RESUMEN
Traumatic brain injury (TBI) is one of the common injuries when the human head receives an impact due to an accident or fall and is one of the most frequently submitted insurance claims. However, it is often always misused when individuals attempt an insurance fraud claim by providing false medical conditions. Therefore, there is a need for an instant brain condition classification system. This study presents a novel classification architecture that can classify non-severe TBI patients and healthy subjects employing resting-state electroencephalogram (EEG) as the input, solving the immobility issue of the computed tomography (CT) scan and magnetic resonance imaging (MRI). The proposed architecture makes use of long short term memory (LSTM) and error-correcting output coding support vector machine (ECOC-SVM) to perform multiclass classification. The pre-processed EEG time series are supplied to the network by each time step, where important information from the previous time step will be remembered by the LSTM cell. Activations from the LSTM cell is used to train an ECOC-SVM. The temporal advantages of the EEG were amplified and able to achieve a classification accuracy of 100%. The proposed method was compared to existing works in the literature, and it is shown that the proposed method is superior in terms of classification accuracy, sensitivity, specificity, and precision.
Asunto(s)
Lesiones Traumáticas del Encéfalo , Electroencefalografía , Máquina de Vectores de Soporte , Lesiones Traumáticas del Encéfalo/clasificación , Lesiones Traumáticas del Encéfalo/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos XRESUMEN
Traumatic brain injury (TBI) is one of the injuries that can bring serious consequences if medical attention has been delayed. Commonly, analysis of computed tomography (CT) or magnetic resonance imaging (MRI) is required to determine the severity of a moderate TBI patient. However, due to the rising number of TBI patients these days, employing the CT scan or MRI scan to every potential patient is not only expensive, but also time consuming. Therefore, in this paper, we investigate the possibility of using electroencephalography (EEG) with computational intelligence as an alternative approach to detect the severity of moderate TBI patients. EEG procedure is much cheaper than CT or MRI. Although EEG does not have high spatial resolutions as compared with CT and MRI, it has high temporal resolutions. The analysis and prediction of moderate TBI from EEG using conventional computational intelligence approaches are tedious as they normally involve complex preprocessing, feature extraction, or feature selection of the signal. Thus, we propose an approach that uses convolutional neural network (CNN) to automatically classify healthy subjects and moderate TBI patients. The input to this computational intelligence system is the resting-state eye-closed EEG, without undergoing preprocessing and feature selection. The EEG dataset used includes 15 healthy volunteers and 15 moderate TBI patients, which is acquired at the Hospital Universiti Sains Malaysia, Kelantan, Malaysia. The performance of the proposed method has been compared with four other existing methods. With the average classification accuracy of 72.46%, the proposed method outperforms the other four methods. This result indicates that the proposed method has the potential to be used as a preliminary screening for moderate TBI, for selection of the patients for further diagnosis and treatment planning.
Asunto(s)
Conmoción Encefálica/diagnóstico , Electroencefalografía , Redes Neurales de la Computación , Procesamiento de Señales Asistido por Computador , Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto JovenRESUMEN
Biometric is an important field that enables identification of an individual to access their sensitive information and asset. In recent years, electroencephalography- (EEG-) based biometrics have been popularly explored by researchers because EEG is able to distinct between two individuals. The literature reviews have shown that convolutional neural network (CNN) is one of the classification approaches that can avoid the complex stages of preprocessing, feature extraction, and feature selection. Therefore, CNN is suggested to be one of the efficient classifiers for biometric identification. Conventionally, input to CNN can be in image or matrix form. The objective of this paper is to explore the arrangement of EEG for CNN input to investigate the most suitable input arrangement of EEG towards the performance of EEG-based identification. EEG datasets that are used in this paper are resting state eyes open (REO) and resting state eyes close (REC) EEG. Six types of data arrangement are compared in this paper. They are matrix of amplitude versus time, matrix of energy versus time, matrix of amplitude versus time for rearranged channels, image of amplitude versus time, image of energy versus time, and image of amplitude versus time for rearranged channels. It was found that the matrix of amplitude versus time for each rearranged channels using the combination of REC and REO performed the best for biometric identification, achieving validation accuracy and test accuracy of 83.21% and 79.08%, respectively.