Purpose: This R-Ideal stage 1b/2a study describes the workflow and feasibility of long-course fractionated online adaptive MR-guided chemoradiotherapy with reduced CTV-to-PTV margins on the 1.5T MR-Linac for patients with esophageal cancer. Methods: Patients with esophageal cancer scheduled to undergo chemoradiation were treated on a 1.5T MR-Linac. Daily MR-images were acquired for online contour adaptation and replanning. Contours were manually adapted to match the daily anatomy and an isotropic CTV-to-PTV margin of 6 mm was applied. Time was recorded for all individual steps in the workflow. Feasibility and patient tolerability were defined as on-table time of ≤60 min and completion of >95% of the fractions on the MR-Linac, respectively. Positioning verification and post-treatment MRIs were retrospectively analyzed and dosimetric parameters were compared to standard non-adaptive conventional treatment plans. Results: Nine patients with esophageal cancer were treated with chemoradiation; eight patients received 41.4 Gy in 23 fractions and one received 50.4 Gy in 28 fractions. Four patients received all planned fractions on the MR-Linac, whereas for two patients >5% of fractions were rescheduled to a conventional linac for reasons of discomfort. A total of 183 (86%) of 212 scheduled fractions were successfully delivered on the MR-Linac. Three fractions ended prematurely due to technical issues and 26 fractions were rescheduled on a conventional linac due to MR-Linac downtime (n = 10), logistical reasons (n = 3) or discomfort (n = 13).The median time per fraction was 53 min (IQR = 3 min). Daily adapted MR-Linac plans had similar target coverage, whereas dose to the organs-at-risk was significantly reduced compared to conventional treatment (26% and 12% reduction in mean lung and heart dose, respectively). Conclusion: Daily online adaptive fractionated chemoradiotherapy with reduced PTV margins is moderately feasible for esophageal cancer and results in better sparing of heart and lungs. Future studies should focus on further optimization and acceleration of the current workflow.
RESUMEN
PURPOSE: To evaluate seminal vesicle (SV) intrafraction motion using cinematic magnetic resonance imaging (cine-MR) during the delivery of online adaptive MR-Linac radiotherapy fractions, in preparation of MR-guided extremely hypofractionated radiotherapy for intermediate to high-risk prostate cancer patients. MATERIAL AND METHODS: Fifty prostate cancer patients were treated with 5 × 7.25 Gy on a 1.5 Tesla MR-Linac. 3D Cine-MR imaging was started simultaneously and acquired over the full beam-on period. Intrafraction motion in this cine-MR was determined for each SV separately with a previously validated soft-tissue contrast-based tracking algorithm. Motion statistics and coverage probability for the SVs and prostate were determined based on the obtained results. RESULTS: SV motion was automatically determined during the beam-on period (approx. 10 min) for 247 fractions. SV intrafraction motion shows larger spread than prostate intrafraction motion and increases over time. This difference is especially evident in the anterior and cranial translation directions. Significant difference in rotation about the left-right axis was found, with larger rotation for the SVs than the prostate. Intra-fraction coverage probability of 99% can be achieved when using 5 mm isometric expansion for the left and right SV and 3 mm for the prostate. CONCLUSION: This is the first study to investigate SV intrafraction motion during MR-guided RT sessions on an MR-Linac. We have shown that high quality 3D cine-MR imaging and SV tracking during RT is feasible with beam-on. The tracking method as described may be used as input for a fast replanning algorithm, which allows for intrafraction plan adaptation.
Asunto(s)
Neoplasias de la Próstata , Radiocirugia , Radioterapia Guiada por Imagen , Radioterapia de Intensidad Modulada , Humanos , Imagen por Resonancia Magnética , Masculino , Movimiento , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador , Rotación , Vesículas Seminales/diagnóstico por imagenRESUMEN
Purpose. The Utrecht single needle implant device (SNID) was redesigned to increase needle insertion velocity. The purpose of this study is to evaluate the magnetic resonance compatibility, safety and accuracy of the implant device preparing its application in a patient study to investigate the feasibility of inserting a brachytherapy needle into the prostate to a defined tumor target point.Methods. Several experiments were performed to evaluate the mechanical and radiofrequency safety of the needle system, the magnetic field perturbation, the calibration of the implant device in the MR coordinate system, functioning of the implant device during imaging and accuracy of needle insertion.Results. Endurance experiments showed the mechanical safety of the needle system. Magnetic field perturbation was acceptable with induced image distortions smaller than 0.5 mm for clinical MR sequences. Calibration of the implant device in the MR coordinate system was reproducible with average error (mean±standard deviation) of 0.2 ± 0.4 mm, 0.1 ± 0.3 mm and 0.6 ± 0.6 mm in thex,y- andz- direction, respectively. The RF safety measurement showed for clinical MR imaging sequences maximum temperature rises of 0.2 °C at the entry and tip points of the needle. Simultaneous functioning of the implant device and imaging is possible albeit with some intensity band artifacts in the fast field echo images. Finally, phantom measurements showed deviations amounting 2.5-3.6 mm measured as target-to-needle distance at a depth of 12 cm.Conclusions. This preclinical evaluation showed that the MR compatibility, safety and accuracy of the redesigned UMC Utrecht SNID allow its application in a patient study on the feasibility of inserting a brachytherapy needle into the prostate to a defined tumor target point.
Asunto(s)
Braquiterapia , Neoplasias de la Próstata , Artefactos , Braquiterapia/efectos adversos , Humanos , Imagen por Resonancia Magnética , Masculino , Agujas , Fantasmas de Imagen , Próstata/diagnóstico por imagen , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapiaRESUMEN
PURPOSE: This study aimed to assess the smallest clinical target volume (CTV) to planned target volume (PTV) margins for esophageal cancer radiotherapy using daily online registration to the bony anatomy that yield full dosimetric coverage over the course of treatment. METHODS: 29 esophageal cancer patients underwent six T2-weighted MRI scans at weekly intervals. An online bone-match image-guided radiotherapy treatment of five fractions was simulated for each patient. Multiple conformal treatment plans with increasing margins around the CTV were created for each patient. Then, the dose was warped to obtain an accumulated dose per simulated fraction. Full target coverage by 95% of the prescribed dose was assessed as a function of margin expansion in six directions. If target coverage in a single direction was accomplished, then the respective margin remained fixed for the subsequent dose plans. Margins in uncovered directions were increased in a new dose plan until full target coverage was achieved. RESULTS: The smallest set of CTV-to-PTV margins that yielded full dosimetric CTV coverage was 8 mm in posterior and right direction, 9 mm in anterior and cranial direction and 10 mm in left and caudal direction for 27 out of 29 patients. In two patients the curvature of the esophagus considerably changed between fractions, which required a 17 and 23 mm margin in right direction. CONCLUSION: Accumulated dose analysis revealed that CTV-to-PTV treatment margins of 8, 9 and 10 mm in posterior & right, anterior & cranial and left & caudal direction, respectively, are sufficient to account for interfraction tumor variations over the course of treatment when applying a daily online bone match. However, two patients with extreme esophageal interfraction motion were insufficiently covered with these margins and were identified as patients requiring replanning to achieve full target coverage.
Asunto(s)
Neoplasias Esofágicas , Neoplasias de la Próstata , Radioterapia Guiada por Imagen , Radioterapia de Intensidad Modulada , Neoplasias Esofágicas/radioterapia , Humanos , Masculino , Radiometría , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por ComputadorRESUMEN
In this work we present the first delivery of intensity modulated arc therapy on the Elekta Unity 1.5 T MR-linac. The machine's current intensity modulated radiation therapy based control system was modified suitably to enable dynamic delivery of radiation, for the purpose of exploring MRI-guided radiation therapy adaptation modes in a research setting. The proof-of-concept feasibility was demonstrated by planning and delivering two types of plans, each investigating the performance of different parts of a dynamic treatment. A series of fixed-speed arc plans was used to show the high-speed capabilities of the gantry during radiation, while several fully modulated prostate plans-optimised following the volumetric modulated arc therapy approach-were delivered in order to establish the performance of its multi-leaf collimator and diaphragms. These plans were delivered to Delta4 Phantom+ MR and film phantoms passing the clinical quality assurance criteria used in our clinic. In addition, we also performed some initial MR imaging experiments during dynamic therapy, demonstrating that the impact of radiation and moving gantry/collimator components on the image quality is negligible. These results show that arc therapy is feasible on the Elekta Unity system. The machine's high performance components enable dynamic delivery during fast gantry rotation and can be controlled in a stable fashion to deliver fully modulated plans.
Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Aceleradores de Partículas , Radioterapia de Intensidad Modulada/instrumentación , Humanos , Masculino , Fantasmas de Imagen , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , RotaciónRESUMEN
Hybrid MRI-linac (MRL) systems enable daily multiparametric quantitative MRI to assess tumor response to radiotherapy. Magnetic resonance fingerprinting (MRF) may provide time efficient means of rapid multiparametric quantitative MRI. The accuracy of MRF, however, relies on adequate control over system imperfections, such as eddy currents and [Formula: see text], which are different and not as well established on MRL systems compared to diagnostic systems. In this study we investigate the technical feasibility of gradient spoiled 2D MRF on a 1.5T MRL. We show with phantom experiments that the MRL generates reliable MRF signals that are temporally stable during the day and have good agreement with spin-echo reference measurements. Subsequent in-vivo MRF scans in healthy volunteers and a patient with a colorectal liver metastasis showed good image quality, where the quantitative values of selected organs corresponded with the values reported in literature. Therefore we conclude that gradient spoiled 2D MRF is feasible on a 1.5T MRL with similar performance as on a diagnostic system. The precision and accuracy of the parametric maps are sufficient for further investigation of the clinical utility of MRF for online quantitatively MRI-guided radiotherapy.
Asunto(s)
Encéfalo/anatomía & histología , Neoplasias Colorrectales/patología , Procesamiento de Imagen Asistido por Computador/métodos , Neoplasias Hepáticas/secundario , Imágenes de Resonancia Magnética Multiparamétrica/métodos , Fantasmas de Imagen , Estudios de Factibilidad , Voluntarios Sanos , Humanos , Reproducibilidad de los ResultadosRESUMEN
PURPOSE: To evaluate prostate intrafraction motion using MRI during the full course of online adaptive MR-Linac radiotherapy (RT) fractions, in preparation of MR-guided extremely hypofractionated RT. MATERIAL AND METHODS: Five low and intermediate risk prostate cancer patients were treated with 20 × 3.1 Gy fractions on a 1.5T MR-Linac. Each fraction, initial MRI (Pre) scans were obtained at the start of every treatment session. Pre-treatment planning MRI contours were propagated and adapted to this Pre scan after which plan re-optimization was started in the treatment planning system followed by dose delivery. 3D Cine-MR imaging was started simultaneously with beam-on and acquired over the full beam-on period. Prostate intrafraction motion in this cine-MR was determined with a previously validated soft-tissue contrast based tracking algorithm. In addition, absolute accuracy of the method was determined using a 4D phantom. RESULTS: Prostate motion was completely automatically determined over the full on-couch period (approx. 45 min) with no identified mis-registrations. The translation 95% confidence intervals are within clinically applied margins of 5 mm, and plan adaption for intrafraction motion was required in only 4 out of 100 fractions. CONCLUSION: This is the first study to investigate prostate intrafraction motions during entire MR-guided RT sessions on an MR-Linac. We have shown that high quality 3D cine-MR imaging and prostate tracking during RT is feasible with beam-on. The clinically applied margins of 5 mm have proven to be sufficient for these treatments and may potentially be further reduced using intrafraction plan adaptation guided by cine-MR imaging.
Asunto(s)
Neoplasias de la Próstata , Planificación de la Radioterapia Asistida por Computador , Humanos , Imagen por Resonancia Magnética , Masculino , Movimiento , Aceleradores de Partículas , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapiaRESUMEN
Motion is problematic during radiotherapy as it could lead to potential underdosage of the tumor, and/or overdosage in organs-at-risk. A solution is adaptive radiotherapy guided by magnetic resonance imaging (MRI). MRI allows for imaging of target volumes and organs-at-risk before and during treatment delivery with superb soft tissue contrast in any desired orientation, enabling motion management by means of (real-time) adaptive radiotherapy. The noise navigator, which is independent of the MR signal, could serve as a secondary motion detection method in synergy with MR imaging. The feasibility of respiratory motion detection by means of the noise navigator was demonstrated previously. Furthermore, from electromagnetic simulations we know that the noise navigator is sensitive to tissue displacement and thus could in principle be used for the detection of various types of motion. In this study we demonstrate the detection of various types of motion for three anatomical use cases of MRI-guided radiotherapy, i.e. torso (bulk movement and variable breathing), head-and-neck (swallowing) and cardiac. Furthermore, it is shown that the noise navigator can detect bulk movement, variable breathing and swallowing on a hybrid 1.5 T MRI-linac system. Cardiac activity detection through the noise navigator seems feasible in an MRI-guided radiotherapy setting, but needs further optimization. The noise navigator is a versatile and fast (millisecond temporal resolution) motion detection method independent of MR signal that could serve as an independent verification method to detect the occurrence of motion in synergy with real-time MRI-guided radiotherapy.
Asunto(s)
Imagen por Resonancia Magnética , Movimientos de los Órganos , Radioterapia Guiada por Imagen/métodos , Humanos , Órganos en Riesgo/efectos de la radiación , Aceleradores de Partículas , Radioterapia Guiada por Imagen/efectos adversos , Relación Señal-RuidoRESUMEN
PURPOSE: This study aimed to quantify the coverage probability for esophageal cancer radiotherapy as a function of a preset margin for online MR-guided and (CB)CT-guided radiotherapy. METHODS: Thirty esophageal cancer patients underwent six T2-weighted MRI scans, 1 prior to treatment and 5 during neoadjuvant chemoradiotherapy at weekly intervals. Gross tumor volume (GTV) and clinical target volume (CTV) were delineated on each individual scan. Follow-up scans were rigidly aligned to the bony anatomy and to the clinical target volume itself, mimicking two online set-up correction strategies: a conventional CBCT-guided set-up and a MR-guided set-up, respectively. Geometric coverage probability of the propagated CTVs was assessed for both set-up strategies by expanding the reference CTV with an isotropic margin varying from 0 mm to 15 mm with an increment of 1 mm. RESULTS: A margin of 10 mm could resolve the interfractional changes for 118 out of the 132 (89%) analyzed fractions when applying a bone-match registration, whereas the CTV was adequately covered in 123 (93%) fractions when the registration was directly performed at the CTV itself (soft-tissue registration). Closer analyses revealed that target coverage violation predominantly occurred for distal tumors near the junction and into the cardia. CONCLUSION: Online MR-guided soft-tissue registration protocols exhibited modest improvements of the geometric target coverage probability as compared to online CBCT-guided bone match protocols. Therefore, highly conformal target irradiation using online MR-guidance can only be achieved by implementing on-table adaptive workflows where new treatment plans are daily generated based on the anatomy of the day.
Asunto(s)
Neoplasias Esofágicas , Radioterapia Conformacional , Radioterapia Guiada por Imagen , Radioterapia de Intensidad Modulada , Neoplasias Esofágicas/diagnóstico por imagen , Neoplasias Esofágicas/radioterapia , Humanos , Imagen por Resonancia Magnética , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por ComputadorRESUMEN
We present DeepDose, a deep learning framework for fast dose calculations in radiation therapy. Given a patient anatomy and linear-accelerator IMRT multi-leaf-collimator shape or segment, a novel set of physics-based inputs is calculated that encode the linac machine parameters into the underlying anatomy. These inputs are then used to train a deep convolutional network to derive the dose distribution of individual MLC shapes on a given patient anatomy. In this work we demonstrate the proof-of-concept application of DeepDose on 101 prostate patients treated in our clinic with fixed-beam IMRT. The ground-truth data used for training, validation and testing of the prediction were calculated with a state-of-the-art Monte Carlo dose engine at 1% statistical uncertainty per segment. A deep convolution network was trained using the data of 80 patients at the clinically used 3 mm3 grid spacing while 10 patients were used for validation. For another 11 independent test patients, the network was able to accurately estimate the segment doses from the clinical plans of each patient passing the clinical QA when compared with the Monte Carlo calculations, yielding on average 99.9%±0.3% for the forward calculated patient plans at 3%/3 mm gamma tests. Dose prediction using the trained network was very fast at approximately 0.9 seconds for the input generation and 0.6 seconds for single GPU inference per segment and 1 minute per patient in total. The overall performance of this dose calculation framework in terms of both accuracy and inference speed, makes it compelling for online adaptive workflows where fast segment dose calculations are needed.
Asunto(s)
Aprendizaje Profundo , Dosis de Radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada , Algoritmos , Humanos , Masculino , Método de Montecarlo , Aceleradores de Partículas , Neoplasias de la Próstata/radioterapia , Dosificación RadioterapéuticaRESUMEN
To investigate the dosimetric impact of intrafraction translation and rotation motion of the prostate, as extracted from daily acquired post-treatment 3D cine-MR based on soft-tissue contrast, in extremely hypofractionated (SBRT) prostate patients. Accurate dose reconstruction is performed by using a prostate intrafraction motion trace which is obtained with a soft-tissue based rigid registration method on 3D cine-MR dynamics with a temporal resolution of 11 s. The recorded motion of each time-point was applied to the planning CT, resulting in the respective dynamic volume used for dose calculation. For each treatment fraction, the treatment delivery record was generated by proportionally splitting the plan into 11 s intervals based on the delivered monitor units. For each fraction the doses of all partial plan/dynamic volume combinations were calculated and were summed to lead to the motion-affected fraction dose. Finally, for each patient the five fraction doses were summed, yielding the total treatment dose. Both daily and total doses were compared to the original reference dose of the respective patient to assess the impact of the intrafraction motion. Depending on the underlying motion of the prostate, different types of motion-affected dose distributions were observed. The planning target volumes (PTVs) ensured CTV_30 (seminal vesicles) D99% coverage for all patients, CTV_35 (prostate corpus) coverage for 97% of the patients and GTV_50 (local boost) for 83% of the patients when compared against the strict planning target D99% value. The dosimetric impact due to prostate intrafraction motion in extremely hypofractionated treatments was determined. The presented study is an essential step towards establishing the actual delivered dose to the patient during radiotherapy fractions.
Asunto(s)
Fraccionamiento de la Dosis de Radiación , Imagenología Tridimensional , Movimiento , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Radiocirugia/métodos , Algoritmos , Humanos , Masculino , Radiometría , Planificación de la Radioterapia Asistida por Computador , RotaciónRESUMEN
Respiratory-correlated 4D-MRI can characterize respiratory-induced motion of tumors and organs-at-risk for radiotherapy treatment planning and is a necessity for image guidance of moving tumors treated on an MRI-linac. Essential for 4D-MRI generation is a robust respiratory surrogate signal. We investigated the feasibility of the noise navigator as respiratory surrogate signal for 4D-MRI generation. The noise navigator is based on the respiratory-induced modulation of the thermal noise variance measured by the receive coils during MR acquisition and thus is inherently present and synchronized with MRI data acquisition. Additionally, the noise navigator can be combined with any rectilinear readout strategy (e.g. radial and cartesian) and is independent of MR image contrast and imaging orientation. For radiotherapy applications, the noise navigator provides a robust respiratory signal for patients scanned with an elevated coil setup. This is particularly attractive for widely used cartesian sequences where currently a non-interfering self-navigation means is lacking for MRI-based simulation and MRI-guided radiotherapy. The feasibility of 4D-MRI generation with the noise navigator as respiratory surrogate signal was demonstrated for both cartesian and radial readout strategies in radiotherapy setup on four healthy volunteers and two radiotherapy patients on a dedicated 1.5 T MRI scanner and two radiotherapy patients on a 1.5 T MRI-linac system. Moreover, the respiratory-correlated 4D-MR images showed liver motion comparable to a reference 2D cine MRI series for the volunteers. For 2D cartesian cine MRI acquisitions, both the noise navigator and respiratory bellows were benchmarked against an image navigator. Respiratory phase detection based on the noise navigator agreed 1.4 times better with the image navigator than the respiratory bellows did. For a 3D Stack-of-Stars acquisitions, the noise navigator was compared to radial self-navigation and a 1.7 times higher respiratory phase detection agreement was observed than for the respiratory bellows compared to radial self-navigation.
Asunto(s)
Hígado/efectos de la radiación , Neoplasias Pulmonares/patología , Imagen por Resonancia Magnética/métodos , Órganos en Riesgo/efectos de la radiación , Neoplasias Pancreáticas/patología , Respiración , Técnicas de Imagen Sincronizada Respiratorias/métodos , Relación Señal-Ruido , Voluntarios Sanos , Humanos , Imagenología Tridimensional/métodos , Neoplasias Pulmonares/radioterapia , Movimiento , Neoplasias Pancreáticas/radioterapia , Aceleradores de PartículasRESUMEN
To develop a method to automatically determine intrafraction motion of the prostate based on soft tissue contrast on 3D cine-magnetic resonance (MR) images with high spatial and temporal resolution. Twenty-nine patients who underwent prostate stereotactic body radiotherapy (SBRT), with four implanted cylindrical gold fiducial markers (FMs), had cine-MR imaging sessions after each of five weekly fractions. Each cine-MR session consisted of 55 sequentially obtained 3D data sets ('dynamics') and was acquired over an 11 s period, covering a total of 10 min. The prostate was delineated on the first dynamic of every dataset and this delineation was used as the starting position for the soft tissue tracking (SST). Each subsequent dynamic was rigidly aligned to the first dynamic, based on the contrast of the prostate. The obtained translation and rotation describes the intrafraction motion of the prostate. The algorithm was applied to 6270 dynamics over 114 scans of 29 patients and the results were validated by comparing to previously obtained fiducial marker tracking data of the same dataset. Our proposed tracking method was also retro-perspectively applied to cine-MR images acquired during MR-guided radiotherapy of our first prostate patient treated on the MR-Linac. The difference in the 3D translation results between the soft tissue and marker tracking was below 1 mm for 98.2% of the time. The mean translation at 10 min were X: 0.0 [Formula: see text] 0.8 mm, Y: 1.0 [Formula: see text] 1.8 mm and Z: [Formula: see text] mm. The mean rotation results at 10 min were X: [Formula: see text], Y: 0.1 [Formula: see text] 0.6° and Z: 0.0 [Formula: see text] 0.7°. A fast, robust and accurate SST algorithm was developed which obviates the need for FMs during MR-guided prostate radiotherapy. To our knowledge, this is the first data using full 3D cine-MR images for real-time soft tissue prostate tracking, which is validated against previously obtained marker tracking data.
Asunto(s)
Imagenología Tridimensional/métodos , Imagen por Resonancia Cinemagnética/métodos , Neoplasias de la Próstata/radioterapia , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Guiada por Imagen/métodos , Algoritmos , Marcadores Fiduciales , Humanos , Imagenología Tridimensional/normas , Imagen por Resonancia Cinemagnética/normas , Masculino , Movimiento , Próstata/diagnóstico por imagen , Neoplasias de la Próstata/diagnóstico por imagen , Radiocirugia/normas , Planificación de la Radioterapia Asistida por Computador/normas , Radioterapia Guiada por Imagen/normas , RotaciónRESUMEN
PURPOSE: The noise navigator is a passive way to detect physiological motion occurring in a patient through thermal noise modulations measured by standard clinical radiofrequency receive coils. The aim is to gain a deeper understanding of the potential and applications of physiologically induced thermal noise modulations. METHODS: Numerical electromagnetic simulations and MR measurements were performed to investigate the relative contribution of tissue displacement versus modulation of the dielectric lung properties over the respiratory cycle, the impact of coil diameter and position with respect to the body. Furthermore, the spatial motion sensitivity of specific noise covariance matrix elements of a receive array was investigated. RESULTS: The influence of dielectric lung property variations on the noise variance is negligible compared to tissue displacement. Coil size affected the thermal noise variance modulation, but the location of the coil with respect to the body had a larger impact. The modulation depth of a 15 cm diameter stationary coil approximately 3 cm away from the chest (i.e. radiotherapy setup) was 39.7% compared to 4.2% for a coil of the same size on the chest, moving along with respiratory motion. A combination of particular noise covariance matrix elements creates a specific spatial sensitivity for motion. CONCLUSIONS: The insight gained on the physical relations governing the noise navigator will allow for optimized use and development of new applications. An optimized combination of elements from the noise covariance matrix offer new ways of performing, e.g. motion tracking.
Asunto(s)
Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética , Movimiento (Física) , Simulación por Computador , Radiación Electromagnética , Voluntarios Sanos , Humanos , Masculino , Músculos/diagnóstico por imagen , Fantasmas de Imagen , Ondas de Radio , Radioterapia , Relación Señal-Ruido , Piel/diagnóstico por imagenRESUMEN
Recently, multileaf collimator (MLC)-tracking has been technically and clinically demonstrated showing promising improvements of radiotherapy of mobile sites. Furthermore, magnetic resonance imaging (MRI)-guided treatments have shown to provide superior targetting performance due to on-line soft-tissue imaging. Hitherto, the combination of MLC-tracking and MRI has not been investigated using clinically released hardware. In this note we aim to describe the technical feasibilty of such a combination on a clinically operating MRI-linac. The MLC-tracking system is characterized by quantifying the latencies and geometric errors produced by the system. In order to reach optimization recommendations, the tracking system was first characterized using a quasi-ideal position sensor, isolating the performance of the MLC only. Subsequently, the analysis was repeated using real-time MRI as the positioning source for the MLC. For the isolated MLC, we found latencies of 20.67 ms and minimal overshooting behaviour. The latencies for MRI-guidance were 347.45 ms at 4 Hz imaging and 204 ms at 8 Hz. We showed that MLC-tracking on the Elekta Unity using integrated MRI is technically supported and feasible. The isolated analysis of the MLC demonstrated the negligible contribution of the MLC in MRI-guided tracking. The latency and geometric errors caused by the sampling properties of MRI exceed the MLC-related errors by several factors. Most gain for real-time MRI-based adaptive radiotherapy can therefore be realized by optimizing and accelerating the MRI acquisition process.
Asunto(s)
Imagen por Resonancia Magnética/métodos , Aceleradores de Partículas/normas , Radioterapia de Intensidad Modulada/métodos , Humanos , Radioterapia de Intensidad Modulada/instrumentaciónRESUMEN
PURPOSE: Reference dosimetry in a strong magnetic field is made more complex due to (a) the change in dose deposition and (b) the change in sensitivity of the detector. Potentially it is also influenced by thin air layers, interfaces between media, relative orientations of field, chamber and radiation, and minor variations in ion chamber stem or electrode construction. The PTW30013 and IBA FC65-G detectors are waterproof Farmer-type ion chambers that are suitable for reference dosimetry. The magnetic field correction factors have previously been determined for these chamber types. The aim of this study was to assess the chamber-to-chamber variation and determine whether generic chamber type-specific magnetic field correction factors can be applied for each of the PTW30013 and FC65-G type ion chambers when they are oriented anti-parallel (Ç) to, or perpendicular (â¥) to, the magnetic field. METHODS: The experiment was conducted with 12 PTW30013 and 13 FC65-G chambers. The magnetic field correction factors were measured using a practical method. In this study each chamber was cross-calibrated against the local standard chamber twice; with and without magnetic field. Measurements with 1.5 T magnetic field were performed with the 7 MV FFF beam of the MRI-linac. Measurements without magnetic field (0 T) were performed with the 6 MV conventional beam of an Elekta Agility linac. A prototype MR-compatible PTW MP1 phantom was used along with a prototype holder that facilitated measurements with the chamber aligned 90° counter-clockwise (â¥) and 180° (Ç) to the direction of the magnetic field. A monitor chamber was also mounted on the holder and all measurements were normalized so that the effect of variations in the output of each linac was minimized. Measurements with the local standard chamber were repeated during the experiment to quantify the experimental uncertainty. Recombination was measured in the 6 MV beam. Beam quality correction factors were applied. Differences in recombination and beam quality between beams are constant within each chamber type. By comparing the results for the two cross calibrations the magnetic field correction factors can be determined for each chamber, and the variation within the chamber-type determined. RESULTS: The magnetic field correction factors within both PTW30013 and FC65-G chamber-types were found to be very consistent, with observed standard deviations for the PTW30013 of 0.19% (Ç) and 0.13% (â¥), and for the FC65-G of 0.15% (Ç) and 0.17% (â¥). These variations are comparable with the standard uncertainty (k = 1) of 0.24%. CONCLUSION: The consistency of the results for the PTW30013 and FC65-G chambers implies that it is not necessary to derive a new factor for every new PTW30013 or FC65-G chamber. Values for each chamber-type (with careful attention to beam energy, magnetic field strength and beam-field-chamber orientations) can be applied from the literature.
Asunto(s)
Campos Magnéticos , Radiometría/instrumentación , Calibración , Aceleradores de Partículas , Fantasmas de ImagenRESUMEN
OBJECTIVE: To develop a novel radio-frequency (RF) concept for ultra-high field (UHF) human magnetic resonance imaging (MRI) based on a coaxial resonant cavity. METHODS: A two-channel slotted coaxial cavity RF applicator was designed for human head MRI at 9.4T. Physical dimensions made the proposed conducting structure resonant at the required frequency without tuning lumped elements. Numerical electromagnetic modeling was used to optimize the design. RF safety was assessed with two representative human body models. MR experiments on a 9.4T scanner included gradient echo images and mapping of a circularly polarized RF magnetic field in the human head phantom. RESULTS: The simulations and the phantom MR experiments agreed both qualitatively and quantitatively. The design was relatively simple, robust and required only a few additional reactive elements for the applicator's input impedance matching. The transmit efficiency and homogeneity of the excitation field were only 20% and 4% lower compared to a conventional 8-channel head array. CONCLUSION: The coaxial RF applicator was feasible for human MRI at UHF and required no lumped elements for its tuning. Imaging performance of the RF applicator was only moderately lower compared to the conventional transmit array, but would be sufficient to provide an anatomical reference for the heteronuclei MRI. SIGNIFICANCE: An alternative approach with the minimal involvement of lumped elements becomes feasible to design volume-type RF coils for UHF human MRI.
Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Diseño de Equipo , Seguridad de Equipos , Cabeza , Humanos , Fantasmas de Imagen , Ondas de RadioRESUMEN
PURPOSE/OBJECTIVE: Flank irradiation for Wilms' tumor (WT) is currently performed at our institute using a cone-beam computed tomography-guided volumetric modulated arc (VMATCBCT) workflow. By adding real-time magnetic resonance imaging (MRI) guidance to the treatment, safety margins could be reduced. The study purpose was to quantify the potential reduction of the planning target volume (PTV) margin and its dosimetric impact when using an MRI-guided intensity modulated radiation therapy (IMRTMRI) workflow compared to the VMATCBCT workflow. MATERIAL/METHODS: 4D-CT, MRI and CBCT scans acquired during preparation and treatment of 15 patients, were used to estimate both geometric, motion and patient set-up systematic (∑) and random (σ) errors for VMATCBCT and IMRTMRI workflows. The mean PTV (PTVmean) expansion was calculated using the van Herk formula. Treatment plans were generated using five margin scenarios (PTVmean ± 0, 1 and 2 mm). Furthermore, the IMRTMRI plans were optimized with a 1.5T transverse magnetic field turned-on to realistically model an MRI-guided treatment. Plans were evaluated using dose-volume statistics (p<.01, Wilcoxon). RESULTS: Analysis of ∑ and σ errors resulted in a PTVmean of 5 mm for the VMATCBCT and 3 mm for the IMRTMRI workflows in each orthogonal direction. Target coverage was unaffected by the margin decrease with a mean V95%=100% for all margin scenarios. For the PTVmean, an average reduction of the mean dose to the organs at risk (OARs) was achieved with IMRTMRI compared to VMATCBCT: 3.4 ± 2.4% (p<.01) for the kidney, 3.4 ± 2.1% (p<.01) for the liver, 2.8 ± 3.0% (p<.01) for the spleen and 4.9 ± 3.8% (p<.01) for the pancreas, respectively. CONCLUSIONS: Imaging data in children with WT demonstrated that the PTV margin could be reduced isotropically down to 2 mm when using the IMRTMRI compared to the VMATCBCT workflow. The former results in a dose reduction to the OARs while maintaining target coverage.
Asunto(s)
Neoplasias Renales/radioterapia , Imagen por Resonancia Magnética , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Guiada por Imagen/métodos , Radioterapia de Intensidad Modulada/métodos , Tumor de Wilms/radioterapia , Niño , Preescolar , Terapia Combinada , Tomografía Computarizada de Haz Cónico , Fraccionamiento de la Dosis de Radiación , Femenino , Tomografía Computarizada Cuatridimensional , Humanos , Lactante , Neoplasias Renales/tratamiento farmacológico , Neoplasias Renales/patología , Neoplasias Renales/cirugía , Masculino , Órganos en Riesgo , Estudios Retrospectivos , Tumor de Wilms/tratamiento farmacológico , Tumor de Wilms/patología , Tumor de Wilms/cirugíaRESUMEN
The transverse magnetic field of an MRI-linac sweeps contaminant electrons away from the radiation beam. Films oriented perpendicular to the magnetic field and 5 cm from the radiation beam edge show a projection of the divergent beam, indicating that contaminant electrons spiral along magnetic field lines and deposit dose on surfaces outside the primary beam perpendicular to the magnetic field. These spiraling contaminant electrons (SCE) could increase skin doses to protruding regions of the patient along the cranio-caudal axis. This study investigated doses from SCE for an MRI-linac comprising a 7 MV linac and a 1.5 T MRI scanner. Surface doses to films perpendicular to the magnetic field and 5 cm from the radiation beam edge showed increased dose within the projection of the primary beam, whereas films parallel to the magnetic field and 5 cm from the beam edge showed no region of increased dose. However, the dose from contaminant electrons is absorbed within a few millimeters. For large fields, the SCE dose is within the same order of magnitude as doses from scattered and leakage photons. Doses for both SCE and scattered photons decrease rapidly with decreasing beam size and increasing distance from the beam edge.
Asunto(s)
Electrones , Campos Magnéticos , Imagen por Resonancia Magnética/métodos , Fotones , Piel/efectos de la radiación , Humanos , Aceleradores de PartículasRESUMEN
As a prerequisite for clinical treatments it was necessary to characterize the Elekta 1.5 T MRI-linac 7 MV FFF radiation beam. Following acceptance testing, beam characterization data were acquired with Semiflex 3D (PTW 31021), microDiamond (PTW 60019), and Farmer-type (PTW 30013 and IBA FC65-G) detectors in an Elekta 3D scanning water phantom and a PTW 1D water phantom. EBT3 Gafchromic film and ion chamber measurements in a buildup cap were also used. Special consideration was given to scan offsets, detector effective points of measurement and avoiding air gaps. Machine performance has been verified and the system satisfied the relevant beam requirements of IEC60976. Beam data were acquired for field sizes between 1 × 1 and 57 × 22 cm2. New techniques were developed to measure percentage depth dose (PDD) curves including the electron return effect at beam exit, which exhibits an electron-type practical range of 1.2 ± 0.1 cm. The Lorentz force acting on the secondary charged particles creates an asymmetry in the crossline profiles with an average shift of +0.24 cm. For a 10 × 10 cm2 beam, scatter from the cryostat contributes 1% of the dose at isocentre. This affects the relative output factors, scatter factors and beam profiles, both in-field and out-of-field. The average 20%-80% penumbral width measured for small fields with a microDiamond detector at 10 cm depth is 0.50 cm. MRI-linac penumbral widths are very similar to that of the Elekta Agility linac MLC, as is the near-surface dose PDD(0.2 cm) = 57%. The entrance surface dose is â¼36% of Dmax. Cryostat transmission is quantified for inclusion within the treatment planning system. As a result, the 1.5 T MRI-linac 7 MV FFF beam has been characterised for the first time and is suitable for clinical use. This was a key step towards the first clinical treatments with the MRI-linac, which were delivered at University Medical Center Utrecht in May 2017 (Raaymakers et al 2017 Phys. Med. Biol. 62 L41-50).