Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Eur Heart J Cardiovasc Imaging ; 15(9): 987-95, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24662443

RESUMEN

AIMS: To investigate the incidence of incomplete stent apposition and to explore the impact of the presence of thrombus and protruding plaque after stent implantation on neointima formation at follow-up in ST-segment elevation myocardial infarction (STEMI) patients with serial optical frequency domain imaging (OFDI) investigations. METHODS AND RESULTS: In a multi-centre study, 141 patients with ST elevation myocardial infarction <12 h from onset were randomized to either PPCI with thrombectomy (TB) using an Eliminate catheter (TB: n = 71) or without TB (non-TB: n = 70). OFDI after drug-eluting stenting was performed using TERUMO OFDI system. Per protocol, at follow-up 49 patients segments were reimaged. At post-procedure and follow-up, there were no differences in stent and lumen areas between the two groups. At follow-up, per strut-level analysis, percentage of incompletely apposed struts was 0.42 ± 0.94 vs. 0.38 ± 0.77% (P = 0.76), and percentage of covered struts was 92.7 ± 7.2 vs. 94.4 ± 9.2% (P = 0.47) in the TB and non-TB groups, respectively. There was a positive correlation between intra-stent structure (ISS) volume at post-procedure and the neointima volume at 6-month follow-up (Pearson's r = 0.409, P = 0.04). Up to 12 months, there have been two and four patients having target vessel failure in the TB and in the non-TB groups, respectively. CONCLUSIONS: In patients with STEMI, there were no significant differences in OFDI parameters between TB and non-TB groups at both post-procedure and 6-month follow-up. However, ISS volume at post-procedure was positively associated with neointimal volume at 6-month follow-up.


Asunto(s)
Infarto del Miocardio/diagnóstico , Infarto del Miocardio/terapia , Tomografía de Coherencia Óptica , Cateterismo Cardíaco , Medios de Contraste , Angiografía Coronaria/métodos , Stents Liberadores de Fármacos , Europa (Continente) , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea , Estudios Prospectivos , Interpretación de Imagen Radiográfica Asistida por Computador , Método Simple Ciego , Trombectomía , Resultado del Tratamiento
2.
Cardiovasc Ultrasound ; 11: 25, 2013 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-23870248

RESUMEN

PURPOSE: To evaluate the atherosclerotic evolution in coronary bifurcations located proximally and distally to a bioresorbable scaffold. METHODS: Thirty bifurcations located >5 mm beyond the scaffolded segment, being investigated with serial intravascular ultrasound virtual histology (IVUS-VH) examinations, at baseline and 2-years, in patients enrolled in the ABSORB cohort B1 study were included in this analysis. In each bifurcation, the frames portraying the proximal rim, in-bifurcation, and distal rim of the ostium of the side branch were analyzed. The geometric parameters and plaque types were evaluated at baseline and 2-years follow-up. RESULTS: There were no significant differences in the geometrical parameters such as lumen, vessel and plaque areas as well as in the composition of the atheroma between baseline and 2-years follow-up.When we separately examined the bifurcations located proximally and distally to the scaffolded segment, no changes were found at the distal bifurcations, while at the proximal bifurcations there was a statistical significant decrease in the plaque burden (36.67 ± 13.33% at baseline vs. 35.06 ± 13.20% at 2 years follow-up, p = 0.04).Ten necrotic core rich plaques were found at baseline, of which 2 regressed to either fibrotic plaque or to intimal thickening at 2 years follow-up. The other 8 did not change. Disease progression was noted in 3 plaques (1 adaptive intimal thickening, 1 fibrotic and 1 fibrocalcific plaque) that evolved to necrotic rich plaques. CONCLUSIONS: Plaque regression was noted at the bifurcations located proximally to the bioresorbable scaffold but not at these located distally. Additional studies are required to confirm this finding and examine further the effect of drug elution on atherosclerotic evolution.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Stents Liberadores de Fármacos , Ecocardiografía/métodos , Sirolimus/análogos & derivados , Ultrasonografía Intervencional/métodos , Anciano , Estenosis Coronaria , Everolimus , Femenino , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Inmunosupresores/administración & dosificación , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Sirolimus/administración & dosificación , Técnica de Sustracción , Resultado del Tratamiento , Interfaz Usuario-Computador
3.
Eur Heart J ; 34(14): 1050-60, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23396493

RESUMEN

AIMS: Primary percutaneous coronary intervention (PPCI) with thrombectomy (TB) seems to reduce the thrombus burden, resulting in a larger flow area as measured with optical frequency domain imaging (OFDI). METHODS AND RESULTS: In a multi-centre study, 141 patients with ST elevation myocardial infarction <12 h from onset were randomized to either PPCI with TB using an Eliminate catheter (TB: n = 71) or without TB (non-TB: n = 70), having operators blinded for the OFDI results. The primary endpoint was minimum flow area (MinFA) post-procedure assessed by OFDI, defined as: [stent area + incomplete stent apposition (ISA) area] - (intraluminal defect + tissue prolapse area). Sample size was based on the expected difference of 0.72 mm(2) in MinFA. Baseline demographics, pre-procedural quantitative coronary angiography (QCA), and procedural characteristics were well matched between the two groups. On OFDI, the stent area (TB: 7.62 ± 2.23 mm(2), non-TB: 7.05 ± 2.12 mm(2), P = 0.14) and MinFA (TB: 7.08 ± 2.14 mm(2) vs. non-TB: 6.51 ± 1.99 mm(2), Δ0.57 mm(2), P = 0.12) were not different. In addition, the amount of protrusion, intraluminal defect, and ISA area were similar in the both groups. CONCLUSION: PPCI with TB was associated with a similar flow area as well as stent area to PPCI without TB.


Asunto(s)
Trombosis Coronaria/terapia , Infarto del Miocardio/terapia , Intervención Coronaria Percutánea/métodos , Trombectomía/métodos , Velocidad del Flujo Sanguíneo/fisiología , Técnicas de Imagen Cardíaca/métodos , Circulación Coronaria/fisiología , Trombosis Coronaria/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/fisiopatología , Estudios Prospectivos , Resultado del Tratamiento
4.
Circ J ; 76(12): 2822-31, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22971949

RESUMEN

BACKGROUND: The impact of the sampling rate (SR) of optical frequency domain imaging (OFDI) on quantitative assessment of in-stent structures (ISS) such as plaque prolapse and thrombus remains unexplored. METHODS AND RESULTS: OFDI after stenting was performed in ST-segment elevation myocardial infarction (STEMI) patients using a TERUMO OFDI system (Terumo Europe, Leuven, Belgium) with 160 frames/s and pullback speed of 20 mm/s. A total of 126 stented segments were analyzed. ISS were classified as either attached or non-attached to stent area boundaries. The volume, mean area and largest area of ISS were assessed according to 4 frequencies of SR, corresponding to distances between the analyzed frames of 0.125, 0.25, 0.50 and 1.0 mm. ISS volume was calculated by integrating cross-sectional ISS areas multiplied by each sampling distance using the disk summation method. The volume and mean area of ISS became significantly larger, while the largest area became significantly smaller as sampling distance became larger (1.11 mm(2) for 0.125 mm vs. 1.00 mm(2) for 1.0 mm, P for trend=0.036). In addition, variance of difference was positively associated with increasing width of sampling distance. CONCLUSIONS: Quantification of ISS is significantly influenced by the applied frequency of SR. This should be taken into account when designing future OFDI studies in which quantitative assessment of ISS is critical for the evaluation of STEMI patients.


Asunto(s)
Reestenosis Coronaria/diagnóstico , Trombosis Coronaria/diagnóstico , Vasos Coronarios/patología , Stents Liberadores de Fármacos , Infarto del Miocardio/terapia , Intervención Coronaria Percutánea/instrumentación , Tomografía de Coherencia Óptica , Análisis de Varianza , Reestenosis Coronaria/etiología , Reestenosis Coronaria/patología , Trombosis Coronaria/etiología , Trombosis Coronaria/patología , Europa (Continente) , Humanos , Variaciones Dependientes del Observador , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Reproducibilidad de los Resultados , Método Simple Ciego , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...