Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 85(2): 02A735, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24593469

RESUMEN

A transverse beam emittance and acceptance measurement system has been developed to visualize the relationship between the injected beam emittance and the acceptance of a cyclotron. The system is composed of a steering magnet, two pairs of slits to limit the horizontal and vertical phase-space, a beam intensity detector just behind the slits for the emittance measurement, and a beam intensity detector in the cyclotron for the acceptance measurement. The emittance is obtained by scanning the slits and measuring the beam intensity distribution. The acceptance is obtained by measuring the distribution of relative beam transmission by injecting small emittance beams at various positions in a transverse phase-space using the slits. In the acceptance measurement, the beam from an ion source is deflected to the defined region by the slits using the steering magnet so that measurable acceptance area covers a region outside the injection beam emittance. Measurement tests were carried out under the condition of accelerating a beam of (16)O(6+) from 50.2 keV to 160 MeV. The emittance of the injected beam and the acceptance for accelerating and transporting the beam to the entrance of the extraction deflector were successfully measured. The relationship between the emittance and acceptance is visualized by displaying the results in the same phase-plane.

2.
Methods Inf Med ; 45(4): 462-9, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16964366

RESUMEN

OBJECTIVES: Activity-based costing (ABC) is widely used to precisely allocate indirect costs to medical services. In the ABC method, the indirect cost is divided among the medical services in proportion to the volume of "cost drivers", for example, labor hours and the number of hours of surgery. However, the workload of data collection of cost drivers can be time-consuming and a considerable burden if there are many cost drivers. The authors aim to develop a method for objectively reducing the cost drivers used in the ABC method. METHODS: In the ABC method, the cost driver is assigned for each activity. We assume that these activities and cost drivers are the best combination. Our method, that is cost driver reduction (CDR), can objectively select surrogates of the cost drivers for each activity in ABC from candidate cost drivers. Concretely, the total indirect cost of an activity is temporarily allocated to the medical services using each candidate of cost drivers. The difference between the costs calculated by each candidate and the proper cost driver used in ABC is calculated to evaluate the similarity by the evaluation function. RESULTS: We estimated the cost of laboratory tests using our method and revealed that the number of cost drivers could be reduced from seven in the ABC to four. Similarly, the results of cost estimation obtained by our method were as accurate as those calculated using the ABC. CONCLUSIONS: Our method provides two advantages compared to the ABC method: 1) it provides results that are as accurate as those of the ABC method, and 2) it is simpler to perform complicated estimation of hospital costs.


Asunto(s)
Contabilidad/métodos , Técnicas de Laboratorio Clínico/economía , Asignación de Costos/métodos , Administración Financiera de Hospitales/métodos , Costos de Hospital/estadística & datos numéricos , Laboratorios de Hospital/economía , Contabilidad/estadística & datos numéricos , Técnicas de Laboratorio Clínico/clasificación , Control de Costos , Recolección de Datos/métodos , Costos Directos de Servicios/estadística & datos numéricos , Administración Financiera de Hospitales/estadística & datos numéricos , Hospitales Universitarios/economía , Humanos , Japón , Laboratorios de Hospital/estadística & datos numéricos
3.
Biopolymers ; 53(6): 484-96, 2000 May.
Artículo en Inglés | MEDLINE | ID: mdl-10775064

RESUMEN

A new synthetic route to (E)-beta-phenyl-alpha,beta-dehydroalanine (delta(E)Phe)-containing peptide was presented via photochemical isomerization of the corresponding (Z)-beta-phenyl-alpha,beta-dehydroalanine (delta(Z)Phe)-containing peptide. By applying this method to Boc-Ala-delta(Z)Phe-Val-OMe (Z-I: Boc, t-butoxycarbonyl; OMe, methoxy), Boc-Ala-delta(E)Phe-Val-OMe (E-I) was obtained. The identification of peptide E-I was evidenced by 1H-nmr, 13C-nmr, and uv absorption spectroscopy, elemental analysis, and hydrogenation. The conformation of peptide E-I in CDCl3 was investigated by 1H-nmr spectroscopy (solvent dependence of NH chemical shift and difference nuclear Overhauser effect). Interestingly, peptide E-I differed from peptide Z-I in the hydrogen-bonding mode. Namely, for peptide Z-I, only Val NH participates in intramolecular hydrogen bonding, which leads to a type II beta-turn conformation supported by hydrogen bonding between CO(Boc) and NH(Val). On the other hand, for peptide E-I, two NHs, delta(E)Phe NH and Val NH, participate in intramolecular hydrogen bonding. In both peptides, a remarkable NOE (approximately 11-13%) was observed for Ala C(alpha) H-deltaPhe NH pair. Based on the nmr data and conformational energy calculation, it should be concluded that peptide E-I takes two consecutive gamma-turn conformations supported by hydrogen bonding between CO(Boc) and NH(delta(E)Phe), and between CO(Ala) and NH(Val) as its plausible conformation.


Asunto(s)
Péptidos/síntesis química , Fenilalanina , Péptidos/química , Conformación Proteica
5.
J Hematother ; 3(2): 128-33, 1994.
Artículo en Inglés | MEDLINE | ID: mdl-7522896

RESUMEN

An immunomagnetic separation system has been used to collect CD34+ cells in mobilized blood after treatment with a nylon-wool column. Cell purities were increased from 2.6% preseparation to 94.6% postseparation, with a mean yield 45.2% (n = 4). Forty percent of CD34+ cells separated by the immunomagnetic procedure formed colonies in the presence of hematopoietic growth factors in a limiting dilution assay. Eleven percent of these clones proliferated to over 10(5) cells and contained megakaryocytes.


Asunto(s)
Antígenos CD/sangre , Separación Inmunomagnética/instrumentación , Monocitos , Antígenos CD34 , Diferenciación Celular/inmunología , División Celular/inmunología , Células Clonales , Humanos , Técnicas de Dilución del Indicador , Recuento de Leucocitos , Monocitos/citología , Nylons
6.
Life Sci ; 47(11): 953-60, 1990.
Artículo en Inglés | MEDLINE | ID: mdl-2215077

RESUMEN

We have monitored the interaction of several lipids with the bovine brain calmodulin(CaM) and analyzed the effect of lysophosphatidylcholine(lyso-PC, 2-50 micrograms/ml) on conformation of CaM and the interaction between CaM and CaM-binding protein(CaMBP), using a fluorescence signal of 1-(dimethylamino)naphthalene-5-sulfonate-labeled CaM(DNS-CaM). Lyso-PC(egg, 20 micrograms/ml), among various natural lipids including phosphatidylserine(PS), phosphatidylinositol(PI), phosphatidylethanolamine (PE) and their lyso forms, greatly and dose-dependently enhanced the intensity of DNS fluorescence of DNS-CaM in the presence (100 microM CaCl2) and absence (1 mM EGTA) of Ca2+. Apparent dissociation constants calculated from the fluorometric titrations of binding of lyso-PC to DNS-CaM were 0.6 and 3.7 micrograms/ml in the presence and absence of Ca2+, respectively. Lyso-PC remarkably prevented both trypsin-induced quenching of the fluorescence of DNS-CaM and tryptic digestion of native CaM in the absence of Ca2+. Enhancement of DNS fluorescence of DNS-CaM by CaMBP was observed only in the presence of Ca2+ and lyso-PC could further increase the fluorescence intensity of the complex. These all results suggest that lyso-PC can modulate the interaction between CaM and CaMBP as a result of its direct effect on conformation of CaM.


Asunto(s)
Química Encefálica , Proteínas de Unión a Calmodulina/metabolismo , Calmodulina/metabolismo , Metabolismo de los Lípidos , Lisofosfatidilcolinas/farmacología , Animales , Calmodulina/química , Bovinos , Compuestos de Dansilo , Colorantes Fluorescentes , Conformación Proteica/efectos de los fármacos , Espectrometría de Fluorescencia , Tripsina/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...