Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Rev Cardiovasc Med ; 25(8): 305, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39228483

RESUMEN

Atrial high-rate episodes (AHREs) and subclinical atrial fibrillation (AF) are frequently registered in asymptomatic patients with cardiac implantable electronic devices (CIEDs) and insertable cardiac monitors (ICMs). While an increased risk of thromboembolic events (e.g., stroke) and benefits from anticoagulation have been widely assessed in the setting of clinical AF, concerns persist about optimal clinical management of subclinical AF/AHREs. As a matter of fact, an optimal threshold of subclinical episodes' duration to predict stroke risk is still lacking and recently published randomized clinical trials assessing the impact of anticoagulation on thromboembolic events in this specific setting have shown contrasting results. The aim of this review is to summarize current evidence regarding classification and clinical impact of subclinical AF/AHREs and to discuss the latest evidence regarding the potential benefit of anticoagulation in this setting, highlighting which clinical questions are still unanswered.

2.
J Cardiovasc Med (Hagerstown) ; 20(3): 114-121, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30575601

RESUMEN

INTRODUCTION: Implantable cardioverter-defibrillator (ICD) alarm systems are an important means of monitoring device functioning. The aim of this study was to compare the ability of patients with sense two types of device alert systems: an audible alert and a vibratory alarm. METHODS: The ability to recognize the alarms was assessed in three alarm tests performed in a series of consecutive ICD patients enrolled during routine outpatient device follow-up. To avoid overestimating the rate of patients able to sense the alarm, the first test was performed without forewarning. Subsequently, the second test was performed after the patients had been forewarned. Finally, to assess the learning effect of a demonstration test, a third test was performed, again without forewarning. RESULTS: A total of 528 patients (65.4 ±â€Š14.4 years, 74.6% male) were enrolled: 347 (65.7%) with an audible alert-endowed device and 181 (34.3%) with a vibratory alarm-endowed device. When emitted without warning, the alarms were sensed by 72.4% of patients. When patients were forewarned, the probability of sensing the alarms rose to 92.5% (P < 0.001). In both cases, the vibratory alarm was more likely to be sensed than the audible alert (77.3 vs. 67.7% in the first case; 96.1 vs. 87.9% in the second case; all P < 0.05). CONCLUSION: ICD alarms emitted in an outpatient setting are sensed by a large proportion of patients, but not by all. Training patients by means of demonstration tests significantly increases the rate of patients who recognize the alarm. Vibratory alarm seems to be more effective than audible alert.


Asunto(s)
Estimulación Acústica , Alarmas Clínicas , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Estimulación Física , Falla de Prótesis , Anciano , Percepción Auditiva , Cardioversión Eléctrica/efectos adversos , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Umbral Sensorial , Detección de Señal Psicológica , Vibración
3.
Europace ; 18(9): 1374-82, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26612878

RESUMEN

AIMS: It is not known whether heart failure (HF) patients with prolonged QRS who undergo cardiac resynchronization therapy combined with a defibrillator (CRT-D) have a prognostic advantage over HF patients with narrow QRS (therefore without indication for CRT) treated with an implantable cardioverter defibrillator (ICD) only. The aim of this study was to compare the long-term mortality of a group of HF patients with prolonged QRS receiving CRT-D with that of a similar group of patients with narrow QRS receiving ICD only. METHODS AND RESULTS: A total of 312 patients (mean age 66 ± 13 years; 84% male, mean left ventricular ejection fraction 25 ± 4%, mean New York Heart Association class 2.6 ± 0.5) were included in the analysis. Of these, 138 with a QRS complex duration ≥120 ms received a CRT-D. During follow-up, the time and cause of death were assessed. During a median follow-up of 46 months, CRT-D patients showed significantly lower overall mortality (P = 0.038). Compared with patients receiving ICD only, CRT-D patients showed lower HF mortality (P = 0.003). Coronary mortality, non-cardiac mortality, and sudden mortality were similar in both groups (all P > 0.05). A positive response to CRT was an independent predictor of reduced mortality on multivariate analysis (hazard ratio: 0.27; P = 0.047). CONCLUSION: In HF patients treated with ICD, the subgroup of patients with prolonged QRS who receive CRT-D displays better long-term survival than narrow QRS ICD recipients, owing to their reduced HF mortality.


Asunto(s)
Arritmias Cardíacas/terapia , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Sistema de Conducción Cardíaco/fisiopatología , Insuficiencia Cardíaca/terapia , Potenciales de Acción , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/fisiopatología , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/mortalidad , Causas de Muerte , Distribución de Chi-Cuadrado , Supervivencia sin Enfermedad , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Frecuencia Cardíaca , Humanos , Italia , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Análisis Multivariante , Modelos de Riesgos Proporcionales , Factores Protectores , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...