Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Heliyon ; 10(6): e28142, 2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38533048

RESUMEN

Rationale and objectives: Aim of this study was to assess the impact of contrast media dose (CMD) reduction on diagnostic quality of photon-counting detector CT (PCD-CT) and energy-integrating detector CT (EID-CT). Methods: CT scans of the abdominal region with differing CMD acquired in portal venous phase on a PCD-CT were included and compared to EID-CT scans. Diagnostic quality and contrast intensity were rated. Additionally, readers had to assign the scans to reduced or regular CMD. Regions-of-interest (ROIs) were placed in defined segments of portal vein, inferior vena cava, liver, spleen, kidneys, abdominal aorta and muscular tissue. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Results: Overall 158 CT scans performed on a PCD-CT and 68 examinations on an EID-CT were analyzed. Overall diagnostic quality showed no significant differences for PCD-CT with standard CMD which scored a median 5 (IQR:5-5) and PCD-CT with 70% CMD scoring 5 (4-5). (For PCD-CT, 71.69% of the examinations with reduced CMD were assigned to regular CMD by the readers, for EID-CT 9.09%. Averaged for all measurements SNR for 50% CMD was reduced by 19% in PCD-CT (EID-CT 34%) and CNR by 48% (EID-CT 56%). Virtual monoenergetic images (VMI)50keV for PCD-CT images acquired with 50% CMD showed an increase in SNR by 72% and CNR by 153%. Conclusions: Diagnostic interpretability of PCD-CT examinations with reduction of up to 50% CMD is maintained. PCD-CT deducted scans especially with 70% CMD were often not recognized as CMD reduced scans. Compared to EID-CT less decline in SNR and CNR is observed for CMD reduced PCD-CT images. Employing VMI50keV for CMD-reduced PCD-CT images compensated for the effects.

2.
Sci Rep ; 14(1): 497, 2024 01 04.
Artículo en Inglés | MEDLINE | ID: mdl-38177651

RESUMEN

Aim of this study was to assess the impact of virtual monoenergetic images (VMI) on dental implant artifacts in photon-counting detector computed tomography (PCD-CT) compared to standard reconstructed polychromatic images (PI). 30 scans with extensive (≥ 5 dental implants) dental implant-associated artifacts were retrospectively analyzed. Scans were acquired during clinical routine on a PCD-CT. VMI were reconstructed for 100-190 keV (10 keV steps) and compared to PI. Artifact extent and assessment of adjacent soft tissue were rated using a 5-point Likert grading scale for qualitative assessment. Quantitative assessment was performed using ROIs in most pronounced hypodense and hyperdense artifacts, artifact-impaired soft tissue, artifact-free fat and muscle tissue. A corrected attenuation was calculated as difference between artifact-impaired tissue and tissue without artifacts. Qualitative assessment of soft palate and cheeks improved for all VMI compared to PI (Median PI: 1 (Range: 1-3) and 1 (1-3); e.g. VMI130 keV 2 (1-5); p < 0.0001 and 2 (1-4); p < 0.0001). In quantitative assessment, VMI130 keV showed best results with a corrected attenuation closest to 0 (PI: 30.48 ± 98.16; VMI130 keV: - 0.55 ± 73.38; p = 0.0026). Overall, photon-counting deducted VMI reduce the extent of dental implant-associated artifacts. VMI of 130 keV showed best results and are recommended to support head and neck CT scans.


Asunto(s)
Implantes Dentales , Artefactos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Mejilla , Relación Señal-Ruido , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
3.
Sci Rep ; 13(1): 8955, 2023 06 02.
Artículo en Inglés | MEDLINE | ID: mdl-37268675

RESUMEN

Aim of this study was to assess the impact of virtual monoenergetic images (VMI) in combination and comparison with iterative metal artifact reduction (IMAR) on hip prosthesis-associated artifacts in photon-counting detector CT (PCD-CT). Retrospectively, 33 scans with hip prosthesis-associated artifacts acquired during clinical routine on a PCD-CT between 08/2022 and 09/2022 were analyzed. VMI were reconstructed for 100-190 keV with and without IMAR, and compared to polychromatic images. Qualitatively, artifact extent and assessment of adjacent soft tissue were rated by two radiologists using 5-point Likert items. Quantitative assessment was performed measuring attenuation and standard deviation in most pronounced hypodense and hyperdense artifacts, artifact-impaired bone, muscle, vessels, bladder and artifact-free corresponding tissue. To quantify artifacts, an adjusted attenuation was calculated as the difference between artifact-impaired tissue and corresponding tissue without artifacts. Qualitative assessment improved for all investigated image reconstructions compared to polychromatic images (PI). VMI100keV in combination with IMAR achieved best results (e.g. diagnostic quality of the bladder: median PI: 1.5 (range 1-4); VMI100keV+IMAR: 5 (3-5); p < 0.0001). In quantitative assessment VMI100keV with IMAR provided best artifact reduction with an adjusted attenuation closest to 0 (e.g. bone: PI: 302.78; VMI100keV+IMAR: 51.18; p < 0.0001). The combination of VMI and IMAR significantly reduces hip prosthesis-associated artifacts in PCD-CT and improves the diagnostic quality of surrounding tissue.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Estudios Retrospectivos , Metales , Tomografía Computarizada por Rayos X/métodos , Artefactos , Algoritmos
4.
Acta Radiol ; 64(4): 1322-1330, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36128748

RESUMEN

BACKGROUND: Complication rates in percutaneous transhepatic biliary drainage (PTBD) are non-uniform and vary considerably. In addition, the impact of peri-procedural risk factors is under-investigated. PURPOSE: To compare success and complication rates of PTBD in patients with and without accompanying technical risk factors. MATERIAL AND METHODS: A single-center retrospective study was conducted from January 2004 to December 2016. Patients receiving PTBD due to biliary obstruction or biliary leakage were included. Technical risk factors (non-distended bile ducts, ascites, obesity, anasarca, non-compliance) were assessed. Complications were classified according to the Society of Interventional Radiology. RESULTS: In total, 372 patients were included (57.3% men, 42.7% women; mean age = 66 years). Overall, 466 PTBDs were performed. Of the patients, 70.1% presented with malignancy and biliary obstruction; 26.8% had benign biliary obstruction; 3.1% had biliary leakage. Technical risk factors were reported in 57 (15.3%) patients. Overall technical success of initial PTBD was 98.7%, primary technical success was 97.9%. In patients with non-dilatated bile ducts, primary technical success was 68.2%. Overall complication rate was 15.0% (8.1% major complications, 6.9% minor complications). Neither major nor minor complications were more frequent in patients with technical risk factors (P > 0.05). In left-sided PTBD, hemorrhage was more frequent (P = 0.015). Patients with malignancy were significantly more affected by drainage-related complications (P = 0.004; odds ratio = 2.03). The mortality rate was 0.5% (n = 2). CONCLUSION: PTBD is a safe and effective method for the treatment of biliary obstruction and biliary leaks. Complication rates are low, even in procedures with risk factors.


Asunto(s)
Conductos Biliares , Colestasis , Masculino , Humanos , Femenino , Anciano , Estudios Retrospectivos , Colestasis/diagnóstico por imagen , Colestasis/cirugía , Drenaje , Resultado del Tratamiento
5.
Sci Rep ; 12(1): 9422, 2022 06 08.
Artículo en Inglés | MEDLINE | ID: mdl-35676399

RESUMEN

We aimed to investigate the diagnostic utility of MRI extracellular volume fraction (ECV) for the assessment of liver cirrhosis severity as defined by Child-Pugh class. In this retrospective study, 90 patients (68 cirrhotic patients and 22 controls), who underwent multiparametric liver MRI, were identified. Hepatic T1 relaxation times and ECV were assessed. Clinical scores of liver disease severity were calculated. One-way analysis of variance (ANOVA) followed by Tukey's multiple comparison test, Spearman's correlation coefficient, and receiver operating characteristic (ROC) analysis were used for statistical analysis. In cirrhotic patients, hepatic native T1 increased depending on Child-Pugh class (620.5 ± 78.9 ms (Child A) vs. 666.6 ± 73.4 ms (Child B) vs. 828.4 ± 91.2 ms (Child C), P < 0.001). ECV was higher in cirrhotic patients compared to the controls (40.1 ± 11.9% vs. 25.9 ± 4.5%, P < 0.001) and increased depending of Child-Pugh class (33.3 ± 6.0% (Child A) vs. 39.6 ± 4.9% (Child B) vs. 52.8 ± 1.2% (Child C), P < 0.001). ECV correlated with Child-Pugh score (r = 0.64, P < 0.001). ECV allowed differentiating between Child-Pugh classes A and B, and B and C with an AUC of 0.785 and 0.944 (P < 0.001, respectively). The diagnostic performance of ECV for differentiating between Child-Pugh classes A and B, and B and C was higher compared to hepatic native T1 (AUC: 0.651 and 0.910) and MELD score (AUC: 0.740 and 0.795) (P < 0.05, respectively). MRI-derived ECV correlated with Child-Pugh score and had a high diagnostic performance for the discrimination of different Child-Pugh classes. ECV might become a valuable non-invasive biomarker for the assessment of liver cirrhosis severity.


Asunto(s)
Cirrosis Hepática , Imagen por Resonancia Magnética , Humanos , Hígado/diagnóstico por imagen , Hígado/patología , Cirrosis Hepática/patología , Curva ROC , Estudios Retrospectivos
6.
Cardiovasc Intervent Radiol ; 45(8): 1207-1213, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35764819

RESUMEN

PURPOSE: To evaluate technical feasibility and safety of common endovascular visceral interventions using a vascular robotic platform through preclinical study. MATERIAL AND METHODS: The CorPath GRX Robotic System (Corindus Inc, Waltham, Massachusetts) was tested in an anesthetized pig for its ability to navigate various commercially available devices in the abdominal vasculature and to perform routine endovascular visceral procedures. After manually placing a guiding catheter in the celiac trunk, several visceral branches were probed with microcatheters and -wires under robotic assistance, and embolization with liquids (lipiodol), detachable coils and plugs were performed. Furthermore, the origin of the celiac trunk was stented before accessing the left hypogastric artery for pelvic embolization. RESULTS: All procedures were performed with technical success and without any complications. Navigating the catheters and wires via the steering console proved intuitive. Coil, plug and stent deployment were exclusively controlled by remote with remarkable precision and stability. CONCLUSION: Robotic-assisted visceral embolization and stenting as well as pelvic embolization using the CorPath GRX System is feasible and safe. Application of the platform in the abdominal vasculature is demonstrated for the first time. Considering the precision and the potential for reducing the operator's radiation exposure, further research in this area is highly encouraged to enable translation into clinical practice.


Asunto(s)
Procedimientos Endovasculares , Procedimientos Quirúrgicos Robotizados , Animales , Procedimientos Endovasculares/métodos , Estudios de Factibilidad , Procedimientos Quirúrgicos Robotizados/métodos , Stents , Porcinos , Resultado del Tratamiento
7.
Invest Radiol ; 57(7): 470-477, 2022 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-35136004

RESUMEN

OBJECTIVE: Robust dynamic contrast-enhanced T1-weighted images are crucial for accurate detection and categorization of focal liver lesions in liver/abdominal magnetic resonance imaging (MRI). As optimal dynamic imaging usually requires multiple breath-holds, its inherent susceptibility to motion artifacts frequently results in degraded image quality in incompliant patients. Because free-breathing imaging may overcome this drawback, the intention of this study was to evaluate a dynamic MRI sequence acquired during free breathing using the variable density, elliptical centric golden angle radial stack-of-stars radial sampling scheme, which so far has not been implemented in 4-dimensional applications. MATERIALS AND METHODS: In a prospective pilot study, 27 patients received a routine abdominal MRI protocol including the prototype free-breathing sequence (4DFreeBreathing) for dynamic imaging. This enables more convenient and faster reconstruction through variable density, elliptical centric golden angle radial stack-of-stars without the use of additional reconstruction hardware, and even higher motion robustness through soft-gating. A standard breath-hold sequence performed subsequently served as reference standard. Of the continuous dynamic data sets, each dynamic phase was analyzed regarding image quality, motion artifacts and vessel conspicuity using 5-point Likert scales. Furthermore, correct timing of the late arterial phase was compared with the preexaminations. RESULTS: 4DFreeBreathing delivered motion-free dynamic images with high temporal resolution in each subject. Overall image quality scores were rated good or excellent for 4DFreeBreathing and the gold standard without significant differences (P = 0.34). There were significantly less motion artifacts in the 4DFreeBreathing sequence (P < 0.0001), whereas vessel conspicuity in each dynamic phase was comparable for both groups (P = 0.45, P > 0.99, P = 0.22, respectively). Correct timing of the late arterial phase could be achieved in 27 of 27 (100%) examinations using 4DFreeBreathing versus 35 of 53 (66%) preexaminations using gold standard (P < 0.001). CONCLUSION: The benefit of convenient and fast image reconstruction combined with the superiority in motion robustness and timing compared with standard breath hold sequences renders 4DFreeBreathing an attractive alternative to existing free-breathing techniques in dynamic liver MRI.


Asunto(s)
Medios de Contraste , Aumento de la Imagen , Artefactos , Estudios de Factibilidad , Humanos , Aumento de la Imagen/métodos , Imagenología Tridimensional/métodos , Hígado/diagnóstico por imagen , Hígado/patología , Imagen por Resonancia Magnética/métodos , Proyectos Piloto , Estudios Prospectivos , Respiración
8.
Radiology ; 300(3): 633-640, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34184931

RESUMEN

Background Cervical spine CT is regularly performed to exclude cervical spine injury during the initial evaluation of trauma patients. Patients with asymmetry of the lateral atlantodental interval (LADI) often undergo subsequent MRI to rule out ligamentous injuries. The clinical relevance of an asymmetric LADI and the benefit of additional MRI remain unclear. Purpose To evaluate the diagnostic benefit of additional MRI in patients with blunt trauma who have asymmetry of the LADI and no other cervical injuries. Materials and Methods Patients who underwent cervical spine CT during initial trauma evaluation between March 2017 and August 2019 were retrospectively evaluated. Those who underwent subsequent MRI because of LADI asymmetry of 1 mm or greater with no other signs of cervical injury were identified and reevaluated by two readers blinded to clinical data and initial study reports regarding possible ligamentous injuries. Results Among 1553 patients, 146 (9%) had LADI asymmetry of 1 mm or greater. Of these, 46 patients (mean age ± standard deviation, 39 years ± 22; 28 men; median LADI asymmetry, 2.4 mm [interquartile range, 1.8-3.1 mm]) underwent supplementary MRI with no other signs of cervical injury at initial CT. Ten of the 46 patients (22%) showed cervical tenderness at clinical examination, and 36 patients (78%) were asymptomatic. In two of the 46 patients (4%), MRI revealed alar ligament injury; both of these patients showed LADI asymmetry greater than 3 mm, along with cervical tenderness at clinical examination, and underwent treatment for ligamentous injury. In 13 of the 46 patients (28%), signal intensity alterations of alar ligaments without signs of rupture were observed. Four of these 13 patients (31%) were subsequently treated for ligamentous injury despite being asymptomatic. Conclusion Subsequent MRI following CT of the cervical spine in trauma patients with lateral atlantodental interval asymmetry may have diagnostic benefit only in symptomatic patients. In asymptomatic patients without proven cervical injuries, subsequent MRI showed no diagnostic benefit and may even lead to overtreatment. © RSNA, 2021 Online supplemental material is available for this article.


Asunto(s)
Vértebras Cervicales/lesiones , Ligamentos Articulares/lesiones , Imagen por Resonancia Magnética/métodos , Traumatismos Vertebrales/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Heridas no Penetrantes/diagnóstico por imagen , Adulto , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Estudios Retrospectivos
9.
Rofo ; 193(7): 813-821, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33535259

RESUMEN

PURPOSE: Compressed sensing (CS) is a method to accelerate MRI acquisition by acquiring less data through undersampling of k-space. In this prospective study we aimed to evaluate whether a three-dimensional (3D) isotropic proton density-weighted fat saturated sequence (PDwFS) with CS can replace conventional multidirectional two-dimensional (2D) sequences at 1.5 Tesla. MATERIALS AND METHODS: 20 patients (45.2 ±â€Š20.2 years; 10 women) with suspected internal knee damage received a 3D PDwFS with CS acceleration factor 8 (acquisition time: 4:11 min) in addition to standard three-plane 2D PDwFS sequences (acquisition time: 4:05 min + 3:03 min + 4:46 min = 11:54 min) at 1.5 Tesla. Scores for homogeneity of fat saturation, image sharpness, and artifacts were rated by two board-certified radiologists on the basis of 5-point Likert scales. Based on these ratings, an overall image quality score was generated. Additionally, quantitative contrast ratios for the menisci (MEN), the anterior (ACL) and the posterior cruciate ligament (PCL) in comparison with the popliteus muscle were calculated. RESULTS: The overall image quality was rated superior in 3D PDwFS compared to 2D PDwFS sequences (14.45 ±â€Š0.83 vs. 12.85 ±â€Š0.99; p < 0.01), particularly due to fewer artifacts (4.65 ±â€Š0.67 vs. 3.65 ±â€Š0.49; p < 0.01) and a more homogeneous fat saturation (4.95 ±â€Š0.22 vs. 4.55 ±â€Š0.51; p < 0.01). Scores for image sharpness were comparable (4.80 ±â€Š0.41 vs. 4.65 ±â€Š0.49; p = 0.30). Quantitative contrast ratios for all measured structures were superior in 3D PDwFS (MEN: p < 0.05; ACL: p = 0.06; PCL: p = 0.33). In one case a meniscal tear was only diagnosed using multiplanar reformation of 3D PDwFS, but it would have been missed on standard multiplanar 2D sequences. CONCLUSION: An isotropic fat-saturated 3D PD sequence with CS enables fast and high-quality 3D imaging of the knee joint at 1.5 T and may replace conventional multiplanar 2D sequences. Besides faster image acquisition, the 3D sequence provides advantages in small structure imaging by multiplanar reformation. KEY POINTS: · 3D PDwFS with compressed sensing enables knee imaging that is three times faster compared to multiplanar 2D sequences. · 3D PDwFS with compressed sensing provides high-quality knee imaging at 1.5 T. · Isotropic 3D sequences provide advantages in small structure imaging by using multiplanar reformations. CITATION FORMAT: · Endler CH, Faron A, Isaak A et al. Fast 3D Isotropic Proton Density-Weighted Fat-Saturated MRI of the Knee at 1.5 T with Compressed Sensing: Comparison with Conventional Multiplanar 2D Sequences. Fortschr Röntgenstr 2021; 193: 813 - 821.


Asunto(s)
Imagenología Tridimensional , Traumatismos de la Rodilla/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Artefactos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Adulto Joven
10.
Catheter Cardiovasc Interv ; 91(4): 774-782, 2018 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-28547872

RESUMEN

OBJECTIVES: To investigate the impact of aortic valve calcification and brain morphology on acute peri-procedural cerebrovascular events (CVEs) in patients undergoing transcatheter aortic valve implantation (TAVI). BACKGROUND: Aortic valve calcification and stenosis can be assessed with echocardiography. Cerebral magnetic resonance imaging (MRI) depicts and quantifies morphological signs of hypoperfusion and vascular embolism, which is of special interest in patients with severe aortic stenosis. Furthermore, subjects who undergo TAVI are prone to suffer of clinically silent peri-procedural CVEs. METHODS: A total of 119 patients referred to TAVI were investigated for aortic valve calcification using trans-esophageal echocardiography. Cerebral MRI prior to and immediate after implantation was performed in all patients using a dedicated scan protocol. Prior to TAVI, brain morphology was characterized. Post TAVI, brains were investigated for the onset of acute peri-procedural CVEs using diffusion weighted imaging (DWI). RESULTS: Seventy-eight patients (65.5%) revealed acute peri-procedural CVEs on MRI after TAVI with a favor of the left hemisphere (57.5%). The degree of valve calcification was associated with peri-procedural CVEs. Patients with a high WML burden had an increased risk for CVEs ((OR) 2.36 (95% CI: 1.09-5.15; P = 0.037)), especially when distributed periventricular ((OR: 3.27; 95% CI: 1.47-7.26; P = 0.0038)). CONCLUSION: In patients undergoing TAVI, the degree of aortic valve calcification and periventricular WML burden were correlated with acute peri-procedural CVEs. Future studies are needed to evaluate their independent value for the long-term clinical outcome.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/patología , Válvula Aórtica/cirugía , Calcinosis/cirugía , Trastornos Cerebrovasculares/etiología , Leucoencefalopatías/complicaciones , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Enfermedades Asintomáticas , Calcinosis/complicaciones , Calcinosis/diagnóstico por imagen , Calcinosis/fisiopatología , Trastornos Cerebrovasculares/diagnóstico por imagen , Trastornos Cerebrovasculares/fisiopatología , Imagen de Difusión por Resonancia Magnética , Ecocardiografía Transesofágica , Femenino , Hemodinámica , Humanos , Leucoencefalopatías/diagnóstico por imagen , Masculino , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
11.
Magn Reson Imaging ; 33(10): 1258-1266, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26271178

RESUMEN

OBJECTIVES: To intraindividually compare gadoxetate disodium and gadofosveset trisodium regarding vessel contrast, image quality and vessel delineation in dynamic contrast-enhanced liver MRI at 3.0T. METHODS: Twelve patients underwent 3.0T MRI twice (24 examinations) with a single dose of gadoxetate disodium and gadofosveset trisodium, respectively. Signal intensity in abdominal vessels and tissue was determined. Vessel-to-background ratio (VBR) was calculated for each vessel and dynamic phase. All images were evaluated by two radiologists regarding image quality, vessel delineation and anatomic variants or pathologies with digital subtraction angiography as the standard of reference. RESULTS: Gadofosveset trisodium demonstrated a significantly higher VBR compared to gadoxetate disodium (arterial phase: 0.57±0.12 [SD] vs. 0.46±0.19; portal venous phase: 0.51±0.11 vs. 0.37±0.14; equilibrium phase: 0.48±0.10 vs. 0.31±0.13; p≤0.01). Image quality and vessel delineation were rated equal or better for gadofosveset trisodium in all cases. These differences were not significant for most vessel segments. All anatomic variants were correctly identified by both readers for both contrast agents. CONCLUSIONS: Although gadofosveset trisodium provides a significantly higher vessel contrast at 3.0T, gadoxetate disodium is equivalent by qualitative measurements. Thus, gadoxetate-enhanced liver MRI at 3.0T enables reliable assessment of the upper abdominal vasculature with the additional benefit of hepatobiliary imaging.


Asunto(s)
Medios de Contraste , Gadolinio DTPA , Gadolinio , Aumento de la Imagen , Hígado/irrigación sanguínea , Imagen por Resonancia Magnética , Compuestos Organometálicos , Anciano , Angiografía de Substracción Digital , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
12.
Eur Radiol ; 25(11): 3207-13, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25903709

RESUMEN

OBJECTIVES: Our aim was to retrospectively evaluate the occurrence of respiratory motion artefacts in patients undergoing dynamic liver magnetic resonance (MR) either with gadoxetate disodium or gadobutrol. METHODS: Two hundred and thirty liver MR studies (115 with gadobutrol, 115 with gadoxetate disodium) were analysed. Respiratory motion artefacts on dynamic 3D T1-weighted MR images (pre-contrast, arterial, venous, and late-dynamic phase) were assessed using a five-point rating scale. Severe motion was defined as a score ≥ 4. Mean motion scores were compared with the Mann-Whitney-U-test. The chi-squared-test was used for dichotomous comparisons. RESULTS: Mean motion scores for gadoxetate disodium and gadobutrol showed no relevant differences for each phase of the dynamic contrast series (pre-contrast: 1.85 ± 0.70 vs. 1.88 ± 0.57, arterial: 1.85 ± 0.81 vs. 1.87 ± 0.74, venous: 1.82 ± 0.67 vs. 1.74 ± 0.64, late-dynamic: 1.75 ± 0.62 vs. 1.79 ± 0.63; p = 0.469, 0.557, 0.382 and 0.843, respectively). Severe motion artefacts had a similar incidence using gadoxetate disodium and gadobutrol (11/460 [2.4%] vs. 7/460 [1.5%]; p = 0.341). CONCLUSIONS: Gadoxetate disodium is associated with equivalent motion scores compared to gadobutrol in dynamic liver MRI. In addition, both contrast agents demonstrated a comparable and acceptable rate of severe respiratory motion artefacts. KEY POINTS: • Gadobutrol and gadoxetate disodium showed comparable motion scores in dynamic phase imaging. • The incidence of severe motion artefacts was pronounced in arterial phase imaging. • Adverse respiratory side effects were not recorded in 115 examinations with gadoxetate disodium.


Asunto(s)
Artefactos , Medios de Contraste , Gadolinio DTPA , Cirrosis Hepática/patología , Hepatopatías/patología , Compuestos Organometálicos , Adulto , Anciano , Anciano de 80 o más Años , Arterias , Femenino , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Movimiento (Física) , Respiración , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...