Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Curr Cardiol Rep ; 23(10): 139, 2021 08 19.
Artículo en Inglés | MEDLINE | ID: mdl-34410518

RESUMEN

PURPOSE OF REVIEW: New transcatheter techniques to perform tricuspid annuloplasty are evolving and are introduced into the clinical routine. Yet, clinical experience is limited. RECENT FINDINGS: Currently, 3 different techniques for tricuspid annuloplasty have been used in larger clinical cohorts. They can be divided into direct annuloplasty techniques and suture plication techniques. The largest clinical evidence is related to direct annuloplasty techniques. It has been shown that annular dimensions can be effectively reduced. This translates into an improvement of the degree of tricuspid regurgitation and improvement of clinical symptoms. Due to the newness of this type of therapy, long-term data is limited, but for one of the described techniques, published data show that the positive effects persist over a 2-year period. Transcatheter approaches are safe and are able to treat tricuspid regurgitation effectively. There are still differences in the efficacy of the different techniques. Clinical experience varies among the different approaches.


Asunto(s)
Anuloplastia de la Válvula Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Factores de Tiempo , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/cirugía
3.
EuroIntervention ; 17(10): 809-817, 2021 Nov 19.
Artículo en Inglés | MEDLINE | ID: mdl-34031021

RESUMEN

BACKGROUND: Severe tricuspid regurgitation (TR) has limited treatment options and is associated with high morbidity and mortality. AIMS: We evaluated the safety and effectiveness of the Cardioband tricuspid valve reconstruction system from the ongoing European single-arm, multicentre, prospective TriBAND post-market clinical follow-up study. METHODS: Eligible patients had chronic symptomatic functional TR despite diuretic therapy and were deemed candidates for transcatheter tricuspid repair by the local Heart Team. RESULTS: Sixty-one patients had ≥severe functional TR. At baseline, 85% of patients were in NYHA Class III-IV, 94% had ≥severe TR (core laboratory-assessed) with 6.8% EuroSCORE II and 53% LVEF. Device success was 96.7%. At discharge, 59% (p<0.001) of patients achieved ≤moderate TR and 78% had at least one grade TR reduction. At 30 days, all-cause mortality and composite MAE rates were 1.6% and 19.7%, respectively; septolateral annular diameter was reduced by 20%, where 69% of patients achieved ≤moderate TR and 85% of patients had at least one grade TR reduction (all p<0.001). Mid-RVEDD, RA volume, and IVC diameter decreased by 10% (p=0.005), 21% (p<0.001), and 11% (p=0.022), respectively; 74% were in NYHA Class I-II (p<0.001) with improvements in overall KCCQ score by 17 points (p<0.001). CONCLUSIONS: In the TriBAND study, the Cardioband tricuspid system demonstrated favourable outcomes at discharge and 30 days in a challenging patient population with symptomatic ≥severe functional TR. Results showed significant reductions in annular diameter and TR severity, accompanied by early evidence of right heart remodelling and improvements in functional status and quality of life.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Cateterismo Cardíaco , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Estudios Prospectivos , Calidad de Vida , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía
4.
Front Cardiovasc Med ; 8: 619605, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33614749

RESUMEN

Transcatheter techniques for the treatment of tricuspid regurgitation (TR) are being more frequently used and several new devices are in development. Since 90% of patients with TR have secondary TR, catheter based systems which reduce the dilated tricuspid annulus area are of particular interest. In order to perform an annuloplasty procedure effectively and safely, knowledge about the anatomy of the tricuspid valve apparatus and especially of the annulus in relation to the important neighboring structures such as the aortic root, the RCA, the electrical pathways and the CS is fundamental. In addition, comprehensive understanding of the device itself, the delivery system, its maneuverability and the individual procedural steps is required. Furthermore, the use of multi-modality imaging is important. For each step of the procedure the appropriate imaging modality as well as the optimal; imaging planes are crucial to provide the necessary information to best guide the individual procedural step.

5.
EuroIntervention ; 17(1): 81-87, 2021 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-32657277

RESUMEN

BACKGROUND: The Cardioband tricuspid valve reconstruction system is a size-adjustable tricuspid reconstruction device for interventional treatment of tricuspid regurgitation (TR). Contraction of the device after successful implantation can be associated with an acute deformation of the right coronary artery (RCA). AIMS: The aim of this study was to provide data on the persistence and clinical significance of acute RCA deformation following Cardioband implant procedures. METHODS: Data from all patients with intraprocedural RCA deformation during Cardioband implantation were collected from four centres between October 2018 and January 2020. Control angiographies were performed in all of these patients before discharge. RESULTS: RCA deformation occurred in 14 out of 51 patients. Follow-up coronary angiography showed a complete resolution of deformation in all cases while patients remained clinically asymptomatic and had an uneventful post-interventional course. Intraprocedural coronary stent implantation was performed in two of the earlier cases according to the personal assessment of the implanters. CONCLUSIONS: RCA deformation is relatively frequent following interventional tricuspid annuloplasty but appears to be completely reversible in the absence of flow impairment or vascular damage. Based on our early experience watchful waiting is the most appropriate strategy to avoid unnecessary coronary interventions.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Cateterismo Cardíaco/efectos adversos , Angiografía Coronaria , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía
6.
Mov Disord ; 22(2): 265-7, 2007 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-17149711

RESUMEN

We describe a novel mutation in the gene coding for protein kinase C gamma (PRKCG) in patients of a German family affected with slowly progressive gait ataxia, dysarthria, and nystagmus. The G/T missense mutation occurred in exon 2 of PRKCG and results in a substitution of glycine by valine (G63V) in the evolutionarily highly conserved cysteine-rich region 1/C1 domain of PRKCG. Among the 20 mutations described to date, this is the first mutation located in exon 2 of PRKCG.


Asunto(s)
Exones/genética , Mutación Puntual/genética , Proteína Quinasa C/genética , Ataxias Espinocerebelosas/clasificación , Ataxias Espinocerebelosas/genética , Análisis Mutacional de ADN , Alemania , Humanos , Masculino , Persona de Mediana Edad , Linaje , Enfermedades Raras , Transducción de Señal
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...