Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Diagnostics (Basel) ; 13(5)2023 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-36900133

RESUMEN

OBJECTIVES: Measurement location and patient state can impact noninvasive liver assessment and change clinical staging in ultrasound examinations. Research into differences exists for Shear Wave Speed (SWS) and Attenuation Imaging (ATI), but not for Shear Wave Dispersion (SWD). The aim of this study is to assess the effect of breathing phase, liver lobe, and prandial state on SWS, SWD, and ATI ultrasound measurements. METHODS: Two experienced examiners performed SWS, SWD, and ATI measurements in 20 healthy volunteers using a Canon Aplio i800 system. Measurements were taken in the recommended condition (right lobe, following expiration, fasting state), as well as (a) following inspiration, (b) in the left lobe, and (c) in a nonfasting state. RESULTS: SWS and SWD measurements were strongly correlated (r = 0.805, p < 0.001). Mean SWS was 1.34 ± 0.13 m/s in the recommended measurement position and did not change significantly under any condition. Mean SWD was 10.81 ± 2.05 m/s/kHz in the standard condition and significantly increased to 12.18 ± 1.41 m/s/kHz in the left lobe. Individual SWD measurements in the left lobe also had the highest average coefficient of variation (19.68%). No significant differences were found for ATI. CONCLUSION: Breathing and prandial state did not significantly affect SWS, SWD, and ATI values. SWS and SWD measurements were strongly correlated. SWD measurements in the left lobe showed a higher individual measurement variability. Interobserver agreement was moderate to good.

2.
PLoS One ; 13(7): e0200473, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29990381

RESUMEN

OBJECTIVE: The dual-energy CT (DECT) algorithm for urate detection is feasible only if hyperdense deposits are present. Based on our experience, around half of the performed DECT examinations show no such deposits and thus were useless for this indication. Our diagnostic accuracy study investigates whether conventional radiographs can serve as gatekeeper test prior to DECT for reliable exclusion of such radiopaque deposits. MATERIALS AND METHODS: In this retrospective study, 77 clinically indicated DECT examinations of the hand (n = 29), foot (n = 36) and ankle (n = 12) of 55 patients (13 female, mean age 62±15 years) with suspected gouty arthritis were included. Two blinded readers independently evaluated DECT, gray-scale CT images (reference standard) and corresponding standardized radiographs for the presence/location of dense soft tissue deposits. RESULTS: Interreader agreement for detection of soft tissue deposits with DECT and radiographs was excellent (DECT: both readers, κ = 1; radiographs: both readers, κ = 0.94). DECT showed soft tissue deposits in 54/77 DECT (70%) scans. 30/54 scans (56%) showed deposits on the corresponding radiographs, while in 24 scans (44%) no deposits were seen on radiographs. Test performance of radiographs for soft tissue deposit detection: sensitivity 56%, specificity 100%, PPV 100%, NPV 48.9%, and accuracy 69%. Low density of the deposits was the main reasons for false-negative radiographs (19 cases, 79%), followed by superimposition of deposits by osseous structures (5 cases, 21%). CONCLUSION: Conventional radiographs of the hand, foot and ankle cannot serve as a gatekeeper test for reliable exclusion of radiopaque soft tissue deposits prior to DECT.


Asunto(s)
Artritis Gotosa/diagnóstico por imagen , Imagen Radiográfica por Emisión de Doble Fotón , Adulto , Anciano , Algoritmos , Reacciones Falso Negativas , Femenino , Gota/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Interpretación de Imagen Radiográfica Asistida por Computador , Estudios Retrospectivos , Sensibilidad y Especificidad , Ácido Úrico/sangre
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...