Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Appl Clin Med Phys ; 23(9): e13731, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35920116

RESUMEN

Accurate coregistration of computed tomography (CT) and magnetic resonance (MR) imaging can provide clinically relevant and complementary information and can serve to facilitate multiple clinical tasks including surgical and radiation treatment planning, and generating a virtual Positron Emission Tomography (PET)/MR for the sites that do not have a PET/MR system available. Despite the long-standing interest in multimodality co-registration, a robust, routine clinical solution remains an unmet need. Part of the challenge may be the use of mutual information (MI) maximization and local phase difference (LPD) as similarity metrics, which have limited robustness, efficiency, and are difficult to optimize. Accordingly, we propose registering MR to CT by mapping the MR to a synthetic CT intermediate (sCT) and further using it in a sCT-CT deformable image registration (DIR) that minimizes the sum of squared differences. The resultant deformation field of a sCT-CT DIR is applied to the MRI to register it with the CT. Twenty-five sets of abdominopelvic imaging data are used for evaluation. The proposed method is compared to standard MI- and LPD-based methods, and the multimodality DIR provided by a state of the art, commercially available FDA-cleared clinical software package. The results are compared using global similarity metrics, Modified Hausdorff Distance, and Dice Similarity Index on six structures. Further, four physicians visually assessed and scored registered images for their registration accuracy. As evident from both quantitative and qualitative evaluation, the proposed method achieved registration accuracy superior to LPD- and MI-based methods and can refine the results of the commercial package DIR when using its results as a starting point. Supported by these, this manuscript concludes the proposed registration method is more robust, accurate, and efficient than the MI- and LPD-based methods.


Asunto(s)
Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Algoritmos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Imagen Multimodal , Tomografía de Emisión de Positrones , Tomografía Computarizada por Rayos X/métodos
2.
Int J Part Ther ; 7(4): 42-51, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33829072

RESUMEN

PURPOSE: Periorbital tumor location presents a significant challenge with 3-dimensional conformal radiation therapy or intensity modulated radiation therapy due to high tumor dose needed in the setting of close proximity to orbital structures with lower tolerance. Proton beam therapy (PBT) is felt to be an effective modality in such cases due to its sharp dose gradient. MATERIALS AND METHODS: We reviewed our institutional PBT registry and identified 17 patients with tumor epicenters within 2 cm of the eye and optic apparatus treated with passive scatter PBT with comparison volumetric arc therapy plans available. Maximum and mean doses to organs at risk of interest, including optic nerves, optic chiasm, lens, eye ball, pituitary, cochlea, lacrimal gland, and surrounding brain, were compared using the paired Wilcoxon signed rank test. Overall survival was determined using the Kaplan-Meier method. RESULTS: Median age was 67. Median follow-up was 19.7 months. Fourteen patients underwent upfront resection and received postoperative radiation and 3 received definitive radiation. One patient received elective neck radiation, 2 underwent reirradiation, and 3 had concurrent chemotherapy. There was a statistically significant reduction in mean dose to the optic nerves and chiasm, brain, pituitary gland, lacrimal glands, and cochlea as well as in the maximum dose to the optic nerves and chiasm, pituitary gland, lacrimal glands, and cochlea with PBT. The 18-month cumulative incidence of local failure was 19.1% and 1-year overall survival was 80.9%. CONCLUSION: Proton beam therapy resulted in significant dose reductions to several periorbital and optic structures compared with volumetric arc therapy. Proton beam therapy appears to be the optimal radiation modality in such cases to minimize risk of toxicity to periorbital organs at risk.

3.
Brachytherapy ; 20(2): 353-360, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33187822

RESUMEN

PURPOSE: The in vivo dosimetric monitoring in HDR brachytherapy is important for improving patient safety. However, there are very limited options available for clinical application. In this study, we present a new in vivo dose measurement system with a plastic scintillating detector (PSD) for GYN HDR brachytherapy. METHODS: An FDA approved PSD system, called OARtrac (AngioDynamics, Latham, NY), was used with various applicators for in vivo dose measurements for GYN patients. An institutional workflow was established for the clinical implementation of the dosimetric system. Action levels were proposed based on the measurement and system uncertainty for measurement deviations. From October 2018 to September 2019, a total of 75 measurements (48 fractions) were acquired from 14 patients who underwent HDR brachytherapy using either a multichannel cylinder, Venezia applicator, or Syed-Neblett template. The PSDs were placed in predetermined catheters/channels. A planning CT was acquired for treatment planning in Oncentra (Elekta, Version-4.5.2) TPS. The PSDs were contoured on the CT images, and the PSD D90% values were used as the expected doses for comparison with the measured doses. RESULTS: The mean difference from patient measurements was -0.22% ± 5.98%, with 26% being the largest deviation from the expected value (Syed case). Large deviations were observed when detectors were placed in the area where dose rates were less than 1 cGy/s. CONCLUSIONS: The establishment of clinical workflow for the in vivo dosimetry for both the intracavitary and interstitial GYN HDR brachytherapy will potentially improve the safety of the patient treatment.


Asunto(s)
Braquiterapia , Braquiterapia/métodos , Catéteres , Estudios de Factibilidad , Humanos , Radiometría , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
4.
J Appl Clin Med Phys ; 21(12): 263-271, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33270974

RESUMEN

PURPOSE/OBJECTIVES: The purpose of this study is to dually evaluate the effectiveness of PlanIQ in predicting the viability and outcome of dosimetric planning in cases of complex re-irradiation as well as generating an equivalent plan through Pinnacle integration. The study also postulates that a possible strength of PlanIQ lies in mitigating pre-optimization uncertainties tied directly to dose overlap regions where re-irradiation is necessary. METHODS: A retrospective patient selection (n = 20) included a diverse range of re-irradiation cases to be planned using Pinnacle auto-planning with PlanIQ integration. A consistent planning template was developed and applied across all cases. Direct plan comparisons of manual plans against feasibility-produced plans were performed by physician(s) with dosimetry recording relevant proximal OAR and planning timeline data. RESULTS AND DISCUSSION: All re-irradiation cases were successfully predicted to be achievable per PlanIQ analyses with three cases (3/20) necessitating 95% target coverage conditions, previously exhibited in the manually planned counterparts, and determined acceptable under institutional standards. At the same time, PlanIQ consistently produced plans of equal or greater quality to the previously manually planned re-irradiation across all (20/20) trials (P = 0.05). Proximal OAR exhibited similar to slightly improved maximum point doses from feasibility-based planning with the largest advantages gained found within the subset of cranial and spine overlap cases, where improvements upward of 10.9% were observed. Mean doses to proximal tissues were found to be a statistically significant (P < 0.05) 5.0% improvement across the entire study. Documented planning times were markedly less than or equal to the time contributed to manual planning across all cases. CONCLUSION: Initial findings indicate that PlanIQ effectively provides the user clear feasibility feedback capable of facilitating decision-making on whether re-irradiation dose objectives and prescription dose coverage are possible at the onset of treatment planning thus eliminating possible trial and error associated with some manual planning. Introducing model-based prediction tools into planning of complex re-irradiation cases yielded positive outcomes on the final treatment plans.


Asunto(s)
Radioterapia de Intensidad Modulada , Reirradiación , Benchmarking , Estudios de Factibilidad , Humanos , Órganos en Riesgo , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Estudios Retrospectivos
5.
Phys Rev Lett ; 114(10): 103002, 2015 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-25815927

RESUMEN

In a system of ultracold atoms near a Feshbach resonance, pairs of atoms can be associated into universal dimers by an oscillating magnetic field with a frequency near that determined by the dimer binding energy. We present a simple expression for the transition rate that takes into account many-body effects through a transition matrix element of the contact. In a thermal gas, the width of the peak in the transition rate as a function of the frequency is determined by the temperature. In a dilute Bose-Einstein condensate of atoms, the width is determined by the inelastic scattering rates of a dimer with zero-energy atoms. Near an atom-dimer resonance, there is a dramatic increase in the width from inelastic atom-dimer scattering and from atom-atom-dimer recombination. The recombination contribution provides a signature for universal tetramers that are Efimov states consisting of two atoms and a dimer.

6.
Phys Rev Lett ; 112(22): 222001, 2014 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-24949759

RESUMEN

Many of the XYZ mesons discovered in the last decade can be identified as bound states of a heavy quark and antiquark in Born-Oppenheimer (BO) potentials defined by the energy of gluon and light-quark fields in the presence of static color sources. The mesons include quarkonium hybrids, which are bound states in excited flavor-singlet BO potentials, and quarkonium tetraquarks, which are bound states in BO potentials with light-quark+antiquark flavor. The deepest hybrid potentials are known from lattice QCD calculations. The deepest tetraquark potentials can be inferred from lattice QCD calculations of static adjoint mesons. Selection rules for hadronic transitions are derived and used to identify XYZ mesons that are candidates for ground-state energy levels in the BO potentials for charmonium hybrids and tetraquarks.

7.
Phys Rev Lett ; 111(2): 023003, 2013 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-23889392

RESUMEN

Atom loss resonances in ultracold trapped atoms have been observed at scattering lengths near atom-dimer resonances, at which Efimov trimers cross the atom-dimer threshold, and near two-dimer resonances, at which universal tetramers cross the dimer-dimer threshold. We propose a new mechanism for these loss resonances in a Bose-Einstein condensate of atoms. As the scattering length is ramped to the large final value at which the atom loss rate is measured, the time-dependent scattering length generates a small condensate of shallow dimers coherently from the atom condensate. The coexisting atom and dimer condensates can be described by a low-energy effective field theory with universal coefficients that are determined by matching exact results from few-body physics. The classical field equations for the atom and dimer condensates predict narrow enhancements in the atom loss rate near atom-dimer resonances and near two-dimer resonances due to inelastic dimer collisions.

8.
Phys Rev Lett ; 108(6): 060402, 2012 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-22401040

RESUMEN

We derive universal relations for the rf spectroscopy of a two-dimensional Fermi gas consisting of two spin states interacting through an S-wave scattering length. The rf transition rate has a high-frequency tail that is proportional to the contact and displays logarithmic scaling violations, decreasing asymptotically like 1/(ω2ln2ω). Its coefficient is proportional to ln2'(a'(2D)/a(2D)), where a(2D) and a'(2D) are the two-dimensional scattering lengths associated with initial-state and final-state interactions. The clock shift is proportional to the contact and to ln(a'(2D)/a(2D)). If |ln(a'(2D)/a(2D))| >> 1, the clock shift arises as a cancellation between much larger contributions proportional to ln2(a'(2D)/a(2D)) from bound-bound and bound-free rf transitions.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...