Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Magn Reson Imaging ; 40(3): 674-81, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24214467

RESUMEN

PURPOSE: To determine whether readout-segmented echo-planar diffusion imaging (RESOLVE) improves separation of malignant versus benign lesions compared to standard single-shot echo-planar imaging (ss-EPI) on BI-RADS 4/5 lesions detected on breast magnetic resonance imaging (MRI). MATERIALS AND METHODS: Consecutive 3T breast MRI studies with BI-RADS 4/5 designation and subsequent biopsy or benign mastectomy were retrospectively identified. Freehand regions of interest (ROIs) were drawn on lesions and also on normal background fibroglandular tissue for comparison. Lesion-to-background contrast was evaluated by normalizing signal intensity of the lesion ROI by the normal background tissue ROI at b = 800. Statistical analysis used the Mann-Whitney/Wilcoxon rank-sum test for unpaired and Wilcoxon signed-rank for paired comparisons. RESULTS: Of 38 lesions in 32 patients, 10 were malignant. Lesion-to-background contrast was higher on RESOLVE than ss-EPI (1.80 ± 0.71 vs. 1.62 ± 0.63, P = 0.03). Mean apparent diffusion coefficient (ADC) was the same or lower on RESOLVE than ss-EPI, and this effect was largest in malignant lesions (RESOLVE 0.90 ± 0.13; ss-EPI 1.00 ± 0.13; median difference -0.10 (95% confidence interval [CI]: -0.17, -0.02) × 10(-3) mm(2) /sec; P = 0.014). By either diffusion method, there was a statistically significant difference between benign and malignant mean ADC (P < 0.001). CONCLUSION: Increased lesion-to-background contrast and improved separation of benign from malignant lesions by RESOLVE compared to standard diffusion suggests that RESOLVE may show promise as an adjunct to clinical breast MRI.


Asunto(s)
Neoplasias de la Mama/patología , Imagen de Difusión por Resonancia Magnética/métodos , Adulto , Anciano , Anciano de 80 o más Años , Biopsia , Medios de Contraste , Diagnóstico Diferencial , Imagen Eco-Planar , Femenino , Gadolinio DTPA , Humanos , Interpretación de Imagen Asistida por Computador , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad
2.
Radiology ; 224(3): 896-904, 2002 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-12202730

RESUMEN

The purpose of the study was to implement a three-dimensional (3D) magnetic resonance (MR) angiographic technique with acquisition times on the order of 800 msec with use of a spoiled gradient-echo pulse sequence (repetition time, 1.60 msec; echo time, 0.65 msec) and bolus intravenous injection of contrast material doses as small as 6 mL. High-spatial-resolution conventional MR angiography performed with 30 mL of gadopentetate dimeglumine was the reference standard. As implemented, subsecond 3D MR angiography allowed temporal sampling that was rapid enough to depict short-lived processes, as illustrated in patients with shunts and dissections. With small contrast material doses and subsecond frame rates, it is also possible to measure pulmonary arteriovenous circulation times with this 3D MR angiographic technique.


Asunto(s)
Angiografía por Resonancia Magnética/métodos , Tórax/anatomía & histología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Enfermedades de la Aorta/diagnóstico , Medios de Contraste/administración & dosificación , Femenino , Gadolinio DTPA/administración & dosificación , Cardiopatías/diagnóstico , Humanos , Enfermedades Pulmonares/diagnóstico , Masculino , Persona de Mediana Edad , Circulación Pulmonar
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...