Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Struct Dyn ; 11(1): 014303, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38406321

RESUMEN

A long-standing motivation driving high-speed electron microscopy development is to capture phase transformations and material dynamics in real time with high spatial and temporal resolution. Current dynamic transmission electron microscopes (DTEMs) are limited to nanosecond temporal resolution and the ability to capture only a few frames of a transient event. With the motivation to overcome these limitations, we present our progress in developing a streak-mode DTEM (SM-DTEM) and demonstrate the recovery of picosecond images with high frame sequence depth. We first demonstrate that a zero-dimensional (0D) SM-DTEM can provide temporal information on any local region of interest with a 0.37 µm diameter, a 20-GHz sampling rate, and 1200 data points in the recorded trace. We use this method to characterize the temporal profile of the photoemitted electron pulse, finding that it deviates from the incident ultraviolet laser pulse and contains an unexpected peak near its onset. Then, we demonstrate a two-dimensional (2D) SM-DTEM, which uses compressed-sensing-based tomographic imaging to recover a full spatiotemporal photoemission profile over a 1.85-µm-diameter field of view with nanoscale spatial resolution, 370-ps inter-frame interval, and 140-frame sequence depth in a 50-ns time window. Finally, a perspective is given on the instrumental modifications necessary to further develop this promising technique with the goal of decreasing the time to capture a 2D SM-DTEM dataset.

2.
Nat Commun ; 15(1): 1589, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38383494

RESUMEN

Single-shot real-time femtophotography is indispensable for imaging ultrafast dynamics during their times of occurrence. Despite their advantages over conventional multi-shot approaches, existing techniques confront restricted imaging speed or degraded data quality by the deployed optoelectronic devices and face challenges in the application scope and acquisition accuracy. They are also hindered by the limitations in the acquirable information imposed by the sensing models. Here, we overcome these challenges by developing swept coded aperture real-time femtophotography (SCARF). This computational imaging modality enables all-optical ultrafast sweeping of a static coded aperture during the recording of an ultrafast event, bringing full-sequence encoding of up to 156.3 THz to every pixel on a CCD camera. We demonstrate SCARF's single-shot ultrafast imaging ability at tunable frame rates and spatial scales in both reflection and transmission modes. Using SCARF, we image ultrafast absorption in a semiconductor and ultrafast demagnetization of a metal alloy.

3.
J Biomed Opt ; 29(Suppl 1): S11524, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38292055

RESUMEN

Significance: Compressed ultrafast photography (CUP) is currently the world's fastest single-shot imaging technique. Through the integration of compressed sensing and streak imaging, CUP can capture a transient event in a single camera exposure with imaging speeds from thousands to trillions of frames per second, at micrometer-level spatial resolutions, and in broad sensing spectral ranges. Aim: This tutorial aims to provide a comprehensive review of CUP in its fundamental methods, system implementations, biomedical applications, and prospect. Approach: A step-by-step guideline to CUP's forward model and representative image reconstruction algorithms is presented with sample codes and illustrations in Matlab and Python. Then, CUP's hardware implementation is described with a focus on the representative techniques, advantages, and limitations of the three key components-the spatial encoder, the temporal shearing unit, and the two-dimensional sensor. Furthermore, four representative biomedical applications enabled by CUP are discussed, followed by the prospect of CUP's technical advancement. Conclusions: CUP has emerged as a state-of-the-art ultrafast imaging technology. Its advanced imaging ability and versatility contribute to unprecedented observations and new applications in biomedicine. CUP holds great promise in improving technical specifications and facilitating the investigation of biomedical processes.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Fotograbar , Fotograbar/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos
4.
Adv Sci (Weinh) ; 11(11): e2305284, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38183381

RESUMEN

The short-wave infrared (SWIR) photoluminescence lifetimes of rare-earth doped nanoparticles (RENPs) have found diverse applications in fundamental and applied research. Despite dazzling progress in the novel design and synthesis of RENPs with attractive optical properties, existing optical systems for SWIR photoluminescence lifetime imaging are still considerably restricted by inefficient photon detection, limited imaging speed, and low sensitivity. To overcome these challenges, SWIR photoluminescence lifetime imaging microscopy using an all-optical streak camera (PLIMASC) is developed. Synergizing scanning optics and a high-sensitivity InGaAs CMOS camera, SWIR-PLIMASC has a 1D imaging speed of up to 138.9 kHz in the spectral range of 900-1700 nm, which quantifies the photoluminescence lifetime of RENPs in a single shot. A 2D photoluminescence lifetime map can be acquired by 1D scanning of the sample. To showcase the power of SWIR-PLIMASC, a series of core-shell RENPs with distinct SWIR photoluminescence lifetimes is synthesized. In particular, using Er3+ -doped RENPs, SWIR-PLIMASC enables multiplexed anti-counterfeiting. Leveraging Ho3+ -doped RENPs as temperature indicators, this system is applied to SWIR photoluminescence lifetime-based thermometry. Opening up a new avenue for efficient SWIR photoluminescence lifetime mapping, this work is envisaged to contribute to advanced materials characterization, information science, and biomedicine.

5.
Opt Express ; 30(11): 19824-19838, 2022 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-36221749

RESUMEN

Dynamic three-dimensional (3D) surface imaging by phase-shifting fringe projection profilometry has been widely implemented in diverse applications. However, existing techniques fall short in simultaneously providing the robustness in solving spatially isolated 3D objects, the tolerance of large variation in surface reflectance, and the flexibility of tunable working distances with meter-square-level fields of view (FOVs) at video rate. In this work, we overcome these limitations by developing multi-scale band-limited illumination profilometry (MS-BLIP). Supported by the synergy of dual-level intensity projection, multi-frequency fringe projection, and an iterative method for distortion compensation, MS-BLIP can accurately discern spatially separated 3D objects with highly varying reflectance. MS-BLIP is demonstrated by dynamic 3D imaging of a translating engineered box and a rotating vase. With an FOV of up to 1.7 m × 1.1 m and a working distance of up to 2.8 m, MS-BLIP is applied to capturing full human-body movements at video rate.


Asunto(s)
Imagenología Tridimensional , Iluminación , Algoritmos , Humanos , Imagenología Tridimensional/métodos
6.
Nat Commun ; 12(1): 6401, 2021 Nov 04.
Artículo en Inglés | MEDLINE | ID: mdl-34737314

RESUMEN

Photoluminescence lifetime imaging of upconverting nanoparticles is increasingly featured in recent progress in optical thermometry. Despite remarkable advances in photoluminescent temperature indicators, existing optical instruments lack the ability of wide-field photoluminescence lifetime imaging in real time, thus falling short in dynamic temperature mapping. Here, we report video-rate upconversion temperature sensing in wide field using single-shot photoluminescence lifetime imaging thermometry (SPLIT). Developed from a compressed-sensing ultrahigh-speed imaging paradigm, SPLIT first records wide-field luminescence intensity decay compressively in two views in a single exposure. Then, an algorithm, built upon the plug-and-play alternating direction method of multipliers, is used to reconstruct the video, from which the extracted lifetime distribution is converted to a temperature map. Using the core/shell NaGdF4:Er3+,Yb3+/NaGdF4 upconverting nanoparticles as the lifetime-based temperature indicators, we apply SPLIT in longitudinal wide-field temperature monitoring beneath a thin scattering medium. SPLIT also enables video-rate temperature mapping of a moving biological sample at single-cell resolution.

7.
Opt Lett ; 46(7): 1788-1791, 2021 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-33793544

RESUMEN

Existing streak-camera-based two-dimensional (2D) ultrafast imaging techniques are limited by long acquisition time, the trade-off between spatial and temporal resolutions, and a reduced field of view. They also require additional components, customization, or active illumination. Here we develop compressed ultrafast tomographic imaging (CUTI), which passively records 2D transient events with a standard streak camera. By grafting the concept of computed tomography to the spatiotemporal domain, the operations of temporal shearing and spatiotemporal integration in a streak camera's data acquisition can be equivalently expressed as the spatiotemporal projection of an (x,y,t) datacube from a certain angle. Aided by a new, to the best of our knowledge, compressed-sensing reconstruction algorithm, the 2D transient event can be accurately recovered in a few measurements. CUTI is exhibited as a new imaging mode universally adaptable to most streak cameras. Implemented in an image-converter streak camera, CUTI captures the sequential arrival of two spatially modulated ultrashort ultraviolet laser pulses at 0.5 trillion frames per second. Applied to a rotating-mirror streak camera, CUTI records an amination of fast-bouncing balls at 5,000 frames per second.

8.
Opt Express ; 27(9): 13061-13071, 2019 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-31052836

RESUMEN

Holographic lithography is widely used as an effective approach for two-dimensional (2D) photonic crystal fabrication. However, for the fabrication of 2D polarization structures based on photoaligned liquid crystals (LCs), holographic lithography method is limited. The fabrication requires full coverage of light intensity, 2D chiral distribution and continuously varying polarization direction, which could be hardly guaranteed by multi-beam interference of circularly polarized light (CPL). Herein, we introduce a linearly polarized light (LPL) into a three-CPL interference configuration to improve the interference field and fulfill the critical requirement. The introduced LPL intensity is chosen to be 1/5 of the CPL to guarantee both full coverage of light intensity and well photoalignment defined LC directors. Moreover, the introduction of the weak LPL into multiple CPL interference is shown to give little disturbance to the desired diffraction properties.

9.
J Assist Reprod Genet ; 19(10): 493-9, 2002 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-12416655

RESUMEN

PURPOSE: Ovarian tissue banking may be the best strategy to preserve female fertility. But optimal method to obtain viable mature oocytes remains challenging. In order to bypass the long in vitro oocyte growth period, we developed this study to test whether reconstruction of thawed primordial oocytes with enucleated preovulatory germinal vesicle (GV) oocytes could induce dictyate nuclei to undergo chromosomal condensation and meiotic maturation. METHODS: Isolated primordial oocytes from thawed mouse ovarian tissue were reconstructed with enucleated GV oocytes. After electrofusion and in vitro maturation, the reconstituted oocytes were assessed for first polar body extrusion, cytoskeleton configuration, and chromosome abnormalities. RESULTS: Primordial oocytes from thawed ovarian tissue showed a high survival rate. Following transfer and electrofusion, they could be fused with enucleated GV oocytes (35.6%, 36/101) and extruded a first polar body (52.8%,19/36). These mature oocytes showed a normal spindle configuration and chromosome number. CONCLUSIONS: We successfully established a mouse cell model to prove that omitting the whole growth and maturation period by transfer of primordial oocytes to developmentally older enucleated oocytes would bypass the long growth period required to the preovulatory stage. Polar body extrusion could also ensue after in vitro growth. This study provided an alternative approach for future investigations in oocyte maturation.


Asunto(s)
Criopreservación , Meiosis/fisiología , Técnicas de Transferencia Nuclear , Oocitos/fisiología , Animales , División Celular/fisiología , Núcleo Celular/fisiología , Supervivencia Celular , Citoplasma/fisiología , Ratones , Micromanipulación , Oocitos/ultraestructura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...