Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
2.
JACC Clin Electrophysiol ; 9(7 Pt 2): 1038-1047, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37495318

RESUMEN

BACKGROUND: High-power, short duration (HPSD) radiofrequency ablation (RFA) is a commonly used strategy for pulmonary vein isolation (PVI). OBJECTIVES: This study sought to compare HPSD with standard power, standard duration (SPSD) RFA in patients undergoing PVI. METHODS: Patients with paroxysmal or persistent (<1 year) atrial fibrillation (AF) were randomized to HPSD (50 W) or SPSD (25-30 W) RFA to achieve PVI. Outcomes assessed included time to achieve PVI (primary), left atrial dwell time, total procedure time, first-pass isolation, PV reconnection with adenosine, procedure complications including asymptomatic cerebral emboli (ACE), and freedom from atrial arrhythmias. RESULTS: Sixty patients (median age 66 years; 75% male) with paroxysmal (57%) or persistent (43%) AF were randomized to HPSD (n = 29) or SPSD (n = 31). Median time to achieve PVI was shorter with HPSD vs SPSD (87 minutes vs 126 minutes; P = 0.003), as was left atrial dwell time (157 minutes vs 180 minutes; P = 0.04). There were no differences in first-pass isolation (79% vs 76%; P = 0.65) or PV reconnection with adenosine (12% vs 20%; P = 0.26) between groups. At 12 months, recurrent atrial arrhythmias occurred less in the HPSD group compared with the SPSD group (n = 3 of 29 [10%] vs n = 11 of 31 [35%]; HR: 0.26; P = 0.027). There was a trend toward more ACE with HPSD RFA (40% HPSD vs 17% SPSD; P = 0.053). CONCLUSIONS: In patients undergoing AF ablation, HPSD compared with SPSD RFA results in shorter time to achieve PVI, greater freedom from AF at 12 months, and a trend toward increased ACE.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Masculino , Anciano , Femenino , Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Resultado del Tratamiento , Adenosina , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
3.
JACC Clin Electrophysiol ; 9(2): 219-228, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36858688

RESUMEN

BACKGROUND: The difference between the right ventricular (RV) apical stimulus-atrial electrogram (SA) interval during resetting of supraventricular tachycardia (SVT) versus the ventriculoatrial (VA) interval during SVT (ΔSA-VAapex) is an established technique for discerning SVT mechanisms but is limited by a significant diagnostic overlap. OBJECTIVES: This study hypothesized that the difference between the RV SA interval during resetting of SVTs versus the VA interval during SVTs (ΔSA-VA) would yield a more robust differentiation of atrioventricular nodal re-entrant tachycardia (AVNRT) from atrioventricular reciprocating tachycardia (AVRT) when using the RV basal septal stimulation (ΔSA-VAbase) as compared to the RV apical stimulation (ΔSA-VAapex). Moreover, it was predicted that the ΔSA-VAbase might distinguish septal from free wall accessory pathways (APs) effectively. METHODS: In this prospective study, 105 patients with AVNRTs (age 48 ± 20 years, 44% male) and 130 with AVRTs (age 26 ± 18 years, 54% male) underwent programmed ventricular extrastimuli delivered from both the RV basal septum and RV apex. The ΔSA-VA values were compared between the 2 sites. RESULTS: The ΔSA-VAbase was shorter than the ΔSA-VAapex during AVRT (44 ± 30 ms vs 58 ± 29 ms; P < 0.001), and the opposite occurred during AVNRT (133 ± 31 ms vs 125 ± 25 ms; P = 0.03). A ΔSA-VAbase of ≧85 milliseconds had a sensitivity of 97% and specificity of 96% for identifying AVNRT. Furthermore, a ΔSA-VAbase of 45-85 milliseconds identified AVRT with left free wall APs (sensitivity 86%, specificity 95%), 20-45 milliseconds for posterior septal APs (sensitivity 72%, specificity 96%), and <20 milliseconds for right free wall or anterior/mid septal APs (sensitivity 86%, specificity 98%). CONCLUSIONS: The ΔSA-VAbase during programmed ventricular extrastimuli produced a robust differentiation between AVNRT and AVRT regardless of the AP location with ≧85 milliseconds as an excellent cutoff point. This straightforward technique further allowed localizing 4 general AP sites.


Asunto(s)
Taquicardia por Reentrada en el Nodo Atrioventricular , Taquicardia Supraventricular , Tabique Interventricular , Humanos , Masculino , Adulto , Persona de Mediana Edad , Anciano , Niño , Adolescente , Adulto Joven , Femenino , Estudios Prospectivos , Ventrículos Cardíacos
4.
JACC Clin Electrophysiol ; 9(5): 611-619, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36752451

RESUMEN

BACKGROUND: Transseptal puncture is a necessary component of many electrophysiology and structural heart procedures. Improving this technique has broad ramifications for the overall efficiency and safety of these interventions. A new technology uses a specialized introducer wire to cross the septum with radiofrequency (RF) energy, eliminating the need for a transseptal needle and wire/needle exchanges. OBJECTIVES: This study sought to compare the efficacy and safety of an RF needle versus RF wire approach for transseptal puncture. METHODS: Individuals ≥18 years of age undergoing double transseptal puncture for atrial fibrillation or left atrial flutter ablation were randomized to a transseptal approach with either an RF needle or RF wire. The primary outcome was time to achieve first transseptal puncture. Secondary outcomes included second and combined transseptal puncture time, fluoroscopy time, number of equipment exchanges, and complications. RESULTS: A total of 75 participants were enrolled (36 RF needle, 39 RF wire). No crossovers occurred. Randomization to the RF wire resulted in a significant reduction in first transseptal time compared with the RF needle (median 9.2 [IQR: 5.7-11.2] minutes vs 6.9 [IQR: 5.2-8.4] minutes, P = 0.03). Second and combined transseptal times, and number of equipment exchanges, were also reduced with the RF wire. One participant in the RF needle group experienced transient atrioventricular block due to mechanical trauma from the sheath/dilator assembly. There were no complications in the RF wire group. CONCLUSIONS: The RF wire technique resulted in faster time to transseptal puncture and fewer equipment exchanges compared with an RF needle with no difference in complications.


Asunto(s)
Fibrilación Atrial , Atrios Cardíacos , Humanos , Diseño de Equipo , Fibrilación Atrial/cirugía , Agujas , Punciones/métodos
6.
Int J Cardiol ; 336: 60-66, 2021 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-34048856

RESUMEN

BACKGROUND: Idiopathic VA are traditionally considered benign, although occasional patients develop an ectopy-mediated cardiomyopathy (EMC). It is unclear whether patients with idiopathic VA in the absence of left ventricular (LV) dysfunction harbor a subclinical cardiomyopathy. We aim to assess for cardiomyopathic substrate in patients with idiopathic ventricular arrhythmias (VA) using imaging and electrophysiologic markers of early fibrosis. METHODS: Cardiac magnetic resonance (CMR) imaging and ventricular electroanatomic mapping was performed in 3 groups: patients undergoing ablation for idiopathic VA without (Group 1, n = 17) and with LV dysfunction (Group 2 [presumed EMC], n = 12) plus a control group undergoing ablation of supraventricular tachycardia (Group 3, n = 16). Global LV strain, T1 mapping and extended electrogram (EGM) characteristics were compared. RESULTS: Global strain was impaired in patients with presumed EMC (Group 2, p < 0.001). Native T1 times did not differ between groups, however patients in both idiopathic VA groups (Groups 1 and 2) had shorter post-contrast T1 times at 8 min compared to SVT controls (Group 3, p = 0.04). Similarly, the duration of the bipolar EGM was subtly prolonged in both Group 1 and 2 compared to Group 3 (p = 0.002). There were no between group differences in unipolar or bipolar voltage, the no. of bipolar EGM deflections or the maximal unipolar EGM dV/dt. CONCLUSION: Patients with idiopathic VAs and apparently structurally normal hearts may have subtle CMR and electrophysiologic changes similar in magnitude to that seen in frank presumed EMC, possibly suggestive of an occult cardiomyopathic process.


Asunto(s)
Cardiomiopatías , Ablación por Catéter , Taquicardia Ventricular , Disfunción Ventricular Izquierda , Arritmias Cardíacas/cirugía , Cardiomiopatías/diagnóstico por imagen , Ventrículos Cardíacos , Humanos , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/cirugía
7.
J Cardiovasc Electrophysiol ; 31(12): 3232-3242, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33107135

RESUMEN

INTRODUCTION: Permanent junctional reciprocating tachycardia (PJRT) is a rare supraventricular tachycardia (SVT), typically involving a single decremental posteroseptal accessory pathway (AP). METHODS: Four patients with long RP SVT underwent electrophysiology (EP) study and ablation. The cases were reviewed. RESULTS: Case 1 recurred despite 3 prior ablations at the site of earliest retrograde atrial activation during orthodromic reciprocating tachycardia (ORT). Mapping during a repeat EP study demonstrated a prepotential in the coronary sinus (CS). Ablation over the earliest atrial activation in the CS resulted in dissociation of the potential from the atrium during sinus rhythm. The potential was traced back to the CS os and ablated. Case 2 underwent successful ablation at 6 o'clock on the mitral annulus (MA). ORT recurred and successful ablation was performed at 1 o'clock on the MA. Case 3 had tachycardia with variation in both V-A and A-H intervals which precluded the use of usual maneuvers so we used simultaneous atrial and ventricular pacing and introduced a premature atrial contraction with a closely coupled premature ventricular contraction. Case 4 had had two prior atrial fibrillation ablations with continued SVT over a decremental atrioventricular bypass tract that was successfully ablated at 5 o'clock on the tricuspid annulus. A second SVT consistent with a concealed nodoventricular pathway was successfully ablated at the right inferior extension of the AV nodal slow pathway. CONCLUSION: We describe challenging cases of PJRT by virtue of complex anatomy, diagnostic features, and multiple arrhythmia mechanisms.


Asunto(s)
Ablación por Catéter , Taquicardia Reciprocante , Taquicardia Supraventricular , Nodo Atrioventricular , Electrocardiografía , Humanos , Taquicardia Reciprocante/diagnóstico , Taquicardia Reciprocante/cirugía , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirugía
8.
JACC Clin Electrophysiol ; 6(6): 711-721, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32553223

RESUMEN

OBJECTIVES: The aim of this study was to define normal ventricular electrographic characteristics in T1 mapping-validated normal patients using a contemporary contact force catheter. BACKGROUND: Reference values for human endocardial ventricular electrographic characteristics have not been defined using contemporary mapping equipment in patients without heart disease or ventricular arrhythmias. METHODS: Fourteen patients undergoing SVT ablation underwent mapping of the right ventricle and cardiac magnetic resonance imaging with T1 mapping. Electrograms (EGMs) from sites with >10 g of contact force from the right ventricular free wall (RVFW) and right ventricular septum (RVS) were analyzed. Values <5th percentile or >95th percentile were defined as abnormal. RESULTS: The median age was 27 years, 64% of patients were men, and the mean left ventricular ejection fraction was 60%. Native T1 values (mean 979 ms) of the study population were comparable with that of a normal volunteer population. Ninety-five percent of bipolar EGMs had <6 (RVFW) or <7 (RVS) deflections and duration <37 ms. Ninety-five percent of unipolar EGMs had a maximum dV/dt >0.23 mV/ms (RVFW) or >0.24 mV/ms (RVS). Ninety-five percent of unipolar EGMs had a peak-to-peak voltage >3.8 mV (RVFW) or >4.5 mV (RVS). CONCLUSIONS: In structurally normal hearts, the threshold for abnormal endocardial unipolar voltage in the RVFW (3.8 mV) is lower than that of the current standard (5.5 mV). The unipolar voltage characteristics of the RVS is distinct from that of the RVFW and left ventricle. This has implications for the detection of intramural or epicardial and especially midseptal scar.


Asunto(s)
Ventrículos Cardíacos , Taquicardia Ventricular , Adulto , Endocardio , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Volumen Sistólico , Función Ventricular Izquierda
9.
Heart Lung Circ ; 28(11): 1677-1682, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30392985

RESUMEN

BACKGROUND: To describe the performance and clinical outcomes of consecutive patients having a leadless pacemaker (LP) implanted at a single institution. METHODS: Clinical data and device parameters were prospectively collected on all patients undergoing LP implantation from November 2015 to April 2018. RESULTS: A total of 79 patients (52 male), median age of 78 years, was included. Leadless pacemaker implantation was successful in 76 patients (96%). Implantation failed in two patients due to excessive venous tortuosity and due to inadequate sensing in another. Seventy-three (73) patients (96%) had chronic atrial fibrillation and all had a Class I or II indication for pacing. Procedure time was 29minutes (IQR 21-43) and fluoroscopy time was 8minutes (IQR 5-13). The median R wave at implant was 11.2mV (IQR 6.9-15.0). The median capture threshold at 0.24ms was 0.5V (IQR 0.4-0.9) and impedance was 754Ω (IQR 680-880). Intraprocedural acute dislodgement occurred in one patient following cutting of the tether but successful snaring and reimplantation was performed. During a median follow-up of 355days (range 9-905), overall electrical performance has been excellent. No patients have been readmitted for device revision or complications. Five (5) patients (7%) died during follow-up from unrelated causes. CONCLUSIONS: Leadless pacemakers can be implanted safely and effectively in the majority of patients. Device electrical performance was excellent over a median follow-up of 12 months.


Asunto(s)
Fibrilación Atrial/terapia , Estimulación Cardíaca Artificial/métodos , Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/fisiopatología , Australia , Electrocardiografía , Diseño de Equipo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Prospectivos , Resultado del Tratamiento
10.
ACS Chem Neurosci ; 9(11): 2767-2773, 2018 11 21.
Artículo en Inglés | MEDLINE | ID: mdl-29763549

RESUMEN

In vivo positron emission tomography (PET) imaging of the γ-aminobutyric acid (GABA) receptor complex has been accomplished using radiolabeled benzodiazepine derivatives, but development of specific presynaptic radioligands targeting the neuronal membrane GABA transporter type 1 (GAT-1) has been less successful. The availability of new structure-activity studies of GAT-1 inhibitors and the introduction of a GAT-1 inhibitor (tiagabine, Gabatril) into clinical use prompted us to reinvestigate the syntheses of PET ligands for this transporter. Initial synthesis and rodent PET studies of N-[11C]methylnipecotic acid confirmed the low brain uptake of that small and polar molecule. The common design approach to improve blood-brain barrier permeability of GAT-1 inhibitors is the attachment of a large lipophilic substituent. We selected an unsymmetrical bis-aromatic residue attached to the ring nitrogen by a vinyl ether spacer from a series recently reported by Wanner and coworkers. Nucleophilic aromatic substitution of an aryl chloride precursor with [18F]fluoride was used to prepare the desired candidate radiotracer ( R, E/ Z)-1-(2-((4-fluoro-2-(4-[18F]fluorobenzoyl)styryl)oxy)ethyl)piperidine-3-carboxylic acid (( R, E/ Z)-[18F]10). PET studies in rats showed no brain uptake, which was not altered by pretreatment of animals with the P-glycoprotein inhibitor cyclosporine A, indicating efflux by Pgp was not responsible. Subsequent PET imaging studies of ( R, E/ Z)-[18F]10 in rhesus monkey brain showed very low brain uptake. Finally, to test if the free carboxylic acid group was the likely cause of poor brain uptake, PET studies were done using the ethyl ester derivative of ( R, E/ Z)-[18F]10. Rapid and significant monkey brain uptake of the ester was observed, followed by a slow washout over 90 min. The blood-brain barrier permeability of the ester supports a hypothesis that the free acid function limits brain uptake of nipecotic acid-based GAT-1 radioligands, and future radiotracer efforts should investigate the use of carboxylic acid bioisosteres.


Asunto(s)
Barrera Hematoencefálica/metabolismo , Encéfalo/metabolismo , Proteínas Transportadoras de GABA en la Membrana Plasmática/metabolismo , Inhibidores de Recaptación de GABA/metabolismo , Piperidinas/metabolismo , Radiofármacos/metabolismo , Miembro 1 de la Subfamilia B de Casetes de Unión a ATP/antagonistas & inhibidores , Animales , Encéfalo/diagnóstico por imagen , Ciclosporina/farmacología , Inhibidores Enzimáticos/farmacología , Ésteres/metabolismo , Radioisótopos de Flúor , Macaca mulatta , Permeabilidad , Piperidinas/síntesis química , Tomografía de Emisión de Positrones , Radiofármacos/síntesis química , Ratas , Estereoisomerismo , Tiagabina/metabolismo
11.
ALTEX ; 33(2): 149-66, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26863606

RESUMEN

Grouping of substances and utilizing read-across of data within those groups represents an important data gap filling technique for chemical safety assessments. Categories/analogue groups are typically developed based on structural similarity and, increasingly often, also on mechanistic (biological) similarity. While read-across can play a key role in complying with legislations such as the European REACH regulation, the lack of consensus regarding the extent and type of evidence necessary to support it often hampers its successful application and acceptance by regulatory authorities. Despite a potentially broad user community, expertise is still concentrated across a handful of organizations and individuals. In order to facilitate the effective use of read-across, this document aims to summarize the state-of-the-art, summarizes insights learned from reviewing ECHA published decisions as far as the relative successes/pitfalls surrounding read-across under REACH and compile the relevant activities and guidance documents. Special emphasis is given to the available existing tools and approaches, an analysis of ECHA's published final decisions associated with all levels of compliance checks and testing proposals, the consideration and expression of uncertainty, the use of biological support data and the impact of the ECHA Read-Across Assessment Framework (RAAF) published in 2015.


Asunto(s)
Seguridad Química/métodos , Sustancias Peligrosas/toxicidad , Animales , Bases de Datos Factuales , Humanos , Medición de Riesgo/métodos , Administración de la Seguridad/métodos , Toxicología/métodos , Incertidumbre
12.
J Cheminform ; 6: 34, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24987464

RESUMEN

BACKGROUND: Quantitative structure-activity (QSAR) models have enormous potential for reducing drug discovery and development costs as well as the need for animal testing. Great strides have been made in estimating their overall reliability, but to fully realize that potential, researchers and regulators need to know how confident they can be in individual predictions. RESULTS: Submodels in an ensemble model which have been trained on different subsets of a shared training pool represent multiple samples of the model space, and the degree of agreement among them contains information on the reliability of ensemble predictions. For artificial neural network ensembles (ANNEs) using two different methods for determining ensemble classification - one using vote tallies and the other averaging individual network outputs - we have found that the distribution of predictions across positive vote tallies can be reasonably well-modeled as a beta binomial distribution, as can the distribution of errors. Together, these two distributions can be used to estimate the probability that a given predictive classification will be in error. Large data sets comprised of logP, Ames mutagenicity, and CYP2D6 inhibition data are used to illustrate and validate the method. The distributions of predictions and errors for the training pool accurately predicted the distribution of predictions and errors for large external validation sets, even when the number of positive and negative examples in the training pool were not balanced. Moreover, the likelihood of a given compound being prospectively misclassified as a function of the degree of consensus between networks in the ensemble could in most cases be estimated accurately from the fitted beta binomial distributions for the training pool. CONCLUSIONS: Confidence in an individual predictive classification by an ensemble model can be accurately assessed by examining the distributions of predictions and errors as a function of the degree of agreement among the constituent submodels. Further, ensemble uncertainty estimation can often be improved by adjusting the voting or classification threshold based on the parameters of the error distribution. Finally, the profiles for models whose predictive uncertainty estimates are not reliable provide clues to that effect without the need for comparison to an external test set.

13.
J Chem Inf Model ; 49(9): 2013-33, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19702243

RESUMEN

One of the most important physicochemical properties of small molecules and macromolecules are the dissociation constants for any weakly acidic or basic groups, generally expressed as the pK(a) of each group. This is a major factor in the pharmacokinetics of drugs and in the interactions of proteins with other molecules. For both the protein and small molecule cases, we survey the sources of experimental pK(a) values and then focus on current methods for predicting them. Of particular concern is an analysis of the scope, statistical validity, and predictive power of methods as well as their accuracy.


Asunto(s)
Fenómenos Químicos , Animales , Humanos , Concentración de Iones de Hidrógeno , Modelos Moleculares , Proteínas/química , Proteínas/metabolismo , Teoría Cuántica , Electricidad Estática
14.
J Chem Inf Model ; 48(10): 2042-53, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18826209

RESUMEN

Realizing favorable absorption, distribution, metabolism, elimination, and toxicity profiles is a necessity due to the high attrition rate of lead compounds in drug development today. The ability to accurately predict bioavailability can help save time and money during the screening and optimization processes. As several robust programs already exist for predicting logP, we have turned our attention to the fast and robust prediction of pK(a) for small molecules. Using curated data from the Beilstein Database and Lange's Handbook of Chemistry, we have created a decision tree based on a novel set of SMARTS strings that can accurately predict the pK(a) for monoprotic compounds with R(2) of 0.94 and root mean squared error of 0.68. Leave-some-out (10%) cross-validation achieved Q(2) of 0.91 and root mean squared error of 0.80.


Asunto(s)
Preparaciones Farmacéuticas/química , Bibliotecas de Moléculas Pequeñas , Programas Informáticos , Algoritmos , Análisis por Conglomerados , Interpretación Estadística de Datos , Árboles de Decisión , Evaluación Preclínica de Medicamentos , Predicción , Cinética , Modelos Moleculares , Mapeo Peptídico , Análisis de Componente Principal , Reproducibilidad de los Resultados , Relación Estructura-Actividad , Descriptores
15.
J Chem Inf Model ; 48(7): 1379-88, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18588283

RESUMEN

Elimination of cytotoxic compounds in the early and later stages of drug discovery can help reduce the costs of research and development. Through the application of principal components analysis (PCA), we were able to data mine and prove that approximately 89% of the total log GI 50 variance is due to the nonspecific cytotoxic nature of substances. Furthermore, PCA led to the identification of groups of structurally unrelated substances showing very specific toxicity profiles, such as a set of 45 substances toxic only to the Leukemia_SR cancer cell line. In an effort to predict nonspecific cytotoxicity on the basis of the mean log GI 50, we created a decision tree using MACCS keys that can correctly classify over 83% of the substances as cytotoxic/noncytotoxic in silico, on the basis of the cutoff of mean log GI 50 = -5.0. Finally, we have established a linear model using least-squares in which nine of the 59 available NCI60 cancer cell lines can be used to predict the mean log GI 50. The model has R (2) = 0.99 and a root-mean-square deviation between the observed and calculated mean log GI 50 (RMSE) = 0.09. Our predictive models can be applied to flag generally cytotoxic molecules in virtual and real chemical libraries, thus saving time and effort.


Asunto(s)
Ensayos de Selección de Medicamentos Antitumorales , Almacenamiento y Recuperación de la Información , Línea Celular Tumoral , Árboles de Decisión , Humanos
16.
J Chem Inf Model ; 47(6): 2063-76, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17915856

RESUMEN

The NCI Developmental Therapeutics Program Human Tumor cell line data set is a publicly available database that contains cellular assay screening data for over 40 000 compounds tested in 60 human tumor cell lines. The database also contains microarray assay gene expression data for the cell lines, and so it provides an excellent information resource particularly for testing data mining methods that bridge chemical, biological, and genomic information. In this paper we describe a formal knowledge discovery approach to characterizing and data mining this set and report the results of some of our initial experiments in mining the set from a chemoinformatics perspective.


Asunto(s)
Bases de Datos Factuales , Antineoplásicos/química , Antineoplásicos/farmacología , Línea Celular Tumoral , Proliferación Celular/efectos de los fármacos , Evaluación Preclínica de Medicamentos , Regulación Neoplásica de la Expresión Génica/efectos de los fármacos , Humanos , Estructura Molecular , National Cancer Institute (U.S.) , Neoplasias/patología , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...