Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Thorac Cardiovasc Surg ; 164(2): 585-595.e5, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-33431210

RESUMEN

OBJECTIVE: Perioperative right ventricular function is a significant predictor of patient outcomes after cardiac surgery. This prospective study aimed to identify perioperative factors associated with reduced intraoperative right ventricular function. METHODS: Right ventricular function was assessed at the beginning and end of surgery by standardized transesophageal echocardiographic measurements, including tricuspid annular plane systolic excursion, peak systolic longitudinal right ventricular strain, and fractional area change, in 109 adult patients undergoing cardiac surgery at Cleveland Clinic. Associations between right ventricular function and 33 patient characteristics and perioperative factors were analyzed by random forest machine learning. The relative importance of each variable in predicting right ventricular function at the end of surgery was determined. RESULTS: Longer aortic clamp duration and lower baseline right ventricular function were highly important variables for predicting worse right ventricular function measured by tricuspid annular plane systolic excursion, right ventricular strain, and fractional area change at the end of surgery. For example, right ventricular function after longer aortic clamp times of 100-120 minutes was worse (median [Q1, Q3] tricuspid annular plane systolic excursion 1.0 [0.9, 1.1] cm) compared with right ventricular function after shorter aortic clamp times of 50 to 70 minutes (tricuspid annular plane systolic excursion 1.5 [1.3, 1.7]; P = .001). Right ventricular strain at the end of surgery was reduced in patients with worse baseline right ventricular function compared with those with higher baseline right ventricular function (end of surgery right ventricular strain in lowest quartile -13.7 [-16.6, -12.4]% vs highest quartile -17.7 [-18.6, -15.3]% of baseline right ventricular function; P = .043). CONCLUSIONS: Intraoperative decline in right ventricular function is associated with longer aortic clamp time and worse baseline right ventricular function. Efforts to optimize these factors, including better myocardial protection strategies, may improve perioperative right ventricular function.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Disfunción Ventricular Derecha , Adulto , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Ecocardiografía Transesofágica , Ventrículos Cardíacos , Humanos , Estudios Prospectivos , Disfunción Ventricular Derecha/diagnóstico por imagen , Disfunción Ventricular Derecha/etiología , Disfunción Ventricular Derecha/prevención & control , Función Ventricular Derecha
2.
Front Cardiovasc Med ; 8: 762839, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34957252

RESUMEN

Background: Catheter ablation (CA) for atrial fibrillation (AF), may require ablation beyond the pulmonary veins. Prior data suggest that additional LA ablation, particularly left atrial appendage (LAA) ablation, may alter atrial function leading to increased risk of ischemic stroke or transient ischemic attack (IS/TIA). We sought to study the long-term risk of IS/TIA in patients receiving ablation at the LAA compared to those receiving PVI alone and those receiving PVI with additional non-LAA locations. Methods: 350 patients who underwent CA for AF from 2008 to 2018 were included in the study. Locations of ablation in LA evaluated were the posterior wall, anterior wall, inferior wall, inter-atrial septum, lateral wall and the left atrial appendage (LAA). Patients undergoing LAA ablation were further divided as complete isolation (LAAi) and without complete isolation (LAAa). Results: Mean follow up of 4.8 years. In entire cohort, risk of IS/TIA was 1.62/100 patient-years (pys). The risk was highest in patients with LAAi (3.81/100 pys), followed by ablation LAAa (3.74/100 pys). Amongst all LA locations, only LAAi (HR 3.32, p = 0.03) and LAAa (HR 3.18, p = 0.02) were statistically significant predictors of IS/TIA after adjusting for OAC (Oral anticoagulant) use and baseline CHA2DS2VASc score. Conclusions: During long term follow-up, only ablation at the left atrial appendage with and without complete isolation was independently associated with an increased risk of IS/TIA in patients undergoing CA for AF. Potential strategies to reduce stroke risk, such as LAA closure, should be considered in these patients.

3.
Gastroenterol Rep (Oxf) ; 9(4): 306-312, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34567562

RESUMEN

BACKGROUND: The effect of transjugular intra-hepatic portosystemic shunt (TIPS) placement on renal function and the correlation of post-TIPS Cr with mortality remain unclear. This study aimed to assess the effect of TIPS placement on renal function and to examine the relationship between post-TIPS Cr and mortality risk. METHODS: A total of 593 patients who underwent de novo TIPS placement between 2004 and 2017 at a single institution were included in the study. The pre-TIPS Cr level (T0; within 7 days before TIPS placement) and post-TIPS Cr levels, at 1-2 days (T1), 5-12 days (T2), and 15-40 days (T3), were collected. Predictors of Cr change after TIPS placement and the 1-year mortality rate were analysed using multivariable linear-regression and Cox proportional-hazards models, respectively. RESULTS: Overall, 21.4% of patients (n = 127) had elevated baseline Cr (≥1.5 mg/dL; mean, 2.51 ± 1.49 mg/dL) and 78.6% (n = 466) had normal baseline Cr (<1.5 mg/dL; mean, 0.92 ± 0.26 mg/dL). Patients with elevated pre-TIPS Cr demonstrated a decrease in post-TIPS Cr (difference, -0.60 mg/dL), whereas patients with normal baseline Cr exhibited no change (difference, <0.01 mg/dL). The 30-day, 90-day, and 1-year mortality rates were 13%, 20%, and 32%, respectively. Variceal bleeding as a TIPS-placement indication (hazard ratio = 1.731; P = 0.036), higher T0 Cr (hazard ratio = 1.834; P = 0.012), and higher T3 Cr (hazard ratio = 3.524; P < 0.001) were associated with higher 1-year mortality risk. CONCLUSION: TIPS placement improved renal function in patients with baseline renal dysfunction and the post-TIPS Cr level was a strong predictor of 1-year mortality risk.

4.
Anesth Analg ; 131(4): 1217-1227, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32925343

RESUMEN

BACKGROUND: Manual processes for verifying patient identification before blood transfusion and documenting this pretransfusion safety check are prone to errors, and compliance with manual systems is especially poor in urgent operating room settings. An automated, electronic barcode scanner system would be expected to improve pretransfusion verification and documentation. METHODS: Audits were conducted of blood transfusion documentation under a manual paper system from January to October 2014. An electronic barcode scanning system was developed to streamline transfusion safety checking and automate documentation. This system was implemented in 58 operating rooms between October and December 2014, with follow-up compliance audits through December 2015. The association of barcode scanner implementation with transfusion documentation compliance was assessed using an interrupted time series analysis. Anesthesia providers were surveyed regarding their opinions on the electronic system. In mid-2016, the scanning system was modified to transfer from the Metavision medical record system to Epic OpTime. Follow-up analysis assessed performance of this system within Epic during 2017. RESULTS: In an interrupted time series analysis, the proportion of units with compliant documentation was estimated to be 19.6% (95% confidence interval [CI], 10.7-25.6) the week before scanner implementation, and 74.4% (95% CI, 59.4-87.4) the week after implementation. There was a significant postintervention level change (odds ratio 10.80, 95% CI, 6.31-18.70; P < .001) and increase in slope (odds ratio 1.14 per 1-week increase, 95% CI, 1.11-1.17; P < .001). After implementation, providers chose to use the new electronic system for 98% of transfusions. Across the 2 years analyzed (15,997 transfusions), the electronic system detected 45 potential transfusion errors in 27 unique patients, and averted transfusion of 36 mismatched blood products into 20 unique patients. A total of 69%, 86%, and 88% of providers reported the electronic system improved patient safety, blood transfusion workflow, and transfusion documentation, respectively. When providers used the barcode scanner, no transfusion errors or reactions were reported. The scanner system was successfully transferred from Metavision to Epic without retraining staff or changing workflows. CONCLUSIONS: A barcode-based system designed for easy integration to different commonly used anesthesia information management systems was implemented in a large urban academic hospital. The system allows a single user with the assistance of a software system to perform and document pretransfusion safety verification. The system improved transfusion documentation compliance, averted potential transfusion errors, and became the preferred method of blood transfusion safety checking.


Asunto(s)
Transfusión Sanguínea/métodos , Procesamiento Automatizado de Datos , Registros Electrónicos de Salud/organización & administración , Quirófanos/organización & administración , Adulto , Documentación , Adhesión a Directriz , Humanos , Análisis de Series de Tiempo Interrumpido , Errores Médicos/prevención & control , Seguridad del Paciente , Mejoramiento de la Calidad , Flujo de Trabajo
5.
Acad Radiol ; 27(10): 1353-1362, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32830030

RESUMEN

RATIONALE AND OBJECTIVES: While affiliated imaging centers play an important role in healthcare systems, little is known of how their operations are impacted by the COVID-19 pandemic. Our goal was to investigate imaging volume trends during the pandemic at our large academic hospital compared to the affiliated imaging centers. MATERIALS AND METHODS: This was a descriptive retrospective study of imaging volume from an academic hospital (main hospital campus) and its affiliated imaging centers from January 1 through May 21, 2020. Imaging volume assessment was separated into prestate of emergency (SOE) period (before SOE in Massachusetts on March 10, 2020), "post-SOE" period (time after "nonessential" services closure on March 24, 2020), and "transition" period (between pre-SOE and post-SOE). RESULTS: Imaging volume began to decrease on March 11, 2020, after hospital policy to delay nonessential studies. The average weekly imaging volume during the post-SOE period declined by 54% at the main hospital campus and 64% at the affiliated imaging centers. The rate of imaging volume recovery was slower for affiliated imaging centers (slope = 6.95 for weekdays) compared to main hospital campus (slope = 7.18 for weekdays). CT, radiography, and ultrasound exhibited the lowest volume loss, with weekly volume decrease of 41%, 49%, and 53%, respectively, at the main hospital campus, and 43%, 61%, and 60%, respectively, at affiliated imaging centers. Mammography had the greatest volume loss of 92% at both the main hospital campus and affiliated imaging centers. CONCLUSION: Affiliated imaging center volume decreased to a greater degree than the main hospital campus and showed a slower rate of recovery. Furthermore, the trend in imaging volume and recovery were temporally related to public health announcements and COVID-19 cases.


Asunto(s)
Betacoronavirus , Infecciones por Coronavirus , Pandemias , Neumonía Viral , COVID-19 , Hospitales , Humanos , Massachusetts , Estudios Retrospectivos , SARS-CoV-2 , Servicios Urbanos de Salud
8.
Respir Med ; 164: 105903, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32217289

RESUMEN

Aspergilloma, also known as mycetoma or fungus ball, is the most common manifestation of pulmonary involvement by Aspergillus species. The fungal ball typically forms within preexisting cavities of the lungs. Diagnosis requires both radiographic evidence along with serologic or microbiologic evidence of Aspergillus species involvement. While clinical features such as hemoptysis, chest pain, shortness of breath, cough, and fever are helpful in diagnosis, they are non-specific symptoms. Surgery is currently the mainstay of treatment for aspergilloma but is associated with considerable mortality and morbidity. Alternative options exist for patients who are poor surgical candidates and for those who prefer a less invasive treatment modality. Systemic treatment with amphotericin B is ineffective and is not recommended as a monotherapy, but systemic azoles is effective in approximately 50-80% of patients. Potential alternatives to surgery include intracavitary instillation or endobronchial administration of antifungal medication, as well as direct transbronchial aspergilloma removal. Bronchial artery embolization and radiotherapy are options to manage hemoptysis until definite eradication of the aspergilloma. More rigorous studies are needed to better establish non-surgical treatment paradigm for inoperable patients.


Asunto(s)
Anfotericina B/administración & dosificación , Antifúngicos/administración & dosificación , Azoles/administración & dosificación , Tratamiento Conservador/métodos , Aspergilosis Pulmonar/terapia , Arterias Bronquiales , Embolización Terapéutica/métodos , Femenino , Hemoptisis/etiología , Hemoptisis/terapia , Humanos , Instilación de Medicamentos , Masculino , Aspergilosis Pulmonar/complicaciones , Aspergilosis Pulmonar/radioterapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...