RESUMEN
The urine albumin (Alb)-to-creatinine (Crn) ratio (UACR) is a sensitive and early indicator of chronic kidney disease (CKD) and cardiorenal syndrome. This study developed a portable and wireless electrochemical-sensing platform for the sensitive and accurate determination of UACR. The developed platform consists of a carbon nanotube (CNT)-2,2'-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid)(ABTS)-based modified UACR sensor, a miniaturised potentiostat, a cup holder embedded with a magnetic stirrer and a smartphone app. The UACR sensing electrode is composed of two screen-printed carbon working electrodes, one screen-printed carbon counter electrode and a screen-printed AgCl reference electrode. The miniaturised potentiostat, which is controlled by the developed app, performs cyclic voltammetry and amperometry to detect Alb and Crn, respectively. Clinical trials of the proposed system by using spot urine samples from 30 diabetic patients indicate that it can accurately classify all three CKD risk statuses within 30 min. The high accuracy of our proposed sensing system exhibits satisfactory agreement with the commercial biochemical analyser TBA-25FR (Y = 0.999X, R2 = 0.995). The proposed UACR sensing system offers a convenient, reliable and affordable solution for personal mobile health monitoring and point-of-care urinalysis.
Asunto(s)
Albuminuria , Síndrome Cardiorrenal , Creatinina , Técnicas Electroquímicas , Sistemas de Atención de Punto , Insuficiencia Renal Crónica , Humanos , Insuficiencia Renal Crónica/orina , Insuficiencia Renal Crónica/diagnóstico , Creatinina/orina , Albuminuria/orina , Síndrome Cardiorrenal/orina , Síndrome Cardiorrenal/diagnóstico , Técnicas Biosensibles , Nanotubos de CarbonoRESUMEN
This study proposes a charge-mode neural stimulator for electrical stimulation systems that utilizes a capacitor-reuse technique with a residual charge detector and achieves active charge balancing simultaneously. The design is mainly used for epilepsy suppression systems to achieve real-time symptom relief during seizures. A charge-mode stimulator is adopted in consideration of the complexity of circuit design, the high voltage tolerance of transistors, and system integration requirements in the future. The residual charge detector allows users to understand the current stimulus situation, enabling them to make optimal adjustments to the stimulation parameters. On the basis of the information on actual stimulation charge, active charge balancing can effectively prevent the accumulation of mismatched charges on electrode impedance. The capacitor- and phase-reuse techniques help realize high integration of the overall stimulator circuit in consideration of the commonality of the use of a capacitor and charging/discharging phase in the stimulation circuit and charge detector. The proposed charge-mode neural stimulator is implemented in a TSMC 0.18 µm 1P6M CMOS process with a core area of 0.2127 mm2. Measurement results demonstrate the accuracy of the stimulation's functionality and the programmable stimulus parameters. The effectiveness of the proposed charge-mode neural stimulator for epileptic seizure suppression is verified through animal experiments.
Asunto(s)
Terapia por Estimulación Eléctrica , Neuronas , Convulsiones , Diseño de Equipo/instrumentación , Diseño de Equipo/métodos , Convulsiones/terapia , Humanos , Terapia por Estimulación Eléctrica/instrumentación , Terapia por Estimulación Eléctrica/métodosRESUMEN
A second-order voltage-controlled oscillator (VCO)-based continuous-time sigma-delta modulator (CTSDM) for current-sensing readout applications is proposed. Current signals from the sensor can directly be quantized by the proposed VCO-based CTSDM, which does not require any extra trans-impedance amplifiers. With the proportional-integral (PI) structure and a VCO phase integrator, the capability of second-order noise shaping is available to reduce the in-band quantization noise. The PI structure can be simply realized by a resistor in series with the integrating capacitor, which can reduce the architecture complexity and maintain the stability of the system. The current-steering digital-to-analog converter with tail and sink current sources is used on the feedback path for the subtraction of the current-type input signal. All the components of the circuit are scaling friendly and applicable to current-sensing readout applications in the Internet of Things (IoT). The proposed VCO-based CTSDM implemented in a 0.18-µm standard CMOS process has a measured signal-to-noise and distortion ratio (SNDR) of 74.6 dB at 10 kHz bandwidth and consumes 44.8 µw only under a supply voltage of 1.2 V, which can achieve a Figure-of-Merit (FoM) of 160.76 dB.
Asunto(s)
Amplificadores Electrónicos , Electricidad , Conversión Analogo-Digital , Relación Señal-Ruido , RetroalimentaciónRESUMEN
This work presents a third-order high-pass sigma-delta modulator (HPSDM) for biomedical signal acquisition. The operational amplifier (op-amp) sharing and noise-coupling techniques are adopted to reduce the required quantity of op-amps and add a noise-shaping order, which can achieve low power consumption and high resolution. A novel switched-capacitor architecture is proposed to suppress the increasing in-band noise and alleviate the circuit sensitivity to capacitor mismatch in the high-pass integrator. The proposed HPSDM was fabricated in a 0.18-µm standard CMOS process. Measurement results reveal that the proposed HPSDM has a signal-to-noise and distortion ratio (SNDR) of 75.26/74 dB in 200 Hz bandwidth and consumes 1.52/0.8 µW under 1.2/1 V supply voltage, which can achieve a peak Schreier Figure-of-Merit of 156.45/157.98 dB and a peak Walden FoM of 0.802/0.488 pJ/conv.
Asunto(s)
Amplificadores Electrónicos , Relación Señal-RuidoRESUMEN
Visitor-centered approaches have been widely discussed in the museum experience research field. One notable approach was suggested by Falk and Dierking, who defined museum visitor experience as having a physical, personal, and social context. Many studies have been conducted based on this approach, yet the interactions between personal and social contexts have not been fully researched. Since previous studies related to these interactions have focused on the face-to-face conversation of visitor groups, attempts to provide the social information contributed by visitors have not progressed. To fill this gap, we examined such interactions in collaboration with the Lee-Ungno Art Museum in South Korea. Specifically, we investigated the influence of individual visitors' social contextual information about their art museum experience. This data, which we call "visitor-based social contextual information" (VSCI), is the social information individuals provide-feedback, reactions, or behavioral data-that can be applied to facilitate interactions in a social context. The study included three stages: In Stage 1, we conducted an online survey for a preliminary investigation of visitors' requirements for VSCI. In Stage 2, we designed a mobile application prototype. Finally, in Stage 3, we used the prototype in an experiment to investigate the influence of VSCI on museum experience based on visitors' behaviors and reactions. Our results indicate that VSCI positively impacts visitors' museum experiences. Using VSCI enables visitors to compare their thoughts with others and gain insights about art appreciation, thus allowing them to experience the exhibition from new perspectives. The results of this novel examination of a VSCI application suggest that it may be used to guide strategies for enhancing the experience of museum visitors.
Asunto(s)
Comunicación , Museos , Humanos , República de Corea , Encuestas y CuestionariosRESUMEN
This work presents a portable wireless urine detection system which consists of an electrochemical readout application specific integrated circuit (ASIC) and a biosensor composed of 2, 2'-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid) and carbon nanotube (ABTS-CNT) for the detection of urine albumin-to-creatinine ratio (UACR). The ASIC includes a potentiostat, a digital circuitry and a power management circuit which can perform electrochemistry techniques with a dual-channel screen-printing carbon electrode (SPCE). Electrochemical experiments on the proposed biosensor (SPCE|ABTS-CNT|Nafion) have revealed promising sensing characteristics for creatinine and human serum albumin detection. Practical urine tests has demonstrated the capability of the proposed urine detection system for UACR detection with both the power-efficient readout ASIC and the ABTS-CNT biosensor. A user-friendly prototype has also been designed which can be useful for either personal health administrationor homecare.