Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
1.
Ann Thorac Surg ; 117(4): 753-760, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38081500

RESUMEN

BACKGROUND: This study sought to analyze the details of strokes after acute type A dissection repair (ATAD) using a right axillary artery (RAX) first approach. METHODS: A total of 356 consecutive ATAD repairs from 2005 to 2022 were analyzed on the basis of arterial cannulation site. Strokes were evaluated by head computed tomography. RESULTS: The rate of RAX cannulation was 82.6% (n = 294), with a 38.2% rate of antegrade cerebral perfusion use, both of which had increased over the years. The non-RAX group had more cardiogenic shock (RAX, 16.3% vs non-RAX, 37.1%; P < .001), cerebral malperfusion (8.8% vs 25.8%, respectively; P < .001), and innominate artery dissection (45.9% vs 69.2%, respectively; P = .007). Eight patients died before undergoing a full neurologic assessment. The overall stroke rate was 8.4% (n = 30), and it was lower in the RAX group (5.1% vs 24.2%; P < .001). All strokes were ischemic, with concomitant hemorrhagic strokes occurring in 6 patients. Strokes diagnosed immediately after surgery (perioperative stroke) accounted for 70% (n = 21 of 30) of cases. Strokes predominantly affected the right anterior circulation (right anterior, 80% vs left anterior, 46.7% vs left posterior, 26.7%; P = .013), independent of arterial cannulation site. The proposed mechanism of perioperative strokes was not uniform (embolism, 33.3%; hypoperfusion, 42.8%; embolism and hypoperfusion, 14.3%; lacunar infarct, 10%), whereas most postoperative strokes were embolic (77.8%). The mean National Institutes of Health Stroke Scale score was 20.6 ± 9.9, and the modified Rankin score at discharge was 4.1±2.2. CONCLUSIONS: Most strokes in ATAD occurred perioperatively from various mechanisms predominantly affecting the right anterior circulation irrespective of the arterial cannulation site. This complication is most likely the result of unstable hemodynamics and dissection of the innominate artery (IA) or its downstream vessels.


Asunto(s)
Disección Aórtica , Embolia , Accidente Cerebrovascular , Humanos , Cateterismo/métodos , Disección Aórtica/diagnóstico , Disección Aórtica/cirugía , Axila , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Arteria Axilar , Embolia/complicaciones , Resultado del Tratamiento , Estudios Retrospectivos
2.
Ann Cardiothorac Surg ; 12(5): 450-462, 2023 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-37817844

RESUMEN

Extensive thoracoabdominal aortic aneurysm repair can cause spinal cord ischemia which significantly impacts survival and quality of life. Although this complication is uncommon, it is important to recognize the pathophysiology and preventative measures. In the 1990s, Dr. Griepp and colleagues proposed the existence of an extensive collateral network that supports spinal cord perfusion, "the collateral network concept". This includes an interconnecting complex of vessels in the intraspinal, paraspinous, and epidural spaces, and in the paravertebral muscles, involving the intercostal and lumbar segmental arteries as well as the subclavian and hypogastric (iliac) arteries. In this concept, as opposed to the one major segmental input model such as the Adamkiewicz artery, recognition of the importance of multiple inputs to the spinal circulation is paramount to maintaining the spinal blood flow and preventing spinal cord ischemia. In this article, we review the current evidence of the collateral concept and its application in aortic surgery.

3.
JTCVS Tech ; 21: 7-17, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37854804

RESUMEN

Objective: With growing experience of acute type A aortic dissection repair, Zone 2 arch repair has been advocated. The aim of this study is to compare the outcome between "proximal-first" and "arch-first" Zone 2 repair. Methods: From January 2015 to March 2023, 45 patients underwent Zone 2 arch repair out of 208 acute type A aortic dissection repairs: arch-first, N = 19, and proximal-first technique, N = 26, since January 2021. Indications were aortic arch or descending tear, complex dissection in neck vessels, cerebral malperfusion, or aneurysm of the aortic arch. Results: The lowest bladder temperature was higher in the proximal-first technique (24.9 °C vs 19.7 °C, P < .001). Cardiopulmonary bypass (230 vs 177.5 minutes, P < .001), myocardial ischemic (124 vs 91 minutes, P < .001), and lower-body circulatory arrest (87 vs 28 minutes, P < .001) times were shorter in the proximal-first technique. The arch-first group required more packed red blood cells (arch-first, 2 units vs proximal-first, 0 units, P = .048), platelets (arch-first, 4 units vs proximal-first, 2 units, P = .003), and cryoprecipitates (arch-first, 2 units vs proximal-first, 1 unit, P = .024). Operative mortality and major morbidities were higher in the arch-first group (57.9% vs 11.5%, P = .001). One-year survival was comparable (arch-first, 89.5% ± 7.0% vs proximal-first, 92.0% ± 5.5%, P = .739). Distal intervention was successfully performed in 5 patients (endovascular, N = 3, and open repair, N = 2). Conclusions: Zone 2 arch repair using the proximal-first technique for acute type A aortic dissection repair yields shorter lower-body ischemic time with a warmer core temperature, resulting in shorter cardiopulmonary bypass time, less blood product use, and fewer morbidities when compared with the arch-first technique.

4.
Ann Thorac Surg ; 116(1): 43-50, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36653324

RESUMEN

BACKGROUND: There is paucity of data regarding reoperation after acute type A aortic dissection (ATAD) repair. METHODS: From October 2006 to March 2022, 75 patients received 123 reoperations after ATAD (proximal, n = 17; distal, n = 103; and both, n = 3) utilizing redo sternotomy (RS, n = 68), left thoracotomy (LT, n = 44), and endovascular approach (TEVAR, n = 11). The axillary artery cannulation was utilized in 97.1% of the RS cases. A classic elephant trunk technique was used as a 2-staged procedure for distal pathology. Most LT repairs (95.5%) were completed above the celiac axis. RESULTS: Index ATAD repairs were predominantly ascending/hemiarch repair (73.3%). The median duration from the index repair was 2.0 years. Most reoperations were elective procedures (82.1%). Hospital mortality was 2.4% (RS, 1.5%; LT, 4.5%; TEVAR, 0%), and the stroke rate was 1.6%. There was no spinal cord ischemia. The 5-year overall survival and freedom from aortic mortality or procedure were 85.2% ± 5.6% and 80.6% ± 6.1%, respectively. There were 7 distal reinterventions (prior TEVAR, n = 3; prior LT, n = 4). Two patients required LT repair after prior TEVAR and 3 patients received infrarenal aortic repair after prior LT repair. Computed tomography after completion of the distal repair (n = 45) showed an increase of distal aorta at each level as follows: celiac axis 1.2 mm/y; renal artery 1.0 mm/y; and terminal aorta 1.2 mm/y. CONCLUSIONS: Reoperation after ATAD repair can be safely performed as an elective procedure at experienced centers. Staged distal interventions utilizing classic elephant trunk insertion and open repair above the celiac axis showed durable outcomes.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Reoperación , Implantación de Prótesis Vascular/métodos , Factores de Riesgo , Disección Aórtica/cirugía , Aorta Torácica/cirugía , Procedimientos Endovasculares/métodos , Aorta Abdominal/cirugía , Resultado del Tratamiento , Aneurisma de la Aorta Torácica/cirugía , Estudios Retrospectivos
5.
Catheter Cardiovasc Interv ; 101(1): 180-186, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36478154

RESUMEN

BACKGROUND: Paravalvular regurgitation (PVR) may be missed intraoperatively with transthoracic echocardiography (TTE) guided minimalist TAVR. We sought to determine the incidence and echocardiographic distribution of PVR missed on intra-op TTE, but detected on predischarge TTE. METHODS: From July 2015 to 2020, 475 patients with symptomatic severe native aortic stenosis underwent TTE-guided minimalist TAVR. Missed PVR was defined as predischarge PVR that was ≥1 grade higher than the corresponding intra-op PVR severity. PVR was classified as anterior or posterior on the four standard TTE views; parasternal short-axis (PSAX), parasternal long-axis (PLAX), apical 3-chamber (A3C), and 5-chamber (A5C). Location-specific risk of missed PVR was then determined. RESULTS: Mild or greater PVR was seen in 55 (11.5%) cases intra-op and 91 (19.1%) at predischarge, with no severe PVR. Among the 91 patients with ≥mild predischarge PVR, missed PVR was present in 42 (46.2%). Compared to the corresponding anterior jets, missed PVR rate was significantly higher for posterior jets in PLAX (62.5% vs. 25.0%, p = 0.005), A5C (56.9% vs. 25.0%, p = 0.009), PSAX (66.7% vs. 24.3%, 0.001), but not A3C (58.5% vs. 40.0%, p = 0.28). CONCLUSIONS: Intraoperative TTE-guided minimalist TAVR either misses nearly half of ≥mild PVR or underestimates PVR by ≥1 grade when compared to predischarge TTE. Posterior PVR jets are more likely to be missed. Transesophageal echo guidance may help minimize missing PVR. Further studies are warranted.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/epidemiología , Insuficiencia de la Válvula Aórtica/etiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Incidencia , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Ecocardiografía/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Índice de Severidad de la Enfermedad
6.
Ann Thorac Surg ; 114(4): 1341-1347, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35292261

RESUMEN

BACKGROUND: This study seeks to assess the outcomes of direct axillary artery (AX) cannulation for thoracic aortic surgery. METHODS: From October 2009 to November 2021 direct AX cannulation was planned in 515 patients for thoracic aortic pathology. An important aspect of our technique is that the cannula is not inserted deeper than 3 cm. AX cannulation-related events included shift of cannulation site from the initial site, vascular injury, and iatrogenic dissection. RESULTS: Half of the patients had acute type A dissection (ATAD). An angled cannula was used in 442 patients and a straight cannula in 73 patients (14.2%) after August 2020. A previously cannulated AX was reused in 36 patients (7.0%). Mortality and stroke rates were 5.4% (ATAD vs non-ATAD: 8.0% vs 2.8%, P = .008) and 2.7% (ATAD vs non-ATAD: 4.6% vs 0.8%, P = .034), respectively. AX cannulation-related events were observed in 2.7% of patients. There was no difference in the vascular injury rate between ATAD and non-ATAD cases (1.6% vs 0.4%, respectively; P = .385), between different cannula types (angled vs straight: 0.9% vs 1.4%, P = 1.00), or between primary and redo AX cannulation cases (0.8% vs 2.8%, respectively; P = .791). On multidetector computed tomography analysis using automated 3-dimensional images, the mean distance from the thoracoacromial artery to the vertebral artery on the right and left sides was 8.70 cm and 8.69 cm, respectively. CONCLUSIONS: Direct AX cannulation for thoracic aortic repair is safe and carries a low rate of vascular injury, especially in elective cases. Our direct cannulation technique, which includes not inserting a cannula deeper than 3 cm, seems to be safe in not occluding the vertebral artery.


Asunto(s)
Arteria Axilar , Lesiones del Sistema Vascular , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Cánula , Puente Cardiopulmonar , Cateterismo/métodos , Humanos , Estudios Retrospectivos , Resultado del Tratamiento , Lesiones del Sistema Vascular/etiología
9.
Ann Thorac Surg ; 113(2): 569-576, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33857494

RESUMEN

BACKGROUND: This study reviews the outcomes of our reoperative total arch repair technique using a trifurcated graft and selective antegrade cerebral perfusion. METHODS: Fifty patients underwent reoperative total arch repair from January 2005 to September 2020, with either a one-stage repair (n = 9) or two-stage repair (n = 41). The two-stage technique includes minimal dissection of the mediastinal structures, an arch-first technique using a trifurcated graft, and construction of a classical elephant trunk through a partial transverse incision distally in the old graft or in the aorta just distal to the old graft. RESULTS: The median age was 63 years. Chronic dissection was the most frequent indication (88%), and 98% had undergone a previous proximal aortic repair at a median interval of 3 years. The median cardiopulmonary bypass, myocardial ischemic, selective antegrade cerebral perfusion, and lower body circulatory arrest times were 226, 103, 97, and 98 minutes, respectively. The minimum nasopharyngeal and bladder temperature were 16.5°C and 20.0°C, respectively. Operative mortality was 2%, the incidence of stroke was 2%, and the incidence of spinal cord injury was 0%. Stage II repair was performed in 37 patients (open, 33 patients; endovascular, 4 patients), with 2 mortalities and no spinal cord injury. The median duration between stage I and II was 63 days. Survival and aortic event free rates at 3 years were 88.4% ± 4.9%, and 89.8% ± 5%, respectively. CONCLUSIONS: We report a reoperative total arch repair technique that minimizes dissection of the cardiac structures, simplifies the distal anastomosis, and protects vital organs, such as the brain, heart, and spinal cord.


Asunto(s)
Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/métodos , Circulación Cerebrovascular/fisiología , Perfusión/métodos , Reoperación/métodos , Anciano , Anastomosis Quirúrgica/métodos , Disección Aórtica/mortalidad , Aneurisma de la Aorta Torácica/mortalidad , Femenino , Mortalidad Hospitalaria/tendencias , Humanos , Hipotermia Inducida , Masculino , Persona de Mediana Edad , New York/epidemiología , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo
10.
ASAIO J ; 68(2): e19-e21, 2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-33883504

RESUMEN

We describe a technique for insertion of the Impella RP device that does not require fluoroscopy. Venous cannulation was performed via the superior vena cava and femoral vein percutaneously. After right atriotomy, the Impella RP is percutaneously inserted and advanced to the right atrium under transesophageal echocardiography guidance. Next, via a longitudinal 2 cm incision in the main pulmonary artery (PA), a large C-shaped clamp is advanced retrograde through the pulmonic and tricuspid valves into the right atrium. The pigtail portion is grasped, pulled through to the main PA, and the device is positioned in the PA under direct vision.


Asunto(s)
Ecocardiografía Transesofágica , Vena Cava Superior , Vena Femoral , Fluoroscopía , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía
11.
J Am Soc Echocardiogr ; 35(1): 77-85, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34311062

RESUMEN

BACKGROUND: Textbook depictions of the mitral valve (MV) often illustrate it as composed of a single nonscalloped anterior leaflet, with the posterior leaflet having three symmetric and evenly spaced scallops. However, common variations in this anatomy have been noted in autopsy series for decades. Improved cardiac imaging with three-dimensional transesophageal echocardiography (TEE) now affords the ability to detect variations in scallop anatomy in vivo. The aims of this study were to catalog variations in mitral anatomy and to examine for association with mitral regurgitation in patients referred for clinical three-dimensional TEE. METHODS: Three-dimensional transesophageal echocardiographic images of the MV from 107 subjects were reviewed for MV variations. Three-dimensional analysis software was used to characterize mitral leaflet anatomy and assess the relative sizes of posterior leaflet scallops. RESULTS: Variations from the classic MV configuration were seen in 58.9%. Symmetric variations in the posterior leaflet (dominant P2 scallop, accessory P2 scallop, absent P2 scallop, and dichotomous P2 scallop) were seen in 33.6% of the study group. Asymmetric variants in the posterior leaflet (fused P1 and P2, fused P2 and P3, commissural scallop, accessory scallops, dichotomous P1 or P3, and dominant P2 or P3) were seen in 24.3%. Indentations or folds in the anterior leaflet were noted in 5.6%. Leaflet variations were not associated with patient demographics, indication for TEE, mitral regurgitation, mitral annular dimensions, or Carpentier class. CONCLUSIONS: Mitral leaflet morphologic variants were well characterized using three-dimensional TEE. Variants are common and were present with a frequency consistent with autopsy series. Mitral scallop variations were not associated with mitral regurgitation.


Asunto(s)
Ecocardiografía Tridimensional , Insuficiencia de la Válvula Mitral , Prolapso de la Válvula Mitral , Pectinidae , Animales , Ecocardiografía Transesofágica , Humanos , Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/diagnóstico por imagen
12.
Ann Thorac Surg ; 114(1): e67-e70, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-34710384

RESUMEN

We report a simplified zone 2 arch repair using a trifurcated graft for acute type A aortic dissection. The right axillary artery is cannulated. After completion of proximal aortic repair using a 1-branched graft, a trifurcated graft is anastomosed to the ascending graft just above the proximal suture line or coronary buttons in case of Bentall procedure. Distal aortic anastomosis is performed at the zone 2 level under unilateral antegrade cerebral perfusion. Full cardiopulmonary bypass flow is resumed via the right axillary artery and ascending graft using both Y-shaped arterial limbs. The left common carotid and innominate arteries are sequentially anastomosed.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Disección Aórtica/cirugía , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Arteria Axilar/cirugía , Implantación de Prótesis Vascular/métodos , Tronco Braquiocefálico/cirugía , Humanos , Perfusión
13.
Ann Thorac Surg ; 113(4): 1183-1190, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34052222

RESUMEN

BACKGROUND: This study assessed the safety of direct axillary artery (AX) cannulation for acute type A dissection (ATAD) repair, including the impact of innominate artery dissection (IAD). METHODS: Of 281 consecutive patients who underwent ATAD repair from 2007 to 2020, preoperative computed tomography was available in 200 (IAD, n = 101; non-IAD, n = 99). IAD with compromised true lumen was defined as dissection in which the false lumen was greater than 50% of the IA diameter (n = 75 of 101). RESULTS: AX cannulation was attempted in 188 patients (94.0%), with a 1.6% vascular injury rate (3 patients), comprising bypass to the distal AX in 2 patients and local dissection in 1 patient. Deep hypothermic circulatory arrest was used for the distal repair in 89.5% of patients. Right AX cannulation was used in 80.2% of patients with IAD and in 88.9% without IAD (P = .075). Patients with IAD had more cerebral (21.8% vs 5.1%, P = .001) and arm malperfsion (11.9% vs 4.0%, P = .075). Operative death and stroke were comparable between non-IAD (8.1% vs 7.9%, P = 1.00) and IAD (4.0% vs 5.3%, P = .689) groups. The right AX was successfully used in 77.3% of IAD patients with a compromised true lumen, with comparable hospital outcomes to noncompromised IAD patients. Upper extremity malperfusion, multiorgan malperfusion, low ejection fraction, and female sex were predictors for noncannulation of the right AX. CONCLUSIONS: Routine direct AX cannulation strategy is safe in ATAD repair. Right AX cannulation can be used in most patients with IAD, even with a compromised true lumen, with low mortality, stroke, and vascular injury rates.


Asunto(s)
Disección Aórtica , Accidente Cerebrovascular , Lesiones del Sistema Vascular , Disección Aórtica/etiología , Disección Aórtica/cirugía , Arteria Axilar , Tronco Braquiocefálico/cirugía , Puente Cardiopulmonar , Cateterismo/métodos , Femenino , Humanos , Accidente Cerebrovascular/etiología , Resultado del Tratamiento , Lesiones del Sistema Vascular/etiología
14.
JTCVS Tech ; 5: 62-71, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34318110

RESUMEN

OBJECTIVE: To review the outcomes of axillary artery (AX) and femoral artery (FA) cannulation for veno-arterial extracorporeal membraneous oxygenation (VA-ECMO). METHODS: From 2009 to 2019, 371 patients who were supported with VA-ECMO for cardiogenic shock were compared based on the arterial cannulation site: AX (n = 218) versus FA (n = 153). RESULTS: Patients in the AX group were older (61 years vs 58 years, P = .011), had a greater prevalence of peripheral vascular disease (13.8% vs 5.2%, P = .008), and were less likely to have undergone cardiopulmonary resuscitation preoperatively (18.8% vs 36.6%, P < .001). Other characteristics were similar between groups, as were in-hospital outcomes, including survival to discharge (60.6% vs 56.9%), cerebrovascular accidents (12.4% vs 10.5%), cannulation-related bleeding (15.1% vs 17%), and length of VA-ECMO support (6 days). The incidence of leg ischemia (6.9% vs 15.7%, P = .006), limb ischemia related to VA-ECMO cannulation (0% vs 10.5%), the need to switch the cannulation site (4.6% vs 14.7%), and wound complications (WCs; 2.8% vs 15%) including infection and additional procedure were significantly greater in the FA group (P < .001). In multiple logistic regression analysis, FA cannulation and primary graft failure after heart transplantation were independent risk factors for cannulation-related WC. In subgroup analysis among patients with primary graft failure, WCs were more prevalent in FA cannulation (3.6% vs 39.1%, P = .001). CONCLUSIONS: AX cannulation for VA-ECMO is a safe and effective alternative to FA cannulation. It can be considered especially for patients with limited groin access, peripheral vascular disease, or for primary graft failure after heart transplant.

15.
J Thorac Cardiovasc Surg ; 162(4): 1070-1071, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-32387165
16.
Ann Thorac Surg ; 110(6): e545-e547, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32565088

RESUMEN

We report our technique for left ventricular assist device insertion that is useful in patients with patent coronary artery bypass grafts or mediastinal adhesions from other previous surgeries. An inverted-T upper hemisternotomy is made at the level of the second or third intercostal space, and with the left sternal section retracted, dissection is carried along the chest wall into the left pleural space. The device is implanted in the left ventricular apex via a left thoracotomy in the fifth or sixth intercostal space. The outflow graft is routed through the left pleural space and anastomosed to the ascending aorta.


Asunto(s)
Puente de Arteria Coronaria , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Implantación de Prótesis/métodos , Esternotomía/métodos , Toracotomía/métodos , Insuficiencia Cardíaca/etiología , Humanos
17.
Am J Cardiol ; 127: 120-127, 2020 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-32402487

RESUMEN

With aging population and preponderance of severe aortic stenosis occurring in elderly patients, the number of transcatheter aortic valve implantations (TAVI) performed in the elderly are growing. Frailty is common in the elderly and is known to be associated with worse outcomes. We aimed to evaluate the impact of frailty on hospital readmissions rates after TAVI. We used the 2016 Nationwide Readmission Database and categorized patients who underwent TAVI low, intermediate, and high frailty status. The primary outcome was 6-months readmission rates across the 3 frailty categories. Secondary outcomes included causes of readmissions, in-hospital mortality and cost of care. STATA 16.0 was used for survey-specific statistical tests. Of 20,504 patients who underwent TAVI, 58.9% were low-, 39.6% were intermediate-, and 1.5% were in the high-frailty group. Overall in-hospital mortality was 1.9% (n = 396), and was 0.6%, 3.3%, and 16.8% (p <0.01) with increasing frailty. Of the 20,108 patients who survived to discharge, 6,427 (32%) patients were readmitted within 6-months after TAVI. Readmission rates increased across the categories from 27.9% in low, 37.6% in intermediate and 51.1% in high frailty group (p <0.01). While cardiac causes (mostly heart failure) were the predominant readmission etiologies across frailty categories (low: 51.2%, intermediate: 34.1%, high: 27.2%), rates of infectious and injury-related readmissions increased (low: 11%, intermediate: 30%, high: 45%). Mortality during readmissions also worsened from 0.8%, 5.3%, and 8.5% (p <0.01). Over 40% of patients undergoing TAVI were of intermediate-high frailty. In conclusion, an increasing frailty was associated with significantly worse postprocedure mortality, readmissions, and related mortality.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Fragilidad/complicaciones , Recursos en Salud/estadística & datos numéricos , Readmisión del Paciente/tendencias , Complicaciones Posoperatorias/epidemiología , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/mortalidad , Bases de Datos Factuales , Femenino , Estudios de Seguimiento , Fragilidad/mortalidad , Mortalidad Hospitalaria/tendencias , Humanos , Masculino , New York/epidemiología , Estudios Retrospectivos , Tasa de Supervivencia/tendencias , Factores de Tiempo
18.
JACC Cardiovasc Interv ; 13(9): 1030-1042, 2020 05 11.
Artículo en Inglés | MEDLINE | ID: mdl-32192985

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the impact of initial deployment orientation of SAPIEN 3, Evolut, and ACURATE-neo transcatheter heart valves on their final orientation and neocommissural overlap with coronary arteries. BACKGROUND: Coronary artery access and redo transcatheter aortic valve replacement (TAVR) following initial TAVR may be influenced by transcatheter heart valve orientation. In this study the impact of transcatheter heart valve deployment orientation on commissural alignment was evaluated. METHODS: Pre-TAVR computed tomography and procedural fluoroscopy were analyzed in 828 patients who underwent TAVR (483 SAPIEN 3, 245 Evolut, and 100 ACURATE-neo valves) from March 2016 to September 2019 at 5 centers. Coplanar fluoroscopic views were coregistered to pre-TAVR computed tomography to determine commissural alignment. Severe overlap between neocommissural posts and coronary arteries was defined as 0° to 20° apart. The SAPIEN 3 had 1 commissural post crimped at 3, 6, 9, and 12 o'clock. The Evolut "Hat" marker and ACURATE-neo commissural post at deployment were classified as center back (CB), inner curve (IC), outer curve (OC), or center front (CF) and matched with final orientation. RESULTS: Initial SAPIEN 3 crimped orientation had no impact on commissural alignment. Evolut "Hat" at OC or CF at initial deployment had less severe overlap than IC or CB (p < 0.001) against the left main (15.7% vs. 66.0%) and right coronary (7.1% vs. 51.1%) arteries. Tracking Evolut "Hat" at OC of the descending aorta (n = 107) improved OC at deployment from 70.2% to 91.6% (p = 0.002) and reduced coronary artery overlap by 36% to 60% (p < 0.05). ACURATE-neo commissural post at CB or IC during deployment had less coronary artery overlap compared to CF or OC (p < 0.001), with intentional alignment successful in 5 of 7 cases. CONCLUSIONS: This is the first systematic evaluation of commissural alignment in TAVR. More than 30% to 50% of cases had overlap with 1 or both coronary arteries. Initial SAPIEN 3 orientation had no impact on alignment, but specific initial orientations of Evolut and ACURATE improved alignment. Optimizing valve alignment to avoid coronary artery overlap will be important in coronary artery access and redo TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Vasos Coronarios/diagnóstico por imagen , Prótesis Valvulares Cardíacas , Tomografía Computarizada Multidetector , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Femenino , Fluoroscopía , Humanos , Masculino , Proyectos Piloto , Valor Predictivo de las Pruebas , Diseño de Prótesis , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Estados Unidos
19.
Am J Cardiol ; 125(8): 1222-1229, 2020 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-32093955

RESUMEN

New persistent left bundle branch block (NP-LBBB) has been associated with adverse outcomes after TAVI but few predictors thus far reported. We sought to identify predictors of NP-LBBB after TAVI with EvolutR/PRO (ER/EP). From 1/2016 to 4/2019, 544 patients from 2 centers underwent TAVI with Evolut (54% ER, 46% EP) for severe native aortic stenosis. Patients with previous LBBB and pacemaker were excluded. Aortic root analysis was performed using 3Mensio Valves Software and membranous septal length (MSL) was determined using the standard coronal view. Clinical, anatomic and procedural characteristics of 396 Evolut were analyzed and predictors of NP-LBBB were identified. Valve Academic Research Consortium-2 outcomes were reported. At discharge, NP-LBBB was seen in 76(19.2%) patients. NP-LBBB in Evolut was associated with implant depth at left coronary cusp (p = 0.004) and 34 mm ER (p = 0.026). Independent predictors of NP-LBBB in Evolut were shorter MSL (odds ratio [OR] = 0.82 per mm septum, 95% confidence interval [CI] = 0.68 to 0.98,p = 0.030), left ventricular outflow tract (LVOT) eccentricity (OR = 1.04 per %, 95% CI = 1.01 to 1.06,p = 0.002), implant depth at noncoronary cusp (NCC) (OR = 1.28 per mm ventricular, 95% CI = 1.11 to 1.48,p = 0.001) and annular perimeter oversizing ≥20% (OR = 2.38, 95% CI = 1.20 to 4.72, p = 0.013). On ROC curve analysis, MSL ≤6.5 mm, NCC depth ≥3 mm and LVOT eccentricity ≥35% were optimal threshold values to predict NP-LBBB. In Conclusion, shorter MSL, LVOT eccentricity, annular oversizing and deeper implant depth are novel predictors of NP-LBBB in Evolut TAVI. Preprocedural CT assessment of aortic root anatomy may help identify patients at risk for NP-LBBB. In such patients, modifying procedural factors such as higher implant and less annular oversizing may reduce the risk of NP-LBBB. Further evaluation of our hypothesis is warranted.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/anatomía & histología , Bloqueo de Rama/epidemiología , Ventrículos Cardíacos/anatomía & histología , Complicaciones Posoperatorias/epidemiología , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Tabique Interventricular/anatomía & histología , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Toma de Decisiones Clínicas , Ecocardiografía , Femenino , Prótesis Valvulares Cardíacas , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Tomografía Computarizada Multidetector , Tamaño de los Órganos , Factores de Riesgo , Tabique Interventricular/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...