Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Blood Press Monit ; 26(5): 393-395, 2021 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-34001760

RESUMEN

OBJECTIVE: we assessed the accuracy of the QMon-20 oscillometric upper-arm cuff device professional for office blood pressure (BP) in general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Universal Standard (ISO 81060-2:2018). METHODS: Subjects were recruited according to AAMI/ESH/ISO Universal Standard in general population using the same arm sequential BP measurement method. Two cuffs of the test device were used for arm circumference 22-31 (medium) and 32-42 cm (large). RESULTS: One-hundred and fourteen subjects were recruited and 106 were analyzed. For validation criterion 1, the mean ± SD of the differences between the test device and reference BP readings was 0.8 ± 5.4/-0.5 ± 4.2 mmHg (systolic/diastolic). For criterion 2, the SD of the mean BP differences between the test device and reference BP per subject was 4.34/3.48 mmHg (systolic/diastolic). CONCLUSION: The QMon-20 oscillometric device for office BPs measurement fulfilled all the requirements of the AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018) in general population and can be recommended for clinical use.


Asunto(s)
Monitores de Presión Sanguínea , Hipertensión , Presión Sanguínea , Determinación de la Presión Sanguínea , Humanos , Hipertensión/diagnóstico , Sístole
2.
Int Urol Nephrol ; 52(12): 2367-2377, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32671667

RESUMEN

BACKGROUND: The incidence of acute kidney injury requiring dialysis (AKI-D) is increasing globally and it is usually associated to chronic kidney disease (CKD) and high mortality. Literature is lacking in short- and intermediate-term data on recovery of renal function after acute kidney injury (AKI). OBJECTIVES: The objective was to evaluate the overall survival and renal recovery after an episode of AKI requiring dialysis out of intensive care units (ICUs). MATERIALS AND METHODS: Retrospective study including patients admitted in two nephrology units along a period of 2 years. Patients admitted to ICUs and renal transplant patients were excluded. Baseline renal function, mortality and glomerular filtration rate (GFR) improvement were evaluated. RESULTS: 151 consecutive adult patients with AKI requiring renal replacement therapy (RRT) were included. Mean age was 70.5 ± 15.2 years, 60.3% were males. Median baseline creatinine (bCr) and baseline GFR (bGFR) were 1.4 mg/dL and 46 mL/min/1.73 m2, respectively. After 1 year of follow-up, we completed the monitoring of 94 patients: 64.9% had died, 10.6% were alive on dialysis and 24.5% were alive without need for RRT. Patients with bGFR > 60 mL/min/1.73 m2 prior to AKI episode had a slower but sustained GFR improvement through the follow-up in comparison with patients with bGFR < 60 mL/min/1.73 m2 whose recovery was incomplete. CONCLUSIONS: Patients with AKI requiring RRT have high short- and intermediate-term mortality and some require maintenance dialysis. Patients with GFR > 60 mL/min/1.73 m2 prior to AKI had a renal recovery closer to the basal renal function than in patients with a previously diminished GFR.


Asunto(s)
Lesión Renal Aguda/mortalidad , Lesión Renal Aguda/terapia , Diálisis Renal , Anciano , Anciano de 80 o más Años , Femenino , Tasa de Filtración Glomerular , Humanos , Unidades de Cuidados Intensivos , Riñón/fisiología , Masculino , Persona de Mediana Edad , Recuperación de la Función , Estudios Retrospectivos , Tasa de Supervivencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...