retention length for depth adjustment to avoid the need for screw-out adjustment, as with insertion strategy B.

17.
Int J Surg ; 109(8): 2427-2434, 2023 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-37161585

RESUMEN

INTRODUCTION: Trigger finger (TF) often occurs after carpal tunnel release (CTR), but the mechanism and outcomes remain inconsistent. This study evaluated the incidence of TF after CTR and its related risk factors. MATERIALS AND METHODS: ​PubMed, Embase, and Scopus databases were searched up to 27 August 2022, with the following keywords: "carpal tunnel release" and "trigger finger". Studies with complete data on the incidence of TF after CTR and published full text. The primary outcome was the association between CTR and the subsequent occurrence of the TF and to calculate the pooled incidence of post-CTR TF. The secondary outcomes included the potential risk factors among patients with and without post-CTR TF as well as the prevalence of the post-CTR TF on the affected digits. RESULTS: Ten studies with total 10,399 participants in 9 studies and 875 operated hands in one article were included for meta-analysis. CTR significantly increases the risk of following TF occurrence (odds ratio=2.67; 95% CI 2.344-3.043; P <0.001). The pooled incidence of TF development after CTR was 7.7%. Women were more likely to develop a TF after CTR surgery (odds ratio=2.02; 95% CI 1.054-3.873; P =0.034). Finally, the thumb was the most susceptible fingers, followed by middle and ring fingers. CONCLUSIONS: High incidence of TF comes after CTR, and women were more susceptible than man. Clinicians were suggested to notice the potential risk of TF after CTR in clinical practice. LEVEL OF EVIDENCE: Level III, meta-analysis.


Asunto(s)
Síndrome del Túnel Carpiano , Trastorno del Dedo en Gatillo , Masculino , Humanos , Femenino , Incidencia , Síndrome del Túnel Carpiano/epidemiología , Síndrome del Túnel Carpiano/cirugía , Factores de Riesgo , Trastorno del Dedo en Gatillo/epidemiología , Trastorno del Dedo en Gatillo/cirugía , Trastorno del Dedo en Gatillo/complicaciones , Pulgar
18.
Healthcare (Basel) ; 11(8)2023 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-37107992

RESUMEN

The erector spinae plane block (ESPB) at the level of the fifth thoracic vertebra (T5) is a novel technique, first published in 2016, which was found to be effective in both acute and chronic pain control. The mechanism of action and spread of local anesthetic of the ESPB at the lumbar region are thought to differ from those of the thoracic ESPB; however, the difference in onset time has never been evaluated. As for the onset of lumbar ESPBs, we presented three cases: two received lumbar ESPBs (one with chronic low back pain and one with acute postoperative hip pain), and the third one with chronic back pain received a thoracic ESPB. We administered 30 mL of 0.3% ropivacaine in all three patients, but the analgesic effect did not reach its maximum until 3 and 1.5 h, respectively, in the lumbar ESPB cases. On the contrary, the thoracic ESPB case experienced noticeable pain relief within 30 min. The onset time was considerably longer than that reported in earlier reports on ESPBs, and the lumbar ESPB achieved its peak effect much later than the thoracic ESPB using the same formula of local anesthetic. While the delayed-onset lumbar ESPB may have some drawbacks for treating acute postoperative pain, it still could produce significant analgesia, once it took effect, when given to patients suffering from hip surgery with large incisions and intractable low back pain. The current data suggested that the onset time of a lumbar ESPB may be delayed compared with its thoracic counterpart. Therefore, the local anesthetic formula and injection timing should be adjusted for a lumbar ESPB when applied in the perioperative period to make the onset of the analgesic effect coincide with the immediate postoperative pain. Without this concept in mind, clinicians may consider a lumbar ESPB to be ineffective before it takes effect, and consequently treat the patients inadequately with this technique. Future randomized controlled trials should be designed according to our observations to compare lumbar ESPB with its thoracic counterpart regarding onset time.

19.
J Shoulder Elbow Surg ; 32(6): 1314-1322, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36871608

RESUMEN

HYPOTHESIS: Adhesive capsulitis (AC) is a common clinical condition of the shoulders without a clear pathophysiology or etiology. Although thyroid disease has been linked to AC, an appropriate understanding of the disease and its epidemiological evidence are lacking. This metaanalysis investigated the association of AC with thyroid disease and identified which manifestations of thyroid disease contribute to the risk of AC. MATERIALS AND METHODS: The databases of PubMed, Embase, and Scopus were searched for literature retrieval up to September 20, 2022. Articles evaluating the association between AC and any type of thyroid disease were enrolled. Data from studies reporting the prevalence and its 95% confidence interval (CI) were pooled. Subgroup analysis was performed on the different manifestations of thyroid disease. We explored heterogeneity with sensitivity analyses and publication bias with funnel plots and Egger's tests. A trim and fill analysis was conducted if publication bias was found. RESULTS: Results: In total, 10 case-control studies comprising a total of 127,967 patients were included. The prevalence of thyroid disease was significantly higher in patients with AC (odds ratio [OR] = 1.87, 95% CI: 1.37-2.57, P < .0001) than in patients without AC. The results of subgroup analysis indicated significantly higher rates of hypothyroidism (OR = 1.92, 95% CI: 1.09-3.39, P = .02) and subclinical hypothyroidism (OR = 2.56, 95% CI: 1.81-3.63, P < .00001), but not hyperthyroidism (OR = 1.42, 95% CI: 0.63-3.22, P = .40), among patients with AC than among those without AC. CONCLUSIONS: Our meta-analysis demonstrated that thyroid disease, especially when presenting as hypothyroidism or subclinical hypothyroidism, is associated with an increased risk of AC. Evidence for an association between hyperthyroidism and AC was not found, although this may be due to the lack of related studies. Further research on the pathogeneses of and relationship between these two diseases is warranted.


Asunto(s)
Bursitis , Hipertiroidismo , Hipotiroidismo , Humanos , Estudios de Casos y Controles , Hipertiroidismo/complicaciones , Hipertiroidismo/epidemiología , Hipotiroidismo/complicaciones , Hipotiroidismo/epidemiología , Prevalencia , Enfermedades de la Tiroides/complicaciones , Enfermedades de la Tiroides/epidemiología
20.
J Orthop Surg Res ; 18(1): 182, 2023 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-36894998

RESUMEN

BACKGROUND: Hip fracture is a common but devastating disease with a high mortality rate in the older adult population. C-reactive protein (CRP) is a predictor of the prognosis in many diseases, but its correlations with patient outcomes following hip fracture surgery remain unclear. In this meta-analysis, we investigated the correlation between perioperative CRP level and postoperative mortality in patients undergoing hip fracture surgery. METHODS: PubMed, Embase, and Scopus were searched for relevant studies published before September 2022. Observational studies investigating the correlation between perioperative CRP level and postoperative mortality in patients with hip fracture were included. The differences in CRP levels between the survivors and nonsurvivors following hip fracture surgery were measured with mean differences (MDs) and 95% confidence intervals (CIs). RESULTS: Fourteen prospective and retrospective cohort studies comprising 3986 patients with hip fracture were included in the meta-analysis. Both the preoperative and postoperative CRP levels were significantly higher in the death group than in the survival group when the follow-up duration was ≥ 6 months (MD: 0.67, 95% CI: 0.37-0.98, P < 0.0001; MD: 1.26, 95% CI: 0.87-1.65, P < 0.00001, respectively). Preoperative CRP levels were significantly higher in the death group than in the survival group when the follow-up duration was ≤ 30 days (MD: 1.49, 95% CI: 0.29-2.68; P = 0.01). CONCLUSIONS: Both higher preoperative and postoperative CRP levels were correlated with higher risk of mortality following hip fracture surgery, suggesting the prognostic role of CRP. Further studies are warranted to confirm the ability of CRP to predict postoperative mortality in patients with hip fracture.


Asunto(s)
Proteína C-Reactiva , Fracturas de Cadera , Humanos , Anciano , Proteína C-Reactiva/metabolismo , Estudios Retrospectivos , Estudios Prospectivos , Complicaciones Posoperatorias/epidemiología , Fracturas de Cadera/epidemiología , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...