RESUMEN
OBJECTIVES: This study aimed to evaluate the marginal and internal fit of zirconia crowns were fabricated using scan data from an intraoral optical coherence tomography (OCT) scanner and an intraoral scanner (IOS) for scanning the subgingival finish line. METHODS: An extracted maxillary left central incisor was prepared for a zirconia crown. The prepared tooth was placed in artificial gingiva, created using silicone with a refractive index similar to that of the tooth, ensuring a subgingival depth of 0.50 to 0.70 mm from the labial finish line. Scanning data were obtained from four types of models as follows. (1) CAD reference model (CRM) excluding the gingiva and scanned using a laboratory scanner. (2) IOS group excluding the gingiva (IOS only, IOSO group). (3) IOS group with scanned attached artificial (IOS with gingiva, IOSG group). (4) OCT post-processed data of the subgingival finish line and IOSG data (OCT group). Zirconia crowns were fabricated based on these data, and their marginal and internal fit were evaluated using the silicone replica technique. Statistical analyses were conducted using one-way and two-way ANOVA (α = 0.05). RESULTS: The OCT group exhibited a significantly smaller marginal gap than the IOSG group (P < 0.05). The marginal fit of the OCT group did not significantly differ from that of the CRM group (P > 0.05). The IOSG group exhibited a significantly larger chamfer gap, while both the IOSG and OCT groups had significantly larger axial gaps. Furthermore, the OCT group showed a significantly larger incisal gap (P < 0.05). CONCLUSIONS: An intraoral OCT system can enhance the fabrication accuracy of zirconia crowns by achieving superior marginal fit for crowns with subgingival finish lines. CLINICAL SIGNIFICANCE: The use of an IOS for subgingival finish lines without gingival displacement cords may result in a suboptimal marginal fit. However, integrating OCT technology can effectively address this issue, leading to improved clinical outcomes.
RESUMEN
BACKGROUND: Minimizing muscle strain and reducing the risk of musculoskeletal disorders associated with intraoral scanner (IOS) usage require ergonomic awareness, device selection, and workplace adjustments in dental practice. This preliminary clinical study aimed to simulate intraoral scanning tasks using wired and wireless IOSs and assess muscle activation and fatigue for both types. MATERIALS AND METHODS: Fourteen participants performed intraoral scanning tasks using wired and wireless IOSs (i700; MEDIT), with weights of 280 g and 328 g, respectively. The same computer system and software conditions were maintained for both groups (N = 14 per IOS group). Electrodes were placed on arm, neck, and shoulder muscles, and maximal voluntary contraction (MVC) was measured. Surface electromyography (EMG) was performed during the simulation, and EMG values were normalized using MVC. The root mean square EMG (%MVC) and muscle fatigue (%) values were calculated. Statistical comparisons were performed using the Mann-Whitney U and Friedman tests, with the Bonferroni adjustment for multiple comparisons (α = 0.05). RESULTS: Arm (flexor digitorum superficialis) and neck muscles (left sternocleidomastoid and left splenius capitis) showed significantly higher EMG values with wireless IOS (P < 0.05). The neck (left sternocleidomastoid and right levator scapulae) and shoulder muscles (right trapezius descendens) demonstrated significantly higher muscle fatigue with wireless IOS (P < 0.05). CONCLUSIONS: The consecutive use of heavier wireless IOS may increase the risk of muscle activation and fatigue in certain muscles, which may have clinical implications for dentists in terms of ergonomics and musculoskeletal health.
Asunto(s)
Electromiografía , Humanos , Masculino , Adulto , Electromiografía/métodos , Femenino , Enfermedades Musculoesqueléticas/etiología , Enfermedades Musculoesqueléticas/prevención & control , Fatiga Muscular/fisiología , Músculo Esquelético/fisiología , Músculo Esquelético/fisiopatología , Ergonomía/métodos , Adulto Joven , Contracción Muscular/fisiologíaRESUMEN
This study aimed to analyze the effect of the height of the proximal axial wall of the prepared tooth and the distance between the adjacent tooth and the prepared tooth on the scan accuracy of intraoral scanners. Ten working casts with maxillary first molars prepared to receive zirconia crowns were randomly obtained from a dental clinic. Each of the 10 casts was scanned using two intraoral scanners (i700; MEDIT and CS3600; Carestream; computer-aided design [CAD] test model, CTM; N = 15 per working cast) 15 times per scanner. Individual dies of the prepared teeth were fabricated, and high-precision scan data were acquired using a laboratory scanner (CAD reference model, CRM; N = 1). CTMs were aligned relative to the prepared tooth of CRMs by using three-dimensional inspection software (Ver 2018.1.0; Control X; 3D Systems). Data were statistically analyzed using an independent t-test and one-way analysis of variance for between-group comparisons (α = 0.05). The inaccuracy in the proximal regions (mesial or distal) of the prepared tooth was higher than that in the buccal and lingual regions (p < 0.05). The scan accuracy was not correlated with the variables when the distance between the adjacent tooth and the prepared tooth was ≥2.0 mm and the height of the proximal axial wall of the prepared tooth was <3.0 mm (p > 0.05). Therefore, an excellent scan accuracy can be obtained using an intraoral scanner when the distance between the adjacent tooth and the prepared tooth is ≥2.0 mm and the proximal axial wall height of the prepared tooth is <3.0 mm.
RESUMEN
OBJECTIVES: The aim of this study is prognostic assessment of surface smoothness and the presence of internal bubbles after treatment of non-cancerous cervical lesions (NCCLs) using optical coherence tomography (OCT). METHODS: After treatment with NCCLs, cross-sectional images of the lesion parts of the sample were non-invasively acquired and analyzed. The surface smoothness between tooth and resin, resin and cemento-enamel junction, and the presence bubble inside resin was confirmed. In addition, using an algorithm that distinguishes between resin and dental structure based on OCT cross-sectional images, we quantitatively analyzed the amount of resin used in treating NCCLs and acquired 3D images. RESULTS: The inner structure of the resin in each sample was checked, and the presence of bubbles was confirmed. In addition, the resin sections were separated from the tomographic images acquired by OCT to visualize 3D images. The volume of resin used in the treatment part of each NCCLs samples was quantitatively analyzed as 3.7216 â¼ 14.889 mm3. CONCLUSIONS: OCT is able to measure not only the surface abrasion provided by existing intraoral scanner, but also the size and depth location of interal bubbles, which is distinctive advantage of our method. Based on our results, OCT is a significant tool for qualitative and quantitative analysis of dental NCCLs treatment before and after treatment. CLINICAL SIGNIFICANCE: The study used OCT, a non-destructive diagnostic, to reveal the structure of the resin and the location and size of bubbles after NCCLs treatment. These findings could be golden standard in determining the prognosis of NCCLs treatment.
Asunto(s)
Imagenología Tridimensional , Tomografía de Coherencia Óptica , Cuello del Diente , Tomografía de Coherencia Óptica/métodos , Humanos , Cuello del Diente/diagnóstico por imagen , Cuello del Diente/patología , Imagenología Tridimensional/métodos , Algoritmos , Propiedades de Superficie , Resinas Compuestas/química , Resinas Compuestas/uso terapéutico , Restauración Dental Permanente/métodosRESUMEN
This study aimed to measure marginal and internal fit using images captured with both an optical microscope and a smartphone camera, comparing the fit measurement performance of these devices and analyzing their correlation. Working casts (with 10 posterior and 10 anterior teeth) created to fabricate fixed dental prostheses were used. These working casts were scanned using a desktop scanner (E1) to design an interim crown, and the designed interim crown was fabricated using a three-dimensional (3D) printer. Utilizing the silicone replica technique, the fabricated interim crown replicated the fit, which was then captured using both an optical microscope and a smartphone camera. The captured images were used to measure the marginal and internal fit according to the imaging device. Intraclass correlation coefficients (ICC) were used for reliability analysis according to the imaging device. Furthermore, the Wilcoxon signed-rank test was adopted for the comparative evaluation of the marginal and internal fit between the imaging devices (α = 0.05). The measurement results of the marginal and internal fit according to the optical microscope and smartphone camera did exhibit a significant difference (P < 0.05). The ICC between the two devices showed an "excellent" agreement of over 0.9 at all measurement points (P < 0.001). A smartphone camera could be used to obtain images for evaluating the marginal and internal fit.
Asunto(s)
Prótesis Dental , Teléfono Inteligente , Correlación de Datos , Estudios de Factibilidad , Reproducibilidad de los ResultadosRESUMEN
STATEMENT OF PROBLEM: Improvement in the mechanical properties of 3-dimensional (3D) printed dental prostheses is necessary to prevent wear caused by an antagonist or fracture. However, how different printing temperatures affect their mechanical properties is unclear. PURPOSE: The purpose of this in vitro study was to evaluate the mechanical properties of 3D printed parts fabricated at different printing temperatures. MATERIAL AND METHODS: Photopolymer specimens were fabricated at 3 different temperatures (room temperature, 50 °C, and 70 °C) using a stereolithography 3D printer. After rinsing to remove the residual monomer, the specimens were divided into 2 groups: with or without postprocessing. The viscosity of the photopolymerization resin was measured while the temperature was increased. Furthermore, the double-bond conversion (DBC) of the printed part was evaluated (n=3). Mechanical properties were investigated via dynamic mechanical analysis (n=1) and tensile testing (n=5). Statistical comparisons were performed via 1-way analysis of variance, followed by the Tukey honestly significant difference test (α=.05). RESULTS: The DBC rates of the green condition group increased from 66.67% to 86.33% with increasing temperature. In addition, these specimens exhibited improved mechanical properties and reduced residual monomer levels. CONCLUSIONS: Specimens fabricated at a temperature of 70 °C exhibited mechanical properties suitable for clinical application.
Asunto(s)
Impresión Tridimensional , Estereolitografía , Temperatura , Polimerizacion , Ensayo de Materiales , Propiedades de SuperficieRESUMEN
STATEMENT OF PROBLEM: Prostheses printed on a 3-dimensional (3D) printer need to undergo the postpolymerization process, which can increase the working time. However, it has been not suggested for reducing workload and improving the properties of prostheses in dental clinical practice. PURPOSE: The purpose of this in vitro study was to evaluate how the printing temperature impacts the dimensional accuracy and fracture load of 3D printed fixed dental prostheses (FDPs). MATERIAL AND METHODS: Dental prostheses were printed at room temperature (RT), 50°C, and 70°C using a stereolithography 3D printer. Subsequently, after rinsing away residual monomer, the printed parts underwent the green condition (it was not subjected to any postprocessing) and postpolymerization. The mechanical properties of the printed FDPs were determined by loading to fracture (n=6). To evaluate their clinical applicability, the dimensional accuracy and fit of FDPs fabricated at various resin polymerization temperatures were measured (n=6). The 1-way analysis of variance was used to perform statistical comparisons, followed by the Tukey honestly significant difference test (α=.05). RESULTS: The specimens printed at RT and 50°C were better than those printed at 70°C in terms of dimensional accuracy and fit (P<.05). Nonetheless, the dimensional accuracy and fit of the specimens printed at 70°C were clinically acceptable. The fracture load of the 3-unit FDPs depended significantly on the printing temperature. CONCLUSIONS: The dimensional accuracy and fracture load of the 70°C group were acceptable for FDP fabrication. Thus, the temperature of 70°C without postprocessing may help make the procedure more efficient.
Asunto(s)
Prótesis Dental , Estereolitografía , Temperatura , Diseño Asistido por Computadora , Polimerizacion , Ensayo de Materiales , Impresión TridimensionalRESUMEN
This clinical study aimed to predict the learning curve of wireless and wired intraoral scanners (IOSs) and to compare the reduction patterns of working time. Overall, 14 participants were enrolled in the study. The intraoral scanning procedure was repeated four times, each using wireless and wired IOSs (i700; MEDIT). The work time from the first to the 600th iterations was predicted using the Wright model. Regarding statistical analysis, the Mann-Whitney U-test was performed for comparison between wireless and wired IOSs and between groups with and without an IOS usage experience, and the Friedman test was performed to evaluate the time reduction (α = 0.05). There was a significant difference between wireless and wired IOSs in the first (P = 0.008) and the third (P = 0.035) iterations. Moreover, the time for 600 iterations was statistically significantly different between wireless and wired IOSs (P < 0.05); however, there was no significant difference after the sixth iteration (e.g., seventh iteration: P = 0.062). In wireless IOS, no significant difference was found between participants with and without an IOS usage experience after the 34th iteration (P = 0.053). The difference in the learning effect between wireless and wired IOSs can be overcome by initial learning; however, an IOS usage experience can affect the learning time of wireless IOSs.
Asunto(s)
Imagenología Tridimensional , Curva de Aprendizaje , Humanos , Diseño Asistido por Computadora , Modelos Dentales , Estadísticas no ParamétricasRESUMEN
This clinical report introduces an approach for detecting the supragingival finish line by penetrating the teeth and gingival tissue using optical coherence tomography (OCT) technology. This approach was used in 3 patients who underwent tooth preparation with a subgingival finish line. Consequently, the subgingival finish line, typically challenging to discern clearly in intraoral scans, was identifiable in the OCT image.
RESUMEN
The purpose of this study was to investigate the effects of different peri-implantitis treatment methods (Er,Cr:YSGG laser, diode laser, and electrocautery) on various titanium implant surfaces: machined; sandblasted, large-grit, and acid-etched; and femtosecond laser-treated surfaces. Grade 4 titanium (Ti) disks, with a diameter of 10 mm and a thickness of 1 mm, were fabricated and treated using the aforementioned techniques. Subsequently, each treated group of disks underwent different peri-implantitis treatment methods: Er,Cr:YSGG laser (Biolase, Inc., Foothill Ranch, CA, USA), diode laser (Biolase, Inc., Foothill Ranch, CA, USA), and electrocautery (Ellman, Hicksville, NY, USA). Scanning electron microscopy, energy-dispersive X-ray spectroscopy, and wettability were used to characterize the chemical compositions and surfaces of the treated titanium surfaces. Significant changes in surface roughness were observed in both the electrocautery (Sa value of machined surface = 0.469, SLA surface = 1.569, femtosecond laser surface = 1.741, and p = 0.025) and Er,Cr:YSGG laser (Ra value of machined surface = 1.034, SLA surface = 1.380, femtosecond laser surface = 1.437, and p = 0.025) groups. On femtosecond laser-treated titanium implant surfaces, all three treatment methods significantly reduced the surface contact angle (control = 82.2°, diode laser = 74.3°, Er,Cr:YSGG laser = 73.8°, electrocautery = 76.2°, and p = 0.039). Overall, Er,Cr:YSGG laser and electrocautery treatments significantly altered the surface roughness of titanium implant surfaces. As a result of surface composition after different peri-implantitis treatment methods, relative to the diode laser and electrocautery, the Er,Cr:YSGG laser increased oxygen concentration. The most dramatic change was observed after Er:Cr;YSGG laser treatment, urging caution for clinical applications. Changes in surface composition and wettability were observed but were not statistically significant. Further research is needed to understand the biological implications of these peri-implantitis treatment methods.
RESUMEN
PURPOSE: This study aimed to evaluate the effects of an ergonomic dentist stool design on muscle activity and fatigue in dentists. MATERIALS AND METHODS: Fourteen dentists were recruited, and electrodes were attached to the arm, neck, and shoulder muscles of these dentists according to the Surface ElectroMyoGraphy for the Non-Invasive Assessment of Muscles protocol. After measuring the maximal voluntary contraction, eight-channel surface electromyography was performed during simulations of two dental procedures (intraoral scanning and tooth preparation) while the dentists were using two types of dentist stools. Furthermore, muscle activity and fatigue were determined based on the eight-channel surface electromyography data, and ergonomic risk levels were evaluated according to the muscle activity. The Shapiro-Wilk test was used to confirm that all data were normally distributed, and the Mann-Whitney U test was used to compare the two types of dentist stools (α = 0.05). RESULTS: There was a significant difference between the conventional and ergonomically designed dentist stools in terms of the activity of trapezius descendens muscle (p < 0.05). Notably, the activity of the trapezius descendens muscle was lesser when the dentists used ergonomically designed dentist stools than when they used a conventional dentist stool. The activity of all muscles, except for the sternocleidomastoid, indicated moderate ergonomic risk. CONCLUSION: A dentist stool that enables dentists to maintain ergonomic posture should be used to prevent musculoskeletal disorders.
RESUMEN
(1) Background: The purpose of this study was to evaluate how a zirconia implant surface treated with laser technology affects the degree of biofilm formation. (2) Methods: Experimental titanium (Ti) disks were produced that were sandblasted with large grit and acid-etched (T), and they were compared with zirconia (ZrO2) discs with a machined (M) surface topography; a hydrophilic surface topography with a femtosecond laser (HF); and a hydrophobic surface topography with a nanosecond laser (HN) (N = 12 per surface group). An in vitro three-species biofilm sample (Aggregatibacter actinomycetemcomitans (Aa), Porphyromonas gingivalis (Pg), Prevotella intermedia (Pi)) was applied to each disc type, and bacterial adhesion was assessed after 48 and 72 h of incubation using an anaerobic flow chamber model. Statistical significance was determined using the Kruskal-Wallis H test, with Bonferroni correction used for the post-hoc test (α = 0.05). (3) Results: Compared to the T group, the M group exhibited more than twice as many viable bacterial counts in the three-species biofilm samples (p < 0.05). In comparison to the T group, the HF group had significantly higher viable bacterial counts in certain biofilm samples at 48 h (Aa and Pi) and 72 h (Pi) (p < 0.05). The HN group had higher viable bacterial counts in Pi at 48 h (5400 CFU/mL, p < 0.05) than the T group (4500 CFU/mL), while showing significantly lower viable bacterial counts in Pg at both 48 (3010 CFU/mL) and 72 h (3190 CFU/mL) (p < 0.05). (4) Conclusions: The surface treatment method for zirconia discs greatly influences biofilm formation. Notably, hydrophobic surface treatment using a nanosecond laser was particularly effective at inhibiting Pg growth.
RESUMEN
This study evaluated the effects of various mechanical debridement methods on the surface roughness (Ra) of dental implants, comparing femtosecond laser-treated surfaces with conventionally machined and sandblasted with large-grit sand and acid-etched (SLA) implant surfaces. The fabrication of grade 4 titanium (Ti) disks (10 mm in diameter and 1 mm thick) and the SLA process were carried out by a dental implant manufacturer (DENTIS; Daegu, Republic of Korea). Subsequently, disk surfaces were treated with various methods: machined, SLA, and femtosecond laser. Disks of each surface-treated group were post-treated with mechanical debridement methods: Ti curettes, ultrasonic scaler, and Ti brushes. Scanning electron microscopy, Ra, and wettability were evaluated. Statistical analysis was performed using the Kruskal-Wallis H test, with post-hoc analyses conducted using the Bonferroni correction (α = 0.05). In the control group, no significant difference in Ra was observed between the machined and SLA groups. However, femtosecond laser-treated surfaces exhibited higher Ra than SLA surfaces (p < 0.05). The application of Ti curette or brushing further accentuated the roughness of the femtosecond laser-treated surfaces, whereas scaling reduced the Ra in SLA surfaces. Femtosecond laser-treated implant surfaces, with their unique roughness and compositional attributes, are promising alternatives in dental implant surface treatments.
RESUMEN
This study aimed to evaluate the impact of different surface treatments (machined; sandblasted, large grit, and acid-etched (SLA); hydrophilic; and hydrophobic) on dental titanium (Ti) implant surface morphology, roughness, and biofilm formation. Four groups of Ti disks were prepared using distinct surface treatments, including femtosecond and nanosecond lasers for hydrophilic and hydrophobic treatments. Surface morphology, wettability, and roughness were assessed. Biofilm formation was evaluated by counting the colonies of Aggregatibacter actinomycetemcomitans (Aa), Porphyromonas gingivalis (Pg), and Prevotella intermedia (Pi) at 48 and 72 h. Statistical analysis was conducted to compare the groups using the Kruskal-Wallis H test and the Wilcoxon signed-rank test (α = 0.05). The analysis revealed that the hydrophobic group had the highest surface contact angle and roughness (p < 0.05), whereas the machined group had significantly higher bacterial counts across all biofilms (p < 0.05). At 48 h, the lowest bacterial counts were observed in the SLA group for Aa and the SLA and hydrophobic groups for Pg and Pi. At 72 h, low bacterial counts were observed in the SLA, hydrophilic, and hydrophobic groups. The results indicate that various surface treatments affect implant surface properties, with the hydrophobic surface using femtosecond laser treatment exerting a particularly inhibitory effect on initial biofilm growth (Pg and Pi).
RESUMEN
PURPOSE: Accuracy of image matching between resting and smiling facial models is affected by the stability of the reference surfaces. This study aimed to investigate the morphometric variations in subdivided facial units during resting, posed and spontaneous smiling. MATERIALS AND METHODS: The posed and spontaneous smiling faces of 33 adults were digitized and registered to the resting faces. The morphological changes of subdivided facial units at the forehead (upper and lower central, upper and lower lateral, and temple), nasal (dorsum, tip, lateral wall, and alar lobules), and chin (central and lateral) regions were assessed by measuring the 3D mesh deviations between the smiling and resting facial models. The one-way analysis of variance, Duncan post hoc tests, and Student's t-test were used to determine the differences among the groups (α = .05). RESULTS: The smallest morphometric changes were observed at the upper and central forehead and nasal dorsum; meanwhile, the largest deviation was found at the nasal alar lobules in both the posed and spontaneous smiles (P < .001). The spontaneous smile generally resulted in larger facial unit changes than the posed smile, and significant difference was observed at the alar lobules, central chin, and lateral chin units (P < .001). CONCLUSION: The upper and central forehead and nasal dorsum are reliable areas for image matching between resting and smiling 3D facial images. The central chin area can be considered an additional reference area for posed smiles; however, special cautions should be taken when selecting this area as references for spontaneous smiles.
RESUMEN
STATEMENT OF PROBLEM: Various strategies for intraoral scanners (IOSs) can be used to scan the oral cavity. However, research on the scan range that can be clinically is lacking. PURPOSE: The purpose of this in vitro study was to compare the 3-dimensional (3D) distortion of complete arch scans as part of the scan strategy and analyze the clinically recommended scan range. MATERIAL AND METHODS: A computer-aided design (CAD) reference model was obtained with an industrial scanner. A CAD test model was obtained by using 6 IOSs (TRIOS2, TRIOS3, CS3500, CS3600, i500, and Primescan) to apply 2 scan strategies and 2 dental laboratory scanners (DOF and E1) (N=15). All the teeth were segmented in the reference model by using 3D inspection software (Geomagic control X). The 3D analysis was performed by aligning the test model to the reference model and evaluating the root mean square values of all segmented teeth. The Mann-Whitney U-test was performed for a statistical comparison of the 2 scan strategies (α=.05), the Kruskal-Wallis test (α=.05) was used to compare the scanners, and the Mann-Whitney U-test and Bonferroni correction method were used as post hoc tests (α=.0017). RESULTS: The 8 scanners obtained significant differences in the root mean square values of all teeth (P<.001). The root mean square value of IOSs increased from the left maxillary second molar to the right maxillary second molar. The difference in the 2 scan strategies showed different patterns depending on the IOS. CONCLUSIONS: Scan strategy 2 improved the accuracy of the IOSs. TRIOS2 and CS3500 are for single crowns; TRIOS3, CS3600, and i500 are for short-span prostheses; and Primescan is for long-span prostheses.
Asunto(s)
Técnica de Impresión Dental , Imagenología Tridimensional , Estudios de Factibilidad , Modelos Dentales , Diente Molar , Diseño Asistido por Computadora , Arco Dental/diagnóstico por imagenRESUMEN
PATIENTS: The patient was a 32-year-old man who underwent amalgam restoration of the mandibular right second molar. An amalgam restoration fracture was diagnosed by intraoral optical coherence tomography (OCT), and pulp exposure was examined during cavity preparation. Subsequently, a definitive ceramic restoration was fabricated, and the marginal fit in the oral cavity was evaluated using the OCT system. DISCUSSION: The existing OCT system cannot acquire images inside the oral cavity because of the large probe size. However, the proposed intraoral OCT system can access the prostheses in the mandibular right second molar. Therefore, dental diagnosis for restoration treatment with dental prosthesis fracture, marginal gap, and pulp exposure after tooth preparation is possible using the proposed intraoral OCT system. CONCLUSIONS: The use of the intraoral OCT system improved dental diagnosis by allowing the dentist to confirm quantitative values through cross-sectional images, rather than that by determining a treatment plan after visual dental diagnosis.
Asunto(s)
Incrustaciones , Tomografía de Coherencia Óptica , Humanos , Adulto , Tomografía de Coherencia Óptica/métodos , Diente Molar , Preparación de la Cavidad Dental , BocaRESUMEN
PURPOSE: To evaluate the fit and trueness of temporary crowns fabricated with 3D printing vs milling technologies and to analyze any existing correlations between fit and trueness. MATERIALS AND METHODS: Marginal and internal fit and trueness were evaluated. Groups were compared using Kruskal-Wallis H test (α = .05), and correlations were analyzed using Spearman rank correlation analysis (α = .0016). RESULTS: Intaglio surface trueness was partially correlated with the marginal and internal fit (P < .0016). CONCLUSION: High intaglio surface trueness in the axial and occlusal regions may result in poor marginal fit. In the axial region, high intaglio surface trueness may adversely affect both the marginal and internal fit.
Asunto(s)
Coronas , Adaptación Marginal Dental , Estereolitografía , Diseño Asistido por Computadora , Diseño de Prótesis Dental , Impresión TridimensionalRESUMEN
This study aimed to compare the trueness of intraoral scanners (IOSs) according to the subgingival finish line depth of tooth preparation for fixed prostheses. The prepared maxillary right first molar was fabricated by using ceramic material. A computer-aided design (CAD) reference model (CRM) of the abutment was obtained by using a contact scanner. The subgingival finish line was located according to the depth at 0-mm, 0.25-mm, 0.5-mm, 0.75-mm, and 1-mm. CAD test models (CTMs) were obtained by using 2 IOSs (i500 and CS3600). CRM and CTM were superimposed and analyzed (Geomagic control X). The one-way analysis of variance (ANOVA) was used to compare the trueness according to the subgingival finish line depth. The paired t test was used to compare the trueness of IOSs with and without gingival retraction (α = .05). When the gingival displacement code was not used, it was observed that the trueness of both IOSs decreased significantly as the depth of the subgingival finish line increased (P < 0.001). When the subgingival finish line was positioned deeper than 0.5-mm, the trueness of both IOSs exceeded 100 µm in the marginal region. When the gingival displacement cord was used, the trueness of both IOSs did not exceed 100 µm regardless of the subgingival finish line depth. When gingival cord was used, it showed significantly higher trueness than when not used (P < 0.001). When the gingival displacement cord was not used, the trueness of IOSs decreased as the subgingival finish line depth increased. But the use of the gingival displacement cord improved the scanning trueness by 90%. Thus, it is necessary to use the gingival displacement cord according to the clinical situation to improve scan trueness at the subgingival finish line.
Asunto(s)
Miembros Artificiales , Distrofias de Conos y Bastones , Humanos , Implantación de Prótesis , Encía , Diseño Asistido por Computadora , Análisis de VarianzaRESUMEN
The present study aimed to confirm the usefulness of a multi-laser handpiece system currently under development. Implants were placed in the tibia of rabbits using a conventional separate laser-implant handpiece system (control group; SurgicPro+; NSK, Kanuma, Japan and Epic 10; Biolase, Irvine, CA, USA) and a multi-laser handpiece system (experimental group; BLP 10; Saeshin, Daegu, Korea). Implants were placed in left and right tibias of five rabbits using a conventional laser-implant handpiece system and a multi-laser handpiece system (N = 5 per group). Subsequently, micro-computed tomography (micro-CT; bone-to-implant contact evaluation), implant stability quotient (ISQ) measurement, and histological evaluations were performed to confirm the implant placement results. The independent t-test and the paired t-test were used to compare the ISQ values and the results of the two implant-laser handpiece groups (α = 0.05), respectively. No statistically significant difference in micro-CT, ISQ, and histological evaluations was observed between implant placement by the two systems (p > 0.05) except implant initial stability. The use of the multi-laser handpiece system is expected to produce the same results as a conventional separate laser-implant handpiece system with the higher implant initial stability. Additionally, it will potentially make the clinical environment more pleasant and will provide convenience for the clinicians.